Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹5.5 L+₹29,134 (5.65%)Rejected-Finance HOUSE NO 43 VPO KOT DISTRICT PANCHKULA 134118 | PANCHKULA | PANCHKULA | HARYANA | 134118 | L2 | Rejected-Finance Highest |
Tender Value
₹4.2 L
EMD Value
₹8,340
Closing Date
6 Dec 2021, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Elect. Divn. PWD B and R Br. Ambala Cantt.
Renovation of Old Police Post, Hanger - 1 and 2 Nos., Partition Work in Workshop in Civil Aerodrome, Pinjore. (Pdg. E.I Only).
2021_HRY_197960_1
PWD/Elect-KNL/Elect-AMB/110205
Open Tender
Construction Works
Works
60 days
Ambala Cantt.
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹8,340
Yes
10 Feb 2022
30 Nov 2021
7 Dec 2021
30 Nov 2021
6 Dec 2021
30 Nov 2021
Amount
CEILING FAN/ EXHAUST FAN Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge. 48" (1200mm) HSR No. 20.71.1
Supplying, errection, testing of Exhaust fan (as per IS code 374) having a each capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge HSR No. 20.72
COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS Wiring only in 1.5 sqmm PVC insulated copper conductor cable for LIGHT/FAN/Call bell point in existing conduit pipe and MS boxes including cost of Bakelite cover for MS box, switch, wall socket, ceiling rose/connector etc. Group A HSR No. 23.5.1.1
Wiring in existing conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch etc complete as required Group A HSR No. 23.5.5.1
Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) HSR No. 23.5.6.1
1 run of Size 4 Sqmm(1/2.24mm) HSR No. 23.5.6.3
Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. HSR No. 23.7.6.2
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules including combined plate for Telephone and data HSR No. 23.8.10.1
4 Modules HSR No. 23.8.10.3
6 Modules HSR No. 23.8.10.4
12 Modules HSR No. 23.8.10.6
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch HSR No. 23.8.11.1
15 amp 1 way switch HSR No. 23.8.11.3
5 amp Socket HSR No. 23.8.11.4
15 amp 6 pin Socket HSR No. 23.8.11.5
Step type Fan Regulator 2 modules 300 watt HSR No. 23.8.11.7
Blanking plate HSR No. 23.8.11.10
Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as required HSR No. 23.2
MCCB ,DISTRIBUTION BOARDS, MCB's, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp HSR No. 23.22.1
Supply and erection of sheet steel enclosures 1 Pole / 2 pole / 4 pole on wall/on existing pedestal complete with necessary connections etc, :- S.P.N or D.P enclosure suitable for DP MCB HSR No. 23.22.3.2
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 12 way ( 2 incoming and 10 outgoing) HSR No. 23.22.4.3
TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) HSR No. 23.22.4.5
Supply and erection of miniature circuit Breaker/isolator 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole HSR No. 23.22.5.1
40 amp to 63 amp. Double pole HSR No. 23.22.5.4
40 amp to 63 amp. MCB's FOUR POLE HSR No. 23.22.5.8
Supply and erection of U- PVC Trunking/Channel of following size including cost of fixing on wall, floor and ceiling etc. with required material complete the job in all respect up to entire satisfaction of the Engineer-in-charge of work. 50x50 mm HSR No. 23.23.5.4
Supplying and drawing of 1 no UTP 4 pair CAT 6a LAN Cable in the existing surface/recess MS/PVC conduit as required HSR No. 23.23.10
Supply of aluminium armoured cable of size 10 Sq. mm 4 Core, Make as per approved list NS-1
M/S GARG ELECTRICAL
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .