AGE I R AND D MANALI
AGE I R AND D MANALI PIN 175103 PH 01902255014
PROVN OF SEWAGE LINE IN OFFICER MESS AREA AT DGRE RDC MANALI
2022_MES_554505_1
AGE(I)/MNL-56/2022-23
Open Tender
Civil Works
Item Rate
180 days
DGRE MANALI
As per NIT and Tender Documents
5 documents required · 5 mandatory
₹300
AGE I R AND D MANALI
₹9,700
Yes
31 Dec 2022
27 Sept 2022
29 Oct 2022
27 Sept 2022
27 Oct 2022
13 Oct 2022
Amount
M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard and dense soil complete all as specified and directed by Engineer-in-charge.
S&F for 150mm bore size UPVC pipe(SCH-80), (The measurement of pipes shall be net as fixed between the fittings including short lenghts, without any allowance for cutting and waste, and in case of spigot and socketed pipes for the protions entering the sockets of the pipes and fittings. includig all necessary fittings and fixtures. The rates for laying UPVC pipes and fittings include for jointing and jointing materials, complete all as specified and directed by Engineer-in-Charge.
M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers, not exc 25 cm, complete all as specified and directed by Engineer-in-Charge
M&L for Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for 150mm thick cement concrete 1 : 3 : 6 type C2 using 40mm graded stone aggregates as in concrete bed to drain pipe incl packing under and haunching against the sides for 150mm internal dia SGSW pipes after they are laid and tested in complete all as specified complete all as specified and directed by Engineer-In- Charge
M&L for 100mm thick Cement concrete 1:4:8 type D-2 as in foundations, filling and mass concrete complete all as specified complete all as specified and directed by Engineer-In- Charge
M &L for PCC 1:2:4 type B1 as in coping surface channels, benchings etc of lmanholes finished fair and even, complete all as specified complete all as specified and directed by Engineer-In- Charge
Cutting into existing manholes for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section ) in cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate finished smooth and reforming benching as required for 150mm dia pipescomplete all as specified and directed by Engineer-In- Charge
Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:4 but except bricks
M&L for Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-charge.
Demolition of PCC of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-In- Charge
M&L for providing pre cast RCC cover slab made from cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in drain cover slab and man hole covers etc setting in CM (1:4) complete all as specified and directed by Engineer-In- Charge.
M&L for mild steel TMT bars 10 mm dia and over cut to length and bent to shape required and binding with mild steel wire dia not less than 0.9 mm (annealed) complete all as specified complete all as specified and directed by Engineer-In- Charge
M&L for Rendering 15 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces and finished even and smooth (without using extra lime or cement) complete all as specified and directed by Engineer-in-charge.
M&L for 75mm thick cement concrete 1:3:6 type C-2 using 40mm gradded stone aggregate as in plinth protection finished even and fair without using extra cement complete all as specified and directed by Engineer-In- Charge
S&F for 100mm bore size UPVC pipe(SCH-40), (The measurement of pipes shall be net as fixed between the fittings including short lenghts, without any allowance for cutting and waste, and in case of spigot and socketed pipes for the protions entering the sockets of the pipes and fittings. includig all necessary fittings and fixtures. The rates for laying UPVC pipes and fittings include for jointing and jointing materials, complete all as specified and directed by Engineer-in-Charge.
M&L for Cement concrete tiles 30cm x 30cm x 25mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors with grey cement with pigment and cut and polished including 20mm thick screed bed in CM (1:6) complete all as specified and directed by Engineer-in-Charge.
SP Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .