Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC 368 SECTOR 28 R INITIATIVE ENTERPRSIES GST NO 06ALTPK2595G1ZN SECTOR 28 FARIDABAD HARYANA 121003 | FARIDABAD | HARYANA | 121003 | L1 | Accepted-AOC AWARD | |
| 2 | L2₹10.3 L+₹83,445 (8.84%)Rejected-AOC VILLAGE KAIRU DISTRICT BHIWANI | BHIWANI | HARYANA | 127021 | L2 | Rejected-AOC REFUND | |
| 3 | L3₹11.1 L+₹1.7 L (17.9%)Rejected-AOC 781 SECTOR 9 126102 | JIND | HARYANA | 126102 | L3 | Rejected-AOC REFUND |
Tender Value
₹6.8 L
EMD Value
₹13,640
Closing Date
28 Jan 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER
EXECUTIVE ENGINEER, PHED NARAINGARH
Supplying of pH meter, Conductivity meter /TDS METER, Turbidity meter (Benchtop)/ (Portable), Double Distillation plant, Hot Air Oven, Hygrometer, Thermometer simple and with probe, Analytical Balance, Calibrated Weights, Desiccator etc.
2022_HRY_205057_1
SE Memo No. 8662 dated 22-12-2021 PHED NARAINGARH
Open Limited
Civil Works
Works
30 days
NARAINGARH
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
₹13,640
Yes
9 May 2022
21 Jan 2022
28 Jan 2022
21 Jan 2022
28 Jan 2022
21 Jan 2022
7 days
Amount
Works Details
pH meter (with 5 years AMC) (With pH Electrode) pH Range -2.00 to 16.00 pH Resolution/Accuracy 0.01 pH/± 0.01 pH ORP Range ± 2000 mV Resolution/Accuracy 1.1 (± 199.9 mV) / 1 mV (beyond) 1.2 ± 0.2(± 199.9 mV) /± 2 mV (beyond) Temp.range 0.0 to 100.00 C (32.0 to 212.00 F) Resolution/Accuracy 0.1 0 C(0.1 0 F)/±0.3 ºC / ±0.5 ºF (0 to 70 ºC) ATC Yes (0 to 100 0 C) Buffer Options USA: pH 1.68, 4.01, 7.00, 10.01,12.45 NIST pH 1.68, 4.01, 6.86, 9.18 ,12.45 No.of pH Calibration Points 5points Built-in Electrode Arm Yes Memory 100data sets Electrode Included ECFC7252101B,single junction pH electrode. Temp.Probe Included LCD DISPLAY CUSTOM dual-display LCD(5.6X7.5cm) Power Requirements Included, 100 /240VAC SMPS Power Adapter with US/UK/EUR/Japan plug ,9V,6W, CENTRE (Make :- EUTECH, WTW, OAKTON)
Conductivity meter /TDS METER (with AMC for 5years) (With Electrode) Conductivity Range 0.01 to 200.0 mS/cm Resolution/Accuracy 0.01 / 0.1 μS ; 1 / 0.01mS / 0.1 mS ±1 % full scale Resistivity Range 2.000 Ω to 20.0 MΩ Resolution/Accuracy 0.01 / 0.1 Ω ; 0.001 / 0.1 kΩ ; 0.01 MΩ ±1 % full scale Salinity Range 0.0 to 80.0 ppt Resolution/Accuracy 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt ±1 % full scale TDS Range 0.050 ppm to 500 ppt (@ TDS factor 1.00) Resolution/Accuracy 0.01 / 0.1 ppm ; 0.001 / 0.01 / 0.1 ppt Resolution/Accuracy 0.10 C (0.1 0 F); ±0.3 0 C(± 0.5 0 F) Temp. Coefficient Linear & pure ; 0.000 to 10.000 % Normalization Temperature 15.0 to 30.0 0 C (59.0 to 86.0 0 F) Built-in Electrode Arm Yes Compensation ATC / MTC Memory 100 data sets electrode Included, 2 cell epoxy body Conductivity electrode, K=1.0, Power Requirements Included, 100 /240VAC SMPS Power Adapter , 9V, 6W (Make :- Eutech, WTW, Hach, Lovibond)
Turbidity meter (Benchtop)/ (Portable) (with amc for 5 years) Accuracy: ±2% of reading plus 0.01 FNU/NTU from 0 - 1000 FNU/NTU Certifications: CE, KC, RCM Communication: USB Compliance: ISO Data logging: 2000 total logs, includes reading log, verification log and calibration log Display: 17.8 mm colour touch screen Interface: 2 USB-A ports for USB flash drive, external printer, keyboard and barcode scanner Light source: Light-emitting diode (IR LED) at 860 ± 30 nm Measurement method: Nephelometric Operating temperature range: 0 - 40 °C Power requirements (Voltage): 100 - 240 VAC Range: 0 - 1000 NTU NTU/FNU: 0 - 1000 Reading modes: Single, continuous, Rapidly Settling Turbidity, signal averaging on or off Regulatory: Meets ISO 7027, DIN EN 27027, DIN 38404 and NFT 9033 Repeatability: ±1% of reading or 0.01 FNU/NTU, whichever is greater (under reference conditions) Response time: Signal averaging off: 6.8 seconds / Signal averaging on: 14 seconds (when 10 measurements are used to calculate the average) Sample cell compatibility: Round cells 95 x 25 mm (3.74 x 1 in.) borosilicate glass with rubber-lined screw caps Note: Smaller sample cells (less than 25 mm) can be used when a cell adapter is used. Sample requirements: 25 mm sample cell: 20 mL minimum 0 to 70 °C (32 to 158 °F) Source Lamp: LED Stabilisation time: Immediately Storage conditions: -20 to 60 °C Units: FNU and NTU (Make :- Eutech, WTW, Hach, Lovibond)
Double Distillation plant All Quartz Double Distillation Unit Demountable Boiler Panel Series, Vertical Model with Distillation Apparatus Power Supply Capacity 2.5 Ltr/hr (Make :- Borosil, Glassco)
Hygrometer (with Calibration certificate from NABL accredited Laboratory) Temp.Range -500C ~ +700C Temp. Measuring Accuracy: ± 10C Temp. Resolution: 0.10C Humidity Meas.Range: 10% RH ~ 99% Humidity Accuracy: ±5% RH Humidity Resolution: 1% (Make :- HTC)
Thermometer simple and with probe (with Calibration certificate from NABL accredited Laboratory) Digital LCD Thermometer with sensor probe (Make :- LT(Type k), Thomassci, Hanna)
Analytical Balance (with 5 years AMC) (with Calibration certificate from NABL accredited Laboratory) Analytical Balance Capacity 220 gm Accuracy 0.01 mg with internal calibration Pan Size 90 mm (Make :- Radwag, Mettler Toledo, Sartorius, Shimazhu)
Calibrated Weights (with Calibration certificate from NABL accredited Laboratory) Standard Weight Box Class F1 capacity 1 mg to 200 gm with NABL Accredited Lab Calibration Certificate (Set of 23 wire weights) (Make :- Radwag, Mettler Toledo, Sartorius, denver, wensar)
Dessicator 250 mm along with 1 kg silia gel (Qualigen) (Make :- Borosil, Glassco, Thermo)
Laboratory Refrigerator 400 Ltr. with front door of transparent glass (Make Voltas/ Westron)
Water Bath (12 Nos. Holes of 3" with multipal lids of different size to cover the holes)
Burette (50 ml.) (A Grade with calibration certificate from NABL accredited Laboratory
Volumetric pipette (20 ml. with calibration certificate from NABL accredited Laboratory (Borosil Glass)
Volumetric pipette (10 ml. with calibration certificate from NABL accredited Laboratory (Borosil Glass)
Graduated pipette (10 ml. calibration certificate from NABL accredited Laboratory (Borosil Glass)
Graduated pipette (5 ml. calibration certificate from NABL accredited Laboratory (Borosil Glass)
Graduated pipette (2 ml. calibration certificate from NABL accredited Laboratory (Borosil Glass)
Sodium Chloride 80 gm CRM of Merck Make
pH Buffer Solution 4.0 CRM NIST Traceable with certificate of Merck Make
pH Buffer Solution 7.0 CRM NIST Traceable of Merck Make
pH Buffer Solution 10.00 CRM NIST Traceable of Merck Make
EDTA LR 100 gm. Merck Make
Ammonium Buffer Soln. LR 500 ml. Merck Make
Solorome Black LR 25 gm. Merck Make
Muroxide LR 25 gm. Merck Make
Sodium Hydroxide LR 500 gm. Merck Make
Methyl Orage Indicator 125 ml. Merck Make
Conc. Sulphuric Acid LR 500 ml. Merck Make
Barium Chloride LR 500 g. Merck Make
Volumetric Flask (1000 ml. with calibration certificate from NABL accredited Laboratory (Borosil Glass)
Volumetric Flask (500 ml. with calibration certificate from NABL accredited Laboratory (Borosil Glass)
Volumetric Flask (250 ml. with calibration certificate from NABL accredited Laboratory (Borosil Glass)
Volumetric Flask (100 ml. with calibration certificate from NABL accredited Laboratory (Borosil Glass)
Volumetric Flask (50 ml. with calibration certificate from NABL accredited Laboratory (Borosil Glass)
Measuring Cylinder 100 ml with calibration certificate from NABL accredited Laboratory (Borosil Glass)
Measuring Cylinder 50 ml with calibration certificate from NABL accredited Laboratory (Borosil Glass)
Measuring Cylinder 20 ml with calibration certificate from NABL accredited Laboratory (Borosil Glass)
Measuring Cylinder 10 ml with calibration certificate from NABL accredited Laboratory (Borosil Glass)
Conical Flask 500 ml B Grade Borosil Glass
Conical Flask 250 ml B Grade Borosil Glass
Conical Flask 100 ml A Grade Borosil Glass
Breaker 500 ml B Grade Borosil Glass
Breaker 250 ml B Grade Borosil Glass
Breaker 100 ml B Grade Borosil Glass
Breaker 50 ml B Grade Borosil Glass
Cup with round bottom of 150 ml capacity A Grade Borosil Glass (Round Bottom)
Poly Plastic bottles of 1 Ltr.
Poly Plastic bottles of 500 ml
Poly Plastic bottles of 250 ml
Calcium Corbonate 50 gm CRM of Merck make with certificate
Sodium Corbonate 80 gm CRM of Merck make with certificate
Silver Nitrate LR 25 gm Merck make
Potassium Chromate LR 500 gm Merck make
Whatman Filter paper 100 Nos.
Reference Stationary Material : APHA Standard method book with 23rd edition and relevant BIS reference code (Original copy)
Calcium Caronate 500 gm Merck make LR
Soldium Caronate 500 gm Merck make LR
Soldium Chloride 500 gm Merck make LR
Burrette Stand Ply Plastic Heavy
Fire Extinguisher (Small Size)
Eye Showers (Medium Size) Standard make
Gloves with good quality
First Aid Box
Nesslers jar 100 ml with 50 ml mark (borosil) B grade
Conc. Hydrochloric acid (500 ml)
Silica Gel (500 gm)
Funnel 3" (borosil)
Funnel 4" (borosil)
Calcium chloride LR 500 gm
Colours calibration standard (CLR-100-500 ml.) CRM of Sigma-ALORICH Co.
Turbidity calibration standard 500 NTU CRM 500 ml (Formazin)
Ammonium ferrous sulphate LR 500 gm Merck Make
Odour testing bottle 250 ml Borosil
Naveen kumar contractor
SANDEEP KUMAR CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .