Tender Value
₹24.7 L
EMD Value
₹49,400
Closing Date
22 Dec 2020, 6:00 pmClosed
GARRISON ENGINEER (NW) KOCHI
KATARIBAGH, NAVAL BASE POST, KOCHI-682004.
COMPREHENSIVE MAINTENANCE AND PETTY REPAIRS OF INTERNAL WIRING, ELECTRICAL FITTINGS AND FIXTURES OF B, C AND D AREAS AT NAVAL BASE KOCHI
2020_MES_398060_1
GE(NW)KOCHI/8475/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (NW) KOCHI
₹49,400
Yes
22 Feb 2021
25 Nov 2020
24 Dec 2020
25 Nov 2020
22 Dec 2020
9 Dec 2020
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendents, regulators. sockets etc to be measured separately) and making good the disturbed surfaces of walls. floors etc to match with the existing all as specified and directed.
Material and labour for point wiring with 1. 5 Sqmm PVC insulated (FRLSH) sheathed multistranded single core copper conductor cable in PVC casing and caping of suitable size and including 2mm thick MS sheet pressed terminal box (concealed) with 3mm thick laminated hylam top cover/sunken box with modular cover plate/PVC box as per requirement at site including 1.5 Sqmm PVC insulated (FRLSH) multistranded copper conductor earth continuity wire for one light/fan point controlled by one 5 Amp switch on independent board all as specified and as directed by the Engineer-in-Charge. Note : Red/yellow/blue coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
All as per item No.2 above, but one bell point controlled by one bell push on independent board.
All as per item No.2 above, but one 5 pin 5 Amps socket outlet on independent board.
All as per item No 2 above but with 2.5sqmm PVC insulated unsheathed stranded copper conductor with 2.5 sqmm PVC (FRLSH) insulated stranded copper wire for continuous earthing for one 5 pin 15 amps socket outlet point on independent board
S&F in repairs, bell push, flush type, 5 Amps, single pole complete all as specified and directed.
S&F in repairs, electric bell, 230 volt, flush type, 5 Amps, single pole complete all as specified and directed.
S & F in repairs switch piano flush type 5 Amps SP one way all as specified and directed.
S & F in repairs switch piano flush type 15 Amps SP one way all as specified
S & F in repairs, socket outlet, 5 Amps, 5 pin, 2 in 1, all as specified and as directed by the Engineer-in-Charge
S & F in repairs, socket outlet, multi-purpose, 5 and 15 Amps, 5 pin, 2 in 1, all as specified and as directed by the Engineer-in-Charge
S & F in repairs, switch socket outlet combination, 5 Amps, 5 pin, 2 in 1, all as specified and as directed by the Engineer-in-Charge
S & F in repairs, switch socket outlet combination, 5 and 15 Amps, 5 pin, 2 in 1, all as specified and as directed by the Engineer-in-Charge
S & F in repairs,step type electronic fan regulator, flush type, 100 W, 230 V all as specified and directed
S & F in repairs, capacitor 2.5 MFD for ceiling fans, all as specified and directed
S & F in repairs, lamp holder, PVC/Ploycarbonate type with back plate suitable for batten fittings, all as specified and directed
S & F in repairs, ceiling rose surface bakelite 65 x 50mm, 3 terminals all as specified and as directed by the Engineer-in-Charge
M&L in repairs for submain wiring with 4 runs of 10 Sqmm PVC insulated unsheathered multi stranded FRLSH copper conductor cable and one run of 10 Sqmm cable as earth continuity wire in and including PVC casing and caping and making good the disturbed surface to match with exisitng surface all as specified. Note : (i) Five runs of 10 Sqmm PVC cable and one run of PVC casing and caping will be measured as one unit length.(ii) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
M&L in repairs for submain wiring with 2 runs of 4 Sqmm PVC insulated unsheathered multi stranded FRLSH copper conductor cable and one run of 4 Sqmm cable as earth continuity wire in and including PVC casing and caping and making good the disturbed surface to match with exisitng surface all as specified. Note : (i) Three runs of 4 Sqmm PVC cable and one run of PVC casing and caping will be measured as one unit length.(ii) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
All as per item No 19 above but with 2 runs of 2.5sqmm PVC insulated unsheathed stranded copper conductor with 2.5 sqmm PVC (FRLSH) insulated stranded copper wire for continuous earthing.
M&L in repairs for submain wiring with 4 runs of 16 Sqmm PVC insulated unsheathered multi stranded FRLSH copper conductor cable and one run of 16 Sqmm cable as earth continuity wire drawn through and including ISI marked, medium grade, non-metalic PVC conduit, white colour and all accessories and making good the disturbed surface to match with exisitng surface all as specified. Note : (i) Five runs of 16 Sqmm PVC cable and one run of PVC conduit will be measured as one unit length.(ii) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
S & F in repairs triple pole and neutral sheet metal enclosure for MCB DB 8 ways, double door, 240 V, with 200 Amps bus bar having IP-43 protection complete all as specified
S & F in repairs single pole and neutral sheet metal enclosure for MCB DB 8 ways, double door, 240 V, with 200 Amps bus bar having IP-43 protection complete all as specified
S & F in repairs single pole and neutral sheet metal enclosure for MCB DB 4 ways, double door, 240 V, with 200 Amps bus bar having IP-43 protection complete all as specified
S & F in repairs, MCB TPN 63 Amps, 415 V, B curve, having breaking capacity 10 KA complete all as specified and directed.
S & F in repairs, MCB TP 63 Amps, 415 V, B curve, having breaking capacity 10 KA complete all as specified and directed.
S & F in repairs, MCB TPN 32 Amps, 415 V, B curve, having breaking capacity 10 KA complete all as specified and directed.
S & F in repairs, MCB SPN 63 Amps, 415 V, B curve, having breaking capacity 10 KA complete all as specified and directed.
S & F in repairs, MCB SP, 6-32 Amps, 415 V, B curve, having breaking capacity 10 KA complete all as specified and directed.
S & F in repairs, MCB SPN, 6-32 Amps, 415 V, B curve, having breaking capacity 10 KA complete all as specified and directed.
S & F in repair 20 watt LED tube double side with batten , 230V,50 Hz,wall surface ,roof surface including connected accessories including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and directed.(Note: Fitting shall be as per cat part no -,LGT8-20-865-2(Tube) and DIJB12LT8-20(Batten) of Crompton or equivalent make of Philips/Surya/Havellls) .
S & F in repair Led glass T8 tube 20 watt, 220 volt ,50 Hz instant LED tube rod, double side connection,inbuilt driver , complete all as specified.(Note: Fitting shall be as per cat part no -LGT8-20-865-2 of Crompton or equivalent make of Philips/Surya/Havells) .
S & F in repair LED light fitting 20 W, high performance batten , 220 volt ,50 Hz, surface mounted high quality aluminium extruded with all connecting accessories ,with suitable connection complete all as specified.(Note: Fitting shall be as per cat part no-LDL-20-CDL of Crompton or equivalent make of Philips/Surya/Havells .
S & F in repair LED light fitting 10 W, high performance batten , 220 volt ,50 Hz, surface mounted high quality aluminium extruded with all connecting accessories ,with suitable connection complete all as specified.(Note: Fitting shall be as per cat part no-LDL-10-CDL of Crompton or equivalent make of Philips/Surya/Havells) .
S & F in repair 15 watt square recessed mounted down lighter with high luminous LED for indoor application, 230V,50 Hz, minimum 100 lm/watt with all accessories and connection to the electric circuit complete all as specified and directed.(Note: Fitting shall be as per cat part no -LSCSM-15W-CDL of Crompton or equivalent make of Philips/Wipro) .
S & F in repair 15 watt recessed round down lighter with high luminous LED for indoor application, 230V,50 Hz, minimum 100 lm/watt with all accessories and connection to the electric circuit complete all as specified and directed.(Note: Fitting shall be as per cat part no -LSCRM-15W-CDL of Crompton or equivalent make of Philips/Wipro) .
S&F in repairs, focus light 07 watt ,230 volts,50 Hz, with all accessories and connection to the electric circuit complete all as specified .(Note: Fitting shall be as per cat part no -LSP07 of lukar or equivalent make of Philips/Crompton/Wipro).
M & L in repair Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron wire 4mm dia as earth up to 7.5 m distance and connected by means of bolts, nuts, checknuts and washers of galvanised iron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC 1:3:6 type C1 pit , RCC 1:2:4 type B1cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10 CM c/c , 20 mm bore medium grade watering pipe, water funnel, 40 mm bore GI medium grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion complete all as specified and directed. Note :- (i) The unit rate shall deem to include for protection pipe and earth lead upto 7.50 Mtr. (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately.
S & F in repair Modular Bell push 6A, 1module, complete all as specified.
S & F in repair Fan Regulator, modular electronic rotary,0-4 steps step type 100 Watt, 240 Volt 50 Hz hum free 2 module complete all as specified
S & F in repair switch modular 6 Amps 240 Volts one way switch complete all as specified.
S & F in repair Socket 6 Amps AC 240 Volts 2/3 pin combined 2 modular type complete all as specified.
S & F in repair Socket 6A/16 Amps-2/3 pin combined AC 240 Volts modular type complete all as specified.Make -Legrand/Havells/Honeywell.
S & F in repair Switch modular type AC 240 volts 16 Amps one way complete all as specified.
S & F in repair sunken box with Modular white cover plate 2/3 module with removing old type sunken boxes /wooden board and match with existing surfaces , complete all as specified.
S & F in repair sunken box with Modular white cover plate 4 module with removing old type sunken boxes /wooden board and match with existing surfaces , complete all as specified.
S & F in repair sunken box with Modular white cover plate 6 module with removing old type sunken boxes /wooden board and match with existing surfaces , complete all as specified.
S & F in repair sunken box with Modular white cover plate 8 module with removing old type sunken boxes /wooden board and match with existing surfaces , complete all as specified.
S & F in repair sunken box with Modular white cover plate 12 module with removing old type sunken boxes /wooden board and match with existing surfaces , complete all as specified.
S & F in repair SPN enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable eath plug complete all as specified.
S & F in repair triple pole enclosure with three pin and earth plug and socket complete with one TP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable eath plug complete all as specified.
M & L in repair XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 6 sq.mm 2 core including taking down old unserviceable cable complete all as specified.
M & L in repair XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 10 sq.mm 4 core including taking down old unserviceable cable complete all as specified.
M & L in repair XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, cross-sectional area 16 sq.mm 4 core including taking down old unserviceable cable complete all as specified.
S & F in repair Blaze highbay Led light 80 Watt ,240 volt , min lmumens 110 Lm/w ,IP 65 including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and directed.
S & F in repair 80 Watt LED Flood Light having IP-66 protection, 220 volts ,50Hz,pressure die cast aluminium housing, high luminious efficacy and high power complete all as specified.
M & L for checking of faulty / jumped energy meter (three phase /single phase ) with fixing of new energy meter in series and after one week submmit meter reading report of both energy meter in Engineer-in-Charge office all as specified and directed by Engineer-in-Charge.
Supply & fix in repairs, recess mounted/surface mounted commercial luminaire 36 watt ,50 Hz ,220 volts,5700 K LED down lighter 2'x2' , all as specified and directed of Crompton ,Philips ,Havells
Material and labour including transportion of tools for rectification of urgent nature electrical complaints like checking of electrical items for continuous electric supply including carrying out minor repairs such as changing of MCBs, small pieces of wires including connections etc, carrying out repairs such as tightening of loosen electric connections, nuts, bolts, screws of switches, sockets, switch boards, making joints and covering with PVC tape, monor repairs to ceiling fans/exhaust fans like replacement of capacitors, cleaning and oiling etc as required to make the electrical items/appliances fully functional at Ellison avenue, Sanjivani hospital, Shopping complex, SNCO mess area, NSRY area during off hours (1700 hrs evening to 0900 hrs morning) on all working days all as specified and directed by Engineer-in-Charge. Notes:- 1. Materials incorporated for completion of the work will be measured and paid separately under relevant items. 2. The contractor should display contract number at complaint cell to register complaints by the users. 3. A recovery of Rs.400/- per complaint will be levied from the contractor on failure in attending the complaint within the stipulated time.
Material and labour including transportion of tools for rectification of urgent nature electrical complaints like checking of electrical items for continuous electric supply including carrying out minor repairs such as changing of MCBs, small pieces of wires including connections etc, carrying out repairs such as tightening of loosen electric connections, nuts, bolts, screws of switches, sockets, switch boards, making joints and covering with PVC tape, monor repairs to ceiling fans/exhaust fans like replacement of capacitors, cleaning and oiling etc as required to make the electrical items/appliances fully functional at Ellison avenue, Sanjivani hospital, Shopping complex, SNCO mess area, NSRY area during off days including Sundays and Holidays all as specified and directed by Engineer-in-Charge. Notes:- 1. Materials incorporated for completion of the work will be measured and paid separately under relevant items. 2. The contractor should display contract number at complaint cell to register complaints by the users. 3. A recovery of Rs.400/- per complaint will be levied from the contractor on failure in attending the complaint within the stipulated time.
S&F indoor wall light 14 Watt, 220 Volts, 50 Hz, cool white type, suitable for wall surface and with connection complete all as specified and directed. Note: Fitting shall be as per Cat Part No.LWL114-2 of Luker or equivalent make of Crompton/Philips/Surya.
S&F indoor wall light 7 Watt, 220 Volts, 50 Hz, cool white type, suitable for wall surface and with connection complete all as specified and directed. Note: Fitting shall be as per Cat Part No.LWL114-1 of Luker or equivalent make of Crompton/Philips/Surya.
S&F indoor wall light 14 Watt, 220 Volts, 50 Hz, cool white type, suitable for wall surface and with connection complete all as specified and directed. Note: Fitting shall be as per Cat Part No.LWL112-2 of Luker or equivalent make of Crompton/Philips/Surya.
S&F indoor wall light 7 Watt, 220 Volts, 50 Hz, cool white type, suitable for wall surface and with connection complete all as specified and directed. Note: Fitting shall be as per Cat Part No.LWL112-1 of Luker or equivalent make of Crompton/Philips/Surya.
S&F indoor wall light 12 Watt, 220 Volts, 50 Hz, warm white type, suitable for wall surface and with connection complete all as specified and directed. Note: Fitting shall be as per Cat Part No.LWL105 of Luker or equivalent make of Crompton/Philips/Surya.
S&F in repair aluminium strip 25x3.15mm with porcelain insulators, saddles and fixing screws etc for roof conductor and down conductor above ground all as specified and directed.
S&F in repair air termination single pointed aluminium rod 12mm dia and 300mm long all as specified and directed.
S&F in repair test point terminal block made of gun metal of size 75x75x25mm, drilled and screwed including all fixing arrangements with hexagonal headed screws all as specified and directed.
Equipment and labour for testing of earth resistance of existing earthing of lightening arrestor of building/workshop/hanger/OTM etc at Naval Base Kochi.
S&F in repairs 36 watt LED PLL lamp by disconnecting and removing the old choke and starter from the existing fitting with necessary intrnal wiring from holder to terminal box inside the fitting complete all as specified and directed. Make: Crompton, Havells, Bajaj, Wipro
S&F in repairs LED aviation obstruction light luminairs comprising of aluminium housing, LED bulb, polycarbonite enclosure complete all as specified and directed. Make: Crompton, Havells, Bajaj, Wipro
Sreema Enterprises
P N Enterprises
N.O. Antony Contractors
M/s T.P SHAJI
Green Ray Enterprises
Jyothis Enterprises
S L ELECTRICAL WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .