| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-PreQual/Technical 1ST FLOOR SIDHARTH TOWER BALTI KHARKHANA BYELNE S J ROAD ATHGAON GUWAHATI KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | Not Admitted-PreQual/Technical Others-tender fee and emd not recevied |
| 5 | Rejected-Technical 00 INFRONT OF S R K PG COLLEGE KOTLA ROAD OM MARKET FIROZABAD UTTAR PRADESH 283203 | FIROZABAD | UTTAR PRADESH | 283203 | Rejected-Technical Not qualified |
Tender Value
₹27.5 L
EMD Value
₹27,540
Closing Date
27 Jan 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EWC
Katju Marg, Bareilly
Increasing capacity of 33/11kv S/S Barkhera from 1x5 MVA to 2x5 MVA and its 11 kv link line in district Pilibhit
2023_MVVNL_766519_1
19/EWC(B)/2022-23
Open Tender
Electrical Works
Item Rate
90 days
Pilibhit
As per tender document
3 documents required · 3 mandatory
₹3,540
A/c No. 019205006347, IFSC Code ICIC0000192
₹27,540
30 Jan 2023
12 Jan 2023
27 Jan 2023
12 Jan 2023
27 Jan 2023
12 Jan 2023
Amount
Note - Any material/Labour required to complete the work (which is not covered in above) will be provided by the firm.
Part (A) INCREASING CAPACITY
Loading, unloading and safe carriage of the following materials from any Electy. Store Center of Electricity store division of Bareilly zone.
M.S. Channel 125x65x5 mm @ 13.1 kg./mtr.
M.S.Angle 75x75x8 mm @ 8.9 kg./mtr.
MS Angles 50x50x6mm @ 4.5 Kg/Mtr.
33 KV Post insulator
33 KV Lightening Arrestor
33 KV VCB 800A 750 MVA
33 KV I/C control pannel for single T/F
33 KV O/D CT CTR 200/100/1
11 KV VCB I/C CTR 600/300/5A 250 MVA 630 A
11 KV VCB O/G CTR 200/100/5A 350 MVA
11 KV Cable 3x300 Sq. mm XLPE
11 KV Cables 3x185 Sq. mm XLPE
11 KV Cable Jointing Kit
ACSR Dog conductor
Earthing of indoor & outdoor equipments of Sub-Station after proper welding of joints and painting of earth strip above soil with proper clamp etc. as per RESSPO approved drawing & resistance of earthing should be not more than 2Ω as per details given below.
Making of triangular bridge by using MS electrode, GI strip 50x6mm and GI Pipe 40 mm dia with providing of well type pipe earthing upto 15 Mtr. depth below ground level including welding etc. by boaring process at T/F neutral, LA and newly erected structure including cost of GI pipe of size 40 mm dia 15 mtr. long of ISI mar(all the required material will be supllied by the contractor).
Supply of GI strip of size 50x6mm for earthing of all newly erected structures and equipments in switchyard including cutting, fixing & proper welding with equipments. All LA will be seprately earth also as per RESPO norms. (All the required materials will be provided by firm.)
Fabrication, erection and grouting of the following structures as per RESSPO/ Approved Drawing and its, plinth 30cm above ground leval as directed by the Engineer Incharge (All steel sections will be provided by Deptt).
Lightening Arrestor Structure
33 KV VCB Structure
33 KV CT Structure
Fuse Set Structure
Post insulator Structure
Installation of followig equipments on their respective structures including mechanical & electrical fixing after proper adjustment on their structure.
Lightening Arrestor (will be provided by Deptt).
33 KV VCB complete (will be provided by Deptt.)
33 KV CT (will be provided by Deptt.) (03 Nos)
33 KV Fuse Set (will be provided by firm)
33 KV Post insulator (will be provided by Deptt.)
24 V Battery set with charger ( To be provided by firm I.S.I. mark only of DC System with one float cum boost charger & battery set for 24V. System with 200A.H. Capacity with cabinet).
Complete laying and termination of copper control cables from 5 MVA power T/F, 33 KV VCB, 33 KV CT in the out door switch yard to the Transformer relay control panel inside the control room including cost of all materials and labour required for proper completion of works as per RESSPO drawings, including cost of testing of transformer, VCB, CT, relay pannel & proper relay settings as per requirement etc.
Laying of dog conductor alongwith cost of all required calmps and connectors etc. as per RESSPO Approved drawing of L.A., C.T., V.C.B., Bus Isolator etc.
Making of M.S. Angle Ladder type frame of Angle (75x75x8mm) & M.S. Strip (50x6mm) near power transformer for power cable with concreting of the same in the ground and proper clamping (50x6mm) of the same with transformer cable.
Making of M.S. Angle frame of (75x75x8mm) in L shape to connect T/F Neutral by flexible copper strip including cost of copper strip & will be connected to newly constructed well type earthing for Power T/F Neutral as per RESPO norms.
Laying of 11KV cable of different size from power T/F to control room I/C and control room to outside D/P. 11 KV Cable will be layed in brick trench constructed below 750mm to the ground level over the ganga sand. brick trench will be constructed by Ist class bricks covering three sides of cable, after laying 11 KV Cable brick trench will be filed by Ganga sand & then will be covered by bricks & backfill of soil over cable trench as per RESPO norms.
Erection of 11 KV incoming, outgoing and Bus coupler panels (with testing & setting of relays) in substation control room including grouting of Anchor bolts of panel and making of pocket for power cable to insert in panel from trench and complete filling of control room's tranches by river sand.
Erection & testing of 1 No. single T/F Control penel in substation control room including grouting of anchor bolts of panel and making of pocket for control cable to insert in panel from trench and complete filling of control room's tranches by river sand.
Termination of 11 KV 3x300sqmm size XLPE cable by filling 11 KV heat shrinkable type cable boxes including proper connection with LV side of transformer to switch gear panels by providing suitable connectors.
Termination of 11 KV 3x185sqmm size XLPE cable by filling 11 KV heat shrinkable type cable boxes including proper connection with LV side of switch gear panels to double poles out side S/S by providing suitable connectors.
Hoisting of 11 KV Cable on DP in GI Pipe.
Painting of the fabicated structures with one coat of red oxide primer and two coats of synthetic enamel alumm. Paint/green paint of ISI Mark alongwith earthing strip above ground level.
Shifting and dragging of 33/11 KV 5 MVA transformer from road side to its plinth alongwith its erection including fixing of all assessories and top-up of T/F oil.
Shifting and dragging of 33/11 KV 5 MVA transformer (Damage) from its Plinth to safe site in switchyard alonng with its proper diconnection of earthing strip, poewr & control cable connection without any damage.
Repairing and replacement of damage gasket, Bushing rod, Bushing .Breather,Silica gel etc by repalcement. (In case of old & used 5 MVA T/F)
Repairing of 01 No. Bus Isolator including replacement of its damage Jaws, blades etc.
Centrifusing of transformer oil in case of old & used power transformer.
Providing of Rubber matting sheet 8/10mm of good quality as per standard specification.
Complete repairnig of swichyard fencing.
Part (B) 11 kv line
Carriage of following line material for 11KV line from Store Centre to the site of work including measuring, weighing, loading, unloading at both ends and proper stacking at safe site.
STP 11Mtr. long
PCC pole 8.5Mtr. Long
11 KV Cross Arm Channel V type
11 KV Pin insulator
11 KV Pin with nut
11 KV Disc insulator
11 KV Disc fitting
ACSR weasal conductor
11 KV 3X185mm XLPE Cable
11 KV Cable Jointing Kit
G.I. wire 8 SWG
Stay set complete
Earthing complete
M.S angle lron 65x65x6mm, 2700mm long bracing
Gaurding Angle 1.6 Mtr.
MS Channel 125x65x1300mm (T-Off)
M.S.Channel 100X50x2240mm Top channel
Erection of the following supports including cutting, making holes, fixing of all types of accessories digging of pits complete in all respect, as per RESSPO drawing. All types of clamps,stone pad, nut, bolt washers would be provided by the contractor.
Single support of S.T pole 11 mtr long.
Single support of PCC pole 8.5 mtr long.
Double pole structure on S.T. Pole 11mtr long complete with bracing.
Double pole structure on PCC. Pole 8.5mtr long complete with bracing.
End type double pole on ST pole 11 Mtr. long complete with bracing
Concreting of supports at the time of erection of pole in 1:4:8 concrete ratio from bottom of pole to ground level and plinthing of supports upto 300mm above ground level by using cement, sand & coarse aggregate in ratio 1:4:8 as per RESSPO drawing with watering/curing properly upto proper setting of plinthing. All matrial would be provided by the contractor.
Erection of stay set with stay wire, stay clamp & stay insulator including with grouting of stay set by concrete of ratio 1:4:8 as per RESSPO norms before back fitting of the pits including binding, climbing, clamping, tightening and nozzeling of stay wire in all respect as per RESSPO norms. All clamps, nuts, bolts, stay insulator, cement. brick, ballast, sand etc would be provided by the contractor.
Laying and sagging of 3 phase ACSR Weasal conductor from double pole at 33/11 KV substation to double pole at tapping point of 11 KV feeder line including jumpering, hoisting, fixing of all type of insulators, binding, jointing and its clamping etc in all respect.
Earthing of each S.T Poles of the line is to be done by inserting the MS earth rod (1800x20mm) into soil by hammering and properly fastning with GI wire to each support by nut & bolt. Earthing rod must be 0.15Mtr.above from the plinth of the support. All type nut & bolt would be given by the contractor.
Earthing of each PCC Poles of the line is to be done by inserting the MS earth rod (1800x20mm) into soil by hammering and properly fastning with GI wire to each support by nut & bolt. Earthing rod must be 0.15Mtr.above from the plinth of the support. All type nut & bolt would be given by the contractor.
Guarding of HT/LT/Telephone Line/ Road/River Crossing etc. by providing G.S Earth wire 7/16 SWG/GI wire No. 8/10 and making net with difference of 1.00 Mtr. Completely including fixing of channel/angle etc. with proper locking at each support as per RESSPO norms. All type nut &bolts, would be given by the contractor.
Fixing of danger board and G.I barbed wire on each pole including proper clamping. All material would be provided by firm.
Write serial number on each pole in English with black paint in yellow paint background. All material would be provided be firm.
Cable laying by drill method in single circuit
Cable laying by drill method in HDPE Pipe single circuit
Cable laying by drill method in GI Pipe single circuit
Hoisting of 11 KV 3X185 Sq. mm. XLPE cable on double pole in GI pipe including its jumpering complete along with cost of A class GI pipe of size 6" dia 3 M long, clamps, nuts and bolts.
Fixing of 11 KV 3x185sqmm O/D & S/Th.
Fixing of 11 KV Cable Marker. (all material would be provided be firm.)
Making of triangular bridge by using MS electrode, GI strip 50x6mm and GI Pipe 40 mm dia with providing of well type pipe earthing upto 15 Mtr. depth below ground level including welding etc. by boaring process at railway crossing site including cost of GI pipe of size 40 mm dia 15 mtr. long of ISI mark.Earthing resistance shiold be not greater than 2 Ω.(all the required material will be supllied by the contractor).
Painting of following support of existing 11 KV line with one coat of red oxide primer and two coats of aluminium white paint of ISI mark and top danger portion of each support must be painted by providing two coat of Post Office Red Paint (1.5mtr upper portion of support.) Paint and material would be given by contractor to complete of work.
Single pole structure of 11 mtr. ST Pole.
Double pole structure of 11 mtr. ST Pole.
Clearing of the line route by cutting of tree branches during erection of line and also upto the time of energisation completely as per direction of site incharge.
NATIONAL CONTRACTOR & GENERAL ORDER SUPPLIER
M/S SUPER ENGINEERING TRADERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .