Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAdmitted-Fee/PreQual/Technical/Finance CHENGALA PADINHARMOOLA HOUSE KUNDADUKKAM PIN 671541 | KUNDADUKKAM | KASARAGOD | KERALA | 671541 | ₹24.6 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹28.6 L+₹4.0 L (16.4%)Admitted-Fee/PreQual/Technical/Finance | ₹28.6 L+₹4.0 L (16.4%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | L3₹30.3 L+₹5.7 L (23.2%)Admitted-Fee/PreQual/Technical/Finance | ₹30.3 L+₹5.7 L (23.2%) | L3 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | SATHEESH A L1 | Baby NV L2 | Mathew V L3 |
|---|---|---|---|---|---|---|
| 1.00Solar Power Plant On Grid System | ||||||
| 1.00 | OD272938/2025-2026 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended,consisting of N-Type Bifacial modules up to 80 +-10% Bi-facialty factor solar cells, net metering facility, necessary protections(As per NEC), earthing, mounted on Aluminium/GI structure of suitable strength with following Components complete as required:- a) Solar Photovoltaic Module of capacity 550 Wp or above,manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2.Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV Modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-1000 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz,output voltage suitable to generate AC Power with efficiency not less than 97%,total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) connections &Interconnections by supplying &fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply | 40 | kW | 56,791.91 ₹22,71,676.24 Lowest | 68,000 ₹27,20,000 | 70,000 ₹28,00,000 |
| 2.00Civil works for Maintenance Ladder and platform | ||||||
| 2.00 | 50.10.1Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete | 915 | kg | 200.47 ₹1,83,433.48 | 150 ₹1,37,250 Lowest | 240 ₹2,19,600 |
| 2.00 | 13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work | 18.78 | sqm | 219.58 ₹4,124.33 Lowest | 300 ₹5,634.9 | 500 ₹9,391.5 |
Tender Value
₹26.4 L
EMD Value
₹50,000
Closing Date
6 Jul 2026, 3:00 pmClosed
The Chief Engineer, Sports Kerala Foundation
Jimmy George Indoor Stadium, Vellayambalam, Thiruvananthapuram
Solar Power Plant on Grid System, Civil works for Maintenance Ladder and platform
2026_SKF_857892_1
77/SKF/CE/2026-27
Open Tender
Electrical Works
Item Rate
120 days
Kannur
Please refer tender document
8 documents required · 8 mandatory
₹2,950
₹50,000
1 Aug 2026
27 Jun 2026
8 Jul 2026
27 Jun 2026
6 Jul 2026
27 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Solar Power Plant On Grid System | |||||
| 0.999 | OD272938/2025-2026 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended,consisting of N-Type Bifacial modules up to 80 +-10% Bi-facialty factor solar cells, net metering facility, necessary protections(As per NEC), earthing, mounted on Aluminium/GI structure of suitable strength with following Components complete as required:- a) Solar Photovoltaic Module of capacity 550 Wp or above,manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2.Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV Modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-1000 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz,output voltage suitable to generate AC Power with efficiency not less than 97%,total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) connections &Interconnections by supplying &fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply | - | kW | - | - |
| 2Civil works for Maintenance Ladder and platform | |||||
| 0.999 | 50.10.1Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete | - | kg | - | - |
| 0.999 | 13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work | - | sqm | - | - |
stage.html
html • 0.03 MB
finance_1450202.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.41 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
BOQ_1450202.xls
BOQ • 0.23 MB
Tenderdoc.pdf
Tender Documents • 1.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .