| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75.7 LAccepted-AOC | ₹75.7 L Quoted ₹75.75 | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical | - | - | Rejected-Technical Second Lowest |
Tender Value
₹77.5 L
EMD Value
₹50,000
Closing Date
17 Feb 2020, 5:00 pmClosed
MEMBER SECRETARY
TDB BUILDING PUTHENCHANTAI TRIVANDRUM
TSM Sabarimala General Electrification Providing yard lighting arrangements in and around the temple premises at Pampa
2020_HPC_341569_1
T-18/HPC/SMP/2019-20
Open Tender
Civil Works - Others
210 days
PUTHENCHANTAI
as per NIT
3 documents required · 3 mandatory
₹2,500
online
₹50,000
30 Sept 2020
6 Feb 2020
20 Feb 2020
6 Feb 2020
17 Feb 2020
6 Feb 2020
Amount
Supply, conveyance, installation, testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 100mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 12 Meters
Supply, conveyance, installation, testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 150mm top diameter, 360mm bottom diameter thickness 3mm mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 6 nos fixed in existing RCC foundation and junction box etc, complete 16 Meters
Supply, conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 65/66 protection LED Chip make Cree/Lumilled/Nichea with internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,toughened glass cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
Supply, conveyance, installation, testing and commissioning of 250W LED flood light including 80/0.20 mm sqmm three core ISI Marked FR LS PVC sheathed round copper conductor cable etc. as req; (Crompton or equitant make)
180 KW/225 KVA,SILENT Diesel Generating Set with CPCB approved acoustic enclosure comprising of "Cummins" Model QSB6.7-G13, Radiator Cooled,Diesel engine developing 280 BHP at 1500 RPM ,complete with standard accessories , coupled to "Stamford" Alternator rated at 180KW/225 KVA, AT 415 Volts, mounted on Channel Iron Base Frame complete with 400 Ltrs Fuel Tank capacity w2ith Standard control Panel and Batteries Price :- 16,00,000 fleight charges: 70,000 Overall Profit : 2,40,000
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). a. 3.5 core 120 sq mm
b. 4 core 16 sq mm
c. 4 core 50 sq mm
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. ( For HIGH MAST)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required..
Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
Supply and providing heavy duty 'A' section neoprene gasket in the panel board U' section rubber beeding suitable for 1.60/ 2.00 mm sheet
Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
Supply and providing copper earth bus in the panel board
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. a. 250 Amp, 36 KA
b. 100 Amp, 30 KA 4 Pole
Supplying and fixing following rating, four pole, (three phase and neutral), residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a. 63 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a. 63 amps
b. 40 amps
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray using clamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run). 20 x 3 mm copper strip
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. a. 4 X 16 sq. mm (28mm)
b. 4 X 50 sq. mm (35mm)
c. 3 1/2 X 120 sq. mm (45mm)
d. 250 mm X 200 mm H.T. danger notice plate
Excavation of the cable trenches in hard rock not exceeding 1.5 meter in width, and lift upto 1.5 meter, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 meter.
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
Construction of shallow foundation with 1:2:4: M20 grade concrete for the high mast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with reinforcement for RCC work, Bend Tied and placed in position including form work for reinforcement cement concrete and excavation of soil is including neat banking with all materials and labour. As per the direction of department officers.
Erection and commissioning of the high mast with the help of suitable tools and plants wiring of luminaries with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq.mm, lugs, MCB and all labour.
Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required. 50 mm dia. G.I. pipe (medium class)
D SURESH
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_477576.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid