Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAdmitted-Fee/PreQual/Technical/Finance | ₹5.2 L | L1 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | L2₹5.6 L+₹33,298 (6.35%)Admitted-Fee/PreQual/Technical/Finance | ₹5.6 L+₹33,298 (6.35%) | L2 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | INTIMATE REFRIGERATION AND AIR CONDITIONS L1 | Cool Palace Hoome Appliances L2 |
|---|---|---|---|---|---|
| 1.00Part-1 Air conditioning | |||||
| 1.00 | OD129630/2026-2027:SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 11 TR DUCTABLE SPLIT AIR
CONDITIONER UNIT CONSISTING OF CEILING
SUSPENDED DUCTED TYPE INDOOR UNIT, SINGLE
CIRCUIT OUT DOOR UNIT WITH EFFICIENT INVERTER
SCROLL COMPRESSOR CONFORMING TO IS 1391
(PART2/92) SUITABLE FOR OPERATING 415+-10% ,50
HZ THREE PHASE AC SUPPLY WITH POWER
CONSUMPTION NORMS AS SPECIFIED IN THE
STANDARDS OPERATING ON R-410A / R407C NON CFC
REFRIGERANT WITH CONDENSING AND EVAPORATING
UNITS OF COPPER TUBES CABLE FOR COOLING ,
DEHUMIDIFYING ,AIR CIRCULATING AND BIO FILTER
ACTIVATED CARBON CUM ELECTROSTATIC FILTER ETC
INCLUDING MICROPROCESSOR CONTROL WITH S
REMOTE CONTROL ETC. WITH ALL STANDARD
FITTINGS, SAFETY DEVICE LIKE HP/LP CUTOUT SINGLE
PHASE PREVENTER, OVERLOAD RELAYS,
MICROPROCESSOR CONTROL WITH DIGITAL DISPLAY
ETC AS REQUIRED.
(MAKE: LG/ PANASONIC/DIAKIN/MITSUBISHI/BLUESTAR) | 1 | no | 3,53,400 ₹3,53,400 Lowest | 3,80,400 ₹3,80,400 |
| 1.00 | 16.12.2.2:Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick | 5 | sqm | 1,470 ₹7,350 Lowest | 1,565 ₹7,825 |
| 1.00 | 16.15:Supplying & fixing of powder coated extruded aluminium Supply Air Grills with
aluminium volume control dampers as per specifications. | 2 | sqm | 10,700 ₹21,400 Lowest | 11,600 ₹23,200 |
| 1.00 | 16.16:Supplying & fixing of powder coated extruded aluminum Return Air Grills with louvers but without volume control dampers complete as required. | 2 | sqm | 6,950 ₹13,900 Lowest | 7,050 ₹14,100 |
| 1.00 | OD135718/2026-2027:Supplying and fixing of following thickness ACOUSTIC INSULATION
ON SUPPLY AIR DUCT LINING USING 10 MM CLASS 'O'
NITRILE RUBBER INSULATION as required.
Nitrile rubber insulation - 10 mm | 5 | metre | 1,265 ₹6,325 | 1,250 ₹6,250 Lowest |
| 1.01 | 16.23.1:Supplying and fixing of following thickness duly laminated aluminum foil of mat
finish closed cell Nitrile rubber (Class ""O"") insulation on existing duct after
applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50
mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as
per specifications and as required.
Nitrile rubber insulation - 25 mm | 5 | metre | 895 ₹4,475 Lowest | 905 ₹4,525 |
| 1.01 | OD135720/2026-2027:Heavy duct flexible double layer fire retardant canvas connection with rexin shall be provided at the outlet of dactable split/package unit and also for expansion joints. quoted price should be inclusive of all flanges, joints, supports etc. heavy duct flexible double layer fire retardant canvas connection with rexin shall be provided at the outlet of dactable split/package unit and also for expansion joints. quoted price should be inclusive of all flanges, joints, supports etc. | 1 | each | 3,750 ₹3,750 Lowest | 3,760 ₹3,760 |
| 1.01 | OD135723/2026-2027:Supply, and fixing of 22.2 mm hard drawn Copper Refrigerant Piping size in brazed construction having minimum 22 SWG gauge, including suitable rated elbows and other necessary fittings etc for interconnecting the air conditioning indoor and outdoor units and including insulated with minimum 19 mm thick insulation chemically cross linked closed cell Nitrile rubber tube insulation with mechanical protection coating/layer, duly clamped on wall /ceiling or and supported on GI perforated cable tray as per the drawing and site conditions for connection between outdoor and indoor units. | 10 | metre | 1,625 ₹16,250 Lowest | 1,650 ₹16,500 |
| 1.01 | OD135724/2026-2027:Supply, and fixing of 12.7 mm hard drawn Copper Refrigerant Piping size in brazed construction having minimum 22 SWG gauge, including suitable rated elbows and other necessary fittings etc for interconnecting the air conditioning indoor and outdoor units and including insulated with minimum 13 mm thick insulation chemically cross linked closed cell Nitrile rubber tube insulation with mechanical protection coating/layer, duly clamped on wall /ceiling or and supported on GI perforated cable tray as per the drawing and site conditions for connection between outdoor and indoor units. | 10 | metre | 988 ₹9,880 | 900 ₹9,000 Lowest |
Tender Value
₹5.3 L
EMD Value
₹13,131
Closing Date
14 Sept 2026, 6:00 pmClosed
AEE
PWD Electrical Sub Division Tvpm
GENERAL-Government Secretariat Thiruvananthapuram-Finance inspection wing south block third floor -Replacement of 11TR ductable unit with 4Nos 3TR split unit-Electrical AC Work
2026_PWD_868607_1
ESDT/ET-106/2026-27
Open Tender
Electrical Works
Item Rate
60 days
PWD Electrical Sub Division Tvpm
please refer tender documents
5 documents required · 5 mandatory
₹1,160
₹13,131
16 Sept 2026
9 Sept 2026
16 Sept 2026
9 Sept 2026
14 Sept 2026
9 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Part-1 Air conditioning | |||||
| 1.001 | OD129630/2026-2027:SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 11 TR DUCTABLE SPLIT AIR
CONDITIONER UNIT CONSISTING OF CEILING
SUSPENDED DUCTED TYPE INDOOR UNIT, SINGLE
CIRCUIT OUT DOOR UNIT WITH EFFICIENT INVERTER
SCROLL COMPRESSOR CONFORMING TO IS 1391
(PART2/92) SUITABLE FOR OPERATING 415+-10% ,50
HZ THREE PHASE AC SUPPLY WITH POWER
CONSUMPTION NORMS AS SPECIFIED IN THE
STANDARDS OPERATING ON R-410A / R407C NON CFC
REFRIGERANT WITH CONDENSING AND EVAPORATING
UNITS OF COPPER TUBES CABLE FOR COOLING ,
DEHUMIDIFYING ,AIR CIRCULATING AND BIO FILTER
ACTIVATED CARBON CUM ELECTROSTATIC FILTER ETC
INCLUDING MICROPROCESSOR CONTROL WITH S
REMOTE CONTROL ETC. WITH ALL STANDARD
FITTINGS, SAFETY DEVICE LIKE HP/LP CUTOUT SINGLE
PHASE PREVENTER, OVERLOAD RELAYS,
MICROPROCESSOR CONTROL WITH DIGITAL DISPLAY
ETC AS REQUIRED.
(MAKE: LG/ PANASONIC/DIAKIN/MITSUBISHI/BLUESTAR) | 1 | no | - | - |
| 1.002 | 16.12.2.2:Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick | 5 | sqm | - | - |
| 1.003 | 16.15:Supplying & fixing of powder coated extruded aluminium Supply Air Grills with
aluminium volume control dampers as per specifications. | 2 | sqm | - | - |
| 1.004 | 16.16:Supplying & fixing of powder coated extruded aluminum Return Air Grills with louvers but without volume control dampers complete as required. | 2 | sqm | - | - |
| 1.005 | OD135718/2026-2027:Supplying and fixing of following thickness ACOUSTIC INSULATION
ON SUPPLY AIR DUCT LINING USING 10 MM CLASS 'O'
NITRILE RUBBER INSULATION as required.
Nitrile rubber insulation - 10 mm | 5 | metre | - | - |
| 1.006 | 16.23.1:Supplying and fixing of following thickness duly laminated aluminum foil of mat
finish closed cell Nitrile rubber (Class ""O"") insulation on existing duct after
applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50
mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as
per specifications and as required.
Nitrile rubber insulation - 25 mm | 5 | metre | - | - |
| 1.007 | OD135720/2026-2027:Heavy duct flexible double layer fire retardant canvas connection with rexin shall be provided at the outlet of dactable split/package unit and also for expansion joints. quoted price should be inclusive of all flanges, joints, supports etc. heavy duct flexible double layer fire retardant canvas connection with rexin shall be provided at the outlet of dactable split/package unit and also for expansion joints. quoted price should be inclusive of all flanges, joints, supports etc. | 1 | each | - | - |
| 1.008 | OD135723/2026-2027:Supply, and fixing of 22.2 mm hard drawn Copper Refrigerant Piping size in brazed construction having minimum 22 SWG gauge, including suitable rated elbows and other necessary fittings etc for interconnecting the air conditioning indoor and outdoor units and including insulated with minimum 19 mm thick insulation chemically cross linked closed cell Nitrile rubber tube insulation with mechanical protection coating/layer, duly clamped on wall /ceiling or and supported on GI perforated cable tray as per the drawing and site conditions for connection between outdoor and indoor units. | 10 | metre | - | - |
| 1.009 | OD135724/2026-2027:Supply, and fixing of 12.7 mm hard drawn Copper Refrigerant Piping size in brazed construction having minimum 22 SWG gauge, including suitable rated elbows and other necessary fittings etc for interconnecting the air conditioning indoor and outdoor units and including insulated with minimum 13 mm thick insulation chemically cross linked closed cell Nitrile rubber tube insulation with mechanical protection coating/layer, duly clamped on wall /ceiling or and supported on GI perforated cable tray as per the drawing and site conditions for connection between outdoor and indoor units. | 10 | metre | - | - |
stage.html
html • 0.02 MB
finance_1471142.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
viewsbd.pdf
Additional Documents • 1.63 MB
Specificondtionsac-1.pdf
Additional Documents • 0.08 MB
BOQ_1471142.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .