Office of the Exe Engr, North 24 pgs EL DIV, PWD,
Office of the Exe Engr, North 24 pgs EL DIV, PWD, KOL- 59
Supply, installation, testing and commissioning (SITC) of 13 nos. air-conditioning units at different office rooms at Directorate of Commercial Taxes, Barasat Charge , Kolkata- 700124 through PWD
2024_WBPWD_709781_1
WBPWD/EE/N24/EL/eNIQ-139/24-25
Open Tender
MISC ELECTRICAL WORKS
Item Rate
21 days
Barasat
Please refer Tender documents.
4 documents required · 4 mandatory
₹26,241
Office of the Exe Engr, North 24 pgs EL DIV, PWD
25 Sept 2024
9 Jul 2024
8 Aug 2024
9 Jul 2024
6 Aug 2024
17 Jul 2024
15 Jul 2024
Amount
PART -- A ( E.I. WORK ) Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (RR/Polycab/Finolex) partly in 20mm size PVC rigid conduit 'FR' (Brand approved by EIC) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N copper bar incl. bakelite/ Perspex top cover 3 mm thick as per GS. -- [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] Average Run -- 8 Mtr. [ 6(c)/E-16 ]
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (RR/Polycab/Finolex) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick as per GS. -- On Board [ 4(a)/E-15 ]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (RR/Polycab/Finolex) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [ 1(a)/(ii)/E-14 ] [ For ComB ]
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC [ For AC Pt. ] [ 1(a)/(iii)/E-14 ]
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC [ 1(a)/(iv)/E-14 ] [ For SPNDB ]
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick as per GS. [ 26/E-7 ] [ ComB ]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall as per GS. -- [ 5(a)/E-17 ] [ For AC Pt. ]
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate as per GS. -- [ 17/E-19 ] [ For AC Pt. ]
S & F AC Machine Timer Control Box fixed on wall fabricated with Double door ( 2 + 10 ) Way SPNDB enclosure as per -- ( Make - L&T, Cat no - LTSD12N ) incl. interconnection with suitable size of PVC insulated copper wire incl. Socketting with Copper socket with required size and following accessories -- i) 240/415 V, 32 A DP MCB of Breaking Capacity 10 KA & ''C'' Charecteristics ( Make - L&T ) - 1 nos. ii) 22A 2 Pole Power Contactor with 220 coil voltage ( Make -L&T, MNX - 22 - 2P with 1 NO, Cat no - CS94980 ) - 1 nos. iii) Digital Time Switch ( Make - L&T, Cat No - Crono 67DDTO ) - 1 nos. iv) LED lamp for Indication purpose -- 1 nos. v) Auto/Manual Toggle Switch -- 1 nos. vi) 2 Way Connector - 2 nos. [ NS ]
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. 100 A TPN SFU on angle iron frame ( Make - L & T ) [ 4(a )/D-3 ]
Supplying and fixing Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc 63 A, 415V, Four Pole Changeover switch (Make - Havells) [ 2(b)/D-1 ]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages as per GS. 4 Way Enclosure ( 607715 ) [ Make - Legrand ] [ 14/D-10 ]
6 Way Enclosure ( 607716 ) [ Make - Legrand ] [ 14/D-10 ]
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damagesas per GS. Upto 160A, 4 Way Enclosure ( 607913 ) [ Make - Legrand ] [ 15/D-11 ] [ For Incoming Main VTPNDB ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs as per GS. -- 6-32 A SP MCB [ Make - Legrand ] [ 7/D-6 ]
63 A TP MCB ( Make - Legrand ) [ 7/D-6 ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs as per GS. -- 63 A FP [ Make - Legrand] [ 6/D-5 ]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. 100A Four Pole [ Make - Legrand ] [ 10/D-8 ]
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works. 19 mm dia 3 mm thick polythene pipe without earth continuity wire. [ 3(a)/ E-2 ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (RR/Polycab/Finolex) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [ 1(s)/E-9 ] [ For ComB ]
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) as ECC [ For AC Pt. ] [ 1(v)/E-9 ]
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC [ 1(y)/E-14 ] [ For SPNDB ]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes as per GS. 2.5 Sq mm [ 9(i)/ F-5 ]
4 Sq mm [ 9(ii)/ F-5 ]
6 Sq mm [ 9(iii)/ F-5 ]
Supply of 4 Core PVC/XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes. [ Make - Polycab/Gloster/RR ] 4 core 35 Sq. mm Cable. [ NS ] [ From VTPNDB to TPNDB ]
4 core 50 Sq. mm Cable. [ NS ] [ For Incoming of VTPNDB ]
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire as per GS. -- [ 2(c)/F-1 ] [ For 4 Core 35 Sq mm. & 4 Core 50 Sq mm. ]
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damagesas per GS. -- From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc. [ 5(i)/F-3 ] [ For 4 Core 35 Sq mm. ]
Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc. [ 5(ii)/F-3 ] [ For 4 Core 50 Sq mm. ]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry as per GS. For 4 core 35 Sq. mm. [ 7(c) /F- 4 ]
For 4 core 50 Sq. mm. [ 7(c) /F- 4 ]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make) as per GS. 4 core 35 Sq mm. cable [ 8(b)/(xv)/F-5 ]
4 core 50 Sq mm. cable [ 8(b)/(xvi)/F-5 ]
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire as per GS. -- [ 17/C-2 ]
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required. [ 14(d)/C-2 ]
Supply & Delivery of Single LED Fitting (18 watt, 230 V AC, 50 Hz, 5700K CDL, THD< 10%, built in 2.5 KV SPD) with all accessories and 1 nos. LED Tube, as directed by EIC, Luminious efficacy > 105 & <120 Lumen/watt. The LED luminaves & accessories shall have BEE certification. (Make- Philips/Crompton/Wipro) [ NS ]
Dismantalling of the existing old electrical wiring from old existing MCB DBs etc. incl. existing old damaged fittings - fixtures etc. as per the direction of EIC. [ NS ]
Supply & Fixing Hylum sheet Meter Board on wall of size 2' x 1.5' by MS angle frame ( 50 mm x 50 mm ) incl. provision for fixing the 1 (One) nos. Three phase meter with supply & fixing 250/415 Volt, 3 Nos. 100 Amp Fuse Base and Bridge including 1 Nos. Neutral link incl. painting the wooden board as per direction of E.I.C. [ NS ]
Supply & Laing of Meter Loop connection incl. Supply & fixing 4 x 35 sqmm PVC single core multi stranded copper wire (RR/Polycab/Finolex) through PVC flexible pipe ( 3 meter. of Length of each Phase wire & Neutral wire i.e. 3 x 4 = 12 Mtr. of total length ) from Meter to Cut - Out and Cut - Out to Incoming of Main Switch with proper socketting by Pin/Ring type copper lugs of required sizes as per the direction of EIC. [ NS ]
Making holes on RCC ceiling 125 mm depth having dia of following sizes :125 mm depth, 50 mm dia [ 9(b)/E-3 ]
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. -- 50 mm dia [ 11(d)/F-6 ]
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil [ 1(a)/G-1 ]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI - Medium GI Pipe [ 2(a)/ G-1 ]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall as per GS. [ 4(b)/G-2 ]
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. Solid G.I. wire -- No. 4 SWG GI wire. [ 5(a)/(i)/G-2 ]
PART -- B ( S.I.T.C. WORK OF AC MACHINE ) Dismantling charges for the Old defective 1 (Single) phase Split type Room Air Conditioner machine (Make - Blue Star, Inverter type) including its Outdoor units with its Copper pipe, drain pipe, connection cable by Co's own tools & tackles as per the direction of E.I.C.
S & D of High-wall Split Air Conditioner having following specification: Cooling capacity -- 3.5 KW (Minimum) Minimum ISEER - 3.8, BEE level - 3 Star (min) [1st July 22 to 31st December 2024] IS Compliance - IS-1391(Part I & Part II) with all amendment Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 50ºC and above Power supply - 230V, 50Hz (±tolerance as per applicable standard),as directed by EIC. The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrile rubber insulation and warping tape - 3 mtr. (ii) Necessary 3/4 core copper cable (FRLS type- make: Finolex/Polycab/RR-Kabel)- 3 mtr. and with 25A plug top with indicator. (Anchor/NorthWest/Legrand/Havells). [Make- O.General/ Mitsubishi Electric / Zamils]. [ NS ]
S & D of High-wall Split Air Conditioner having following specification: Cooling capacity -- 5.2 KW (Minimum) Minimum ISEER - 3.8, BEE level - 3 Star (min) [1st July 22 to 31st December 2024] IS Compliance - IS-1391(Part I & Part II) with all amendment Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 50ºC and above Power supply - 230V, 50Hz (±tolerance as per applicable standard),as directed by EIC. The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrile rubber insulation and warping tape - 3 mtr. (ii) Necessary 3/4 core copper cable (FRLS type- make: Finolex/Polycab/RR-Kabel)- 3 mtr. and with 25A plug top with indicator. (Anchor/NorthWest/Legrand/Havells). [Make- O.General/ Mitsubishi Electric / Zamils]. [ NS ]
S & D of High-wall Split Air Conditioner having following specification: Cooling capacity -- 7.0 KW (Minimum) Minimum ISEER - 3.8, BEE level - 3 Star (min) [1st July 22 to 31st December 2024] IS Compliance - IS-1391(Part I & Part II) with all amendment Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 50ºC and above Power supply - 230V, 50Hz (±tolerance as per applicable standard),as directed by EIC. The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrile rubber insulation and warping tape - 3 mtr. (ii) Necessary 3/4 core copper cable (FRLS type- make: Finolex/Polycab/RR-Kabel)- 3 mtr. and with 25A plug top with indicator. (Anchor/NorthWest/Legrand/Havells). [Make- O.General/ Mitsubishi Electric / Zamils]. [ NS ]
Installation, Testing & Commissioning of Indoor & Outdoor unit of above HI Wall Split AC machine after making hole in wall etc. as per direction of EIC including supply of required Refrigant, S & F of necessary fixing arrangement for indoor and 40 x 40 x 5 mm. MS angle iron frame for outdoor unit ( or arrangement recomended by Manufacturer ), duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc. as per direction of EIC. [ NS ]
S & F of additional following items for length exceeding 3 mtr. For complete installation and commissioning of above AC machine. (i) Supply & Fixing of extra Refrigerant pipe (as requisite dia) with nitrite rubber insulation and wrapping tape (each mtr. Refrigerant pipe will include cost of 1 meter liquid pipe line and 1 mtr. gas pipe line of required dia and other accessories as required). [ NS ]
S & F of additional following items for length exceeding 3 mtr. For complete installation and commissioning of above AC machine. (i) 2.5 sqmm, 3/4 core copper cable (FRLS type, Make - Polycab/Finolex/RR Kabel). [ NS ]
Supply & Laying Soft Drawn PVC Drain pipe 19 mm. dia with proper supports & brackets as per direction of EIC. (Make - Suprime/Oriplast). [ NS ]
M/S R. K. ENTERPRISE
MODERN ELECTRIC
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .