Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹99.9 LAccepted-AOC | L1 | Accepted-AOC 1st lowest bidder | |
| 2 | L2₹100.0 L+₹5,665.83 (0.06%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest bidder | |
| 3 | L3₹100.0 L+₹6,161.64 (0.06%)Rejected-Finance BB 52 SECTOR 1 SALT LAKE CITY KOLKATA 700 064 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700064 | L3 | Rejected-Finance 3rd lowest bidder |
| Sl No | Description | Qty | Unit | MANTURAM INFRASTRUCTURE PVT. LTD. L1 | APRJ CONSTRUCTIONS PVT. LTD. L3 | WORKSAFE INFRA LLP L2 |
|---|---|---|---|---|---|---|
| 1.00Supply, Installation, Testing & Commisssioning of New star-Delta Starter & DOL Starter with Termination & Connection for 3Ph, 15KW, 3Ph 9.3KW & 1Ph, 2KW Pump & Repairing, Re-installation, Re-Commissioning & Alignment of steel structure support of Plummer Block of Non-Clog Vertical Type 15KW,9.3KW & 2KW Pump Motor Set of Sewage Pumping Station (SW-01) | ||||||
| 1.01 | Supply, Installation, Testing & Commisssioning of New star-Delta Starter with Termination & Connection for 3Ph, 15KW Pump including removing of the existing starter panel | 2 | Each | 2,30,000 ₹2,74,114 Lowest | 2,30,200 ₹2,74,352.36 | 2,30,100 ₹2,74,233.18 |
| 1.02 | Supply, Installation, Testing & Commisssioning of New star-Delta Starter with Termination & Connection for 3Ph, 9.3KW Pump removing of the existing starter panel | 1 | Each | 1,00,000 ₹1,19,180 Lowest | 1,00,200 ₹1,19,418.36 | 1,00,100 ₹1,19,299.18 |
| 1.03 | Supply, Installation, Testing & Commisssioning of New DOL starter. for 1Ph, 2KW Pump | 1 | Each | 6,000 ₹7,150.8 Lowest | 6,050 ₹7,210.39 | 6,040 ₹7,198.47 |
| 1.04 | Repairing ,Refixing of MCC panel 100A outgoing Feeder extended handle. | 2 | Each | 2,000 ₹2,383.6 Lowest | 2,040 ₹2,431.27 | 2,020 ₹2,407.44 |
| 1.05 | Repairing, Re-installation, Re-Commissioning & Alignment of steel structure support of Plummer Block of Non-Clog Vertical Type 15KW Pump Motor Set including supply of all accessories &1.0 mtr. pipes (QUOTATION) | 2 | Each | 8,00,000 ₹9,53,440 Lowest | 8,01,000 ₹9,54,631.8 | 8,00,800 ₹9,54,393.44 |
| 1.06 | Repairing, Re-installation, Re-Commissioning & Alignment of steel structure support of Plummer Block of Non-Clog Vertical Type 9.3KW Pump Motor Set including supply of all accessories &1.0 mtr. pipes (QUOTATION) | 1 | Each | 4,25,000 ₹5,06,515 Lowest | 4,25,500 ₹5,07,110.9 | 4,25,600 ₹5,07,230.08 |
| 1.07 | supplying & Replace of 2KW Pump Motor cupling, including removing of cupling (QUOTATION) | 1 | Each | 45,000 ₹53,631 Lowest | 45,010 ₹53,642.92 | 45,015 ₹53,648.88 |
| 1.08 | Remove Rust/Paint: Use a wire brush, sander, or angle grinder to remove old, flaking paint and surface rust. Thoroughly clean the surface with a degreaser or mineral spirits to remove oil and grease, ensuring proper paint adhesion. Apply a rust converter/inhibitor to any remaining rust to prevent further corrosion Use painter's tape to cover areas that should not be painted, such as brass fittings, logos, or functional parts. Apply a high-quality, corrosion-resistant metal primer (such as an epoxy zinc phosphate primer). Ensure the primer is compatible with the material of the pump/motor (usually cast iron or aluminium). Use a durable industrial paint, such as a 2-part epoxy, polyurethane, or oil-based enamel, which resists moisture and chemicals. Apply the paint in thin, even coats using a brush, roller, or spray gun. If the motor runs hot, use a specialized engine enamel or high-heat primer (resistant up to 500°F or higher). For a vintage look, you can apply dark wax to the paint. Reassemble the pump once fully cured.(QUOTATION) | 4 | Item | 80,000 ₹95,344 Lowest | 80,040 ₹95,391.67 | 80,060 ₹95,415.51 |
| 2.00Supply and Installation of new overload relay for 3Ph- 22KW Pump, 3Ph-11KW Pump & 1Ph-11KW Pum pincluding & complete overhauling, replacement of gasket, oil filtration, top up painting, replacement of silica gel breather of 250KVA Transformer and VLE. Of Sewage Pumping Station (SW-02) | ||||||
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
24 Feb 2026, 3:00 pmClosed
EE
Bidhannagar Municipal Corporation
Upgradtion of Existing Sewage Pumping Station) at SW-01 to 05 and 07 Sewage Pumping Station.
2026_MAD_1002448_1
NIQ NO. 2191/PWD(BMC), DTD. 09.02.2026
Open Tender
Miscellaneous Works
Item Rate
120 days
Bidhannagar Municipal Corporation
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹2 L
7 Apr 2026
9 Feb 2026
26 Feb 2026
9 Feb 2026
24 Feb 2026
9 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, Installation, Testing & Commisssioning of New star-Delta Starter & DOL Starter with Termination & Connection for 3Ph, 15KW, 3Ph 9.3KW & 1Ph, 2KW Pump & Repairing, Re-installation, Re-Commissioning & Alignment of steel structure support of Plummer Block of Non-Clog Vertical Type 15KW,9.3KW & 2KW Pump Motor Set of Sewage Pumping Station (SW-01) | |||||
| 1.01 | Supply, Installation, Testing & Commisssioning of New star-Delta Starter with Termination & Connection for 3Ph, 15KW Pump including removing of the existing starter panel | 2 | Each | - | - |
| 1.02 | Supply, Installation, Testing & Commisssioning of New star-Delta Starter with Termination & Connection for 3Ph, 9.3KW Pump removing of the existing starter panel | 1 | Each | - | - |
| 1.03 | Supply, Installation, Testing & Commisssioning of New DOL starter. for 1Ph, 2KW Pump | 1 | Each | - | - |
| 1.04 | Repairing ,Refixing of MCC panel 100A outgoing Feeder extended handle. | 2 | Each | - | - |
| 1.05 | Repairing, Re-installation, Re-Commissioning & Alignment of steel structure support of Plummer Block of Non-Clog Vertical Type 15KW Pump Motor Set including supply of all accessories &1.0 mtr. pipes (QUOTATION) | 2 | Each | - | - |
| 1.06 | Repairing, Re-installation, Re-Commissioning & Alignment of steel structure support of Plummer Block of Non-Clog Vertical Type 9.3KW Pump Motor Set including supply of all accessories &1.0 mtr. pipes (QUOTATION) | 1 | Each | - | - |
| 1.07 | supplying & Replace of 2KW Pump Motor cupling, including removing of cupling (QUOTATION) | 1 | Each | - | - |
| 1.08 | Remove Rust/Paint: Use a wire brush, sander, or angle grinder to remove old, flaking paint and surface rust. Thoroughly clean the surface with a degreaser or mineral spirits to remove oil and grease, ensuring proper paint adhesion. Apply a rust converter/inhibitor to any remaining rust to prevent further corrosion Use painter's tape to cover areas that should not be painted, such as brass fittings, logos, or functional parts. Apply a high-quality, corrosion-resistant metal primer (such as an epoxy zinc phosphate primer). Ensure the primer is compatible with the material of the pump/motor (usually cast iron or aluminium). Use a durable industrial paint, such as a 2-part epoxy, polyurethane, or oil-based enamel, which resists moisture and chemicals. Apply the paint in thin, even coats using a brush, roller, or spray gun. If the motor runs hot, use a specialized engine enamel or high-heat primer (resistant up to 500°F or higher). For a vintage look, you can apply dark wax to the paint. Reassemble the pump once fully cured.(QUOTATION) | 4 | Item | - | - |
| 2Supply and Installation of new overload relay for 3Ph- 22KW Pump, 3Ph-11KW Pump & 1Ph-11KW Pum pincluding & complete overhauling, replacement of gasket, oil filtration, top up painting, replacement of silica gel breather of 250KVA Transformer and VLE. Of Sewage Pumping Station (SW-02) | |||||
stage.html
html • 0.05 MB
technical_2456887.pdf
techsummary_2456887.pdf
finance_2456887.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
Tendernotice_2.pdf
PDF • 7.79 MB
BOQ_2456887.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .