REPAIRS AND MAINTENANCE TO PUMPS AND WATER TREATMENT PLANT AT MASIMPUR MIL STN UNDER GE SILCHAR
2020_MES_317198_2
8531/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
MASIMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE SILCHAR
₹40,000
Yes
28 Mar 2020
15 Feb 2020
24 Feb 2020
16 Feb 2020
22 Feb 2020
16 Feb 2020
Amount
Material and labour for taking out 30 HP capacity Electric Motor and Vertical Turbine Pump at low lift of Main Pump house by unbolting of foundation nut, bolts, disconnecting the water and electric connnection and taking out defective turbine pump set including column pipes/line shaft from Jack well, after replacing defective spare parts, reassembling the pump set and lowering of repaired turbine pump set including column pipes/line shaft in the jackwell and making water and electric connection as per existing for running of pump motors complete all as specified. Note:- Spare parts shall be measured and paid separately under appropriate item.
Supply only Top Shaft (SS) as sample given.
Supply only Bottom shaft (SS) 5 Feet Long
Supply only Line shaft (SS) 10 feet long 25mm Dia
Supply only Pump Bowel ( Body) as sample given
Supply only Rubber bearing for bearing retainer
Supply only VT Pump Line shaft coupling as sample given.
Supply only Suction case bushing made out of bronze.
Supply only Discharge case bushing made out of bronze
Supply only Intermediate Bowel bushing bronze
Supply only Intermediate rubber bushing
Supply only Impeller lock collect assy
Supply only Retainer bearing CI
Supply only Stud bolt ½ x2’’
Supply only Column pipe coupling
Supply only Stuffing Box suitable for 30 HP Vertical Pump Set.
Supply only Impellers Brass Type suitable size for 30 HP VT Pump (including Bushing).
Supply only Shaft Sleeve 6" long with inner thread.
Supply only Shaft Sleeve 4" long with inner thread.
Supply only Top Column pipe 150mm size ( 5 feet long)
Supply only Bottom Column pipe 150mm size ( 5 feet long)
Supply only Pump shaft Stainless steel of appropriate size
Supply only Reduced type pump shaft to Line shaft coupling.
Supply only Column pipe with Socket of size 150 mm bore having threading in mm type on outer surfaces both sides (ISI marked).
Material and labour for taking out following capacity centrifugal pumping sets from foundation, disconnecting the water and electric connnection and transporting to work shop, opening the pump for inspecting all parts to identify defective parts, cleaning / servicing & greasing including refixing and replacement of the defective items including testing and commissioning complete all as specified. (i) Gun metal bush for pump - 1 Set. (ii) Remetalling, grinding turning & facing of impeller of pump if required. (iii) Replacement of gland packing. (iv) Replacement of gland nut bolt & replacement of damaged foundation bolts. (v) Reassembling of pumping set and transporting back to pump house, installing, connecting with water & electric connection and testing for performance complete all as directed. Note:- Spare parts shall be measured and paid separately.
7.5 HP capacity
30 HP capacity
50 HP capacity
75 HP capacity
Supply only the following parts suitable for centrifugal pumpset 75 HP capacity :-
Roller type Bearing SKF-NU-411-304 D suitable for 75 HP pump set, Make:- NBC/SKF/FAG
Ball bearing SKF-7311BEP suitable for 75 HP pumpset Make:- NBC/SKF/FAG
Cast iron impeller for 75 HP Centrifugal pump as per existing.
Cast Iron Bearing Housing as per existing for NDE of 75 HP centrifugal Pump
Cast Iron Bearing Housing as per existing for DE of 75 HP centrifugal Pump
Pump Shaft made of MS Steel Iron with key and necessary nuts & bolts, Jam Nut suitable for75 HP Pump Set of existing size.
Pump shaft sleeve suction side
Pump shaft sleeve delivery side
Pump distance sleeve
Pump bearing lock nut
Set of O rings
Supply only the following parts suitable for centrifugal pumpset 50 HP capacity:-
Ball bearing SKF-309EC suitable for 50 HP induction motor Make:- NBC/SKF/FAG
Ball bearing SKF-7309 BEC suitable for 50 HP induction motor Make:- NBC/SKF/FAG
Supply only Cast iron impeller for 30 HP mono block pump as per existing suitable for centrifugal pumpset 30 HP capacity.
Supply only Pump Shaft made of MS Steel Iron with necessary nuts & bolts, Jam Nut suitable for 7.5 HP Pump Set of existing size suitable for centrifugal pumpset 7.5 HP capacity.
Supply only the following parts suitable for Vertical induction motor of capacity 30 HP, as per sample site requirement.
Key for motor coupling.
Motor base bottom Flange of 150mm dia.
Motor Terminal Plate
Adjusting Nut and Key.
Ball bearing SKF-6212/C3 Make:- NBC/SKF/FAG
Ball bearing SKF-6310/C3 Make:- NBC/SKF/FAG
Ratchet locking head with plunger as per existing sample
Material and labour for taking out electric motor for rewinding of capacity 30 HP vertical induction motor 3 phase 415 Volts, by disconnection from terminal & pump coupling & foundation complete removing of motor, carrying to workshop for rewinding after opening motor, removing burnt copper wire from stator, cleaning all parts throughly, rewinding motor stator with same gauge and same No of turns of super enamelled copper wire including insulating materials and varnishing, heating/ bakinf up to desird temperature etc and Painting the repaired motor externally with two coats of synthetic enamel paint and reassembling/ fixing the motor and pump set at its original location, making proper allignment connecting the motor with supply and testing complete all as directed
All as per item No. 8 above but of Horizontal Induction Motor of capacity 75 HP, 3 phase 415 Volts.
All as per item No. 8 here-in-before but of Horizontal Induction Motor of capacity 50 HP, 3 phase 415 Volts.
All as per item No. 8 here-in-before but of Horizontal Induction Motor of capacity 7.5 HP, 3 phase 415 Volts.
Dismantling of Monoblock Pump set of 2 HP for taking out of burnt-out winding and supply with new Enamelled Copper wire of required size and required quantity, including all required insulation materials, terminal leads, bearing both DE and NDE side of existing size, etc complete all as directed
Supply and fix in repairs Rubber Coupling Round Type suitable for 75 HP as per sample site requirement.
Supply and fix in repairs Star Type Rubber Coupling (Love&joy Coupling) suitable for 75 HP as per sample site requirement.
Supply and fix in repairs Ring Gland Jam Nut suitable for 75 HP pump site requirement.
Supply and replace the following parts suitable for induction motor of capacity 50 HP.
Supply and fix in repairs Rubber type tyre Coupling suitable for 50 HP as per sample site requirement.
Supply and fix in repairs Ring Gland Jam Nut suitable for 50 HP pump site requirement.
Preventive maintenance of Air Compressor installed with filter plant at Main pump House,Kalibari complete for smooth functioning like heat vernishing, changing minor parts like gaskets, washers and painting with one coat of synthetic enamel plaint of existing colour complete all as specified and directed.
Supply and fix in repairs V-Belt of existing size suitable for air Compressor of water treatment plant.
Supply and fix in repairs Stuffing Box for 30 HP vertical turbine pumping set with Gland Bushing Sleev as per existing size and material complete including required Nuts, Bolts and washer of required size all as specified and directed
Supply and fix in repairs Pressure Meter Gauge of any range and supply new Pressure Gauge of Range 0 to 35 Kg/Cm²
All as per item No. 20 above but of range 0 to 28 Kg/Cm².
Dismantling of Worn out Pump Set Foundation Channel by removing of C/F Pump Set of 75/50 HP, including taking out of Foundation Nut, Bolt and washer complete all as directed
Supply and fixing of Foundation Channel for 75 HP Pump Set made of Iron duly painted with red oxide primer and non-corosive Black Paint, with all necessary Nut, Bolts, washer including cement work with PCC 1:3:6 type C2 using 20mm graded aggregate and installation of Pump Set in same position complete all as specified and directed.
Material and labour for repair of clarifloculator system by replacing all unserviceable parts likes (a) to (f) below including replacement of clarifloculator scraper arms, blades of fibre glass sizes a s per existing, MS equal angle, MS Sheet including neessary cutting, welding, riveting and providing two coat of spray painting with synthetic enamel paint over a coat of red oxide, Zinc chromo Primer includingc Cleaning of Clarifloculator of capcity 1,20,000 Gln/hr, Areator, water channel by means of wire brush, including floor and wall inside, repair the crack on concrete wall as required including preparation of surface and writing of "Capacity ,tank cleaned on Date, month & year complete all as specified and directed. (a) Centre ball bearing as per existing - 01 No as per sample. (b) MS shaft coupling suitable for 40mm dia MS shaft including nuts, bolts and washers etc- 01 Set as per sample. (c) Slip Ring Assembly with Carbon as per sample. (d) Bowl gear pinion - 01 No as per sample. (e) Conveyer chain of mild steel for gear pinion assembly - 01 No as per sample. (f) Wheel bush - 01 set as per sample. (g) Scope of work includes repairing of existing tile surfaces by providing new Non Skid ceramic colour tiles 7 to 8mm thick (square/rectangular), area of each tile exceeding 0.06 but not exceeding 0.11 sqm of matching colour as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layers in CM 1:6, of approximately 5 Sqm area all as directed by Engr-in-Charge.
Material and labour for cleaning of Under Ground sump of following capacity, manually as described below and all as directed by Engr- in charge. (a) Suitably blocking the incoming and outgoing wash out pipes for avoiding mud and foreign meterials deposited in the sump getting into pipes and chocking it prior to starting the cleaning. (b) Bail out complete water remaining in the U.G Sump before cleaning the mud and other deposits. (c) Filling up the U.G Sump full and feed the affected residential/OTM consumers enough water to sustain during the sump cleaning period. (d) Manually remove deposited mud sludge and other foreign particles and deposit the same separately away from tanks in low laying areas and levelling as directed by Engr- in- charge.. (e) Clean the floor wall and dome of theU.G Sump by jetting water using rotary pressure jets, remove the sludge so deposited completely by rubbing the wall / floor with brushes and repeat removal and depositing (Approved detergent shall be used) (f) Disinfect the tank with FOA / WHO specified chemical and make the tank totally bacteria free. (g) Apply a coat of white cement paint out side surface area as per directed by Engr- in charge. (h) Writing of the date of cleaning of the water tank with white letters on black background
Under ground sump of 100000 gallon cap at Srikona.
Under ground sump of 20000 Gln capacity.(Srikona)
Under ground sump of 10000 Gln capacity.(Srikona)
Under ground sumps of 70000 Gln capacity.(Main pump house)
Under ground sumps of 40000 Gln capacity.(Main pump house)
Under ground sumps of 15000 Gln capacity.(ARO)
Under ground sumps of 10000 Gln capacity.(NCC)
Supply and fix Cast iron sluice valve with stainless steel spindle and cast iron hand wheel complying with IS:14846-2000, class PN 1.6 both ends flanged with 2 Nos rubber insertion gasket joints, nuts, bolts & washers of required size & Nos complete including removing of old unsv one of bore size 250 mm complete all as specified.
Supply and fix 150 mm bore Cast iron Non Return Valve both end flanged ISI marked with 2 Nos rubber insertion gasket joints, nuts, bolts & washers of required size & Nos complete including removing of old unsv one complete all as specified.
All as per item No. 27 above but of Size 100 mm bore.
Supply and fix cast iron body foot valve and gun metal of working parts 150 mm, all as specified and directed.
All as per item No. 29 above but size 100 mm.
All as per item No. 29 here-in-before but size 80 mm of body and working part made of brass complete.
All as per item No. 31 above but size 50 mm.
Supply and fix in repair MS nut, bolts with washer of various size as required while carrying out repair work of pump set, sluice valve, NRV, Foot valve etc as directed.
Demolition old unserviceable broken valve pit and material and labour for construction of valve pit of brick masonry of size (2 x 2 x 1.5 m) internal dimension complete with Angle Iron, 3.15mm thick MS sheet cover and locking arrangement including excavation and earth work and P.C.C 1:3:6 type with provision of two coat of synthetic enamal paint over one coat of red oxide primer complete.
Supply and fix in repair MCCB four pole 415 volts 50 Hz, 250 amps, with rupturing capacity 25 KA complete all as specified and directed including taking down old unserviceable MCCB. ICS = 100% ICU
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 125 amps, with rupturing capacity 25 KA complete all as specified and directed including taking down old unserviceable MCCB. ICS = 100% ICU
Supply and fix Single phase preventor suitable for Induction motor 3 Phase, 415 volts, 50 Hz including PVC wire required for fixing single phase preventor and all connection, including removing of old unserviceable all as directed.
Supply and fixing the following materials as in repair including all internal wire connections of required size and modifications in existing panel of Low Lift, High Lift and NCC complex pump house as to fit the item in proper position including taking down old one :-
Power Contactor - 100 Amp, 415 Volt, 50 Hz, Type-ML6.
Power Contactor-40 Amp, 415 Volt, 50 Hz, Type-ML4,
Power Contactor-32 Amp, 415 Volt, 50 Hz, Type-ML2,
Electronic Timer, Range: 9 - 30 Sec, 240 Volt, 50Hz, Type: ET100, Make:- L&T or equivalent make approved by GE.
Electronic Timer, Range: 36 - 120 Sec, 240 Volt, 50 Hz, Type: ET100, Make :- L&T or equivalent make approved by GE.
Digital Ammeter CT operated.
Bakelite Fuse - 01 Set
Voltmeter of range 0 to 500 volt (Digital type)
Indicating lamp Red/Yellow/ Blue of size as per existing complete.
Material and labour for angle iron channel of various size chequred plates including cutting, welding, fixing at location as required shape all as directed (cost includes the cutting, welding and other T&P required at site)
Repair to pressed steel over head water tank at MH area of capacity 10000 Gln for arresting the leakage by means welding, patch work with steel plates, supporting angle iron of existing thickness and size etc and replacement of worn out nuts, bolts as directed for stoppage of water waste complete incl making of proper locking arrangement of tanks cover all as specified.
Material and labour for cleaning of over head reservoirs of capacity 60000 GLN at RR Hill , manually as described below and all as directed by Engr- in charge. (a) Suitably blocking the incoming and outgoing wash out pipes for avoiding mud and foreign meterials deposited in the reserviors getting into pipes and chocking it prior to starting the cleaning. (b) Bail out complete water remaining in the over head reservior before cleaning the mud and other deposits. (c) Filling up the over head water tank of user full and feed the affected residential/OTM consumers enough water to sustain during the resevior cleaning period. (d) Manually remove deposited mud sludge and other foreign particles and deposit the same separately away from tanks in low laying areas and levelling as directed by E.I.C. (d) Clean the floor wall and dome of the resevvior by jetting water using rotary pressure jets, remove the sludge so deposited completely by rubbing the wall / floor with brushes and repeat removal and depositing (Approved detergent shall be used) (e) Disinfect the tank with FOA / WHO specified chemical and make the tank totally bacteria free. (f) Apply a coat of black bituminous paint on tank man hole covers including surface preparation. (g) Writing of the date of cleaning of the water tank with white letters on black background.Remove the blockage from inlet / outlet over flow pipes, refill the tank with water and supply water at supply timings, ensure satisfactory distribution. (h) M&L for arresting leakages by means of weilding, patch work with required size of MS Sheet
All as per item No. 41 above but of capacity 35,000 gallons (Lorry Point)
All as per item No. 41 but 20000 Gln capacity (Over head) (Near Bde cmdr Res)
All as per item No. 41 but 15000 Gln capacity (Over head) (NCC)
All as per item No. 41 but 10000 Gln capacity. (Over head) (MH & Reservoir)
Supply and lay cable or fixed to wall/floors XLPE insulated, PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded alluminium conductors, 1100 volt grade, 50 sqmm, 3.5 core all as specified including taking out old unserviceable.
Supply & Lay synthetic insulating mat of size 2 mtr X 1 mtr of 10mm thick ISI marked.
m/s builders and suppliers
M/S PIJUSH BHATTACHARJEE
M/S TAPAN KUMAR RAY
M/S P K ROY AND SONS
M/S MOLOY KUMAR DEY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .