Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹13.0 LAdmitted-Finance | -32.00% | ₹13.0 L | L1 | Admitted-Finance |
| 2 | L2₹13.2 LAdmitted-Finance | -31.00% | ₹13.2 L | L2 | Admitted-Finance |
| 3 | L3₹13.8 LAdmitted-Finance KARUKAPPILLY THATTATHUKUDIYIL BUILDING KOLENCHERY 682311 | KOLENCHERY | ERNAKULAM | KERALA | 682311 | -27.90% | ₹13.8 L | L3 | Admitted-Finance |
| 4 | L4₹14.2 LAdmitted-Finance | -25.78% | ₹14.2 L | L4 | Admitted-Finance |
| 5 | L5₹15.0 LAdmitted-Finance | -21.60% | ₹15.0 L | L5 | Admitted-Finance |
Tender Value
₹19.1 L
EMD Value
₹38,300
Closing Date
5 Mar 2026, 3:00 pmClosed
AGM EM
FCI RO Trivandrum
ARMO Works at FSD Alappuzha Replacing existing old cables with the new cables to MG 1 2 and office buildings and conversion of conventional fittings to energy efficient high lumen LED fittings along with rewiring to Ancillary buildings and DO
2026_FCI_899783_1
ENGG/EM/PTN/17/2025-26 dated 21.02.2026
Open Tender
Electrical Works
60 days
FSD Alappuzha
As per the tender document
11 documents required · 11 mandatory
₹0
₹38,300
16 Mar 2026
23 Feb 2026
6 Mar 2026
23 Feb 2026
5 Mar 2026
23 Feb 2026
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 X 2.5 sq. mm (DSR 2025 - Item no.1.17.12)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire (DSR 2025 - Item no.1.14.8)
2 X 4 sq. mm + 1 X 4 sq. mm earth wire (DSR 2025 - Item no.1.14.3)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C (DSR 2025 -Item no.1.10.3)
Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door(DSR 2025 Item no.2.4.1)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door(DSR 2025 Item no.2.3.1)
12 way, Double door(DSR 2025 Item no.2.3.3)
Supplying and fixing following rating, triple pole, 415 volts, "C" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB omplete with connections, testing and commissioning etc. as required. 63A
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB omplete with connections, testing and commissioning etc. as required. Single pole (DSR 2025 Item no.2.10.1)
Single pole and neutral(DSR 2025 Item no.2.10.2)
Triple pole and neutral (DSR 2025 Item no.2.10.5)
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. (DSR 2025 Item no.2.11)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch(DSR 2025 -Item no.1.24.1)
3 pin 5/6 A socket outlet(DSR 2025 -Item no.1.24.4)
15/16 A switch (DSR 2025 -Item no.1.24.3)
6 pin 15/16 A socket outlet(DSR 2025 -Item no.1.24.5)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 12 Module (200mmX150mm)(DSR 2022 -Item no.1.27.6)
3 Module (100mmX75mm)(DSR 2022 -Item no.1.27.2)
Supply of PVC insulated and PVC sheathed XPLE power cable of 1.1 KV grade armoured UG aluminium conductor cable conforming to IS 7098 part 1 with up-to-date amendment of the following size as required. 4 x 25 sq.mm
4 x 16 sq.mm
4 x 10 sq.mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 25 sq. mm (28mm) (DSR 2025 - Item no. 11.1.34)
4 X 16 sq. mm (28mm) (DSR 2025 - Item no. 11.1.33)
4 X 10 sq. mm (25mm) (DSR 2025 - Item no. 11.1.32)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. upto 35 Sq.mm(Clamped with 1 mm thick saddle)(DSR 2025 item no.10.7.1)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. upto 35 Sq.mm(DSR 2025 item no.10.3.1)
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 100 mm dia(DSR 2025 item no.15.13.3)
Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.(DSR 2025 item no.13.37)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm(DSR 2025 item no.10.5.1)
Supplying and fixing hot press molded SMC Box of size 300 x 200 x 105 mm with suitable clamps to the wall/pole/truss/GI Pipe with connector bar etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (DSR 2025 -Item no.2.18)
Supplying, installation, Testing and commissioning of 40 watt LED LED Well Glass fitting of Environmental friendly, energy saving long life corrosion resistant, vertical/horizontal surface mounting pressure die-cast aluminium well glass luminaires with high power LED as light source and fixing on truss /wall/ pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required
Supplying, installation, Testing and commissioning of 70 watt LED LED Well Glass fitting of Environmental friendly, energy saving long life corrosion resistant, vertical/horizontal surface mounting pressure die-cast aluminium well glass luminaires with high power LED as light source and fixing on truss /wall/ pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required
Supplying, installation, testing and commissioning of Industrial Box type Luminaire batten suitable for single T8 LED Tube on wall/truss for fixing LED tube and using department supplied LED tubes including connection, testing as required.
Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI EMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 72Watt (DSR 2025 -Item no.8.12.13)
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) (DSR 2022 Item no.9.2.3)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. (DSR 2025 Item no.5.4)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. (DSR 2025 -Item no.5.15)
Providing and fixing of Concrete base Mounted Feeder Pillar of size 135 x 120 x 30 cm with 2 mm CRCA Sheet with doors, Bus Bar Size 40 x 4 mm Alumunium, Earth Bar 25 x 4 mm Copper, Door Earthing 2.5 mm Flexible Copper, Painting Powder Coating with provision for one incoming 125 A 4 pole 36 kA MCCB extended rotary handle, ELR with CBCT, three outgoing 63 A 4 pole 36 kA MCCB and one outgoing 63A 4 pole isloator extended rotary handle inclusive toggle switch, indicator lights, protection MCBs, multi function meter etc., complete as required.
Credit value of following dimantled obselete/unserviceable materials. Dismantled scrap wire of Al.conductor cable.
Dismantled Panel Boards, MS conduits, DBs etc., at the site of the work as required
Dismantled Street lights/Flood lights
Dismantled tubelight fittings
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.90 MB
BOQ_945774.xls
BOQ • 0.31 MB
AnnexureB.pdf
Additional Documents • 0.47 MB
MTF.pdf
Tender Documents • 2.14 MB
Download all tender documents and submit your bid