Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹92.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹93.8 L+₹92,890.59 (1.00%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹92.8 L
EMD Value
₹1.9 L
Closing Date
27 Jan 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Addl. Chief Engineer cum Director, PWD, BTC
O/o the Addl. Chief Engineer cum Director, PWD BTC, Kokrajhar.
Const. of workshop Bldg. at ITI, Bhergaon in Udalguri District.
2023_BTC_28838_1
ACE-35/TECH/UDL(R and B)/IFB/2018-19
Open Tender
Civil Works - Building
Works
365 days
Udalguri Dist.
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,900
₹1.9 L
Yes
15 Feb 2023
13 Jan 2023
27 Jan 2023
13 Jan 2023
27 Jan 2023
13 Jan 2023
13 Jan 2023 - 27 Jan 2023
Amount
EARTH WORK 2.8. Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1. All kinds of soil.
2.15A. Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
STEEL WORK 5.22A. Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. 5.22A.6. Thermo-Mechanically Treated bars of grade Fe-500D or more
CEMENT CONCRETE WORK: 4.1. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 4.1.3. 1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources).
4.1. Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 4.1.4. 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 40 mm nominal size derived from natural sources
5.1. Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 5.1.2. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
5.2. Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 5.2.2. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.3. Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from
4.10. Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
SHUTTERING & FORMWORK: 5.9. Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1. Foundations, footings, bases of columns, etc. for mass concrete
5.9.5. Lintels, beams, plinth beams, girders, bressumers and cantilevers
5.9.6. Columns, Pillars, Piers, Abutments, Posts and Struts
BRICK WORK: 6.2. Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: 6.2.1. Cement mortar 1:4 (1 cement : 4 coarse sand)
6.13. Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2. Cement mortar 1:4 (1 cement :4 coarse sand)
PLASTERING WORKS: 13.2. 15 mm cement plaster on the rough side of single or half brick wall of mix: 13.2.1. 1:4 (1 cement: 4 fine sand)
13.3. 20 mm cement plaster of mix : 13.3.1. 1:4 (1 cement: 4 fine sand)
PAINTING: 13.26. Providing and applying plaster of paris putty of 2 mm thickness overplastered surface to prepare the surface even and smooth complete.
13.43.1. Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer
13.48A. Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade /Company Depot Tinted with silicon additives 13.48A.1. New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
STEEL WORKS 10.3. Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
10.1. Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
ROOFING 12.1. Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.2. 0.80 mm thick with zinc coating not less than 275 gm/ m2
Internal Water Supply & Sanitary 18.15. Providing and fixing brass bib cock of approved quality: 18.15.2. 20 mm nominal bor
18.16. Providing and fixing brass stop cock of approved quality 18.16.2. 20 mm nominal bor
18.9. Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 18.9.1. 15 mm dia nominal outer dia pipes
18.9.2. 20 mm dia nominal outer dia pipes
18.9.3. 25 mm dia nominal outer dia pipes
18.9.4. 32 mm dia nominal outer dia pipes
18.9.5. 40 mm dia nominal outer dia pipes
18.9.6. 50 mm dia nominal outer dia pipes
18.10. Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc Internal work - Exposed on wall 18.10.1. 15 mm dia nominal bore
18.12. Providing and fixing G.I. pipes complete with G.I. fittings Internal work - Exposed on wall 18.12.2. 20 mm dia nominal bore
18.12.4. 32 mm dia nominal bore metre
18.12.5. 40 mm dia nominal bore
18.13. Providing and fixing gun metal non- return valve of 18.13.1. 20 to 40 mm nominal bore
18.17. Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 18.17.1A. 20 mm nominal bore
18.17.2. 32 mm nominal bore
18.17.3. 40 mm nominal bore
18.18. Providing and fixing gun metal non- return valve of 18.18.1. 15 mm nominal bore
18.18.2. 20 mm nominal bore
18.18.3. 25 mm nominal bore
18.21. Providing and fixing uplasticised PVC connection pipe with brass unions: 18.21.1. 30 cm length 18.21.1. 15 mm nominal bore
18.21.2. 20 mm nominal bore Reducing Socket, bend, tee, etc.
Internal Electrification 1.10. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.10.1 Group A
1.10.2. Group B
1.10.3. Group C
1.14. Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.14.4. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
1.14.10. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
1.14.11. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
1.24. Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1.24.1. 5/6 A switch
1.24.3. 15/16 A switch
1.24.4. 3 pin 5/6 A socket outlet
1.24.5. 6 pin 15/16 A socket outlet
1.25. Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.26. Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.27. Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1.27.2. 3 Module (100mmX75mm) (Power plug)
1.33. Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1.36. Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm thick steel conduit, aluminium cast back plate and brass holder complete, including wiring the down rod with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and painting etc. as required.
1.48. Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
2.1. Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 2.1.2. 63 A TP&N
2.2. Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 2.2.1. 100 A, 16 KA,TPMCCB
2.2.2. 125 A, 16 KA,TPMCCB
2.3. Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/Isolator) 2.3.2. 8 way, Double door
2.5. Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBS (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 2.5.1. 4 way (4+12), Double door
2.10. Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.10.1. Single pole
2.10.3 Double pole
2.12. Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.12.1. 40 A
2.14. Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.14.2 40 A
2.15. Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 2.15.3 63 A
5.2. Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
5.6. Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.7. Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
5.17. Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
5.18. Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
7.1. Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.1.2 Above 35 sq. mm and upto 95 sq. mm
12.34. Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV/HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
13.13. Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
MR-1. Supplying including fitting fixing of 18 Watt Slim LED batten with polycarbonate round-shape diffuser. Grey end cap housing is an ideal replacement solution for existing battens/ fluorescent lamps with elegantly designed caps etc. as required and directed by the Deptt.
MR-2. Supplying with including fitting fixing of ADORE LED PLUS 9 W/ 10 W. etc. as directed by the Deptt.
MR-3. Supplying with including fitting fixing of Ceiling fan etc. as directed by the Deptt.
MR-4. Supplying with fitting & fixing of highly effective front openable 45W IP66 Street light/Campus light with aluminium pressure dia-cost housing, toughened glass in the front and peanut lens for batwing light distribution to ensure uniform light distribution, higher spacing between poles and maintenance free system etc. as required and as directed by the Department (Orient, Bajaj, Havells or equivalent make). Orient Make 45 W Street light / Campus light (LSFT-045-C)
MR-5. Supplying with fitting and fixing of Motor Pumps set (Crompton / Kirlosjar / Usha or equivalent make) as required and directed by the department. ( Crompton Residential 2 HP Motor Pumps set (Model No. MINI EVERSET)
MR-6. Supply of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Gd. Solid Aluminum conductor up to 10 sqmm, balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminum wire for single core up to 70 sq. mm, balance Aluminum strip, Glavanised wire for cables up to 2 x 10 sq. mm, 3 x 10 sq. mm, 4 x 6 sq. mm & balance all galvanized steel strip), extruded PVC Type ST2 sheathed, 650/1100 V grade as per IS 7908 (Part-I) 1988 armored U.G. cable as specified and directed by the deptt. (Havells, RR, or equivalent make as approved by this Deptt.) 50.00 sq.mm 31⁄2 Core U.G. Cable
MR-7. Supply, installation and testing of floor mounted compartmentalized dust and vermin proof power distribution panel board (L.T- 3 ph, 415 V, AC 160 Amp) made of M.S. sheet of not less than 16 swg duly welded & Powder Coated with Grey colour to both in interior & exterior. All wiring for control & metering shall be done by multistranded PVC insulated Finolex make single core copper flexible cable of not less than 1.5 sq.mm. Size and will be properly harnessed and drawn neatly clamped for incoming & out going cables, 4 (Four) separately electrolytic grade Aluminium busbar (3 phase & Neutral) of 200 amps will be layed in separate chamber. All the outgoing cable of the MCCB/MCB up to cable alley connecter shall be connected by flat/round/flexible Copper cable etc. as required and directed by the departmen.
MR-8. Supply, Installation and Commissioning of LED 24 Watt Solar Street light etc. as required complete as specified & directed by the Deptt. (MNRE approved).
MADAN DEBNATH
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .