| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC 39 359 B PULICKAL THIRUVAMBADY POST ALAPPUZHA KERALA PIN 688 002 | ALAPPUZHA | ALAPPUZHA | KERALA | 688002 | L1 | Accepted-AOC lowest tender | |
| 2 | L2₹16.7 L+₹97,714 (6.20%)Rejected-Finance MUKALATH VALAYANCHIRANGARA PO PERUMBAVOOR ERNAKULAM KOCHI 683556 | PERUMBAVOOR | ERNAKULAM | KERALA | 683556 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹16.9 L+₹1.1 L (7.03%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
15 Sept 2021, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services, Garrison Engineer (Naval Services), Kataribagh, Naval Base Post, Kochi, 682 004.
UPKEEP OF E/M INSTALLATION AND CONNECTED SERVICES LIKE TRANSFORMER, VCB ETC AT NAD ALWAYE UNDER AGE ALWAYE
2021_MES_468494_1
8822/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
ALWAYE
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹36,000
Yes
29 Oct 2021
17 Aug 2021
17 Sept 2021
17 Aug 2021
15 Sept 2021
31 Aug 2021
17 Aug 2021 - 30 Aug 2021
Amount
Excavation in trenches in Soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5m in depth for laying pipes, cables etc and getting out as specified.
Excavation in trenches in Soft/loose soil not exceeding 1.5 m wide but exceeding 1.50 meter in depth complete all as specified and as directed by the Engineer-in-Charge.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick all as specified.
Removing surplus excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point.
Supply and spreading River sand Dry cushioning to cable providing with a layer of sand 8cm deep before laying the cable and 15cm deep after laying and stretching the cable in trenches complete all as specified and as directed by the Engineer-in-Charge.
Supply & Laying unreinforced precast concrete cable cover ,class HV type 1 ,flat size 300 mmx180mmx40 mm with peak of 65 mm complete confirming to IS -5820 OF 1970 for protection of cable complete all as specified and directed.
Supply & lay un reinforced pre cast concrete cable cover class LV type 1 flat size 250mmx150mmx40mm for protection of cable complete all as specified and directed.
Supply, laying, jointing, testing & commissioning in pipes/ducts/trenches/under floor/under road HT XLPE cable insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (Heavy duty) with aluminium stranded conductor 11 KV 'Earthed' grade confirming to IS 7098 (Part II) of 1985 cross sectional area 185 Sqmm 3 core complete all as specified and directed.
Supply, laying for replacement of unserviceable underground LT cable 1100 Volts grade heavy duty electric cable XLPE outer sheathing with aluminium conductor, Armoured confirming to IS-7098 Part-I (1988) with latest amendments of size 300 Sqmm x 3.5 core including taking out old unserviceable cable complete all as specified and directed.
Ditto as per item No 9 above but of LT Cable 10 sqmm x 4 core.
Material & Labour for Cement concrete 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate for erection of pole, repair of road cuttings etc all as specified and directed by Engineer-in-Charge.
Material and labour for cable jointing kit (end termination) Indoor type, heat shrinkable type including all jointing material & accessories suitable for 11KV Cable aluminium conductor cables of size 120 to 185 Sqmm 3 core cables Including dismantling old one complete all as specified and directed.
Material and labour for cable jointing kit (end termination) outdoor type, heat shrinkable type including all jointing material & accessories suitable for 11KV Cable aluminium conductor cables of size 120 to 185 Sqmm 3 core complete all as specified and directed.
Supply & laying in replacement Galvanised steel tubing of size 100 mm bore, light grade to be fixed on walls or laid under roads for passing cables complete as specified and as directed.
Ditto as per item No 15 above but of size 40 mm bore.
Material & Labour for Earthing for transformer body, transformer neutral, LT feeder pillar box etc with copper earth plate of size 600 x 600 x 3.15 mm thick buried directly in ground not less than 2.25 metre below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150 mm in layers, connected by copper earth strip of size 20 x 3 mm thick, soldered and riveted to earth plate. Copper earth strip will be protected by using 40mm bore GI pipe (light grade) earth plate to transformer body, LT feeder pillar box, and neutral of transformer etc complete. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20 mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 metre etc complete all as specified and shown in electrical plate No 3 of SSR Part I - 2009. Note: - Main earthing lead from earth plate to test point & up to 7.5 Metre to be provided. The cost for the same shall be deemed to be included in the above quoted rate.
Material & Labour in repair for gang operated triple pole mechanically operated air break on load disconnecting switch each pole consist of galvanised steel base HT 11KV insulators per phase non ferrous knife and spring loaded contact. GI pipe of adequate length for operation from ground level and operating handle complete in both OFF and ON position capacity 11 KVA 200 Amps including dismantling old unserviceable complete all as specified and as directed.
Supply and laying synthetic Rubber insulated mats 2.5 mm thick for voltage 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed
Supply and lay electrical LT insulation rubber matting as per ISI of size 2m x 1m x 10 mm thick complete all as specified and as directed
Supply and erect Pre-stressed concrete pole 9.0 metres long, 102mm x 172mm at top and 102mm x 279mm at bottom, class 10 confirming to IS 785 (1964) including painting and dismantling old one complete all as directed by Engineer -in -Charge
Supply and Fix steel tubular swaged poles complete with cast iron base plate, final taper plug ,bolts, nuts and screws as specified type 410 SP -31, 9.0 metre long including painting of poles with aluminium enameled paint one coat over a coat of red oxide primer and including two coat of black bituminous paint on embedded portion of pole including dismantling old one complete all as specified and as directed by the Engineer-in-charge (Excavation, earth work and PCC shall be measured and paid for separately)
Ditto all as per item No 22 but for type 410 SP -55,11 metre long.
Supply & Fix lightening arrestor HT 11KV pole mounting metal oxide type complete with all fittings transmission class nominal discharge current 65 KA including removing the defective one complete all as directed by Engineer in charge.
Material & Labour for preparation of old painted surface of Transformer 100 KVA to 500 KVA by removing all dirt, dust, grease, oil etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour including writing of identification Nos, capacity etc all as directed by Engineer-in-Charge.
Material & Labour for preparation of old painted surface of LT/HT steel tubular electric pole (Top to bottom from ground level) by removing all dirt, dusted and painting complete surface including connected accessories such as angle Iron channel of distribution lines, for three phases and street light phases of any description with one coat of aluminium paint of approved colour including writing of identification Nos,30cm strips of alternative layers upto 1.5 metre from ground level with synthetic enamel paint of black and yellow colour etc all as directed by Engineer-in-Charge.
All as per serial item No 26 above here in before but of 9 metre height concrete pole with one coat of Cement based white paint.
Material & Labour for preparation of old painted surface of Feeder Pillar box/LT Cubical panel boards by removing all dirt, dust, etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour including writing of identification etc all as directed by Engineer-in-Charge
Material & Labour for cross arm bracing support to clamps and back plate fabricated from structural steel section like angles channels flat etc including nuts bolts and washers welding bending cold or hot drilling holes for bolts if any shape and size and including applying two coats of aluminium paint over one coat of red oxide primer including dismantling old one and all as directed by Engineer-in-charge.
Supply and applying petroleum jelly on moving parts of GOD after removing carbon, dust etc complete all as specified and directed by Engineer-in charge
Material and Labour for installation sign/display board flat boards type outdoor complete mounted on 20mm size MS square tubing 6mm thick marine plywood including flat iron clamps & angle iron support for grouting /fixing on walls complete including computer printing/inject printing of words/diagram/emblems etc all as directed by Engineer-in-Charge Note:- The matter in each case depending on the installation will be as given and finalized by the Engineer-in-charge. The rate quoted is deemed to include the same.
Material and Labour for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for LT, 20x15cm size.
Ditto as per item No 32 above but for HT, 25x20 cm size.
Material and Labour hard core of gauge not exceeding 63mm deposited spread and leveled in layers n.exc 15cm thick, watered and rammed to true surface broken stone or boulders or aggregate around 4 pole , 2 pole structure and transformer etc. as per directed by Engineer-in-charge.
Material and Labour for servicing of HT VCBs, 11 KV 400/630 Amp capacity, indoor type by drawing out breaker assay from panel, cleaning/decarbonizing the contact points by suitable means, applying petroleum jelly, lubrication, adjust the trolley in and out mechanism and moving parts, testing of all tripping system and device, internal wiring circuit etc, tightening of all connections, replacement of HRC fuse (if any found unserviceable ) engage the VCB with the supply system and testing for smooth function complete all as directed.
Material and Labour for calibration of protective relays both 02 Nos over current and 01 No earth fault relay of IDMT or any other type by using relay injection kit and re-set timing and tripping current according to the connected load all as directed.
Supply & fix Gear Assembly for VCB.
Supply & fix Limit Switch for Gear Motor for VCB.
Supply & fix Spring Charge Gear Motor for VCB.
Supply & fix Shunt Coil for Tripping and closing 110V DC.
Supply & fix LED Indication Lamp 110V DC.
Supply & fix Spout assembly without contact point.
Supply & fix PLA Relay 110V DC.
Supply & fix Bridge Type Diode 25A.
Supply & fix 11KV, PT Fuse 2 A.
Supply & fix Cast resin type Potential Transformer Suitable for indoor VCB 11KV/√3/110/√3, A.C of Burden 100VA.
Supply & fix Auxiliary switch NO/NC.
Supply and replacing breather assembly of transformer with new silica gel suitable for any make of transformer of capacity 100 KVA to 400 KVA complete as specified.
Supply and replace brass terminal stud with nuts, check nut, oil seal and washer for HT side of transformer of any make as per sample for 100 to 400 KVA transformers complete as specified.
Supply and replace brass terminal stud with nuts, check nut, oil seal and washer for LT side of transformer of any make as per sample for 100 to 400 KVA transformers complete as specified.
Comprehensive maintenance to APFC Panel indoor/outdoor including replacement of burnt out bakelite fuse of suitable size or capacitors of various sizes 5/10/20 KVAR and MCBs of any sizes as specified and directed.Note: - All accessories required to be replaced will be measured and paid separately as supply only.
Supply only power capacitor (MPP) in existing capacitor bank of capacity 5 KVAR as specified.
Supply only power capacitor (MPP) in existing capacitor bank of capacity 10 KVAR as specified.
Material and labour for filtration of insulating oil of transformer, voltage stabilizer’s etc in situation to bring the brake down value of oil not less than 40 KV at 2.5 mm gap all as specified and directed by Engineer-in-Charge including topping up of oil upto required level at different location.
Material and labour for draining out old transformer oil from Transformer/voltage stabilizer and refilling of new transformer oil of BDV 60 KV dielectric strength when tested between 2.5mm gap electrical
Dismantling and removing existing automatic voltage stabilizer for automatic operation air cooled servo controlled type input voltage 260 – 440 V & output voltage 420 V capacity upto 63 KVA opening re fixing and reinstallation. Note: - Replacement repair of parts if any found damaged during repair shall be measured and paid for separately.
Dismantling and replacement of dimmer coil with suitable gauge to make up existing stabilizer of capacity 63 KVA.
Material and labour for replacement of electronic circuit plate complete with DC transformers lete (PCB cold) upto 63 KVA
Replacement of servo motor with carbon brush holder etc upto 63 KVA complete including dismantling old one.
Supply and install test and commissioning of factory made outdoor type floor mounted LT cubical panel board 415 volts, 3 phase 4 wire, 50 Hz AC supply, dust and vermin proof IP-54 Protection CPRI Approved having suitable size made out on 3.15 mm CRCA steel sheet powder coated as per IEC 61439 with aluminium bus bar of 300 Amps for phases and 200 Amps for Neutral duly laminated with colour coding sleeves. Mounted on MS angle iron frame of size 40x40x4mm grouted in PCC type B2 above ground level including dismantling old existing panel board. The Panel board shall comprise with the following controls. :-( Note- MCCB,MCB, Meters, Indicating lamps etc shall be included in the quoted rates ) (A) INCOMING:- (a) MCCB 125 Amps, 4 pole, 415 Volts, 25 KA breaking capacity with adjustable thermal magnetic release setting - 1 No (b) Digital type volt meter (0 to 500 Volts) 96 x 96 mm - 01 No (c) Digital type Ammeter (0 to 200 Amps) 96 x 96 mm - 01 No (d) Indicator lamp (set of 3) -01set (B) OUTGOING:- (a) MCCB 40 Amps, 4 pole, 415 Volts, 25KA breaking capacity with adjustable thermal magnetic release setting -3 Nos (b) MCB 32 Amps, TPN, 415 Volts, 10KA breaking capacity -2 Nos
Disconnecting electrical connections of Transformer 300 KVA (01 No) and shifting it from VCB Room to DG Room within 30 metre at power house at NAD Alwaye. Fixing transformer making all connections and testing after installation complete and making good the disturbed surface as per existing. (Note: Rates for transportation/Crane / labour shall be deemed to be included in the item quoted rate).
Disconnecting electrical connections of Transformer upto 250 KVA (01 No) and T-Panel (01 No) shifting it from DG Room to AGE B/R Store yard (Within 01 KM) at NAD Alwaye and making good the disturbed surface as per existing. (Note: (a) Plant shall be kept/ stored as directed by engineer in charge within one KM and rates for transportation/Crane / labour shall be deemed to be included in the item quoted rate).
Material & Labour for drilling suitable dia horizontal bore holes for insertion/ laying of 80/100mm /150mm bore GI/DI/CPVC Tubing of any description below/under existing road surfaces / floors at a level not less than 0.60 metre etc with using mechanical / or manual devices as required at site including making good the disturbed surfaces to match with the existing after laying pipes complete all as specified and directed by Engineer-in-Charge. Note: (i) Cost of equipment tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor at no extra cost to the department.
Supply & Fix in repair On load change over switch 400A, 4 pole, 415 Volts, 50 Hz.
Supply & Fix in repair On load change over switch 100A, 4 pole, 415 Volts, 50 Hz.
Supply & Fix maintenance free battery 12v, 42Ah including connection with UPS of VCB
Supply & Fix in repair 1000 VA, UPS backup suitable for VCB 11kv,
Supply & Fix in repair MCCB 415V, 50 HZ, 630 Amps, 4 pole of breaking capacity 36 KA, with adjustable thermal magnetic release setting
Supply & Fix in repair MCCB 415V, 50 HZ, 400 Amps 4 pole of breaking capacity 35 KA with adjustable thermal magnetic release setting
Supply & Fix in repair MCCB 415V 3 phase 50 HZ, 250 Amps 3 pole of breaking capacity 35 KA with adjustable thermal magnetic release setting.
Supply & Fix in repair MCCB 415V 3 phase 50 HZ, 250 Amps 4 pole of breaking capacity 35 KA with adjustable thermal magnetic release setting.
Supply & Fix in repair MCCB 415V, 50 HZ, 3 pole, 63 Amps breaking capacity 25 KA with adjustable thermal magnetic release setting.
Supply & Fix in repair MCCB 415V, 50 HZ, 200 Amps 4 pole of breaking capacity 35 KA with adjustable thermal magnetic release setting
Supply & Fix in repair MCCB 415V 4 phase 50 HZ 4 pole 63 Amps breaking capacity 25 KA with adjustable thermal magnetic release setting.
Supply & Fix in repair MCCB 415V, 50 HZ, 160 Amps 4 pole of breaking capacity 25 KA with adjustable thermal magnetic release setting.
Supply & Fix in repair MCCB 415V, 50 HZ, 100 Amps 4 pole of breaking capacity 25 KA with adjustable thermal magnetic release setting.
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
Kuriako Mathai and company
Palakkal Agencies
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .