| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC MATTILIPARAMBIL HOUSE SAHODHARAN AYYAPPAN ROAD EROOR WEST PO THIRUPUNITHURA 682306 | THIRUPUNITHURA | ERNAKULAM | KERALA | 682306 | L1 | Accepted-AOC BEING LOWEST TENDERER | |
| 2 | L2₹39.0 L+₹2.2 L (6.05%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹40.0 L+₹3.2 L (8.83%)Rejected-Finance 17 1305 ARIAKATTU PALLURUTHY KOCHI 682 006 | KOCHI | ERNAKULAM | KERALA | 682006 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹45.8 L+₹9.1 L (24.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹46.7 L+₹9.9 L (27.0%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
24 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(NW)KOCHI
GARRISON ENGINEER (NW) MILITARY ENGINEER SERVICES NAVAL BASE POST -682 004
AS PER BOQ AND TENDER DOCUMENT
2023_MES_599373_1
8247_GE_NW
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
KOCHI
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE(NW)KOCHI
₹99,800
Yes
3 Aug 2023
29 May 2023
26 Jun 2023
29 May 2023
24 Jun 2023
11 Jun 2023
29 May 2023 - 17 Jun 2023
Amount
Taking down Copper/ aluminium point wiring (light, fan, socket, bell, power point) complete fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting any type, building security light removing materials to store for keeping in safe custdoy for taking credit to match with existing suface complete all as specified and directed.
M&L Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLSH cable 1100 Volts grade including PVC casing and caping and connected accessories ISI marked with concealed sunken boxes with modular cover plate, PVC boxes, hylem sheet, including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLSH cable single core multistranded cable as earth continuity wire for one light controlled by one switch complete all as specified and directed.
All as per item No. 2 here-in-before but for one fan point controlled by one push button on independent board complete all as specified and directed.
All as per item No. 2 here-in-before but for one bell point controlled by one push button on independent board complete all as specified and directed.
All as per item No. 2 here-in-before but for 5 pin 5 Amps socket outlet point on independent board complete all as specified and directed.
All as per item No. 2 here-in-before but for 5 pin 5 Amps socket outlet point on same board complete all as specified and directed. .
All as per item No 2 here-in-before but using 2.5 sqmm copper conductor cable (multistranded) PVC insulated FRLSH and unsheathed cable and 2.5 sqmm copper conductor cable (multistranded) PVC insulated FRLSH and unsheathed cable earthwire with terminal box of suitable size of modular switch & socket for one 6 pin 15 Amp socket outlet point on independent board complete all as specified and directed.
M&L for point wiring for one light with 1.5 sqmm PVC insulated (FRLSH) unsheathed copper conductor multistranded 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FRLSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity conductor including connected to common earth dolly drawn through and including rigid PVC Conduit medium grade ISI marked Concealed of suitable size with all accessories and sunken box of 1.6 mm thick and 60 mm Depth pressed steel box factory made for mounting of switch, socket and fan regulator with modular frames covers including chase cutting and making good to the disturbed surface and matching to the existing finishes specifications complete all as specified and directed.
All as per item No. 8 here-in-before but for one fan point controlled by one push button on independent board
All as per item No. 8 here in before but for one bell point controlled by one 5 Amp bell push on independent board complete all as specified and directed.
All as per item No. 8 here in before but for one 5 pin 5 Amp socket outlet point on independent board complete all as specified and directed.
All as per item No. 8 here in before but for one 5 pin 5 Amp socket outlet point on the same board complete all as specified and directed.
All as per item No. 8 here in before but using with 2.5 Sqmm copper conductor cables multistranded (FRLSH) PVC insulated, unsheated cable and including 2.5 Sqmm copper conductor cable multistranded (FRLSH) PVC insulated and unsheated cable as earth continity wire and connecting to common earth dolly for one 6 pin 15 Amp socket outlet point on independent board complete all as specified and directed.
S&F Modular Bell Push 6A, 1 module , complete all as specified and as directed.
S&F electric bell, AC 230 Volt single pole complete all as specified and as directed.
S&F switch piano flush type single pole one way 5 Amp one way complete all as specified and as directed.
S&F switch piano flush type single pole one way 15 Amp complete all as specified and as directed.
S&F switch socket combination 5 Amps, 5 pin 2 in 1 , complete all as specified and as directed.
S&F in socket outlet multipurpose 5 and 15 Amps, 5 pin, 2 in 1 complete all as specified and directed.
S&F fan regulator electronic step type 100 W, 250 Volts complete all as specified and as directed.
S&F ceiling rose surface bakelite 65 x 50 mm, 3 terminals complete all as specified and as directed.
S&F in repair, bell push flush type 5 Amps single pole complete all as specified and as directed.
S&F in repair, electric bell, AC 230 Volt single pole complete all as specified and as directed.
S&F in repair, switch piano flush type single pole one way 5 Amp one way complete all as specified and as directed.
S&F in repair, switch piano flush type single pole one way 15 Amp complete all as specified and as directed.
S&Fin repair, socket outlet 5 Amps, 5 pin, 2 in 1 complete all as specified and directed.
S&F in repair, socket outlet multipurpose 5 and 15 Amps, 5 pin, 2 in 1 complete all as specified and directed.
S&F in repair, switch socket combination 5 Amps, 5 pin 2 in 1, complete all as specified and as directed.
S&F in repair, switch socket combination multipurpose 5 & 15 Amps, 5 pin, 2 in 1 complete all as specified and directed.
S&F in repair, fan regulator electronic step type 100 W, 250 Volts complete all as specified and as directed.
S&F in repair, capacitor for ceiling fans,230 volts, 2.5 MFD including necessary soldering complete all as specified and as directed. Make HavellsCat Part No. QHPCWC5002X5 or equivalent manufacturers mentioned in list of manufacturers
S&F in repair, capacitor for any type of exhaust fan/ pedestial fan/ air circulator fan 230 volts AC including necessary soldering of capacity 4 MFD complete all as specified and directed. Make HavellsCat Part No. QHPCWC5004X0 or equivalent manufacturers mentioned in list of manufacturers
S&F in repair, lamp holder, PVC/ poly carbonate type with back plate suitable for batten fittings, all as specified and directed.
S&F in repair, Ceiling rose surface bakelite 65 x 50 mm, 3 terminals complete all as specified and as directed.
M&L in repair sub main wiring with 4 runs of 10 Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLSH, ISI marked cable drawn through ISI Marked, medium grade, non metallic, PVC Casing & Capping and all accessories, with 1 run of 10 Sq mm PVC insulated unsheathed multistranded single core copper conductor FRLSH, and making good disturbed surfaces, applying distemper/ Emulsions matching to the existing colour / quality of walls/floors/ceiling etccomplete all as specified and as directed. Note:- Five run of cable and one run of PVC casing and caping shall be measured as one unit.
All as per item No 35 here-in-before but 2 runs of 4 sq mm single core FRLSH copper conductor and 1 run of 6 sqmm conductor for earthing complete all as specified and as directed. Note:- Three run of cable and one run of PVC casing and caping shall be measured as one unit.
All as per item No 35 here-in-before but 2 runs of 6 sq mm single core FRLSH copper conductor and 1 run of 4 sqmm conductor for earthing complete all as specified and as directed.. Note:- Three run of cable and one run of PVC casing and caping shall be measured as one unit.
M&L in repair sub main wiring with 4 runs of 10 Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLSH, ISI marked cable drawn through ISI Marked, medium grade, non metallic, PVC conduits and all accessories, with 1 run of 10 Sq mm PVC insulated unsheathed multistranded single core copper conductor FRLSH, and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls/floors/ceiling etc complete all as specified and as directed. Note:- Five run of cable and one run of PVC conduits shall be measured as one unit.
All as per item No. 38 here-in-before but 4 runs of 16 sq mm single core FRLSH copper conductor and 1 run of 16 sqmm conductor for earthing complete all as specified and as directed.. Note:- Five run of cable and one run of PVC conduits shall be measured as one unit.
All as per item No. 38 here-in-before but 2 runs of 4 sq mm single core FRLSH copper conductor and 1 run of 4 sqmm conductor for earthing complete all as specified and as directed. . Note:- Three run of cable and one run of PVC conduits shall be measured as one unit.
All as per item No. 38 here-in-before but 2 runs of 6 sq mm single core FRLSH copper conductor and 1 run of 6 sqmm conductor for earthing complete all as specified and as directed. . Note:- Three run of cable and one run of PVC conduits shall be measured as one unit.
S&F in repair, Sheet Metal Enclosure for MCB DB, TPN, 4 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and as directed.
S&F in repair, Sheet Metal Enclosure for MCB DB, TPN, 8 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and as directed.
S&F in repair, Sheet Metal Enclosure for MCB DB, TPN, 12 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified.
S&F in repair, Sheet Metal Enclosure for MCB DB, SPN, 8 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and as directed.
S&F in repair, Sheet Metal Enclosure for MCB DB, SPN, 12 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and as directed.
S&F in repair, Sheet Metal Enclosure for MCB DB, SPN, 4 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and as directed.
S&F in repair, MCB TPN 63 Amps, 415 Volt, complete all as specified and directed. Make L&T Cat Part No. BB40630B or equivalent manufacturers mentioned in list of manufacturers
S&F in repair, MCB TPN 32 Amps, 415 Volt, complete all as specified and directed. Make L&T Cat Part No. BB40320B or equivalent manufacturers mentioned in list of manufacturers
S&F in repair, MCB SPN 63 Amps, 415 Volt, complete all as specified and directed. Make L&T Cat Part No. BB20630B or equivalent manufacturers mentioned in list of manufacturers
S&F in repair , MCB SP 6 to 32 Amps,415 Volt, complete all as specified and directed. Make L&T Cat Part No. BB10060B to BB10320B or equivalent manufacturers mentioned in list of manufacturers
S&F in repair , MCB SPN 6 to 32 Amps,415 Volt, complete all as specified and directed. Make L&T Cat Part No. BB20060B to BB20320B or equivalent manufacturers mentioned in list of manufacturers
S&F LED Tubelight fitting 20 Watts DAWN PLUS, smart Extruded Aluminium LED Batten (4 ft) with higher efficiency, Microwave sensor to save more energy reduces the light by 70% during non-occupancy or equivalent manufacturers mentioned in list of manufacturers .Cat Part No. BCLAB 20W LED or equivalent manufacturers mentioned in list of manufacturers
S&F in repair LED glass T8 tube 20 watt, 220 volt ,50 Hz, LED tube rod, double side connection,inbuilt driver , complete all as specified and directed Cat Part No -CRYSTAL1 213 T8D STL 20W LED865S GLASS or equivalent manufacturers mentioned in list of manufacturers
S&F in repair LED light fitting 20 W, high performance batten , 220 volt ,50 Hz,6000 k surface mounted high quality extruded polycarbonate ,enviromental friendly ,energy efficient , with all connecting accessories ,with suitable connection complete all as specified and directed Cat Part No -CCS-100-20-65-HL2-DP-NWH or equivalent manufacturers mentioned in list of manufacturers
S&F in repair LED light fitting 10 W, high performance batten , 220 volt ,50 Hz, surface mounted high quality aluminium extruded with all connecting accessories ,with suitable connection complete all as specified and directed Cat Part No-LDL-10-CDL or equivalent manufacturers mentioned in list of manufacturers
S&F in repair ceiling light driver up to 5 Watt with all accessories and connection to the electric circuit complete all as specified and directed Make Crompton Cat Part No. SRPS-5K-440.
S&F in repair ceiling light driver 10 Watt with all accessories and connection to the electric circuit complete all as specified and directed.Cat Part No - SRPSQ-10KV/5KA-440 of crompton or Surya / Havells.
S&F in repair ceiling light driver 20 Watt with all accessories and connection to the electric circuit. complete all as specified .Cat Part No - S0DVES-24-700-20W of crompton or Surya / Havells
S&F in repair 15 Watt Square recessed mounted down lighter with high luminous LED for indoor application,230 volts ,50 Hzs ,min 100 lm /watt with all accessories and connection to the electric circuit. complete all as specified and directed Cat Part No- LSDE-15-CDL or equivalent manufacturers mentioned in list of manufacturers
S&F in repair 12 Watt Square recessed mounted down lighter with high luminous LED for indoor application,230 volts ,50 Hzs ,min 100 lm /watt with all accessories and connection to the electric circuit. complete all as specified Cat Part No - LSDE-12-CDL or equivalent manufacturers mentioned in list of manufacturers
S&F in repair 15 Watt recessed round down lighter with high luminous LED for indoor application,230 volts ,50 Hzs ,min 100 lm /watt with all accessories and connection to the electric circuit. complete all as specified and direted Cat Part No - LCDE-15-CDL or equivalent manufacturers mentioned in list of manufacturers
S&F in repair 12 Watt recessed round down lighter with high luminous LED for indoor application,230 volts ,50 Hzs ,min 100 lm /watt with all accessories and connection to the electric circuit. complete all as specifiedCat Part No - LCDE-12-CDL of crompton or surya / havells.
S&F in repair 12 Watt surface mounted round down lighter with high luminous LED for indoor application,230 volts ,50 Hzs ,min 100 lm /watt with all accessories and connection to the electric circuit complete all as specified and directed Cat Part No - LCSR-12-CDL or equivalent manufacturers mentioned in list of manufacturers
S&F in repair dimmable cob light light 7 watt 50 hz,230 volts with all accessories and connection to the electric circuit complete all as specified and directed Cat Part No - LCOBD07 or equivalent manufacturers mentioned in list of manufacturers
S&F in repair dimmable cob light light 12 watt 50 hz,230 volts with all accessories and connection to the electric circuit. complete all as specified Cat Part No - LCOBD12 or equivalent manufacturers mentioned in list of manufacturers
S&F in repair Ceiling light in Dome series 18 watt round 18 watt 50 hz,230 volts with all accessories and connection to the electric circuit. complete all as specified Cat Part No - LCL18R or equivalent manufacturers mentioned in list of manufacturers
S&Fin repair indoor wall mounted light 12 watt ,140 volt to 265 volts,IP-20 ,50 Hz ,aluminium housing with all accessories and connection to the electrc circuit complete all as specified and directed Cat Part No -LWL105 or equivalent manufacturers mentioned in list of manufacturers
S&F in repair mirror light 18 watt 50 hz,230 volts with all accessories and connection to the electric circuit. complete all as specified and directed Cat Part No - LMCL18 of Luker or equivalent manufacturers mentioned in list of manufacturers
S&F in repair mirror light 12 watt 50 hz,230 volts with all accessories and connection to the electric circuit. complete all as specified and directed Cat Part No - LMCL12 or equivalent manufacturers mentioned in list of manufacturers
S&F in repair Nickel plated mild steel clamps, Nuts, Bolts, Washers and split pin suitable for ceiling fans any type, any make, any size complete all as specified and directed.
S&F in repair Down rod, suitably threaded and holed, made out of 15 mm dia GI tubes, duly painted, 2' long, suitable for ceiling fans any type, any make, any size complete all as specified and directed.
All as per item No 72 here-in-before but 3' long complete all as specified and directed.
All as per item No 72 here-in-before but 5' long complete all as specified and directed.
S& F repair copper conductor multistranded cable flexible 03 core PVC insulated of size 40/0.076 at site/MES store yard complete all as specified and directed.
S&F in repair Fan canopy with tightening screw/check nut, made out of PVC, suitable for ceiling fans any type, any make, any size complete all as specified and directed.
S&F in repair Rubber reel insulator, suitable for ceiling fans any type, any make, any size complete all as specified and directed.
M&L in repair for hanging hook for ceiling fan with nuts bolts and washer min thickness 5 mm complete all as specified and directed.
Taking down unserviceable ceiling fan of 1200mm/1400mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking / heating up the motor to achieve the proper insulation resistance and re-hanging / refixing after repair including applying a coat of synthetic enamel paint (Glossy Finish) with spray gun, marking MES No complete all as specified and directed.
All as per item No. 79 here-in-before but exhaust fan of 450/300/250 mm sweep complete all as specified and directed.
All as per item No 79 here-n-before but wall mounted fan of 400 /450 mm sweep complete all as specified and directed.
All as per item No 79 here-in-before but pedestal fans 600 /400 mm sweep complete all as specified and directed.
All as per item No 79 here-in-before but industrial air circulator fans of any sizes complete all as specified and directed
M&L in repair Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron wire 4 mm dia as earth up to 7.5 m distance and connected by means of bolts, nuts, checknuts and washers of galvanised iron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10 CM c/c , 20 mm bore medium grade watering pipe, water funnel, 15 mm bore GI light grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion complete all as specified and directed. Note :- (i) The unit rate includes for protection pipe and earth lead upto 7.50 Mtr. (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately.
M&L in repair earthing complete with galvanised steel earth plate elctrode 60 x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 25 x 4 mm as earthing lead by means of bolts nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.point 3 connected to earthing test point all as specified or indicated including testing on completion.
S&F in repair Modular Bell push 6A, 1module, complete all as specified and directed.
S&F in repair Fan Regulator, modular electronic rotary,0-4 steps step type 100 Watt, 240 Volt 50 Hz hum free 2 module complete all as specified and directed.
S&F in repair switch modular 6 Amps 240 Volts one way switch complete all as specified and directed.
S&F in repair Socket 6 Amps AC 240 Volts 2/3 pin combined 2 modular type complete all as specified and directed.
S&F in repair Socket 6A/16 Amps-2/3 pin combined AC 240 Volts modular type complete all as specified and directed.
S&F in repair Switch modular type AC 240 volts 16 Amps one way complete all as specified and directed.
S&F in repair sunken box with Modular white cover plate 2 module with removing old type sunken boxes /wooden board and match with existing surfaces complete all as specified and directed.
S&F in repair sunken box with Modular white cover plate 3 module with removing old type sunken boxes /wooden board and match with existing surfaces complete all as specified and directed.
S&F in repair sunken box with Modular white cover plate 4 module with removing old type sunken boxes /wooden board and match with existing surfaces , complete all as specified and directed.
S&F in repair sunken box with Modular white cover plate 6 module with removing old type sunken boxes /wooden board and match with existing surfaces , complete all as specified.
S&F in repair SPN enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable eath plug complete all as specified.
S&F in repair triple pole enclosure with three pin and earth plug and socket complete with one TP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable eath plug complete all as specified.
S&F in repair triple pole enclosure with three pin and earth plug and socket complete with one TP MCB, 32 Amps having breaking capacity 10 kA, including taking down old unserviceable eath plug complete all as specified.
S&F in repair triple pole enclosure with three pin and earth plug and socket complete with one TP MCB, 63 Amps having breaking capacity 10 kA, including taking down old unserviceable eath plug complete all as specified.
S&F in repair XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 6 sq.mm 2 core including taking down old unserviceable cable complete all as specified and directed.
S&F in repair XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 10 sq.mm 4 core including taking down old unserviceable cable complete all as specified.
S&F in repair XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 16 sq.mm 4 core including taking down old unserviceable cable complete all as specified.
S&F in repair circular highbay LED light 80 Watt, 240 volt, min lmumens 110 Lm/w, IP 66 including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and directed.Cat Part No -LHB11-80-CDL/60-M or equivalent manufacturers mentioned in list of manufacturers
S&F in repair LED cercullar Flood Light 30 Watt,50 Hz,220 volts having IP-66 protection, pressure die cast aluminium housing, high luminious efficiancy and high power complete all as specified and directed Cat part no-LFLR30 or equivalent manufacturers mentioned in list of manufacturers
S&F in repair LED Flood Light 50 Watt,50 Hz,220 volts having IP-66 protection, pressure die cast aluminium housing, high luminious efficiancy and high power complete all as specified and directed.Cat part no-LFLR50 or equivalent manufacturers mentioned in list of manufacturers
S&F in repair LED building security light 45 watts ,50 Hz,220 volts having IP-65 protection, pressure die cast aluminium housing, high luminious efficiancy and high power complete all as specified and directed.Cat part no- ENDURAPEARLNEOSL40WLED757PASYTOPC or equivalent manufacturers mentioned in list of manufacturers
S&F in repair LED building security light 60 watts ,50 Hz,220 volts having IP-65 protection, pressure die cast aluminium housing, high luminious efficiancy and high power complete all as specified.Cat Part No-ENDURAPEARLNEOSL60WLED757PASYTOPC or equivalent manufacturers mentioned in list of manufacturers
S&F in repairs energy efficient ceiling fan of 1200mm sweep (5 star rated) 230 Volt, 50 Hz including all electrical connection all as specified and as directed and taking down old one and deposited with MES store yard. Make : Havells-Cat Part No. ES-40 / Crompton-Cat Part No. Entrust 50 / Usha. or equivalent manufacturers mentioned in list of manufacturers
S&F in repair PVC body exhaust fan motor suitable for 250/300 mm of any make as per site requirement all as specified and directed.
S&F in repair exhaust fan motor suitable for metallic body exhaust fan of any make as per site requirement all as specified and directed.
S&F PVC body wall fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting. Make : HavellsCat Part No. Girik or equivalent manufacturers mentioned in list of manufacturers
S&F 250mm sweep, PVC body exhaust fan heavy duty, single phase 230 volts, all as specified & directed. Make : HavellsCat Part No. Ventil Air-DX white or Crompton Cat Part No EXHD300-4-1 / Bajaj. Note : Old fan will be deposited in MES store yard.
Attending complaint including transportion of tools for rectification of urgent nature of electrical complaints like checking of existing electrical items for continuous electric supply including carrying out minor repairs such as checking of voltage calibration,checking of variation of R Y B phase in LT panel/DBs ,changing of MCBs, small pieces of wires including connections etc carrying out repairs such as tightening of loosen electric connections, nuts, bolts, screws of switches, sockets, switch boards, making joints and covering with PVC tape, minor repairs to ceiling fans / exhaust fans like repair of capacitors, cleaning and oiling etc. as required to make the electrical items/ appliances fully functional at C And D area at Naval Base during off hours (1700 hrs evening to 0900 Hrs morning ) on all working days including sunday and Holidays complete all as specified and directed by Engineer-in-Charge. NOTE:- (i) The contractor should display contact number at complaint cell to register users complaint. (ii) The recovery of rupees 400 per complaints will be charged if contractor failed to attend that instipulated time period as directed by Engineer-in-Charge. (iii) Number of complaints may vary day to day and shall be on required basis. Contractor shall quote their rates accordingly.including in all aspects like labours,tool,transportation etc.
M&L for checking of ceiling fans stability (like fan hooks,nuts, bolts ,hanging rod ,canopy ,washer etc ) exhaust fan stability ,loose connection in destribution boards,MCBs in C & D Area at Naval base all as specified and directed by engr in charge. Note: - 1. The contractor should prepare a register and enter office name with signature of offce incharge and submited to engineer in charge office. 2. Checking of 7 fans and 2 DBs of any type at a time shall be considered as one job.
M&L for checking of faulty / jumped energy meter (three phase /single phase) with fixing of new energy meter in series and after one week submmitted meter reading report of both energy meter in engr in charge office complete all as specified and directed.
M&L in repair aluminium strip 25 x 3.15 mm with porcelain insulators,saddles and fixing screws etc for roof conductor and down conductor above ground complete all as specified and directed.
M&L in repair air termination single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
M&L for test point terminal block made of gunmetal of size 75x75x25mm drilled and screened including all fixing arrangements with hexagonal headed screws and taking down old ones complete all as specified and directed.
M&L for Checking of earthing resistence and E-N voltage with caliberated earth tester meter and multimeter including recharging of conventional earthing of lightening arrestor of building /workshop/hanger /OTM etc at Naval Base Kochi complete with chemical , maintaining the earth testing record,rectification of earthing related fault also as per user signature and JE E/M verified by Engineer in charge complete all as specified and directed..
M&L in repair galvanised steel strip 32mmx6mm complete with,protection sleeves, saddles,seprator and fixing screws at surrounding inside and outside the bldg. directed as per engineer in charge.
M&L in repair galvanised steel strip 25mmx4mm complete with,protection sleeves, saddles,seprator and fixing screws at surrounding inside and outside the bldg. directed as per engineer in charge.
M&L in repair of eathing chamber of any type any size with necessory pcc work required with smooth surface duly coloured after repair work and cover of the size of the earth pit comple all as specified and directed.
S&F in repair 4mm dia galvanised iron or steel wire burried in ground fixed on walls and connected to main earth strip including excavation and earth work ,refilling etc. compete all as specified and as directed.
S&F in repair for rigid non metalic PVC medium grade conduit including junction boxes, tee, bends, elbows, reducers bell mouth tube ends,fixing accessories such as couplers, lock Nuts, saddle pipe hook etc for 25 mm dia complete all as specified and directed.
S&F in repair recess mounted/surface mounted commercial luminaire 36 watt ,50 Hz ,220 volts,5700 K LED down lighter 2'x2' , complete all as specified and directed Cat Part No -VENUSNEOHE2X2R36WLED857PIRSENSOR or equivalent manufacturers mentioned in list of manufacturers
S&F in repair SS enclosure suitable for MCCB 100-200 amp complete all as specified and directed.Make L & T cat CM91003OOOO or equivalent manufacturers mentioned in list of manufacturers
S&F in repair MCCBs FP 63 Amps thermal magnatic 25 kA complete all as specified and directed, Make L & T Cat No CM91712OOJOOG or equivalent manufacturers mentioned in list of manufacturers
S&F in repair MCCBs FP 100 Amps thermal magnatic 25 kA complete all as specified and directed, Make L & T Cat No CM90642OOLO or equivalent manufacturers mentioned in list of manufacturers
S&F in repair MCCBs FP 160 Amps thermal magnatic 25 kA complete all as specified and directed.
S&F in repair MCCBs FP 200 Amps thermal magnatic 25 kA complete all as specified and directed.
S&F in repair bed side Lamp 3 watt 50 hz,230 volts,3000k with all accessories and connection to the electric circuit. complete all as specified Cat Part No -48042 or equivalent manufacturers mentioned in list of manufacturers
S&F in repair Suspened LED lighting solution with 52 mm width and 75 mm height 24 watt watt 230V,50 Hz, including connected accessories including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and directed. Cat Part No -CCP-121-24-40-SL-NWH of Crompton or equivalent manufacturers mentioned in list of manufacturers
S&F Flame proof/ Weather proof LED tube light fitting (4 feet) suitable for 1 x 20 watt with glass & connector suitable for LED tube light with all accessories prewired, product in Al. die cast alloy LM6 construction of Gas Gr. IIA, IIB certified by CIMFR dhanbad &CCOE(PESO) Nagpur along with ISI marking including testing complete all as specified and directed including taking down of existing fitting. : Make Crompton part No EXTN1LT8-16/20 or equivalent manufacturers mentioned in list of manufacturers
S&F Flame proof/ Weather proof LED tube light fitting (4 feet) suitable for 2 x 20 watt with glass & connector sutable for LED tube light with all accessories prewired, product in Al. die cast alloy LM6 construction of Gas Gr. IIA, IIB certified by CIMFR dhanbad &CCOE(PESO) Nagpur along with ISI marking including testing complete all as specified and directed including taking down of existing fitting. Make : Crompton part No EXTN2LT8-16/20 or equivalent manufacturers mentioned in list of manufacturers
S&F FLP rotary switch single pole 16 Amps and fixing arrangement including taking down of existing FLP swtich complete all as specified and directed. Make Cat Part No: Sudhir switch Gear RI/OA/1010-2A or equivalent manufacturers mentioned in list of manufacturers
N.O. Antony Contractors
HEAVEN ENGINEERS AND CONTRACTORS
K A ANTONY & SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .