Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 CrAdmitted-Finance B 1 245 NEW DELHI WEST DELHI DELHI 110063 | WEST DELHI | DELHI | 110063 | ₹7.3 Cr | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | AAR ESS EXIM PVT LTD L1 |
|---|---|---|---|---|
| 1.00Part-A (Supply of Material) | ||||
| 1.01 | 145 KV SF6 Circuit Breaker | 1 | Nos. | 8,00,000 ₹8,40,000 Lowest |
| 1.02 | 145 KV Horizontal Double Break Isolator with Earth Switch | 1 | Nos. | 2,80,000 ₹2,90,000 Lowest |
| 1.03 | 145 KV Horizontal Double Break Isolator without Earth Switch | 2 | Nos. | 2,80,000 ₹5,80,000 Lowest |
| 1.04 | 145 KV Current Transformer 200/100/50/1A, 0.2S with CT clamp with Rod Type Bushing (without thread bushing) and Junction Box | 3 | Nos. | 1,60,000 ₹4,95,000 Lowest |
| 1.05 | 145 KV Current Transformer (200/100/50/1A), Accuracy Class-0.2S with CT clamp with Rod Type Bushing (without thread bushing) and Junction Box and having only metering core. | 3 | Nos. | 1,60,000 ₹4,95,000 Lowest |
| 1.06 | 145 KV Potential Transformer 132KV/110V with PT clamp with Rod Type Bushing (without thread bushing) and Junction Box. | 3 | Nos. | 1,60,000 ₹4,95,000 Lowest |
| 1.07 | 145 KV Potential Transformer 132KV/110V with PT clamp with Rod Type Bushing (without thread bushing) and Junction Box and having only metering core. | 3 | Nos. | 1,60,000 ₹4,95,000 Lowest |
| 1.08 | 120 KV LA (10 KV, Gapless Type) | 3 | Nos. | 52,000 ₹1,62,000 Lowest |
| 1.09 | 132 KV Control & Relay Panel for feeder | 1 | Nos. | 15,00,000 ₹15,20,000 Lowest |
Tender Value
₹1.2 Cr
EMD Value
₹3.5 L
Closing Date
31 Jan 2023, 12:00 pmClosed
GM (EM)
WAPCOS LIMITED 76-C, SECTOR-18, GURGAON
Construction of 01 No. 132 kV Bay at 132 kV Substation Kichha for 132 kV Kichha-Lalkuan Railway Line, Uttarakhand
2023_WAPCO_141095_1
WAP-EM-TENDER-132kV-SS-2023-01
Open Tender
Electrical Works
Item Rate
120 days
KICCHA, HALDWANI
Please refer Tender documents.
3 documents required · 3 mandatory
₹17,700
WAPCOS Limited
₹3.5 L
13 Feb 2023
10 Jan 2023
1 Feb 2023
10 Jan 2023
31 Jan 2023
10 Jan 2023
10 Jan 2023 - 13 Jan 2023
Amount
Part-A (Supply of Material)
145 KV SF6 Circuit Breaker
145 KV Horizontal Double Break Isolator with Earth Switch
145 KV Horizontal Double Break Isolator without Earth Switch
145 KV Current Transformer 200/100/50/1A, 0.2S with CT clamp with Rod Type Bushing (without thread bushing) and Junction Box
145 KV Current Transformer (200/100/50/1A), Accuracy Class-0.2S with CT clamp with Rod Type Bushing (without thread bushing) and Junction Box and having only metering core.
145 KV Potential Transformer 132KV/110V with PT clamp with Rod Type Bushing (without thread bushing) and Junction Box.
145 KV Potential Transformer 132KV/110V with PT clamp with Rod Type Bushing (without thread bushing) and Junction Box and having only metering core.
120 KV LA (10 KV, Gapless Type)
132 KV Control & Relay Panel for feeder
145 KV Bus Post Insulator Solid Core Type
Lattice Type Structure with N&B and Anchor Bolts
Auxiliary Control and Power Cables
2.5 Sq.mm, 10 Core Armoured Copper Control Cable
2.5 Sq.mm, 06 Core Armoured Copper Control Cable
2.5 Sq.mm, 4 Core Armoured Copper Control Cable
2.5 Sq.mm, 2 Core Armoured Copper Control Cable
35 Sq.mm, 3.5 Core Aluminium Power Cable
132 KV XLPE cable 240 Sqmm
Outdoor termination kit suitable for 240 sqmm 132 KV XLPE cable
Main Earth Mat and Riser (MS Round 40 mm Dia)
75×12 mm MS Flat
50X6 mm MS Flat
Disc Insulator 70 KN
Suspension Fitting for ACSR Zebra Conductor
ACSR Zebra Conductor
C-wedge Clamp Suitable for ACSR to Zebra to Zebra Conductor
150 Watt LED flood light with fitting
Description of Work / Item(s)
Amount
Part-B (Erection of Material): Erection and Commissioning of following structures/equipments panels auxiliaries etc as per standard procedures
145 KV SF6 Circuit Breaker
145 KV Horizontal Double Break Isolator with Earth Switch
145 KV Horizontal Double Break Isolator without Earth Switch
145 KV Current Transformer 200/100/50/1A, 0.2S with CT clamp with Rod Type Bushing (without thread bushing) and Junction Box
145 KV Current Transformer 200/100/50/1A, 0.2S with CT clamp with Rod Type Bushing (without thread bushing) and Junction Box and having only metering core.
145 KV Potential Transformer 132KV/110V with PT clamp with Rod Type Bushing (without thread bushing) and Junction Box.
145 KV Potential Transformer 132KV/110V with PT clamp with Rod Type Bushing (without thread bushing) and Junction Box and having only metering core.
120 KV LA (10 KV, Gapless Type)
132 KV Control & Relay Panel for feeder
145 KV Bus Post Insulator Solid Core Type
Lattice Type Structure with N&B and Anchor Bolts
Auxiliary Control and Power Cables
2.5 Sq.mm, 10 Core Armoured Copper Control Cable
2.5 Sq.mm, 06 Core Armoured Copper Control Cable
2.5 Sq.mm, 4 Core Armoured Copper Control Cable
2.5 Sq.mm, 2 Core Armoured Copper Control Cable
35 Sq.mm, 3.5 Core Aluminium Power Cable
132 KV XLPE cable 240 Sqmm
132 KV outdoor termination suitable for 240 sqmm
Main Earth Mat and Riser (MS Round 40 mm Dia)
75×12 mm MS Flat
50×6 mm MS Flat
Disc Insulator 70 KN
Suspension Fitting for ACSR Zebra Conductor
ACSR Zebra Conductor
C-wedge Clamp Suitable for ACSR Zebra to Zebra anther Conductor
150 Watt LED flood light with fitting
Dismentaling of 145 KV Current Transformer (1600/800/400/1A)
Dismantaling of 145 KV CVT Transformer (132KV/110V )
Re-erection of 145 KV Current Transformer (1600/800/400/1A)
Re-erection of 145 KV CVT Transformer (132KV/110V )
Dismentaling of 145 KV Circuit Breaker
Re-erection of 145 KV Circuit Breaker
Dismentaling of all three phase ( R,Y & B) of existing overhead ACSR Panther conductor approx length (35 Meters)along with hardwares, disc insulator, tension fitting and suspension fitting etc. complete in all respect.
Part-B (Civil Works)
Supply and Spreading of earth by earth work in excavation by mechanical means(Hydraulic Excavation/ manual meansover surface area, consolidating each layer by ramming and watering.
Earth work in excavation by mechanical means (Hydraulic excavation)/manual means over surface areas including disposal of surplus excavated soil as directed. Disposed earth should be neatly levelled and dressed.
Providing and laying in position cement concrete of specified grade including the cost of centering shuttring etc. in ratio of 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete, including the cost of cenetering, shuttering, finishing etc. in ratio of 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size )
Providing and laying in position of reinforcement cement concrete, including the cost of cenetering, shuttering, finishing etc. In ratio of 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size )
Bricks work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 Cement : 4 coarse sand )
12 mm cement plaster of mix 1:4 (1cement : 4 fine sand )
MS Steel bar work including supply of material, cutting, bending, moulding etc complete in all respect as per direction of engineer in charge
Description of Work / Item(s)
Amount
Part-A (Supply of Material)
Total Part-A(Supply of Material) from BoQ1 sheet without GST
Total Part-B (Erection of material and Civil Works) from BoQ2 sheet without GST
Add GST*Amount on (Total of Part-A + Total of Part-B above)
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
TENDERDOCUMENT.pdf
Tender Documents • 2.05 MB
BOQ_154244.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .