Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC THIRIYA NIZAWAT KHAN JAMAMASZID WARD NO 07 BAREILLY 2430021 UP | BAREILLY | UTTAR PRADESH | 243002 | ₹18.8 L Quoted ₹20.6 L | L1 | Accepted-AOC Over all rates are reasonable and lowest. |
| 2 | L2₹21.5 L+₹86,700 (4.21%)Rejected-Finance WARD NO 11 THIRIYA NIZAWAT KHAN BAREILLY | BAREILLY | BAREILLY | ₹21.5 L+₹86,700 (4.21%) | L2 | Rejected-Finance Over all rates are higher than L-1. |
| 3 | L3₹21.8 L+₹1.2 L (5.94%)Rejected-Finance | ₹21.8 L+₹1.2 L (5.94%) | L3 | Rejected-Finance Over all rates are higher than L-1. |
| 4 | L4₹23.7 L+₹3.1 L (14.9%)Rejected-Finance MOH HATHITHAN NIGOHI ROAD SHAHJANPUR UP 242001 | SHAHJAHANPUR | UTTAR PRADESH | 242001 | ₹23.7 L+₹3.1 L (14.9%) | L4 | Rejected-Finance Over all rates are higher than L-1. |
| 5 | L5₹24.9 L+₹4.3 L (21.0%)Rejected-Finance | ₹24.9 L+₹4.3 L (21.0%) | L5 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
31 May 2023, 6:00 pmClosed
GE WEST BAREILLY
GE WEST BAREILLY
REPAIR/ REPLACEMENT OF CEILING FAN AND EXHAUST FAN AND INTERNAL ELECTRIC AND OTHER CONNECTED WORK OF OTM/MD ACCN OF BAREILLY CANTT UNDER GE (W) BAREILLY.
2023_MES_591809_1
8103/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE WEST BAREILLY
₹68,000
Yes
17 Jun 2023
27 Apr 2023
2 Jun 2023
27 Apr 2023
31 May 2023
11 May 2023
Amount
Taking down ceiling fans 1200/1400 mm sweep & removing/cleaning of dust properly, oiling and greasing of bearing including re-fixing and connecting up with all requisite accessories complete all as specified and directed.
Re-winding of ceiling fan burnt motor of 1200/1400 mm sweep including internally and externally cleaning of fans and removing the burnt coil and re-winding of fans by super enameled copper wire of appropriate size and re-assembling the fans and connecting with flexible copper wire of one mtr length and testing after repair complete all as specified and directed.
Taking down exhaust fan of 450/300 mm sweep and removing/cleaning the dust properly including oiling and greasing complete all specified and as directed.
Re-winding of exhaust fan burnt motor of 450/300 mm sweep with appropriate size of super enameled copper wire, Make: ATLAS or equivalent including re-assembling the fans and connecting with flexible copper wire of one mtr length complete all as specified and directed.
Supply and Fixing in repairs bush of ceiling fans of any size complete all as specified and directed.
Supply and Fixing in repairs insulating rubber real including Supply and replacing nuts, bolts with washers complete all as specified and directed
Supply and Fixing in repairs shaft of fans (as per sample) of suitable size complete all as specified and directed
Supply and Fixing in repairs of fan pins of suitable size for various type of fans / ceiling fans complete all as specified and directed.
Supply and Fixing in repairs flexible wire 23/0.0076 PVC insulated copper conductor twin core complete all as specified and directed. Make- Havells/ Anchor/ Finolex/Kalinga
Supply and Fixing in repairs fan conopy, suitable for various type ceiling fan all as per sample complete all as specified and directed.
Supply and fixing PVC exhaust fan 300 mm with louvers with complete fixing and making electric connection complete all as specified and directed.
Supply and fixing PVC Wall mounting fan of 400 mm size with ocsilating mechanism, motor and all all fittings and connection all as directed and specified by Engr-in-Charge.
Suply and fixing louvers in repairs of PVC for exhaust fan of size 250/300/450 mm sweep complete all as specified and directed.
Suply and fixing louvers in repairs of steel for exhaust fan of size 250/300/450 mm sweep complete all as specified and directed.
Cutting of wall for fixing exhaust fan of PVC/Iron fan of size 250/300/450 mm including fixing requirment at site by grouting fully threaded bolt and nuts including connection complete with one meter copper wire and repair complete, painting of wall all as directed & specified by Engr-in-Charge.
Taking down carefully existing Aluminum/Copper point wiring (light/ Fan / Socket/Power Point) complete fittings etc. making good to disturbed surface of wall/Floor etc to match the existing surface/ finishes all as directed.
M&L for concealed point wiring for one light/ fan/ bell point controlled by one switch with1.5 Sqmm (Nominal area) PVC insulated, unsheathed, stranded copper, conductor cable FRLS (1100Volts grade) drawn in and including PVC conduits of 20 mm dia with all fittings and accessories alongwith PVC insulated cable with copper conductor of size 1.5 Sqmm as earth continuity conductor including fixing of 1. 2mm thick MS sunk terminal box duly flushed to wall with 3mm thick plastic laminated/ebonite sheet cover fixed with screws,cap and washers incl. making good the disturbed surfaces complete all as specified and directed.
All as per item No.17 here in before but for socket outlet 3/5 pin 5 amp. on the same board.
All as per per item No 17 here-in-before but for one light point controlled by two Nos of 2 way switches complete all as specified and directed.
All as per item No 17 here-in-before but for switch socket combination 5 Amps 3/5 Pin point on independent board .
M&L for concealed point wiring with 2.5 Sqmm (Nominal area) PVC insulated,unsheathed, multi stranded Copper conductor cable drawn in and including PVC rigid PVC conduit 25mm or higher size with all its fittngs and accessories for one 3 pin/6 pin 15 Amps socket out let point independent alongwith PVC insulated cable with solid copper conductor 1.5 Sqmm (nominal area) continuous earth wire, and connected to earth dolly including fixing of 1.20mm sunk pressed steel terminal box suitably flushed to wall with 3mm thick Hylum sheet cover fixed with screws & cup washers incl. making good complete all as specified and directed.
Supply and Fixing in repairs Modular switches 1 way, 6 A, 1 module
Supply and Fixing in repairs Modular switches 1 way, 16 A, 1 module
Supply and Fixing in repairs socket outlet ,3/5 pin 5 amp flush type
Supply and Fixing in repairs socket outlet 2 in one, 3/5 pin 5 and 15 Amp flush type
Supply and Fixing in repairs Modular sockets 6 A, 2/3 pin combined 2 module
Supply and Fixing in repairs Modular sockets 6 A/16 A, 2/3 pin combined 2 module
Supply and Fixing in repairs lamp holder PVC Angular/ pendent/ bakelite.
Supply and Fixing in repairs buzzer, capton ding dong,AC,230V,Single Pole
Supply and Fixing in repairs Modular fan regulators step type, 120 W, 2 module
Supply and Fixing in repairs fan regulator resistance/electronic step type single phase 230 volt.
Supply and Fixing in repairs Condenser 2.5 Mfd make universal/Usha /Bajaj.
Supply and Fixing in repairs Condenser 3.5 Mfd make universal/Usha /Bajaj.
Supply and Fixing in repairs MCB SPN 20 to 32 Amps 240 volts.10kA . Make - Legrand/L&T/ Havells
Supply and Fixing in repairs MCB SP 6 to 32 Amps 240 volts, 10 kA. Make - Legrand/L&T/ Havells
Supply and Fixing in repairs MCB TPN 63 Amps,415V,10kA Make - Legrand/L&T/ Havells
Supply and Fixing in repairs MCCB TPN 100 Amps, 415V, 16kA ,Thermal Magnetic Release Make - Legrand/L&T/ Havells
Taking down unserviceable existing sub main wiring of aluminium conductor stranded cable upto and including of any size single core including earth wire from existing conduit or wooden battens including taking out unserviceable wooden gutties etc, matching with the existing surfaces complete all as specified and as directed.
M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 4.0 Sqmm (Nominal area) multi stranded copper conductor cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of copper conductor of size 4.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduit of 25mm dia medium grade size incl. making good the disturbed surface complete.(Note : PVC conduit and its accessories including 2 runs of cable & 1 run of earth continuity conductor cable unsheathed shall be measured and paid as single unit).Make of cable : Polycab/Finolex/Havells,ISI Marked
M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 6.0 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 6.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduits of 25 mm dia medium grade size incl. making good the disturbed surfaces complete.(Note : PVC conduit and its accessories including 2 runs of cable & 1 run of earth continuity conductor cable unsheathed shall be measured and paid as single unit).MAKE OF CABLES : Polycab/ Finolex/Havells,ISI Marked
S&F in replacement sheet metal enclosure DB's 415 Volts, IP-42, vertical suitable for mounting MCCB's, TPN, 4 way with 200 Amps rated copper bus bar complete all as directed by Engineer-in-charge.
Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 4 ways Make Make Legrand or equivalent make of HPL Moeller/L&T Hagger/Havells complete all as specified and directed.
Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 8 ways Make Make Legrand or equivalent make of HPL Moeller/L&T Hagger/Havells complete all as specified and directed.
Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 12 ways Make Make Legrand or equivalent make of HPL Moeller/L&T/ Hagger/Havells complete all as specified and directed.
Supply and Fixing in repairs 4 Pin CFL lamp 36Watt , Make : Bajaj/Havells/Philips
S & F in repairs 2 Pin CFL 18 W lamp, Led bulb of thread type, focused light Make : Bajaj/Havells/Philips
S&F LED retrofit tube with PVC extruded battern 20watt 4 feet White colour including dismentiling and taking down any type of FTL/LED complete all as specified and directed.Make- Orient/Havells/Bajaj/CG
S&F in replacement LED fitting with PVC extruded battern 20 watt 4 feet with inbuilt charging circuit for battery ( battery type lithum) and power back up White colour including dismentiling and taking down any type of FTL/LED complete all as specified and directed. Make- Orient/Havells/Bajaj/CG
S & F retrofit LED tube rod 18/20 W, 4 feet for fixing in existing LED/FTL light fitting Make- CG / Philips/Bajaj/Orient .
S & F Side holder suitable for existing LED/FTL fittings as per site requirement.
S&F in repairs building scurity light LED type 20 watt including GI pipe bracket 32 mm dia with clamp including complte connection wih copper wire all as directed and specified by Engr-in-Charge.
S&F in repairs 9W LED bulb of of B22/B27 type.
S&F LED mirror light fixture 10 Watt LED 6000K 50Hz 240V.
S&F LED fountain light of min. 10 watt as specified and directed by Eng - in-Charge.
S&F machine screw for fitting hylem sheet.
S&F 2'x 2' LED recess/ surface mounted fitting 36 Watt, 230V, with integrated electronic driver high transcluent frosted diffuser, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make- Orient/Havells/Bajaj/CG/Philips
S&F 1'x 1' LED recess/ surface mounted fitting upto18 Watt, 230V, with integrated electronic driver high transcluent frosted diffuser, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make- Orient/Havells/Bajaj/CG/Philips
S&F recess/surface mounted LED downlighter of round/square upto 12w concealed /surface mounted with removable driver complete all as specifid and directed.
S&F in replacement of PVC non metallic casing caping of 25mm size with accessories such as saddle etc.
Supply and fixing 1.5 sqmm copper wire in replacement of old wire.
Supply and fixing 2.5 sqmm copper wire in replacement of old wire.
Supply and fixing 4.0 sqmm copper wire in replacement of old wire.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVCinsulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sqmm 2 core nominal cross section in service connections complete all as specified and directed.
Supply and fixing LED post top lantern with die cast aluminium spigot, spun aluminium powder coated top cover, Alumnium PDC heat sink, opal PC diffuser and clear acrylic of Havells,C&S, phillips.
S&F repairs paino switch flush type 5 Amps single pole one way complete all as specified and directed.
S&F repairs paino switch flush type 15 Amps single pole one way complete all as specified and directed.
Notes :- (i) For Serial No 01 to 15: The contractor has to complete the work assigned for said items with in 10 days from issue of fan through gate pass failing in which recovery at the rate of Rs. 25 per day per complaint shall be deduct. (ii) For Serial No 16 to 66 : The Contractor has to complete the work assigned for above items with in 72 hours failing in which recovery at the rate 25 Rs. Per day per complaint (iii) The contractor has to maintain a separate complaint slip book and complaint register for attending complaint. The contractor rep have to collect daily complaint slip from the E/M complaint cell on the same day at 09 AM and get them signed from user after completing the job and submit to E/M complaint cell.
N S ELECTRICALS
S.S.ENTERPRISES
avon electric engineering woks
Shri Siddhi Vinayak Constructions
M/s. S.S. Refrigeration, Bareilly
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .