| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.2 LAccepted-AOC 184 187 TEMPLESTEPS BLOCK ANNASALAI LITTLEMOUNT CHENNAI CHENNAI TAMIL NADU 600015 | CHENNAI | TAMIL NADU | 600015 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹73 L+₹76,000 (1.05%)Rejected-Finance SCHINDLER HOUSE MAIN STREET HIRANANDANI GARDENS POWAI MUMBAI 400076 MAHARASHTRA INDIA | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400076 | L2 | Rejected-Finance 2ND LOWEST BIDDER | |
| 3 | L3₹74.7 L+₹2.5 L (3.41%)Rejected-Finance 5TH FLOOR DP 9 P T I BLDG SALT LAKE SALT LAKE KOLKATA WEST BENGAL 700091 | KOLKATA | KOLKATA | WEST BENGAL | 700091 | L3 | Rejected-Finance 3RD LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹2.9 L
Closing Date
11 Nov 2020, 2:00 pmClosed
Office of SE,SWEC,PWD, MIDNAPORE
OFFICE OF THE SUPERINTENDING ENGINEER (P.W.D) South-West Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
Construction of (Gplus4) District Judge Court building within the campus of District Judge court in the district of Purulia---SITC of energy efficient Passengers LIFTs
2020_WBPWD_300850_1
WBPWD/SE/SWEC/NIQ08/2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
180 days
PURULIA
Please refer Tender documents.
3 documents required · 3 mandatory
₹2.9 L
Office of SE / SWEC, PWD, Midnapore
7 Jul 2025
9 Oct 2020
13 Nov 2020
9 Oct 2020
11 Nov 2020
14 Oct 2020
13 Oct 2020
Amount
Supply,Installation Testing & Commissioning Of normal energy efficient 13 passengers WITH Machine Room type lift(GUIDELINE- BIS CLAUSE NO- 5.9.3.1). [Make : OTIS / SCHINDLER / KONE ] Major specification are as follows : [ FOR New (G+4) District Judge Court Building, Purulia]
TYPE : Passenger CAPACITY (Kgs) : 13 PERSONS 884 KGS. SPEED (MPS) : 1 MPS. RISE ( m) : Ground floor to 4th floor about 16mtr. STOPS : 5 Stops & 5 opening (all opening on the same side) CONTROLLER TYPE : Microprocessor based DRIVE : VVVF (Closed Loop) Drive POWER SUPPLY : 400/415 Volts (3Phase AC) OPRATION : Full collective operation CAR GROUP : Two car (Duplex) MACHINE : PM Gearless (Located above shaft).Lift with machine room TRACTION MEDIA : stainless steel rope of required size / Flat Coated Steel Belt
CAR FINISH : Rear Mid Panel = Staineless Steel hairline finish Rear Corner Panels = Stainless Steel hairline finish Side Panels = Stainless steel hairline finish Front Panels = Stainless steel hairline finish FLASE CEILING TYPE : Standard FLASE CEILING FINISH : Stainless steel hairline finish VENTILLATION : Cross flow fan HAND RAILS : Stainless Steel hairline finish Handrails on rear car panels FLOORING : Granite Slab CAR DOOR FINISH : Stainless steel hairline finish LANDING DOORS FINISH : Stainless steel hairline finish FIRE RATED DOORS : Fire rating -60 mins PIT DEPTH:-1350 OVERHEAD:-4500 HOISTWAY DIMENSIONS (W x D - mm) : 2225 mm W x 2625 mm D CAR DIMENSION (W x D x H - mm) : 1600 mm W x 1350 mm D x 2200 mm D CAR HOISTWAY DOOR TYPE : Centrial opening (CO) doors
DOOR OPENING (W x H - mm) : 900 mm W x 2000 mm H DOOR OPERATOR : DC / AC Door Operator COP : Gien / braile Buttons in Stainless Steel hairline finish CAR POSITION INDICATOR : Dot matrix (RED LED) Scrolling Display /Backlit LCD HALL FIXTURES : Braile Micropush button with dot matrix display HALL FIXTURE FACE PLATE : Stainless steel hairline finish HALL BUTTON ARRANGEMENT : Hall Button with UP/DN at intermediate floor and only UP/DN at lowest / upper most floor.
STANDARD FEATURES : Anti- nuisance Car Call Protection, Independent Service (for Duplex only), Overload Device , Nudging, Emergency Firemen's Service, Emergancy Car Light Unit, Infrared Curtain Door Protection , Door time Protection, Emergencey Alarm Button, Extra Door time of Lobby & Parking , door Open/Close Button, Manual Rescue Operation , Auto fan Cut Off, steel rope drive. SAFETY FEATURES: a) Over Speed Protection b) Single Phase Protection c) Over Load Protection d) Phase faliure Protection e) Terminal Limit Switch f) Emergency Stop Switch g) Inter Locking Switch h) Reverse Phase Protection i) Delocking arrangement from Loading OPTIONS INCLUDED : Automatic Rescue operation, Voice Synthesizer, intercom.
Supply,Installation Testing & Commissioning Of energy efficient 13 passengers Patient's lift WITH Machine Room type lift(GUIDELINE- BIS CLAUSE NO- 5.9.3.1). [Make : OTIS / SCHINDLER / KONE ] Major specification are as follows : [ FOR New (G+4) District Judge Court Building, Purulia]
TYPE : Passenger CAPACITY (Kgs) : 13 PERSONS 884 KGS. SPEED (MPS) : 1 MPS. RISE ( m) : Ground floor to 4th floor about 16mtr. STOPS : 5 Stops & 5 opening (all opening on the same side) CONTROLLER TYPE : Microprocessor based DRIVE : VVVF (Closed Loop) Drive POWER SUPPLY : 400/415 Volts (3Phase AC) OPRATION : Full collective operation CAR GROUP : One car (Simplex) MACHINE : PM Gearless (Located above shaft).Lift with machine room TRACTION MEDIA : stainless steel rope of required size / Flat Coated Steel Belt
CAR FINISH : Rear Mid Panel = Staineless Steel hairline finish Rear Corner Panels = Stainless Steel hairline finish Side Panels = Stainless steel hairline finish Front Panels = Stainless steel hairline finish FLASE CEILING TYPE : Standard FLASE CEILING FINISH : Stainless steel hairline finish VENTILLATION : Cross flow fan HAND RAILS : Stainless Steel hairline finish Handrails on rear car panels FLOORING : Granite Slab CAR DOOR FINISH : Stainless steel hairline finish LANDING DOORS FINISH : Stainless steel hairline finish FIRE RATED DOORS : Fire rating -60 mins PIT DEPTH:-1350 OVERHEAD:-4500 HOISTWAY DIMENSIONS (W x D - mm) : 1925 mm W x 2350 mm D CAR DIMENSION (W x D x H - mm) : 1100 mm W x 2000 mm D x 2200 mm D CAR HOISTWAY DOOR TYPE : Centrial opening (CO) doors
DOOR OPENING (W x H - mm) : 800 mm W x 2000 mm H DOOR OPERATOR : DC / AC Door Operator COP : Gien / braile Buttons in Stainless Steel hairline finish CAR POSITION INDICATOR : Dot matrix (RED LED) Scrolling Display /Backlit LCD HALL FIXTURES : Braile Micropush button with dot matrix display HALL FIXTURE FACE PLATE : Stainless steel hairline finish HALL BUTTON ARRANGEMENT : Hall Button with UP/DN at intermediate floor and only UP/DN at lowest / upper most floor.
STANDARD FEATURES : Anti- nuisance Car Call Protection, Independent Service (for Duplex only), Overload Device , Nudging, Emergency Firemen's Service, Emergancy Car Light Unit, Infrared Curtain Door Protection , Door time Protection, Emergencey Alarm Button, Extra Door time of Lobby & Parking , door Open/Close Button, Manual Rescue Operation , Auto fan Cut Off, steel rope drive. SAFETY FEATURES: a) Over Speed Protection b) Single Phase Protection c) Over Load Protection d) Phase faliure Protection e) Terminal Limit Switch f) Emergency Stop Switch g) Inter Locking Switch h) Reverse Phase Protection i) Delocking arrangement from Loading OPTIONS INCLUDED : Automatic Rescue operation, Voice Synthesizer, intercom.
Supply,Installation Testing & Commissioning Of energy efficient 13 passengers fire lift WITH Machine Room type lift(GUIDELINE- BIS CLAUSE NO- 5.9.3.1). [Make : OTIS / SCHINDLER / KONE ] Major specification are as follows : [ FOR New (G+4) District Judge Court Building, Purulia]
TYPE : Passenger CAPACITY (Kgs) : 13 PERSONS 884 KGS. SPEED (MPS) : 1 MPS. RISE ( m) : Ground floor to 4th floor about 16mtr. STOPS : 5 Stops & 5 opening (all opening on the same side) CONTROLLER TYPE : Microprocessor based DRIVE : VVVF (Closed Loop) Drive POWER SUPPLY : 400/415 Volts (3Phase AC) OPRATION : Full collective operation CAR GROUP : Two car (Duplex) MACHINE : PM Gearless (Located above shaft).Lift with machine room TRACTION MEDIA : stainless steel rope of required size / Flat Coated Steel Belt
CAR FINISH : Rear Mid Panel = Staineless Steel hairline finish Rear Corner Panels = Stainless Steel hairline finish Side Panels = Stainless steel hairline finish Front Panels = Stainless steel hairline finish FLASE CEILING TYPE : Standard FLASE CEILING FINISH : Stainless steel hairline finish VENTILLATION : Cross flow fan HAND RAILS : Stainless Steel hairline finish Handrails on rear car panels FLOORING : Granite Slab CAR DOOR FINISH : Stainless steel hairline finish LANDING DOORS FINISH : Stainless steel hairline finish FIRE RATED DOORS : Fire rating -120 mins PIT DEPTH:-1350 OVERHEAD:-4500 HOISTWAY DIMENSIONS (W x D - mm) : 2225 mm W x 2625 mm D CAR DIMENSION (W x D x H - mm) : 1600 mm W x 1350 mm D x 2200 mm D CAR HOISTWAY DOOR TYPE : Centrial opening (CO) doors
DOOR OPENING (W x H - mm) : 900 mm W x 2000 mm H DOOR OPERATOR : DC / AC Door Operator COP : Gien / braile Buttons in Stainless Steel hairline finish CAR POSITION INDICATOR : Dot matrix (RED LED) Scrolling Display /Backlit LCD HALL FIXTURES : Braile Micropush button with dot matrix display HALL FIXTURE FACE PLATE : Stainless steel hairline finish HALL BUTTON ARRANGEMENT : Hall Button with UP/DN at intermediate floor and only UP/DN at lowest / upper most floor.
STANDARD FEATURES : Anti- nuisance Car Call Protection, Independent Service (for Duplex only), Overload Device , Nudging, Emergency Firemen's Service, Emergancy Car Light Unit, Infrared Curtain Door Protection , Door time Protection, Emergencey Alarm Button, Extra Door time of Lobby & Parking , door Open/Close Button, Manual Rescue Operation , Auto fan Cut Off, steel rope drive. SAFETY FEATURES: a) Over Speed Protection b) Single Phase Protection c) Over Load Protection d) Phase faliure Protection e) Terminal Limit Switch f) Emergency Stop Switch g) Inter Locking Switch h) Reverse Phase Protection i) Delocking arrangement from Loading OPTIONS INCLUDED : Automatic Rescue operation, Voice Synthesizer, intercom.
Terms & Conditions : 1. Estimated rate will be including delivery charge at work sites and all other charges & taxes. 2. Guarantee period : 12 months from the date of hand over after installation, Testing & commissioning. 3. Price variation clause will not be entertained. 4. Materials should be delivered at work sites in consultation with the concerned Executive Engineer, Purulia Electrical Division,P.W.Dte. 5. All sorts of Test Certificate must be submitted from the Agency / manufacturer company at the time of hand over after installation, Testing & commissioning/delivery of materials to the concerned officers. 6. Testing & commissioning has to be done.In presence of EIC 7. Any break down of lift accessories has to be repaired / replaced within 48 hours to his own cost.
SCHINDLER INDIA PRIVATE LIMITED
KONE ELEVATOR INDIA PRIVATE LIMITED
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .