Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC | ₹1.7 Cr | L1 | Accepted-AOC L1 Bidder Agreement executed |
| 2 | Rejected-Technical | - | - | Rejected-Technical L3 Bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical L2 Bidder |
Tender Value
₹1.8 Cr
EMD Value
₹50,000
Closing Date
12 Dec 2024, 3:00 pmClosed
Superintending Engineer
Kerala Water Authority, P.H Circle, Kochi-11
AMRUT AMRUT SAAP 2017 18 Supplying Laying Testing and commissioning of 700mm DI clear water main from Kaladarsana junction to new Kaloor sump Pumpsets and Electrical Works General Civil Work
2024_KWA_711807_1
E-Tender No 41/2024-25/SE/PHC/CHN
Open Tender
Civil Works - Water Works
Item Rate
60 days
Kaloor
Please refer Tender documents.
7 documents required · 7 mandatory
₹6,508
₹50,000
6 Feb 2025
4 Dec 2024
13 Dec 2024
4 Dec 2024
12 Dec 2024
4 Dec 2024
Amount
1Supply, Erection, Testing and Commissioning of 500 KVA 11KV/433V Transformer
OD162916/2024-2025:Supply and erection, testing and commissioning of approved make 11kV, 630A, 21kA, motor operated, compact, outdoor, both side, extensible, non-draw out type, CCV+FRTU (2 Nos. load break switch (OD) incomer and 1 no. fixed type motor operated vacuum circute breaker (VL) outgoing SAFEPLUS compact gas insulated ring main unit with FRTU , all live parts enclosed in an robotically welded stainless steel tank of IP67 class of protection. With battery, battery charger, 2 Nos FPI and with auxiliary PT
OD162950/2024-2025:HT Power Cables - Supply & laying 11KV stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3 kA for 1 sec.), cores laid up, inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable of the following sizes in the existing cable trench conforming to IS: 7098 part II 1985 with latest amendments. 3C x 300 Sqm
OD162936/2024-2025:HT Cable Terminations - Supplying and making indoor cable end termination with heat shrinkable jointing kit, including lugs and other jointing materials, for following sizes, XLPE aluminium conductor cable of 11 KV grade as required. 3C x 300 Sqmm
OD162918/2024-2025:Supply, erection , testing , commissioning of Static type ,DLMS complaint,-/5A, 110V ,class 0.2S, 3 Phase 4 wire HT TOD meter as per KSEB specification. The rate should include cost of fee and other incidental expenses for testing TOD meter
OD162933/2024-2025:supply ,installation, testing ( from authorized authority) &commissioning of protection class CT in the neutral for 500KVA transformer in a suitable enclosure for connecting to low set E/F relay including all incidental expenses CAU statutory payments will be reimbursed on production of original receipts.
OD162930/2024-2025:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5Cx400 sq mm AYFY (Transformer to MSB )- 3 Runs needed
OD162932/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 core 400Sq.mm. 1100V AYFY Cable
OD162923/2024-2025:Supply and providing MS ladder type cable tray and supports made out of suitable size MS angles/ flats etc. including painting with 2 coats of enamel paint over 2 coats of red oxide primer.
OD162927/2024-2025:Supply and providing plate earthing as per IS 3043 by using 1200x1200x12.5mm thick cast iron plate with 2.5mts. Long 40mm dia 'B' class GI watering pipe extended upto middle of CI plate and clamped to the plate by using 3 Nos GI clamps made out of 25x6mm GI strip providing funnel with weld wire mesh. Providing 1 No earth bus made out of 25x6mm copper strip of 30cm long clamped to the water pipe at top and interconnection of earth bus with CI plate by using 2 Nos 25x6mm copper strip of suitable length filling charcoal and salt at alternate intervals of 15cm all around CT plat. Providing masonry earth pit chambers of suitable size and covering with RCC/CI chamber cover etc complete
OD162919/2024-2025:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required as per IS specifications. Rate as per DSR(E&M) 2018 item 5.2
13.71:Lettering with black Japan pint of approved brand and manufacture
OD162924/2024-2025:Supplying and fixing cable route marker with 10cmx10cmx5mm thick G.I.plate with inscription there on,bolted /welded to 35mmx35mmx6mm angle iron,60cm long and fixing the same in ground as required
OD162920/2024-2025:Supply and providing following safety items. 6 mm thick rubber mat 0.90 m wide 1.80 m long ISI marked- 3 nos, DCP type fire extinguisher 5 kg (ISI marked) - 2 nos, CO 2 type fire extinguisher 5 kg (ISI marked)- 2 nos, fire bucket with floor mounting self stand - 2 nos, shock treatment chart duly framed with glass cover - 2 nos, 11 KV gloves - 2 pair, danger baord - 6 nos, first aid box with medicine - 1 box,earth rod of 3. m long 1no etc
OD162928/2024-2025::Charges for preparation of electrical scheme and getting energisation approval (including clearing defects if any) from electrical inspectorate.Statutory fee excluded from the cost (statutory fee shall be done by KWA)
OD162909/2024-2025::Supplying and laying of 25x5 mm size copper earthing conducters along with cable/duct bellow ground including connection/ terminating with nut bolt spring wash etc are required
OD162915/2024-2025:Supplying and laying of 25x3 mm size copper earthing conducters along with cable/duct bellow ground including connection/ terminating with nut bolt spring wash etc are required
OD162910/2024-2025::Supplying and laying of 6 SWG copper wire conductor along with cable/duct bellow ground including connection/ terminating with nut bolt spring wash etc are required
OD162912/2024-2025:Transportation ,erection testing and commissioning of MSB .,SSB ,MCC
OD162911/2024-2025:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B
OD162942/2024-2025:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable size GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
OD162944/2024-2025:Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
OD162908/2024-2025:Supplying and fixing yard lighting with GI pole and LED light 35 W
OD162948/2024-2025:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch
OD162945/2024-2025:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet
OD162940/2024-2025:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
OD162943/2024-2025:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
OD162939/2024-2025:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)
OD162949/2024-2025:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm)
OD162917/2024-2025:Supplying and laying following size of 1.1KVPVC insulated and armoured heavy duty aluminium cable 3.5CX240sqmm as per IS543C1
OD162913/2024-2025:Supplying and laying PVC insulated and PVC sheeted / XLPE/ power cable of 1.1 KV grade folloewing size in masonry open duct as required (S&L of 3x2.5 sqmm copper armored cable)
OD162925/2024-2025:Supplying and laying of following size of 1.1 KV grade PVC insulated armored heavy duty aluminium cable as per I S through built-in trenches/ cable trays including clamping 3.5 x 95 sq mm ( two run)
OD162938/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5C X 95 sq. mm (45mm)
OD162922/2024-2025:Supply,conveyance,installation,testing and commissioning of 1200 mm sweep-5 star rated ceiling fan using standard accessories excluding resistant type regular ,wiring the down rod with 16/0 .2mm PVC insulated and PVC sheathed 650/1100 V grade 3 core round copper conductor flex wire or with extended with
OD162929/2024-2025:Supplying and laying one number PVC insulated and PVC sheeted / XLPE/ power cable of 1.1 KV grade folloewing size in masonry open duct as required (S&L of 3.5Cx70sqmm copper armored cable) (Two run)
OD162914/2024-2025:(cabling )supply laying testing and commissioning of the following size.PVC XLPE insulated shelthed armoured aluminium conductor cable 1100 /11000 volts grade clamped on wall / cieling with Clamps and saddle clips partly laid in cable tray partly laid in trench for 4Cx16 sq mm PVC XLPE aluminium cable
OD162934/2024-2025:Lighting Distribution board (LDB)-Supply,erection, testing and commissioning of MCB distribution board comprising to the following. 40A TPN 4 pole MCB 1 No. as incomer with 40A 30mA RCCB, 18 nos 6 AMPS SP MCB as outgoings, &With tinned copper busbars/cables, interconnection, housed in a suitable metal enclosure as per KEI standards fixed in open system
OD162926/2024-2025::supply and wiring light points with 6A plate ceiling of according to various 732- 1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 3419 -1988 fixing the conduit using methyl saddles spacing not exceeding 50cm concealed suitably and with 1 sq mm FR PVC insulated standed single core copper conductor cable 650 B grade including providing switch board main and continuous earthing earth socket brass Bolt and nuts crimpling soldering etc compete with suitable size modular type of metal switch boxes modular type of front plates (white) etc up to and including 6A modular type SP switches and making good the surface of wall colour washing etc complete all the terminations in switich boards and the DB"s shall be tinned and wires shall be drawn and fixied along the Periphery of the box using suitable Ties tie mounts etc. as require
OD162921/2024-2025:Supply, conveyance and installation testing and commissioning the light fittings of 1200 mm 1-20 w LED lamp with box type fluxure made from CRCA sheet 0.5 mm thickness with all accesseries and lamps directly on wall and giving connections with 16/0.2 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required.
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5.1.3:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
OD162954/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2X 70 sq. mm (38mm)
OD162935/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2 X 50 sq. mm (35mm)
OD162947/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE Copper conductor cable of 1.1 KV grade as required. 2Cx2.5Sqmm
OD162952/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2X 240 sq. mm (62mm)
OD162946/2024-2025:Supply and Laying 2.5 sqmm 2 core PVC / XLPE insulated armoured control cables with copper conduct1ors for working voltages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE
OD162937/2024-2025:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 3.5 core 35 sq mm with factory made clamp
OD162941/2024-2025:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2X 35 sq. mm (32mm)
SUPPLY AND ERECTION OF 4Nos. (1 No. standby)90 HP PUMP SET
OD163085/2024-2025:Supply and installation of 1 hp Vaccum pump an allied works.
SUPPLY AND ERECTION OF GAS CHLORINATOR AND CYLINDER
OD162905/2024-2025:Supply, erection and commissioning of wall mounted type pressure feed vaccum operated<br>gas chlorinator suitable for injecting chlorine gas 0.5kg/hour to 5kg/hour into pumping main of a maximum pressure<br>of 15kg/cm2 with chlorine block assembly consist of chlorine inlet assembly and hast alloy "C" Spring glass tube,<br>rotameter, with teflon float, injector assembly made out of rigid PVC sheet, Teflon diaphragm loaded with hast-alloy<br>"C" Spring and water pressure gauge etc. suitable capacity 3ph/1ph submersibble pump set , with panel board and<br>20m of cable, submersible pump set chamber madeout of PVC, chlorine gas control valve, teflon pipe with hast-alloy<br>'C; connection in both ends, cylinder clamp etc, complete.
OD162906/2024-2025:Supply of 100kg capacity filled chlorine cylinder with necessary test certificates.
SUPPLY ERECTION TESTING & COMMISSIONING OF 5 TONNE CAPACITY CRANE
OD162903/2024-2025:Design manufacture and supply of HOT overhead traverse trolley crane 5 tonne capacity chain pulley block and geared trolley having wall to wall horizontal movement etc for smooth functioning of the crane as per IS Specification including all fittings and all incidental charges including painting the exposed surface with following specifications. Type and construction of crane Single girder HOT (Design code IS 3832) Hook IS 8610 Load chain IS 6216(Alloy steel Grade 80) Hand chain IS 2420 MS Grade 30 brake type self actuating screw friction and disc type(width 8.60m)
OD162904/2024-2025:Errection Lubrication testing and commissioning of HOT over head crane over the RS Joist fixed on corbell of RCC Pillers and also fixing the end of LT girder to the sides suitably and also providing with suitable end steppers including provision for box type carriage fabricated from rolled steel section and fixurs and drives like gears wheels axies rubber buffers bearing etc .The work also consist of all tools and equipments ,labour supervision ,load testing all safty devices and commissioning the crane after completion of work in all respect
10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Construction of Transformer room
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
5.33.1:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level
5.33.2:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
11.3.1:Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
50.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
50.2.33.6:Cutting branches of trees overhanging above any structures of girth between 60cm to 90cm including stacking of serviceable materials and disposal of unserviceable material, cost of labour, hire charges of rope and pully etc without making any damages to nearby structures etc complete
50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
10.6.3:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x0.90 mm M.S. laths with 0.90 mm thick to cover
10.7:Providing and fixing ball bearing for rolling shutters.
10.9:Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).
13.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
VR7Infrastuctures (BID ID -2015354)
M J Thomas (BID ID -2015974)
Bidder Name
V.C. Sreekumar
M J Thomas
VR7Infrastuctures
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1119454.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .