Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical VILLAGE VILLAGE TEHSIL BAIJNATH DISTRICT KANGRA | MANDI | HIMACHAL PRADESH | 175013 | Accepted-Technical Fulfil eligibility Ceriteria |
| 2 | Accepted-Technical | Accepted-Technical Fulfil eligibility Ceriteria |
| 3 | Accepted-Technical V P O SEHAL TEHSIL BAIJNATH DISTT KANGRA H P | MANDI | HIMACHAL PRADESH | 175013 | Accepted-Technical Fulfil eligibility Ceriteria |
Tender Value
₹24.5 L
EMD Value
₹44,350
Closing Date
25 Jun 2026, 5:00 pmClosed
Executive Engineer
Jal Shakti Division Baijnath District Kangra HP
Construction of overhead storage tank in place of damaged tank under PDNA
2026_HPIPH_137055_1
2986-3036 dated 20-06-2026
Open Tender
Civil Works - Water Works
Item Rate
60 days
Chobin
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Executive Engineer
₹44,350
30 Jun 2026
20 Jun 2026
27 Jun 2026
20 Jun 2026
25 Jun 2026
20 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Designing, Constructing, Testing & Commissioning R.C.C. Elevated Circular Over head storage tanks as per capacity given below at various stages/sites including excavation in all kinds and types of strata, soil strata including dewatering in M30 design mix in foundation, walls, bottom slab , roof slab/dome with smooth finishing in 1:3 inside the tank, all alied Civil Works, Site development, cutting/excavation in all kinds of soils, C/o PCC/RCC Retaining walls, Breast walls, refilling and disposing of surplus stuff with in all leads and lifts, labour and material charges. The job also includes providing lowering, laying, erecting, hoisting and jointing of pipe assembly for inlet, outlet, overflow and scour pipeproper manifold at outlet including all fittings, bye pass arrangement consisting of GI / MS pipes special and valves of required classes and dia and all other accessories required such as SS ladders inside and MS outside ventilator with mosquito proof wire mesh,lightening arrester complete ,SFRC manhole covers including frames and covers (medium duty) with proper locking arrangement water level indicator, RCC frames for all valves ventilating shafts shall also be provided including all leads and lifts as per entire satisfaction of Engineer-in-Charge. The tanks shall be hydraulically tested for water tightness all works shall be conforming to relevant IS code with all latest revisions. The cost of valves & other accessories shall be included in the rates of tanks .The rates quoted by the contractor shall be for the complete work. All ancilliary works and accessories required to make the system fully functional shall be included in the cost of work. Nothing extra shall be paid on this account.The work shall include supplying of Five sets of structural design after testing the bearing capcity of soil and drawings, etc complete as directed by engineer in charge as per relevent data sheet and scope of work. complete with in all leads and lifts as per the direction and Entire to the Satisfaction of Engineer in Charge . Dia of pipe arrangement Inlet pipe - 100 mm dia Outlet pipe - 100 mm dia Scour pipe - 150 mm dia Overflow pipe - 100 mm dia | |||||
| 1.01 | C/O Over Head Storage Tank of Capacity 1,01,500 litr with 15 mtr Stag. Height. | 1,01,500 | Liters | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.12 MB
Form_6.pdf
Tender Documents • 0.26 MB
Form_8.pdf
Tender Documents • 0.81 MB
TC.pdf
Tender Documents • 0.06 MB
BOQ_202845.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .