Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.4 CrAccepted-AOC 3 SHITALNATH FLATE 1 NR KHANPUR JAIN TEMPLE OPP BANK OF INDIA SHAHPUR AHMEDABAD GUJARAT 380001 | AHMADABAD | GUJARAT | 380001 | ₹1.4 Cr | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹1.5 Cr+₹5.9 L (4.17%)Rejected-Finance KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | ₹1.5 Cr+₹5.9 L (4.17%) | L-2 | Rejected-Finance Being L-2 |
| 3 | L-3₹1.5 Cr+₹8.0 L (5.66%)Rejected-Finance HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | ₹1.5 Cr+₹8.0 L (5.66%) | L-3 | Rejected-Finance Being L-3 |
| 4 | L-4₹1.5 Cr+₹10.6 L (7.52%)Rejected-Finance SHOP NO 06 FIRST FLOOR OPP CHAMUNDA HOTEL AT BOKHIRA DIST PORBANDAR GUJARAT 360 579 | PORBANDAR | GUJARAT | 360579 | ₹1.5 Cr+₹10.6 L (7.52%) | L-4 | Rejected-Finance Being L-4 |
| 5 | L-5₹1.5 Cr+₹10.8 L (7.62%)Rejected-Finance PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | ₹1.5 Cr+₹10.8 L (7.62%) | L-5 | Rejected-Finance Being L-5 |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
23 Jul 2024, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
PROVN OF INDUSTRIAL RO PLANT WITH A CAPACITY OF 28000 LTRS PER DAY WATER STORAGE AND BORE WELL AS SPECIAL WORK AT 7M DET, OKHA
2024_MES_658605_1
8913/E8
Open Tender
Civil Works
Lump-sum
270 days
OKHA
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (Navy) Porbandar
₹2.0 L
Yes
15 Oct 2024
8 Jun 2024
27 Jul 2024
8 Jun 2024
23 Jul 2024
16 Jul 2024
Amount
SCH 'A' PART-I : "(BUILDING FOR HOUSING OF RO PLANT)" brought forwarded from Serial Page No. 19 (R)
SCH 'A' PART-II : "UG SUMP / SEIMENTATION TANK" Total of Schedule 'A' Part-V brought forwarded from Serial Page No. 22
SCH 'A' PART-III : "EARTH WORK & EXCAVATION" Total of Schedule 'A' Part-II brought forwarded from Serial Page No. 23
SCH 'A' PART-IV : "INTERNAL WATER SUPPLY" Total of Schedule 'A' Part-III brought forwarded from Serial Page No. 24
SCH 'A' PART-V: "INTERNAL ELECTRIC SUPPLY" Total of Schedule 'A' Part-IV brought forwarded from Serial Page No. 27
SCH 'A' PART-VI : "PCC PAVER BLOCK, ROAD/PATH" Total of Schedule 'A' Part-VI brought forwarded from Serial Page No. 28
SCH 'A' PART-VII "SEWAGE DISPOSAL" Total of Schedule 'A' Part-VII brought forwarded from Serial Page No. 30
SCH 'A' PART-VIII "FENCING AND GATE" Total of Schedule 'A' Part-VIII brought forwarded from Serial Page No 32
SCH 'A' PART-IX "EXTERNAL WATER SUPPLY" Total of Schedule 'A' Part-IX brought forwarded from Serial Page No.33
SCH 'A' PART-X "EXTERNAL ELECTRIC SUPPLY" Total of Schedule 'A' Part-X brought forwarded from Serial Page 34
SCH 'A' PART-XI"MISC WORKS"
"INTERNAL ELECTRIC SUPPLY"
Supply and fixing LED light fitting surface mounted 1'x1 ' of capacity 15Watt of 240V Environment friendly High quality LED flat panel for surface mounting which provides soft-light and glare free symmetrical illumination complete with all connected accessories. Make:- havells catpart No. PLUTOSURFACE1X1PLS15WLED857S or eqivalent to phillips/Bajaj.
Supply and fixing TP&N distribution board with double door vertical type TPN DB made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating,suitable for MCCB for capacity 100Amp, 16 KA, Incomer 4 ways 415 Volts made up of CRCA sheet with busbar rating 200 Amps Adjustable thermal (70% to 100%) & Fixed magnetic setting type including grouting in the wall, cutting & chasing etccomplete all as specified Cat par No.DHDPTVODRW04 opf Havells or equivalent to L&T/ABB
"SEWAGE DISPOSAL AND FENCING AND GATE"
M&L for walling of Porbandar stone masonry well bonded and solidly hearted built in CM 1:6 complete all as specified and as directed.
"EXTERNAL WATER SUPPLY"
Supply and laying in trenches/fixing on wall UPVC pipes (SCH-40) of size 25mm bore complete all as specified and directed.
S & F Ball valves suitable for UPVC sch 40 pipes of size 25 mm bore complete all as specified and directed.
Supply, Installation & testing of Submersible pump, electric driven 415 V, Three Phase system complete upto 5 HP - 01 No (inclusive of submersible cable and auto star delta starter) complete all as specified & all as directed by Engr-in-Charge
Supply and fixing of rotational molded polyethylene HDPE water storage tanks (cylindrical vertical with closed top) of 10000 Ltr capacity, ISI marked double layered complete with inlet, outlet wash out and overflow nipples and connections incl top lid complete all as specified & as directed
M& L for cement concrete in foundations filling and mass concrete type B-2 1:2:4 for foundation for PVC tank complete all as specified & as directed
M&L for water reducing admixture for concrete at the rate of 150mg per bag of cement all as specified & directed by Engineer -In-Charge
M&L for applying two coats of polymer modified cementatious based slurry be applied over the rendered smooth surface of outer wall including vertical surface of base slab at the rate of 200gms/sqm all as specified & directed by Engineer -In-Charge
"EXTERNAL ELECTRIC SUPPLY"
Supply, fixing, commissioning and testing LT Panel Board (Make shall be CPRI Approved) indoor type double door, both side openable type prewired with adequate size copper conductor/copper strip made out of 3.6mm CRCA sheet and angel iron frame of size 40x40x6mm includig necessary PCC foundation duly powder coated and withminimum seven tank process with provision of brass glands at the bottom of pannel for inserting of LT cable comprising the following :- (a) Copper bus bar of 200Amps - 04 Nos duly covered with Red, Yellow, Blue and black PVC seve/tape and fixed on DMC insulators. (b) S&F MCCB FP 100 Amp,415 Volt, 35 KA thermal adjustable type. (Incomming) - 01 Nos. (c) S&F MCCB FP 63 Amp, 415 Volt, 25 KA. (Out going) -01Nos. (RO Plant) (d) S&F MCB TPN 32 Amp,25 KA (Out going) - 04Nos.( Pump se-+ Borewell+ 1 Spare) (e) S&F MCB SPN 32 Amp,10 KA 'C' series. (Out going) - 01Nos ( RO Plant Room) (f) S&F multifunctional type digital meter to measure voltage, current, frequency, PF etc complete - 01 Nos (g) Indicator lamp (R Y B) - 01 Set (h) DOL starter of capacity 5/7.5 HP - 02 Nos (j) Digital Voltmeter - 01 Nos (k) Digital Ammeter - 05 Nos
RO PLANT Design, supply, installation, testing and commissioning of RO plant of capacity 28000 Ltrs per day (4000Ltrs/Hr) complete including the following so as to obtain treated water in accordance with IS:10500. Make : M/s Thermax Limited, M/s Optimus Enviropro Pvt Ltd, M/s Bharti Waters Pvt Ltd (a) Lime/Dolomite dosing pump as per specifications given below:- i) Size : 1000 LPH@ 15 MWC ii) Material of construction : CI iii) Pump power : 0.75 KW iv) Type : Horizontal centrifugal v) Make : Johnson/Kirloskar/Grundfoss vi) Qty : 02 No (b) Lime/Dolomite dosing tank with agitator as per specifications given below:- i) Size : 1000 Ltr ii) Material of construction : MS iii) Material of construction agitator: Mild steel epoxy painted iv) Agitator motor rating : 1.1 KW v) Make : Thermax/Approved vi) Qty : 01 No
(c) Alum/FeCI3 dosing pump as per specifications given below:- i) Size : 30 [email protected] Kg/Cm2 ii) Material of construction : Poly propylene iii) Pump power : 0.37 KW iv) Make : Milton Roy/Prominent/Grundfoss v) Type : Diaphragm vi) Qty : 02 No (d) Alum/FeCI3 dosing tank with agitator as per specifications given below:- i) Size : 300 LTRS ii) Material of construction (Tank) : MSRL iii) Material of construction agitator : MSRL iv) Agitator motor rating : 0.55 KW v) Make : Thermax/Sintex/Astral (e) PE dosing pump as per specifications given below:- i) Size : 30 [email protected] KG/CM2 ii) Material of construction : Poly propylene iii) Pump power : 0.37 KW iv) Make : Milton Roy/Grundfoss/Prominent v) Type : Diaphragm vi) Qty : 02 No
(f) PE dosing tank with agitator as per specifications given below:- i) Size : 300 LTRS ii) Material of construction (Tank) : MSRL iii) Material of construction agitator : MSRL iv) Agitator motor rating : 0.55 KW v) Make : Thermax/Sintex/Astral vi) Qty : 1 No (g) Level gauge as per specifications given below:- i) Type : Glass gauge ii) Qty : 2 No iii) Make : S.P. Enterprises or As per OEM (h) Level gauge for lime dosing tank as per specifications given below:- i) Type : Glass gauge ii) Qty : 2 No iii) Make: S.P. Enterprises (j) Level switch as per specifications given below:- i) Setpoints : 02 (L & H) ii) Qty : 02 No iii) Make : As per OEM Pune techtrol/Astor/E & H
(k) Starter panel for dosing pump & flocculator as per specifications given below:- i) Qty : 1 No ii) Make : Thermax approved/As per OEM (l) Control & Power cabling as per specifications given below:- i) Qty : 01 Lot ii) Size : 04/06 sqmm, 4 core, 1100 v grade, LT copper cable,PVC insulated, armoured iii) Make : Polycab/Finolex/Havells/CCI (m) Level switch for lime dosing tank as per specifications given below:- i) Setpoints : 2 (L & H) ii) Qty : 01 No iii) Make : Pune techtrol/Aster/E & H (n) DMF feed pump as per specifications given below:- i) Size : 11.3 M3/HR@100 Microns ii) Material of construction : SS316 iii) Make : Kirloskar/Grundfoss/Johnson iv) Qty : 01 No (v) Capacity of DMF Pump: As per OEM Design
(o) Dual media filter as per specifications given below:- i) Size : As per OEM ii) Material of construction : Mild Steel epoxy painted iii) Qty : 01 No (iv) Make: As per OEM (p) Iron removal filter as per specifications given below:- i) Size : As per OEM ii) Material of construction : MSEP iii) Qty : 01 No iv) Make : As per OEM (q) Basket strainer as per specifications given below:- i) Size : 11.3 M3/HR@100 Microns ii) Material of construction : SS316 iii) Qty : 01 No iv) Make : As per OEM (r) UF membranes as per specifications given below:- i) Size : 8” X 60” – 10KD ii) Material of construction : PES/PVDF iii) Qty : As per OEM design iv) Make: Dupont/Hitech/Veolia
(s) HYPO/NaOH dosing pump as per specifications given below:- i) Size : 100.0 LPH @ 3.0 KG/CM2 ii) Material of construction : Poly propylene iii) Qty : 01 No iv) Power : 0.37 KW v) Type : Diaphragm vi) Make : Milton Roy/Prominent/Groundfoss (t) HYPO/NaOH dosing tank as per specifications given below:- i) Size : 100 Ltrs ii) Material of construction : LLDPE iii) Qty : 01 No iv) Make : Thermax/Sintex/Astral (u) HCL dosing pump as per specifications given below:- i) Size : 50.0 LPH @ 3.0 KG/CM3 ii) Material of construction : Poly propylene iii) Power : 0.37 KW iv) Type : Diaphragm v) Make : Milton Roy/Prominent/Grundfoss vi) Qty : 01 No
(v) HCL dosing tank as per specifications given below:- i) Size : 100 Ltrs ii) Material of construction : LLDPE iii) Qty : 01 No iv) Make : Thermax/Sintex/Astral (w) UF backwash pump as per specifications given below:- i) Size : 24.0 m3/HR @ 2.5 Kg/cm2 ii) Material of construction : CI iii) Qty : 1 No iv) Power : 3.7 KW v) Type : Horizontal centrifugal vi) Make : Kirloskar/Grundfoss/Johnson (x) Internal water supply work as per specifications given below:- i) Qty : 1 Lot ii) Material of construction : UPVC iii) Make : Thermax/Astral/Finolex (y) Pressure indicator as per specifications given below:- i) Range : 0-7 Kg/cm2 g ii) Qty : 3 Nos iii) Make Micro/Pointeer/Thermax/H-Guru (A) Level Switch: - (i) Qty: - 01 (ii) Set Points: - 3 (L, M & H) (iii) Make: - Aster/E&H/Pune Techtrol (B) Flow Totaliser :- (i) Qty: - 01 (ii) Make: - Aster/E&H/Pune Techtrol (C) Pressure Switch: - (i) Qty: - 01 (ii) Capacity: - 0 – 7 Kg/Cm2g (iii) Make: - Orion/Danfoss
(z) Logic controller as per specifications given below:- i) Qty : 1 No ii) Type : Microprocessor based iii) Thermax/WABAG/Proj (aa) Instrumentation cum starter panel as per specifications given below:- i) Make : As per OEM ii) Qty : 01 No (ab) Instrumentation power & control cabling as per specifications given below:- i) Make : As per OEM ii) Type of cabling : 4 core, 1100 V, PVC insulated armoured copper cable iii) Qty : 01 No (ac) Acid dosing pump as per specifications given below:- i) Capacity : 0-6 LPH @ 3.5 Kg/CM2g ii) Material of construction : Poly propylene iii) Power : 0.03 KW iv) Type : Electronic metering type v) Make : Thermax/Grundfoss/Milton roy vi) Qty : 01 No
(ad) Acid dosing tank with level switch as per specifications given below:- i) Capacity : 80 Ltrs ii) Material of construction : LLDPE iii) Make : Sintex/Astral/Thermax iv) Qty : 01 No (ae) Antiscalent dosing pump as per specifications given below:- i) Capacity : 0-6 LPH @ 3.5 KG/CM2g ii) Material of construction : Poly propylene iii) Power : 0.03 KW (iv) Type : Electronic metering type (v) Make : Thermax/Sintex/Astral vi) Qty : 01 No (af) Antiscalent dosing tank with level switch as per specifications given below:- i) Capacity : 80 Ltrs ii) Material of construction : LLDPE iii) Make : Thermax/Sintex/Astral iv) Qty : 01 No
(ag) Cartridge filter as per specifications given below:- i) Size : As per OEM ii) Material of construction (Cartridge) : Poly propylene iii) Material of construction (Housing) : SS iv) Qty : 01 No v) Make : Thermax or equivalent (ah) High pressure pump as per specifications given below:- i) Capacity : 7.8 m3/hr ii) Material of construction : SS316 iii) Type : Centrifugal pump iv) Make : Grundfoss/Willo/Eylua v) Qty : 01 (aj) Pressure tubes as per specifications given below:- i) Size : As per OEM ii) Material of construction : FRP iii) Make : Thermax/Pointer (iv) Qty : 02 No
(ak) Membranes as per specification given bellow:- i) Size : 8” DIA ii) Material of construction : Poly propylene iii) Make : DOW/Veolia/Hydronautics (al) PH dosing pump as per specifications given below:- i) Capacity : 0-6 LPH @ 3.5 KG/CM2g ii) Material of construction : Poly propylene iii) Power : 0.03 KW iv) Type : Electronic metering v) Make : Thermax/Grundfoss/Milton roy vi) Qty : 01 No (am) PH dosing tank with level switch as per specifications given below:- i) Capacity: 80 Ltr ii) Material of construction : LLDPE iii) Make : Thermax/Sintex/Astral iv) Qty : 01 No
(an) Internal water pipe (Low pressure) as per specifications given below:- i) Material of construction : UPVC ii) Size : As per OEM iii) Make : Astral/Finolex iv) Qty : 01 lot (A) Internal Water Piping (High pressure) :- (i) Material of construction: - SS316 (ii) Size: - As per OEM (iii) Make: - As per OEM (iv) Qty: - 01 Lot (ao) Pressure indicator (Direct) as per specifications given below:- i) Range : 0-7 Kg/cm2 g & 0-24 Kg/cm2 g ii) Make : Micro/Thermax/Pointer iii) Qty : 03 No (ap) Pressure switch (Low) as per specifications given below:- i) Range : 0.1 to 1Kg/cm2 g ii) Make : Orion/Danfoss/6 & 11 iii) Qty : 01 No (aq) Flow indicator as per specifications given below:- i) Make : Astral/Euroka/Forbes Marshallii) ii) Qty : 03 No
(ar) Level switch as per specifications given below:- i) Setpoints : 03(L, M & H) ii) Make : Astral/Thermax iii) Qty : 01 No (as) Oxidation reduction potential analyzer as per specifications given below:- i) Range : (-)1900 mv to (+)1900 mv ii) Make : Astral/G & H/Forbes Marshasll iii) Qty : 01 No (at) Conductivity meter as per specifications given below:- i) Range : 0-500 µsiemens/cm ii) Qty : 01 No iii) Make : Astral/G & H/Forbes Marshall (au) Silt density index as per specifications given below:- i) Make : Astral/G & H/Forbes Marshall ii) Qty : 01 No
(av) Logic controller as per specifications given below:- i) Type : Microprocessor Based ii) Make : Thermax/As per OEM iii) Qty : 01 No (aw) Instrument cum starter panel i) Make : Thermax/As per OEM ii) Qty : 01 No (ax) Instrument and power cabling i) Qty : 01 Lot ii) Material of construction : 4 core, 1100 V, PVC insulated (cable) armoured copper cable iii) Make : As per OEM iv) Material of construction : CRCA sheet (Housing)
Notes for item No. 15.00:- (i) The tenderer/ Contractor shall carryout testing of RAW water from a NABL accredited Lab and based on the report shall design the RO Plant. Design details shall be submitted to Engineer-in-Charge for approval within 60 days of acceptance of tender. (ii) All work of RO Plant Machinery shall be carried out by OEM only and MoU to this effect to be submitted within 30 days from the date of commencement of work. (iii) The Contractor shall submitted flow chart/ flow diagram for working system of RO Plant before commencement of the work to Engineer –in- Charge. (iv) All civil works required for RO Plant i.e. Foundations, earthwork, PCC work are deemed to be included in the unit rate quoted. (v) After installation/ completion of work, contractor shall carryout testing of treated water from a accredited NABL Lab and submit report. Payment of the RO plant shall be allowed after successful testing & commissioning of the RO plant. (vi) The contractor is required to carry out test of treated water on monthly basis from NABL lab to ascertain suitability of drinking water as per IS- 10500 up to Defect Liability Period. Rate for the same is deemed to be included in the unit rate quoted. (vii) Any spare parts / consumables required for running of RO Plant within defect liability period shall be arrange by contractor without any cost to department.
Manning and operation of RO plant installed at 7M Det Okha by deploying one qualified & skilled electrician in one shift of 08 hours each (i.e. 09:00 AM to 05:00 PM including sunday and holidays complete all as specified and directed by Engineer-in-Charge comprising of following for proper maintenance of RO plant:- 1) LT Panel, RO PLANT with connecting accessories, for 11 Months after the completion of RO Plant work. INTER CONNECTING PIPING (a) From raw water sump to raw water pump -01 No 80mm size PVC material (b) From raw water pump upto High pressure pump -01 No 80mm Size, PVC material (c) From High pressure pump to RO Section -01 No 50mm size ss Material (d) All dosing pump suction and delivery line -01 LOT, 6-8MM size, PVC matrerial (e) From RO plant outlet upto treated wtare sump- 01 No, 50mm size, PVC material (f) From RO plant reject upto Deep Bore well -01 No 50mm size PVC material ELECTRIC WIRING - All electric wiring by single core/3 core copper conductor MOTOR CONTROL CENTRE (i) MCCB Cap 100 Amp, 4 pole - 01 No ii) Automatic 3 phase sequence corrector cum single phasing contactor with auto start - 01 No (iii) MCB TP 16 Amps - 01 No (iv) MCB TP 63 Amps -01 No v) MCB DP 02 Amps -04 Nos vi) MCB SP 06 Amps - 06 Nos (vii) MCB SP 02 Amps- 01 No (viii) Relay contactor - 02 Nos (ix) 5 MPS - 01 No (x) Hooter - 01 No (xi) AB Contactor 3 TF 30 Amp - 05 No (xii) AB Contactor 3 TF 3400-0 A -02 Nos
Manning and operation of RO plant installed at 7M Det Okha by deploying one qualified & skilled electrician in one shift of 08 hours each (i.e. 09:00 AM to 05:00 PM including sunday and holidays complete all as specified and directed by Engineer-in-Charge comprising of following for proper maintenance of RO plant, 1) LT Panel, RO PLANT with connecting accessories, for 11 Months after completion of Item No. 16. INTER CONNECTING PIPING (a) From raw water sump to raw water pump -01 No 80mm size PVC material (b) From raw water pump upto High pressure pump -01 No 80mm Size, PVC material (c) From High pressure pump to RO Section -01 No 50mm size ss Material (d) All dosing pump suction and delivery line -01 LOT, 6-8MM size, PVC matrerial (e) From RO plant outlet upto treated wtare sump- 01 No, 50mm size, PVC material (f) From RO plant reject upto Deep Bore well -01 No 50mm size PVC material ELECTRIC WIRING - All electric wiring by single core/3 core copper conductor MOTOR CONTROL CENTRE (i) MCCB Cap 100 Amp, 4 pole - 01 No ii) Automatic 3 phase sequence corrector cum single phasing contactor with auto start - 01 No (iii) MCB TP 16 Amps - 01 No (iv) MCB TP 63 Amps -01 No v) MCB DP 02 Amps -04 Nos vi) MCB SP 06 Amps - 06 Nos (vii) MCB SP 02 Amps- 01 No (viii) Relay contactor - 02 Nos (ix) 5 MPS - 01 No (x) Hooter - 01 No (xi) AB Contactor 3 TF 30 Amp - 05 No (xii) AB Contactor 3 TF 3400-0 A -02 Nos
Notes for item No. 16 & 17 1. The quoted rate shall be deemed to include following items :- (a) Repairs/replacement of any of the components of RO plant, control panel, electrical wiring etc. (b) Servicing of pump sets, rewinding of motors, doisers pumps washing & top up of sand gravel media, cleaning/replacing activated carbon, cleaning of feeder water sumps as required to avoid increased conteplation in raw water. (c) Supply and filling of RO water treatment chemicals to achieve water quality confirming to IS 150500 2. (i) All operators shall be ITI qualified and necessary certificate shall be produced to Engr-in-Charge for varification before employing as operator. (ii) Operator will also Assist MES Departmental employees such as electrician/FGM deployed to carryout maintenance work at Naval Base area as directed at site without any extra cost to department. (iii) All installation shall be kept neat and clean and all necessary documents shall be available upto date and available at installation. (iv) No unauthorised entry of personals other than operator on duty shall be allowed to enter in the installation unless otherwise instructed by the Engr-in-Charge. (v) If the contractor is found non maintaining of log sheets, Rs. 20/- per shift for non maintaining of log sheet shall be deducted from the account due to contractor. (vi) The operator employed shall be well versed with operation of RO plants and to be capable to attend and repair minor defects of RO plants and LT panels, replacement of fuses etc. (vii) All tools, measuring instruments required for maintenance of RO plant and panel shall be available at installation safety equipment required for smooth operation of electrical installation and operator as per IS shall be ensured by the contractor for safety of operator and any electric accident occured due to non adherence of safety measures or lakh of knowledge of operator shall be entirely rest with contractor. 3. A penality of double of the quoted rate shall be levied any failure of plant being of basic necessity services to human.
JAY BHARAT METAL SUPPLIERS (BID ID -3071240)
Harsh Infrastructure (BID ID -3067233)
VIVEK JITENDRABHAI KATAR (BID ID -3071306)
M/S. P.M GODHANIYA (BID ID -3069723)
AUM STRUCT BUILD PVT LTD (BID ID -3068541)
K B N TRADERS (BID ID -3071118)
OM ENTERPRISE (BID ID -3070232)
SURESH ELECTRICALS (BID ID -3070469)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .