Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹18.4 L+₹67,748.37 (3.82%)Rejected-AOC NOT AVAILABLE | L2 | Rejected-AOC L2 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
4 Mar 2021, 6:00 pmClosed
AE LSGD PUTHUR
AE LSGD PUTHUR PUTHUR, PUTHUR (P.O)
CMLRRP 2019-20 (Sl. No. 669) - Puthur Grama Panchayath ward 1 KAINOOR CHIRA CANAL BUND ROAD (Ollukkara BP - Ollur LAC)
2021_LSGD_418761_1
15/AELSGD/PTR/20-21
Open Tender
Civil Works - Roads
Item Rate
180 days
PUTHUR, PUTHUR (P.O)
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,975
₹30,000
16 Nov 2021
25 Feb 2021
6 Mar 2021
25 Feb 2021
4 Mar 2021
25 Feb 2021
Amount
DRAIN
2.7.D : Dismantling Stone Masonry as per Technical Specification Clause 202.Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.(D)Dry Rubble Masonry
12.5.1.1 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 mI.P.C.C grade M 15(i)Nominal mix (1:2.5:5)
13.1.1.1 : Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5I.R.C.C grade M 20(i)For nominal mix 1:2:4
12.7 : Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
SIDE PROTECTION WALL
3.5.1 : Excavation in Cutting in Soil by manual means with lead upto 50 mExcavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3
od1079332/2020_2021 : DR with Departmental. Stone - DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course using departmental rubble including packing to compactness to lines and levels, labour charges etc. complete as per direction of Departmental officers at site (Modified 60.7.8)<br>
od877612/2020_2021 : DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. ( Modified Data 60.7.1)- MoRD spec.
12.5.2.1 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204For height upto 5 mII.P.C.C. grade M 20 (i)Nominal mix (1:2:4)
ROAD WORK
3.15.2 : Compacting Original Ground<br> (ii) Compacting original ground supporting subgrade<br> Loosening of the ground upto a level of 300 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per Technical Specification Clause 303.5.2.
od877629/2020_2021 : Filling with Quarry Muck (MoRD)<br>Filling up low lying and water logged areas with local material/ quarry muck, spreading in layers, leveling the top at site and consolidation by ramming, etc complete for improving the CBR value of subgrade
11.4.3.1 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203III.P.C.C. grade M 20 (i)Nominal mix (1:2:4)
NAME BOARD
od877747/2020_2021 : Providing and erecting Name Board of semi Reflective type as per IRC-67 made of 2 mm thick M.S. Sheet duly stove enameled paint white colour in front and grey colour on back with reflective border of 70 mm width and required letters, figures with reflective tape of engineering grade as per MoRD specifications of required shade and colour. Supported and welded on two nos. 47 mm x 47 mm of 12 SWG square tube of 3050 mm height duly strengthened by 25 mm x 5 mm MS flat iron on edges on back firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450 mm x 450 mm x 450mm, 450 mm below ground level as per approved drawing and Technical Specification Clause 1701(10.4.B MoRD)
Mr.M.GOGIN
Bidder Name
Mr.M.GOGIN
AJAYKUMAR K
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_594597.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .