| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAccepted-AOC 88 C LAKE VIEW ROAD LAKE VIEW ROAD KOLKATA WEST BENGAL 700029 | KOLKATA | WEST BENGAL | 700029 | ₹2.6 Cr | L1 | Accepted-AOC Accepted-Financially |
| 2 | L2₹3.9 Cr+₹1.3 Cr (52.1%)Rejected-AOC 2 KALKAJI INDUSTRIAL AREA KALKAJI KALKAJI SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | ₹3.9 Cr+₹1.3 Cr (52.1%) | L2 | Rejected-AOC Not Accepted Financially |
| Sl No | Description | Qty | Unit | LLOYD INSULATIONS (INDIA) LIMITED L2 | INDOBELL INSULATIONS LIMITED L1 |
|---|---|---|---|---|---|
| .10INSULATION WORKS | |||||
| 1.00Storage Tanks:- HOT INSULATION Providing thermal insulation including supply of all insulating and anciliary material, weather protective covering, consumables and other necessary materials, testing of the material as required including transportation of the materials to work sites, applying insulation on surfaces as specified, including all preparatory works thereon, all binding, tying, lacing, stitching and/or otherwise securing, providing vapour barrier, finishing with plain/corrugated sheet cladding or as specified providing bolts, rivets, self tapping screws wherever specified, providing inspection windows etc., providing necessary scaffolding, all tools and tackles, equipment, apparatus etc., labour and supervision and completing the work in all respect at all heights as per drawings, specifications and instructions of Engineer-in-Charge. (Applicable Specification EIL 6-44-0002). (The mentioned thickness in Insulation Line List is based on standards, Sub contractor to validate the thickness standard calculations and design the same as per requirement. The validations & calculations should be submitted and approval needs to be obtained by M/s B and R/ HPCL.) | |||||
| 1.10 | Tank No: -01,02,03 (Dia-10M x HT-15M)-03 Nos Tanks. For Shell of vertical storgae tank.
Surface Material : CS ; Operating Temp. 170 Deg to 300 Deg.
Insulation Material : Rockwool : Insulation Thickness : 75MM
Aluminium cladding 0.71 mm (22 SWG) corrugated sheet & The profile of corrugated sheet shall be 32mm 5mm.
It includes shell manway, nozzles, agitator, wind girder, curb angle and other attachement for shell. | 1,500 | Sq.Mtr | 3,445 ₹51,67,500 | 2,200 ₹33,00,000 Lowest |
| 1.20 | Tank No: -01,02,03 (Dia-10M x HT-15M) For tank Roofs.
Surface Material : CS ; Operating Temp. 170 Deg to 300 Deg.
Insulation Material : Rockwool; Insulation Thickness : 75MM
Aluminium cladding 1.22 mm (18 SWG) Flat sheet
It includes Roof manway, nozzles, other attachement for roof. | 270 | Sq.Mtr | 3,841 ₹10,37,070 | 2,500 ₹6,75,000 Lowest |
| 2.00For Electrical Heat Tracing Piping : Surface Material : CS ; Operating Temp. 170 Deg to 300 Deg. Insulation for IE consists of inner layer of Rockwool and outer layer of PUF / PIC. The thicknesses have been specified as THK(I) and THK(O) for inner and outer layers respectively. suitable aluminium moisture barrier to be provided inbetween rockwool and PUF. Providing thermal insulation including supply of all insulating and anciliary material, Vapour barrier, weather protective covering, consumables and other necessary materials, testing of the material as required including transportation of the materials to work sites, applying insulation on surfaces as specified, including all preparatory works thereon, all binding, tying, lacing, stitching and/or otherwise securing, providing vapour barrier, finishing with plain sheet cladding or as specified providing bolts, rivets, self tapping screws wherever specified, providing inspection windows etc., and also providing necessary scaffolding to electrical heat tracing works , all tools and tackles, equipment, apparatus etc., labour and supervision and completing the work in all respect at all heights as per drawings, specifications and instructions of Engineer-in-Charge. (Applicable Specification EIL 6-44-0002). (The mentioned thickness in Insulation Line List is based on standards, Sub contractor to validate the thickness standard calculations and design the same as per requirement. The validations & calculations should be submitted and approval needs to be obtained by M/s B and R/ HPCL.) | |||||
| 2.01 | Pipes NB 0.75 Inches; Thick(I) 75mm and Thick(O) 25mm | 30 | Mtr | 3,149 ₹94,470 | 1,500 ₹45,000 Lowest |
| 2.02 | Pipes NB 2 Inches; Thick(I) 75mm and Thick(O) 25mm | 16 | Mtr | 3,690 ₹59,040 | 1,700 ₹27,200 Lowest |
| 2.03 | Pipes NB 3 Inches; Thick(I) 75mm and Thick(O) 25mm | 180 | Mtr | 4,132 ₹7,43,760 | 1,900 ₹3,42,000 Lowest |
| 2.04 | Pipes NB 4 Inches; Thick(I) 75mm and Thick(O) 25mm | 1,300 | Mtr | 4,525 ₹58,82,500 | 2,100 ₹27,30,000 Lowest |
| 2.05 | Pipes NB 6 Inches; Thick(I) 75mm and Thick(O) 25mm | 1,250 | Mtr | 5,385 ₹67,31,250 | 2,300 ₹28,75,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹9 L
Closing Date
16 Sept 2025, 4:00 pmClosed
General Manager (Commercial)
Bridge and Roof Co. (India) Ltd Kankaria Centre (4TH/5th Floor) 2/1 Russel Street Kolkata 700 071
ENGAGEMENT OF AGENCY FOR CARRYING OUT INSULATIONS WORKS ON PIPES, EQUIPMENTS AND TANKS ALONG WITH SUPPLY OF MATERIAL FOR OUR EPCC CONTRACT-BITUMEN PLANT OF M/S HPCL, VISAKH REFINERY, VISAKHAPATNAM
2025_BandR_873857_1
BandR/HO/71160/Insulation Work/NIT/SC/01
Open Tender
Miscellaneous Works
Works
150 days
HPCL, VISAKH REFINERY, VISAKHAPATNAM
Please refer to Tender Document
9 documents required · 9 mandatory
₹10,620
Bridge and Roof Co.India Ltd
₹9 L
12 Aug 2026
19 Aug 2025
18 Sept 2025
19 Aug 2025
16 Sept 2025
20 Aug 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.1 | INSULATION WORKS | - | - | - | - |
| 1Storage Tanks:- HOT INSULATION Providing thermal insulation including supply of all insulating and anciliary material, weather protective covering, consumables and other necessary materials, testing of the material as required including transportation of the materials to work sites, applying insulation on surfaces as specified, including all preparatory works thereon, all binding, tying, lacing, stitching and/or otherwise securing, providing vapour barrier, finishing with plain/corrugated sheet cladding or as specified providing bolts, rivets, self tapping screws wherever specified, providing inspection windows etc., providing necessary scaffolding, all tools and tackles, equipment, apparatus etc., labour and supervision and completing the work in all respect at all heights as per drawings, specifications and instructions of Engineer-in-Charge. (Applicable Specification EIL 6-44-0002). (The mentioned thickness in Insulation Line List is based on standards, Sub contractor to validate the thickness standard calculations and design the same as per requirement. The validations & calculations should be submitted and approval needs to be obtained by M/s B and R/ HPCL.) | |||||
| 1.1 | Tank No: -01,02,03 (Dia-10M x HT-15M)-03 Nos Tanks. For Shell of vertical storgae tank.
Surface Material : CS ; Operating Temp. 170 Deg to 300 Deg.
Insulation Material : Rockwool : Insulation Thickness : 75MM
Aluminium cladding 0.71 mm (22 SWG) corrugated sheet & The profile of corrugated sheet shall be 32mm 5mm.
It includes shell manway, nozzles, agitator, wind girder, curb angle and other attachement for shell. | 1,500 | Sq.Mtr | - | - |
| 1.2 | Tank No: -01,02,03 (Dia-10M x HT-15M) For tank Roofs.
Surface Material : CS ; Operating Temp. 170 Deg to 300 Deg.
Insulation Material : Rockwool; Insulation Thickness : 75MM
Aluminium cladding 1.22 mm (18 SWG) Flat sheet
It includes Roof manway, nozzles, other attachement for roof. | 270 | Sq.Mtr | - | - |
| 2For Electrical Heat Tracing Piping : Surface Material : CS ; Operating Temp. 170 Deg to 300 Deg. Insulation for IE consists of inner layer of Rockwool and outer layer of PUF / PIC. The thicknesses have been specified as THK(I) and THK(O) for inner and outer layers respectively. suitable aluminium moisture barrier to be provided inbetween rockwool and PUF. Providing thermal insulation including supply of all insulating and anciliary material, Vapour barrier, weather protective covering, consumables and other necessary materials, testing of the material as required including transportation of the materials to work sites, applying insulation on surfaces as specified, including all preparatory works thereon, all binding, tying, lacing, stitching and/or otherwise securing, providing vapour barrier, finishing with plain sheet cladding or as specified providing bolts, rivets, self tapping screws wherever specified, providing inspection windows etc., and also providing necessary scaffolding to electrical heat tracing works , all tools and tackles, equipment, apparatus etc., labour and supervision and completing the work in all respect at all heights as per drawings, specifications and instructions of Engineer-in-Charge. (Applicable Specification EIL 6-44-0002). (The mentioned thickness in Insulation Line List is based on standards, Sub contractor to validate the thickness standard calculations and design the same as per requirement. The validations & calculations should be submitted and approval needs to be obtained by M/s B and R/ HPCL.) | |||||
| 2.01 | Pipes NB 0.75 Inches; Thick(I) 75mm and Thick(O) 25mm | 30 | Mtr | - | - |
| 2.02 | Pipes NB 2 Inches; Thick(I) 75mm and Thick(O) 25mm | 16 | Mtr | - | - |
| 2.03 | Pipes NB 3 Inches; Thick(I) 75mm and Thick(O) 25mm | 180 | Mtr | - | - |
| 2.04 | Pipes NB 4 Inches; Thick(I) 75mm and Thick(O) 25mm | 1,300 | Mtr | - | - |
| 2.05 | Pipes NB 6 Inches; Thick(I) 75mm and Thick(O) 25mm | 1,250 | Mtr | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.70 MB
BOQ_918591.xls
BOQ • 0.37 MB
eNIT_INSULATION_WORK_HPCL_VISAKH.pdf
Tender Documents • 1.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .