Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹2.3 L+₹48,322 (26.3%)Rejected-AOC JAI DURGA CONSTRUCTION COMPANY SAILI BYEPASS ROAD PATHANKOT PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-AOC Other than lowest bidder |
Tender Value
₹1.8 L
EMD Value
₹3,600
Closing Date
15 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Paras Ram Puniya IDSE AGE I R and D Manali
AGE I R AND D MANALI PIN 175103 PH 01902255014
REPAIR REPLACEMENT OF HEATING UNIT HOT WATER TYPE WALL MOUNTED AND CONNECTED WORK AT HQ SASE MANALI
2020_MES_372797_2
AGE (I)/MNL-30/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Manali
As per NIT
5 documents required · 5 mandatory
₹300
AGE I R AND D MANALI
₹3,600
Yes
14 Dec 2020
1 Oct 2020
17 Oct 2020
1 Oct 2020
15 Oct 2020
3 Oct 2020
60 days
Amount
Comprehensive Maintenace of leakage of Secondary pipe Heating unit Motor 2 HP Make : Beacon. Complete all as specified and as directed by Engineer-in-Charge.
Repair/Maintenance of leakage of Water tank of heating unit made with Alluminium sheet. Complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing of Power contector MN 9W/MN on starter panel of Heating plant of Secondary pump Starter of sequence controller ISI marked. Make L & T/ABB Complete all as specified and as directed by Engineer-in-Charge.
Comprehensive maintenance to heat convector unit of capacity up to 6000 K cal/hrs wall mounted type including cleaning and maintenance of heating coil, aluminium blower lines bio filters etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for replacement of brass cock/flow valve 20 mm handle type ISI marked.Complete all as specified and as directed by Engineer-in-Charge.
Material and labour for fixing in replacement copper pipe of O.D. 1/2" including calding of thermocol and GI Sheet around the pipe in round shape with suitable fittings /supports of angle iron.Complete all as specified and as directed by Engineer-in-Charge.
Material and labour for fixing in replacement flare nut of size 1/2" inner dia.Complete all as specified and as directed by Engineer-in-Charge.
Labour only for flaring&soldering to copper pipe after providing flare nut and other accessories including connecting to in/out hot/cold water pipes of heat conventor unit residential wall mounted type. Complete all as specified and as directed by Engineer-in-Charge.
Comprehensive maintenance to heat convector unit of capacity 6000 K cal/hrs wall mounted type including cleaning and maintenance of heating coil, aluminium blower lines bio filters etc complete.Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement copper headers with brass flare nuts for in/out.Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of aluminium blower centrefugal DIDW.Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement G.I wire mesh filter/Bio filters.Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement flexible cord of twin core copper conductor PVC insulated PVC sheathed flexible round type complete with plug top 3 Pin 5 Amps 230 Volts including making connections complete all as specified and directed Note :- The single flexible cord comprising of length 2.25 Mtr with one Nos plug top of 3Pins 5Amps rating at one end considered as a each piece. Complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement heating unit hot water type wall mounted with powder coated casing of Nom. Capacity up to 4500 K cal/hrs 18000 BTU/hrs, heating coils 1/2" O.D. seamless copper pipe, electric aluminium fan blowers contrifugal DIDW coupled with blower motor 65watt, 930 RPM 3 speeds230 volts G.I wiremesh/bio filter etc complete all as specified and as directed by Engineer-in-Charge. Make :- SLIMLINE/AIREF/UNIVERSAL/DAIKIN.
Material and labour for fixing in replacement MS pipe of O.D 3/4" including calding of thermocol and GI Sheet around the pipe in round shape with suitable fittings/supports of angle iron.Complete all as specified and as directed by Engineer-in-Charge.
JAI DURGA CONSTRUCTION CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .