Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC 292 KRISHNA COLONY OLD HAMIDA SAHARANPUR ROAD YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | ₹25.4 L | L1 | Accepted-AOC AOC accepted. |
| 2 | L2₹27.0 L+₹1.6 L (6.42%)Rejected-AOC | ₹27.0 L+₹1.6 L (6.42%) | L2 | Rejected-AOC AOC rejected. |
| 3 | L3₹27.9 L+₹2.5 L (9.97%)Rejected-AOC WZ 1391 31 B NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹27.9 L+₹2.5 L (9.97%) | L3 | Rejected-AOC AOC rejected. |
| 4 | L4₹29.9 L+₹4.6 L (18.1%)Rejected-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | ₹29.9 L+₹4.6 L (18.1%) | L4 | Rejected-AOC AOC rejected. |
| 5 | L5₹32.5 L+₹7.2 L (28.2%)Rejected-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹32.5 L+₹7.2 L (28.2%) | L5 | Rejected-AOC AOC rejected. |
Tender Value
₹40.4 L
EMD Value
₹80,800
Closing Date
26 Sept 2023, 6:00 pmClosed
GE Dehradun
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Repair and maintenance of Street light and Allied works at Garhi cantt under AGE E/M-II of GE Dehradun.
2023_MES_616230_1
8668/A/E8
Open Tender
Civil Works
Item Rate
334 days
GE Dehradun
Class D Cat b (i)
8 documents required · 8 mandatory
₹500
GE Dehradun
₹80,800
Yes
22 Dec 2023
29 Aug 2023
28 Sept 2023
29 Aug 2023
26 Sept 2023
12 Sept 2023
Amount
Material and labour for attending day to day complaint of street light /Flood light /Post top light /Garden light any where at Anarwala,Garhi cantt & MH ,rectifying cable faults,cleaning of street light.Timer panel ,removing the creapers,trimming of tree branches etc by using neccessary tools and equipments complete all as specified and directed.
Supply &Fixing in replacement of LED light fitting driver suitable for 25-45 watts fittings as per sample complete all as specifeid & directed. Make : Havells/Crompton/Philips or as approved
Supply &Fixing in replacement of LED light fitting driver suitable for 60-100 watts fittings as per sample complete all as specifeid & directed Make : Havells/Crompton/Philips or as approved
Supply &Fixing in replacement of surge protection device 10 KV 240 Volts suitable for LED street light fitting complete all as specified and directed. Make : Havells/Crompton/Philips or as approved
Supply & Fixing in repair of power contactors 4 pole 40-80 Amps AC3 in control of timer as per existing one etc complete incl taking existing and necessary connection complete all as specifeid & directed Make:- L&T/BCH/Legrand
Supply & Fixing in repair of power contactors 4 pole 9-25 Amps AC3 in control of timer etc complete as per existing oneincl taking existing and necessary connection complete all as specified and directed. Make:- L&T/BCH/Legrand
Supply &Fixing in repair of coil for contactor 40 Amps to 80 Amps as per existing sample complete incl taking out existing and necessary connections complete all as specified and directed.
Supply &Fixing in repair of coil for contactor 9 Amps to 25 Amps as per existing sample complete incl taking out existing and necessary connections complete all as specified and directed.
Supply and fix MCB ,single pole 240 Volt, C curve 10 KA ISI Marked 5 to 32 Amps all as specified and directed.
Supply and fix MCB, SPN, 240 Volt, C curve 10 KA ISI Marked , 20-25 Amps in existing DBs all as specified and directed.
Supply and fix MCB ,TPN,415 Volt, C curve 10 KA ISI Marked ,63Amps all as specified and directed.
Taking down and dismantling of Street light fittings of any size and model (FTL ,ES,HPSV,MVL,MH,Flood light fitting,garden/gate lts etc) and depositing the same to MES store yard for repair if any required or as directed by Eng in charge complete all as specified and directed.
Fixing only of street light taken down against the item here and above but after repair and replacement of unserviceable spares/accessories for the same including refixing the street light fittings of any size ,type and model of existing pole ,including existing pole, including neccessary electric connection by providing PVC insulated and sheathed aluminium conductor cable of 3 single core of size 2.50 sqmm (nominal cross sectional area) from junction box to fittings incl testing complete all as specified and as directed Note : divers,surge protector shall be paid & separately under relevent items
Supply & Fixing of u/s street light timer single phase street panel comprising MCB 40 Amp SP power contactor 40A luxo switch 1 Lux =1,000,00 auto manual faclity duly complete wiring suitable for 15 KW 3 phase 6 module enclosure with IP 65 protection front door use suitable for 240V 3 phase including GI clamping & fixing to pole with IP-65 a weather proof & out door type IK09 protection and taking down old u/s panel all as directed. Make: Legrand/Simens/Schneider
Supply and fix in repair , Timer digital type 1P Module, 24 hours program ,programmable every 15 min ,back up of 100 hours ,current cap 16 a with 1 change over (1 CO) complete all as specified & directed incl taking out old u/s existing timer
Supply only GI bracket made out of 40 mm GI pipe medium grade bend for fabrication to shape as required length of pipe 1.2 mtr with necessary fixing arrangement by means of MS clamps 02 Nos not less than 50x6 mm MS flat duly painted, nuts, bolts and washer complete all as directed. (Make TATA/JINDAL/Swastik).
Supply only of 3 core 1.5 Sqmm copper conductor cable in existing pole incl making holes for cable entry and exist near to light fitting and junction box complete all as directed.
Supply and fix in replacement flood light ,50 W,Outdoor type with high power LED's as light sources . Energy saving environmental friendly, long life, exclusive innovative epoxy powder coated die-cast aluminium housing with dedicated heat sink and toughened glass with inbuilt control grar woth IP66,CCT :5700K,Efficacy : 100 Im/W,Impact resitace of IK07 and integrated driver with 5 KV inbuilt surge protection complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement flood light ,80 W,Outdoor type with high power LED's as light sources . Energy saving environmental friendly, long life, exclusive innovative epoxy powder coated die-cast aluminium housing with dedicated heat sink and toughened glass with inbuilt control grar woth IP66,CCT :5700K,Efficacy : 100 Im/W,Impact resitace of IK07 and integrated driver with 5 KV inbuilt surge protection complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement flood light ,120 W,Outdoor type with high power LED's as light sources . Energy saving environmental friendly, long life, exclusive innovative epoxy powder coated die-cast aluminium housing with dedicated heat sink and toughened glass with inbuilt control grar woth IP66,CCT :5700K,Efficacy : 100 Im/W,Impact resitace of IK07 and integrated driver with 5 KV inbuilt surge protection complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement flood light ,200W OR higher Outdoor type with high power LED's as light sources . Energy saving environmental friendly, long life, exclusive innovative epoxy powder coated die-cast aluminium housing with dedicated heat sink and toughened glass with inbuilt control grar woth IP66,CCT :5700K,Efficacy : 100 Im/W,Impact resitace of IK07 and integrated driver with 5 KV inbuilt surge protection complete all as specified and directed by Engr-in-Charge.
Supply and fix in relacement Integral LED Street Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65/66 protection road way luminaries with high power LED 60 watt with Efficacy 110 Lm/W,CCT :5700 K with potted 5KV internal and 10 KV external inbuilt surge protection including taking out old u/s street lights complete all as specified and directed by Engr-in-Charge.
Supply and fix in relacement Integral LED Street Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65/66 protection road way luminaries with high power LED 45 watt with Efficacy 110 Lm/W,CCT :5700 K with potted 5KV internal and 10 KV external inbuilt surge protection including taking out old u/s street lights complete all as specified and directed by Engr-in-Charge.
Supply and fix in relacement Integral LED Street Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65/66 protection road way luminaries with high power LED 72 watt with Efficacy 110 Lm/W,CCT :5700 K with potted 5KV internal and 10 KV external inbuilt surge protection including taking out old u/s street lights complete all as specified and directed by Engr-in-Charge.
Supply and fix Post top latern LED type 20 Watt ,230volts AC outdooor type with decorative post top for 360 drgree indirect light IP 65 protection with impact and corrossion resistanat complete with driver and lamp complete with suitable size reducer or fixing arrangement to fix to existing one for park,garden,heritage site & gatesincluding taking down existing old pattern unserviceable light fittings as specified & directed.
Supply and fix LED bollard type fitting 10 watt capacity inverted Pyramid Tripod type with soft 360 degree distribution with IP 65 protection ,complete with necessary PCC foundation including taking down existing old pattern unserviceable light fittings all as specified and directed . NOTE : PCC Shall be paid &measured in the relevent items.
Supply and fix Integated Solar street light All in one comprising of high efficiency LEDs (120lm/w) ,12 W ,efficient monocrystalline Solar panel of 30 Wp ,new age Lithium ferro phosphate battery of cap 12.8 V/12Ah ,silcon encapsulated high efficiency MPPT Chage controller, uniquely designed Aluminium housing for better heat dissipation & strategically placed perforations allowing natural air passive circulation within & into the housing for better heat dissipation & strategically placed perforations allowing natural air passive circulation within & into the housing for improved thermal management of internal components including mounting bracket in built PIR Motion sensor including galvanised steel pole in built as per suitable size & length all as per directed by Eng-in-charge
Supply and fix LED bush light ,9 Watt, 3000K , Efficacy 80 lm/w ,made with single piece pressure die-cast aluminium housing and ip 65 degree of protection suitable for outdoor applicatios like garden,tree uplighting including suitable fixing arrangements all as directed by Engr-in-charge
Material and labour for service cable 6 sq mm twin core Weather proof aluminium multistranded conductor cable PVC sheathed PVC insulated round suspended with No.8 SWG GI wire and reel insulators at distance of 01 mtr duly connected with earthing and clamp etc from Pole to pole complete all as specified and directed.
All as per Item No 29 here-in-before but 10x2 sq mm complete all as specfied and directed.
Supply and fix PVC conduit medium grade 20 MM dia for drawing WP cable incl fixing with suitable size of clamps all as specified & directed.
Supply and fix for DK Thermoplastic cable Junction boxes of size 260x210x116mm,IP 65 with metric knockouts for cable entry , weather proof for outdoor installation & inclu cable glands with four terminalSupply and fix our busbar fixing on eight nos DMC insulators for terminating with one incoming & one outgoing armoured UG cable of size 10 to 35 qmm x 4/3.5 core with suitable size of lugs & provn for fixing of one no MCB,SPN & fixed to the PCC/Steel Poles by means of suitable size of clamps with nuts & bolts & all as specified and directed as in repair.
Supply and fix for DK Thermoplastic cable Junction boxes of size 167x125x82 mm,IP 65 with metric knockouts for cable entry , weather proof for outdoor installation & inclu cable glands with four terminals & two busbar fixing on 04 nos DMC insulators for terminating with one incoming & one outgoing armoured UG cable of size 4 to 10 sqmm x 2 core with suitable size of lug including fixing to the PCC/Steel Poles by means of suitable size of clamps with nuts & bolts & all as specified and directed as in repair.
Supply and fix in replacement Street light TIMER control panel ,110 Amps,3 pole /230 Volt ,Digital time switch ,pole/wall mounting made out of 3.15mm CRCA sheet duly power coated with locking arrangement including internal wiring complete with bypass arrangements complete all as specified and directed.
Material and labour for painting to steel pole any type after scrapping and rubbing down with sand paper prepation of old or new surface of poles including pole fitting such as cross arms of any description ,anti climbing devices,nut,bolts etc with two coat of aluminium paint incuding numbering of pole as per existing complete all as directed and making 5 nos of alternative strips of black,yellow paint of 30 Cm wide complete all as directed.
Dismantling existing steel poles/stuts ,any size carefully for reuse inclding necessary excavation .demolition of concrete etc and removing the old unserviceable poles/rubbish off the premises etc complete all as specified and directed.
Fixing only of street poles of any length and dia retrieved against respective dismantling from ser item no 35 here-in-before including loading ,shifting ,unloading errection in true vertical position complete all as specified and directed. Note : Excavation and PCC for fixing of pole shall be measured and paid separately.
Supply and fixing steel tubular swaged pole type 410 SP-22, 8.5 mtr long conforming to IS - 2713 in vertical position, applying two coats of aluminium paint over a coat of red oxide primer externally above ground level and a coat of anti corrosive below ground level a with cast Iron base plate , drilling of holes for cable entering and including taper plug complete all as specified and directed by Engr-in-Charge.
Cutting existing road/hardstand of any type by using crow bar chisel upto a depthof 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Material and labour for removing the herb, shrubs, creepers etc on the LT/HT Poles(single/two/four) to keep poles/structures always clean and tidy condition. Note:- All the Poles shall be kept clean throughout contract period by repeatedly by removing the grass / shrubs as many times reqd depending on the growth of grass measurement will be measured & paid only once throughout contract period only once.
Supply & Laying XLPE insulated armoured heavy duty electric cable , with multi stranded aluminium conductor served with an inner sheathing of PVC type armoured with galvanized steel wire or tape and PVC sheathed 1100 volt grade,nominal cross sectional area 16 Sqmm 4.0 core incl lugs and heat shrinkable PVC Sleeves on exposed surfaces & teflon tape duly insulated complete laid in trenches, ducts, drawn through pipe across the road/path/alongpoles/wall/floors/equipment etc including jointing and testing complete all as specified and directed by the Engr-in-charge.
Supply & Laying XLPE insulated armoured heavy duty electric cable , with multi stranded aluminium conductor served with an inner sheathing of PVC type armoured with galvanized steel wire or tape and PVC sheathed 1100 volt grade,nominal cross sectional area 10 Sqmm 2 core inclu lugs and heat shrinkable PVC Sleeves on exposed surfaces & teflon tape duly insulated complete laid in trenches, ducts, drawn through pipe across the road/path/alongpoles/wall/floors/equipment etc including jointing and testing complete all as specified and directed by the Engr-in-charge.
Supply & Laying XLPE insulated armoured heavy duty electric cable , with multi stranded aluminium conductor served with an inner sheathing of PVC type armoured with galvanized steel wire or tape and PVC sheathed 1100 volt grade,nominal cross sectional area 10 Sqmm 4.0 core inclu lugs and heat shrinkable PVC Sleeves on exposed surfaces & teflon tape duly insulated complete laid in trenches, ducts, drawn through pipe across the road/path/alongpoles/wall/floors/equipment etc including jointing and testing complete all as specified and directed by the Engr-in-charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for laying of electric cableand getting out in soft/loose soil, complete all as specified and directed by Engr -in-charge
Returning, filling in excavated soil , including leveling,watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr -in-charge
Removing excavated material(soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above & starting point complete all as specified and directed by Engr-in-charge.
Material and labour for sand cushioning in trenches for protection of UG cable with river based sand laid dry in trenches before and after laying of cable, incl well ramming complete all as specified and directed.
Material and labour for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified & directed.
Supply & Laying in replacement of GI Steel tubing light grade 40 mm dia including all fitting laying in trenches across road or grouting /fixing on wall for protection of cable complete all as specified and directed by Engr-in-charge.
Supply & Laying in replacement of GI Steel tubing light grade 25 mm dia including all fitting laying in trenches across road or grouting /fixing on wall for protection of cable complete all as specified and directed by Engr-in-charge.
Material and labour PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation for Post/Pole/ FPB /Transformer plinth plateform etc including finished even and fair to exposed surfaces without using extra cement complete all as specified and as directed by Engr-in-Charge.
Material and labour PCC 1:2:4 type B-1 (with using 20 mm graded stone aggregate) as in coping of pole/FPB/TFR plinth plateform including necessary form work as required complete as directed by Engr-in-Charge.
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized wire 4 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 15 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR part 1 including testing on completion all as specified and directed. incl demolition to existing one complete. Note: (i) Earthing has to done by spl persons and if the desired earth resistance is not found within permissible limit shall be redone by contractor at no extra cost. (ii) Cost of GI wire 4 sqmm and 15 mm dia pipe medium grade upto 7.5 mtr is included in the rate quoted for this item
Supra Electrical
G M CONSTRUCTION COMPANY
M/s SCHOLASTIC ENTERPRISES
Ansh Enterprises
BRICKS ON CLOUD INFRA
Friends fire Engineers
Balraj and Co
M/s Ram Chander Gupta
JS CONSTRUCTION COMPANY
RAMSONS DEVELOPERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .