| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 LAccepted-AOC BLDG NO XI 74 NEAR VALLARAM KULLANGARA TEMPLE KUNHIMANGALAM KOVVAPPURAM PO KANNUR DIST KERALA 670309 | KANNUR | KERALA | 670309 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹6.6 L+₹1.1 L (20.3%)Rejected-AOC 145H 2G AQAMA MODEL APARTMENT LUKERGANJ PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211001 | L2 | Rejected-AOC being L2 | |
| 3 | L3₹8.3 L+₹2.8 L (50.7%)Rejected-AOC | L3 | Rejected-AOC being L3 |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
16 Nov 2021, 6:00 pmClosed
AGE (I) Cannanore
AGE (I) Cannanore HQ Hospital Kannur PO Kannur
Repairs to flooring, plumbing, joineries etc to certain md accns of PAO (OR) at Burnassery, Kannur under AGE (I) Cannanore.
2021_MES_473241_1
8145
Open Tender
Civil Works
Item Rate
120 days
Cannanore
Class E category a(I)
8 documents required · 8 mandatory
₹300
Yes
AGE (I) Cannanore
₹10,000
Yes
23 Dec 2021
6 Sept 2021
20 Nov 2021
7 Sept 2021
16 Nov 2021
20 Sept 2021
Amount
Demolition of brick or stone / boulder masonry built in cement or cement lime mortar, including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work and pre cast concrete articles and removing debris outside MD land all as directed.
M&L for laterite stone masonry, regular coursed, well bonded and solidly hearted , built in CM (1:6) all as specified and directed.
All as per item No 2 here in before but except laterite all as specified and directed. Note : Serviceable laterite stone obtained from item No 1 shall be reused.
Taking down cement or cement lime plaster on brick/stone walls or in ceiling surfaces incl racking out joints hacking for key scrubbing down with water etc and removing rubbish outside MD land all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on stone masonry surfaces, finished even and smooth without using extra cement all as specified and directed .
M&L for rendering 15mm thick in cement mortar (1:4) on stone masonry surfaces, finished even and smooth without using extra cement all as specified and directed .
M&L for rendering 5mm thick in cement mortar (1:3) on ceiling surfaces, finished even and smooth without using extra cement all as specified and directed .
M&L for preparation of new plastered surfaces and applying 3 coat of white wash on walls surfaces all as specified and directed.
M&L for preparation of new plastered surfaces and applying 2 coat of cement base paint over a coat of primer on walls surfaces all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removing debris outside MD land all as directed.
M&L for PCC 1:2:4, type B1 using 20mm graded stone aggregate for fixing hold fast, coping, bed block etc including necessary form works all as specified and directed.
M&L 40mm thick PCC 1:2:4, Type B1 (using 20mm graded stone aggregate) as in flooring and finished even and smooth without using extra cement all as specified and directed.
M & L for 75 mm thick plain cement concrete 1:3:6, type C2 using 40mm graded aggregate as in plinth protection etc including necessary form work complete all as specified and directed
Taking down chowkats with shutters any description n exc. 1.5 Sqm each (without taking off shutters from the frame) all as directed.
Taking down chowkats with shutters any description exc. 1.5 Sqm but n.exc 4 Sqm each (without taking off shutters from the frame) all as directed.
Taking down wooden door shutters of any description n exc 1 Sqm each all as directed.
Taking down wooden door shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each all as directed.
M&L solid PVC door frame of sizes 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, all as specified and directed.
S&F factory made solid PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain coloured PVC “C” channel having a PVC sheet strip of 20mm width stock inside with solvent cement for stiles and plain colour PVC sheet for top rails, lock rails and bottom rails on either side and as gap insert for top rail & bottom rail on either side and as gap insert for top rail and bottom rail, paneling of plain colour of PVC sheet fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement etc. Details as peer specification and drawings and all as directed.
M&L for mild steel flat iron of size 25 x 3mm for holdfasts for securing new wooden frames and similar articles conforming to Fe-290 Gde-E-165 all as specified and directed.
M&L for second class hardwood, plain, solid straight chowkats & frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints all as specified and directed.
All as per item No 21 here in before but for with transoms and mullions, with double rebated on the solid frame for fixing double shutters all as specified and directed.
S&F 30mm thick second class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc; (with out sash bars), edges of framing, fitted with cut and mitered beads for securing glass, etc sizes of members of shutters as specified in SSR Part-I, Section 8, Clause 8.24 (a) all as specified and directed.
M&L for second class hardwood, panelled shutter 30mm thick (two panel) with lock rail and panel of 9mm BWP, 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated all as specified and directed.
S&F 4mm thick plain sheet glass, ordinary quality and glazing with oil putty in squares not exc 0.50 Sqm in each pane all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) n exc 1.5 sqm from wooden frames including beads all as directed.
S&F in repairs stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and directed.
S&F 30mm thick second class hardwood glazed and skeleton shutters, open rebated, edges of framing plain, chamfered or rounded, fitted with cut and mitred and rebated sash bars, divided into squares, for securing glass gauze, etc; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.20(b) all as specified and directed.
S&F stainless steel butt hinges medium weight; 100mm size as per IS 21817 fixed with stainless steel screws all as specified.
S&F stainless steel butt hinges medium weight; 75mm size as per IS 21817 fixed with stainless steel screws all as specified.
S&F 100mm long aluminum anodized barrel tower bolts of extruded section fixed with stainless steel screws all as specified.
S&F extruded aluminum alloy anodized handle fabricated type 150mm size fixed with stainless steel screws all as specified.
S&F extruded aluminum alloy anodized handle fabricated type 100mm size fixed with stainless steel screws all as specified.
S&F aluminium anodised sliding door bolts 300mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and directed
S&F in repair aluminium anodised sliding door bolts 300mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and directed
Supply and Fix in repairs Netlon ( Good quality ) for fly proofing (Necessary beading will be measured in the appropriate item ) as specified and directed.
S&F for second class hard wood, plain fillets, square, rectangular or triangular in section, clean sawn, sectional area exc.6 & n. exc. 13 sqcm secured with nails or brads all as specified and directed.
Taking up or down steel tubing and connecting including cleaning for removing to store of sizes upto 25mm bore all as directed.
S&F for 15mm bore UPVC (ASTM) pipes of pressure rating 10 kgf / cm2, fixed complete to walls, ceilings or in floors etc. all as specified and directed.
S&F for 20mm bore UPVC (ASTM) pipes of pressure rating 10 kgf / cm2, fixed to wall/ceiling or on floor all as specified and directed.
S&F for 25mm bore UPVC pipes of pressure rating 10 kgf / cm2, fixed to wall/ceiling or on floor all as specified and directed.
S&F in repairs bib tap 15mm dia, chromium plated, cast copper alloy, screwed down, screwed for iron pipe or ferrule and complete all as directed.
S&F in repair 15mm pillar taps, cast copper alloy with capstan heads, chromium plated , screwed down high pressure ,with or without lettered hot or cold with long screwed shanks and fly nuts screwed for iron pipe and fixed all as specified and directed.
S&F in repairs stop cock 15mm bore cast copper alloy, chromium plated, screwed both ends for iron pipe or for unions and screwed down, high pressure with long shank & cup complete all as specified and directed
S&F 500 litres capacity rotational moulded polthylene water storage tanks(cylindrical vertical with closed top) of make Sintex/Polycon/Plasto hoisted and fixed in position including taking down unserviceable water tank all as specified in SSR Part I,2009 and directed.
S&F in repairs Vitreous China Wash down water closet pan (Pedestal pattern) white, (excluding flushing cistern and flush type) pedestal pan and trap including connection to drain (or outgoing pipe) and to flushing pipe, anti syphonage pipe, etc complete including plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminized hinging device all as specified and directed.
S&F in repairs PVC valveless, syphonic action type flushing cistern low level, 10 Litre capacity, white, with inlet, ball valve, float and handle including low or high density PVC flush pipe all as specified and directed.
Supply and fix PVC connecton 60cm long with PTMT nuts for flush tank, wash basin, etc. all as specified and directed
S&F 32mm Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed all as specified and directed.
S&F mild steel chromium plated Health faucet (ABS body), suitable for 15mm dia pipe with flexible LDPE pipe with jet of 1.25m long on one end and socket joint of 15 mm dia on other end including ABS wall hook complete all as specified and directed.
S&F in repairs PVC lid or cover for PVC OH water tank suitable upto 1000 litre capacity of Sintex or Polycon complete all as specified and directed
Cleaning of blockage of WC Indian or European type by removing sludge and sediments getting out including cleaning and rodding of sewage pipe upto first manholes and flushing with water after cleaning, removing and depositing sludge in a pit n exc 50m from the WC as including necessary excavation in hard / dense soil , refill and disposal of surplus soil etc complete all as directed.
S&F in repairs ball brass valves, high pressure, with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule of 20mm bore dia all as specified and directed.
S&F in repairs White plastic seat cover, solid type lid with C.P. brass hinges and rubber buffers complete all as directed by Engineer-in-Charge.
S&F in repairs PVC low or high density PVC flush pipe 32mm dia suitable for low level flushing cistern all as specified and directed.
S&F in repairs PTMT 32mm Waste fittings, any colour weighing not less than 45gm per each suitable for sinks, basins, etc. with long screwed shanks and fly-nuts, flange end all as specified and directed.
M&L PVC (SWR) pipe type 'B' 75mm bore single socketed with solvent cement joints laid in trenches or in floors all as specified and directed.
M&L PVC (SWR) pipe type 'B' 75mm bore single socketed with solvent cement joints fixed to wall all as specified and directed.
M&L PVC (SWR) pipe type 'B' 110mm bore single socketed with solvent cement joints laid in trenches or in floors all as specified and directed.
M&L PVC (SWR) pipe type 'B' 110mm bore single socketed with solvent cement joints fixed to wall all as specified and directed.
Taking out and cleaning of existing roof treatment of any description by wire brushing and cleaning top surface with water etc. and providing cement plaster 15mm thick in cement mortar (1:4) on concrete surfaces, finished even and smooth without using extra cement for receiving water proofing treatment. M & L for water proofing treatment to RCC roof with APP modified prefabricated five layer membrane of 4mm thick and weight not less than 4.00 Kg per Sqm reinforced with non woven polyster matt reinforcement 160gsm (weighing not less than 160gms/sqm) over a solvent based bitumen primer, Shalitex primer @ 0.30 litre per Sqm of same manufacturere conf to IS 3384-1986. Membrane shall be laid by torch application including minimum 7.5cm side overlap and 10cm end lap. All cracks in roof shall be filled with cement putty using suitable bonding agent (Shalocrete 42) before laying cement plaster all as specified and directed.
Taking down carefully copper/aluminium point wiring of light, fan, socket or power complete, including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of walls, floor ceiling etc. all as directed
M&L Point wiring complete with 1.5 Sq mm single core PVC insulated unsheathed copper conductor FRLS cable multi stranded 1100 Volt grade drawn through and including non metallic rigid PVC conduit open to wall and fixed to ceiling/roof etc with necessary fixing accessories such as bend elbow socket etc with fixing material including terminal box made out of 1.22mm thick MS sheet concealed in wall covered with laminated sheet top cover of 3mm thick cadmium plated screws with cup washer including 1.5Sqmm single core PVC insulated un sheathed copper conductor FRLS cable multi stranded 1100Volt grade as earth continuity conductor green in colour connected to common earth dolly complete all as specified and as directed for One light/fan/bell point controlled by one switch.
All as per item No 64 here in before but for One light point controlled by two way switch all as specified and directed.
All as per item No 64 here in before but for One 3 Pin, 5 Amps socket on same board with other switches all as specified and directed.
All as per item No 64 here in before but for One 3 Pin, 5 Amps switch socket combination on independent board all as specified and directed.
All as per item No. 64 on here in before but for one 3 pin 15 amp switch socket combination on independent board with 2.5Sqmm unsheathed PVC insulated copper conductor FRLS cable including 2.5 Sqmm PVC insulated copper cable for earth continuity conductor complete all as specified.
S & F switch piano flush type, single pole, one way, 5 Amps, 240 volt including connecting up electrically complete all as specified and as directed.
S & F switch piano flush type, single pole, two way, 5 Amps, 240 volt including connecting up electrically complete all as specified and as directed.
S & F PVC ceiling rose round shape, three terminals, polycarbonate, isolated body including connecting up electrically all as specified and as directed.
S & F switch socket combination, 5pin 5/6 Amps, multipurpose, flush type, non-interlocking type, including connecting up electrically complete all as specified and directed.
S & F switch socket combination, 2 in 1, 5 &15 Amps, multipurpose, flush type, non-interlocking type, including connecting up electrically complete all as specified and directed.
S & F socket 5pin 5/6 Amps, multipurpose, flush type, non-interlocking type, including connecting up electrically complete all as specified and directed.
S & F switch bell push, flush type, 240 Volts, single pole, 5 Amps including connecting up electrically all as specified and directed.
S& F calling bell electric AC 240V, single pole, ding dong type and connecting up electrically all as specified and directed.
Taking down unserviceable fluorescent tube light fittings, S & F Decorative ultra slim linear LED light fittings with extruded AI, heat sink, environmental friendly, energy efficient ready to use pack of 20 W LED 6500K, model of SSK-SQ2201-AL of Syska or LDLL 20-CDL of Crompton Greaves or equivalent in Philips, with all accessoried internally prewired and including connecting up with twin core twisted copper flexible conductor cable of sutibale size all as directed.
Taking down unserviceable fluorescent tube light fittings, S & F Decorative ultra slim linear LED light fittings with extruded AI, heat sink, environmental friendly, energy efficient ready to use pack of 10 W LED 6500K, model of SSK-T-5 of Syska or equivalent of Crompton Greaves or in Philips, with all accessoried internally prewired and including connecting up with twin core twisted copper flexible conductor cable of sutibale size all as directed.
S & F sheet metal enclosure factory made for MCB DB, SPN 8 way with 200 Amps bus bar, 240 Volt, double door type, fixed/flushed on wall including electrically connecting up and taking down old unserviceable DB complete all as specified and directed.
S & F sheet metal enclosure factory made for MCB DB, TPN 4 way with 200 Amps bus bar, 440 Volt, double door type, fixed/flushed on wall including electrically connecting up and taking down old unserviceable DB complete all as specified and directed.
S & F MCB SPN, 240 Volt, 40Amps including electrically connecting up using wiring lugs all as specified and directed.
S & F MCB SP, 240 Volt, 6 to 32Amps including electrically connecting up using wiring lugs all as specified and directed.
S & F MCB TPN, 415 Volt, 10KA, C curve, 63Amps including electrically connecting up using wiring lugs all as specified and directed.
M&L for sub main wiring with two runs of single core 4 Sq mm copper conductor FRLS cable, PVC insulated, unsheathed multistanded, 1100 V grade drawn through and including non metallic rigid PVC all accessories such as bend,elbow,socket,tee saddles etc fixed concealed to wall / fixed to ceiling etc including 4 Sq mm single core copper conductor FRLS cable PVC insulated, unsheathed multistranded 1100 V grade as earth continuity conductor connected to common earth dolly complete all as specified and directed. Note :- 3 runs of 4 Sq mm copper cable and one run of PVC conduit will be measured as one length.
M & L for earthing complete with galvanized steel earth plate electrode 60cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron connected to earthing test point, main DB, panel board, continuous earth lead protected by 15mm bore GI pipe light grade, 20mm bore GI light grade pipe for watering, necessary excavation and earth work in any type of soil, PCC pit, RCC chamber cover with suitable reinforcement complete all as shown on electrical plate No 3 of SSR part-I of 2009 all as specified and directed. Note :- Rate quoted shall deem to include for GI earth and GI pipe lead upto 7.5m length.
Taking down carefully ceiling fan with rod from ceiling / roof and refixing the same after repairs such as servicing, greasing, replacement of ceiling fan down rod of suitable length, clamps, nuts, washers, rubber bushes, safety pin etc as required and applying one coat of white synthetic enamel paint and writing of MES No complete including connecting up with 2 core twisted flexible copper conductor 23/0.0076 from ceiling rose to fan , test and commissioning all as specified and directed. Note : Rewinding and replacement of capacitor & bearing shall be measured and paid seperately.
Rewinding of ceiling fan 1200 mm sweep any type and make, cutting and removing burnt winding wire without damaging stator, removing old insulation of polyester paper, re-winding fan motor with super enameled copper wire of same gauge/dia with correct number of turns for auxiliary and main winding, varnishing, baking, soldering new lead of twin core multi-stranded copper conductor cable of size 23/0.0076, assembling, replacement of capacitor 2.5mfd and re-fixing, testing and commissioning complete all as specified and directed.
Supply only ball bearing of suitable for ceiling fan 1200mm sweep including removing old un-serviceable bearing and testing complete all as specified and directed.
S&F stepped type electronic fan regulator, full rotation,200W, SP, 230V onnecting up electricallyall as specified and directed.
Supply only fan capacitor 2.5mfd , make Havells or equivant of Bajaj/LG.
S&F in repalacement LED ball type lamp 10watt all as directed.
Supply and fixing LED bulk head luminaries of 10 watts on wall of energy saving and environmental friendly long life with driver of HAVELLS or equivalant of CG or Philips and electrically connecting up all as directed.
S&F in repalacement lamp holder, PVC/poly carbonate type with back plate suitable for batten fitting all as directed.
M&L for preparation of new plastered surfaces and applying 3 coat of white wash on ceiling surfaces all as specified and directed.
Dismantling and breaking up drain pipes (salt glazed drain pipes, AC or RCC) set in cement mortar any dia of pipes and removing debris outside MD land
M&L for preparation of new wooden surfaces of any description, not otherwise described exc 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer all as specified and directed.
Yash enterprises
SANTOSH CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .