| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest rate qouted | |
| 2 | L2₹29.4 L+₹1.0 L (3.70%)Rejected-AOC 9 SHUBHASH BHAWAN RAJENDAR MARG MOUNT ABU 307 501 | MOUNT ABU | SIROHI | RAJASTHAN | 307501 | L2 | Rejected-AOC Not accepted since higher rate qouted | |
| 3 | L3₹29.6 L+₹1.2 L (4.41%)Rejected-AOC | L3 | Rejected-AOC Not accepted since higher rate qouted | |
| 4 | L4₹29.9 L+₹1.6 L (5.49%)Rejected-AOC | L4 | Rejected-AOC Not accepted since higher rate qouted | |
| 5 | L5₹30.0 L+₹1.7 L (5.98%)Rejected-AOC | L5 | Rejected-AOC Not accepted since higher rate qouted |
Tender Value
₹29.1 L
EMD Value
₹58,200
Closing Date
12 Feb 2020, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
SPECIAL REPAIRS TO BLDG NOS. P 81 AND P 153 INCL ROOF TREATMENT AT MIL STN GANDHINAGAR
2020_MES_317963_1
GE(A)/GNR/TOKEN/65 of 2019-20
Open Tender
Civil Works
Item Rate
180 days
MIL STN GANDHINAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE ARMY GANDHINAGAR
₹58,200
Yes
23 Apr 2020
24 Jan 2020
14 Feb 2020
24 Jan 2020
12 Feb 2020
6 Feb 2020
24 Jan 2020 - 5 Feb 2020
Amount
Removing rubbish to a distance exc. 1.5 Km but not exc. 5.0 KM out side MD land complete all as specified and directed.
M&L for plain cement concrete (1:5:10) type E-2 using 40 mm graded stone aggregate in filling into sunken floor and mass concrete complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for padestal/coping around poles, including necessary form work, finishing even and smooth without using extra cement, all as specified and directed.
M&L for 25mm thick precast cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in louvers or jallies (measured solid), including all mouldings but excluding frame, set in cement mortar (1:4) complete all as specified and directed.
M&L for cutting uneven surfaces of concrete & cutting reinforcement from drops of fins & facias (thickness not exceeding 50mm) using necessary scaffolding and making good the disturbed portion with 10mm thick rendering in CM 1:3 finished even and smooth without using extra cement etc. complete all as specifeid and directed.
Removing existing water proofing /black top treatment except concrete padding ruighing of concrete surface cleaning and washing down the surface with water and removing debrish/rubbish material to a distance exc. 1.5 Km but not exc. 5.0 Km out side Md land complete all as specified and directed.
M&L for screed bed 15mm thick on fair faces of concrete surface in cement mortar (1:3) mixed with using water proofing compound by weight of cement as per manufacturer instructions, finished even and smooth without using extra cement for laying APP membrane at non -accessible roof (mumty) complete all as specified and directed. Note:- Supply only liquid water proofing compound shall be measured and paid separately.
Preparation for water proofing treatment to roof slab by applying one coat of cold bituminous primer @ 0.30 litre/sqm and confirming to IS-3384, laying APP based polystr modified membrane reinforced non wooven polyster of 3.50 kg/sqm (minimum) 3mm thick with plain polythene finished and sealing all the overlap 75mm in length side and 100mm in width side of membrane by torching including applying one coat of bituminous aluminium paint over membrane all as specified and directed.
Supply only, liquid water proofing compound complete all as specified and directed.
M&L for Brick work with old size, sub class 'B' bricks, straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sqm each complete all as specified and directed.
S&F, factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site complete all as specified and directed.
S&F, solid PVC door frame of size 50mm x 47mm, made out of 5mm plain colour PVC sheet, reinforced with MS Square tube, supplying and fixing in opening as per specifications complete all as specified and directed.
S&F, in repair, aluminium anodised, barrel tower bolts of extruded section with length of bolt 150 mm and fixed complete all as specified and directed
S&F, butt hinges, medium weight, cold rolled, mild steel of size 100 mm complete all as specified and directed.
S&F, extruded aluminium alloy handles, fabricated type, anodised of size 150 mm complete all as specified and directed.
S&F, in repairs, brass, chromium plated tubular towel rail 20mm dia 60CM long between flanges complete all as specified and directed.
S&F factory made steel ventilators with top and side hung shutter including hinges, steel peg stay, glazing bars including applying one shop coat of red oxide primer all as specified and directed
S&F, Aluminium anodised doors/windows/ventilators with one or more rebates including joining cleat for fixing etc complete with frames, shutters and grills of size directed by Engineer-in-charge including handles, tower bolts, grills, etc complete all as specified and directed. Note:- Floor door spring, sheet glass, wire cloth, lock, etc shall be measured and paid seperately.
S&F, 0.63mm thick plain galvanized mild steel sheeting in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 all as sp[ecified and directed.
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3, all as specified and directed.
S&F, 20mm thick bituminus board strip 30cm width fixed bituminus crumple joint all as specified and directed.
S&F, in repairs, 18/19mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice laminations and other side balanceing white lamination, fixed with screws to timber frame work in cup boards, rebated or flat edged complete all as specified and directed.
M&L for 15 to 18mm thick black granite stone salb (table rubbed and polished) in cooking platform steps, jambs, pillars, window cills and like in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture and pigment to match with the shade of granite.
Rounding to edges of stone slabs one edge, such as steps, cooking plateform, and other similar situations complete all as specified and directed.
M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate in sub base to receive floor finishes complete all as specified and directed.
M&L for 40mm thick cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate as in roof padding laid in slope 1:30 including finishing surfaces fair and even complete all as specified and directed.
M&L, Non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular), area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set & jointed in net cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in CM 1:6 complete as specified and directed.
M&L for coloured non skid ceramic tiles, 7 to 8 mm thick, (square/rectangular), area of each tile exceeding 0.11 sq.m but not exceeding 0.18 sq.m in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including including screed bed or bedding layer of 15 mm thick cement mortar (1:6) complete all as specified and directed.
M&L for coloured non skid ceramic tiles, 7 to 8 mm thick, (square/rectangular), area of each tile exceeding 0.18 sq.m but not exceeding 0.38 sq.m in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of 15 mm thick cement mortar (1:6) complete all as specified and directed.
M&L for coloured glazed ceramic tiles of size 300 x 450 x 7mm thick on vertical surfaces such as skirting/dado, set and jointed in neat cement slurry and pointed in coloured cement to match over and including rendering 10mm thick in cement mortar (1:4)complete all as specified and directed.
M&L for coloured glazed ceramic tiles of size 300 x 450 x 7mm thick highlighter on vertical surface such as skirting/dado, set and jointed in neat cement slurry and pointed in colour cement to match laid over and including10 mm thick backing coat in CM 1;4 complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down cement plaster on brick or stone wall etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
M&L for rendering cement plaster 10mm thick in cement mortar (1:6) on brick work or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering cement plaster 5mm thick in cement mortar 1:4 on fair faces of concrete in ceilings, chajjas, fins facia etc. finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparing old plastered or un-plastered walls surfaces and applying one coats of white wash on walls complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of white cement as primer complete all as specified and directed.
M&L for preparation of old plastered surfaces of wall and applying one coat of cement base paint complete all as specified and directed.
M&L for preparing new plastered or un-plastered surfaces of walls and applying two coats of oil bound distemper over and including chalk whiting on walls complete all as specified and directed.
M&L for preparing new plastered or un-plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed.
M&L for preparing old plastered or un-plastered surfaces and applying one coat of white wash on ceiling complete all as specified and directed.
M&L for complete removal of existing treatment of wall including preparing preparation of surfaces and applying two coats of plastic emulsion paint with roller over and including two coat of Birla/JK white putty finished smooth to receive plastic paint complete all as specified and directed.
S&F, 5mm thick, black tinted glass panes fixed to aluminium doors/windows/vents with necessary rubber gaskets complete all as specified and directed.
M&L for 3mm thick sheet glass, ordinary quality and glazing with oil putty in square not exc. 0.5sq.m in each pane complete all as specified and directed.
M&L for preparation of new steel surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over existing shop coat of primer complete all as specified and directed.
Taking up or down steel tubing and connections for 15mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections for 20mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections for 25mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections for 40mm bore of pipe complete all as specified and directed.
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 15mm bore of pipe complete all as specified and directed.
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 20mm bore of pipe complete all as specified and directed.
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 25mm bore of pipe complete all as specified and directed.
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 40mm bore of pipe complete all as specified and directed.
Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 15mm bore of pipe complete all as specified and directed.
Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 20mm bore of pipe complete all as specified and directed.
Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 25mm bore of pipe complete all as specified and directed.
Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 40mm bore of pipe complete all as specified and directed.
S&F, 40mm bore ligh density polythene pipes (LDPE) of pressure rating 6 Kgf/Sqcm fixed complete all as specified and directed.
Hoisting, fixing in position and connecting, in repairs, 1000 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top) including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed.
Disconnecting, setting aside (or lowering if required) and Cleaning & removing all scale and dirt etc from HDPE water tanks of 1000 litres capacity (Tanks placed on top of roof) and from mouths of circulating pipes etc including washing the tank with bleaching powder and hoisting, reconnecting and re-fixing in position including writing the date of cleaning of tank with synthetic enamel (black/white) paint of size not less than 10cm of each letter complete, all as specified and directed.
S&F, CP Brass bib cock long body with capstan head handle screwed down suitable for 15mm bore fitting all as specified and directed.
S&F, in repair, concealed angular stop cock, size 15mm bore. Make : Jaguar (Code No. FUS-29053) or equivalent as approved by GE.
S&F, in repair, concealed stop cock, long body of size 15mm bore complete all as specified and directed.
Supply only PVC waste pipe 32mm bore of size 450mm to 600mm long complete all as specified and directed.
S&F, in repair, bib taps, cast copper alloy, fancy type, chromium plated, screwed down, screwed for iron pipe or brass ferrule of 15mm bore complete all as specified and directed.
Supply only pillar taps cast copper alloy with capstan head, chromium plated, screwed down high pressure, with or without lettered ‘hot’ or ‘cold’ with long screwed shanks and fly nuts, screwed for iron pipes 15mm bore complete all as specified and directed.
S&F, in repair, pillar taps cast copper alloy with capstan head, chromium plated, screwed down high pressure, with or without lettered ‘hot’ or ‘cold’ with long screwed shanks and fly nuts, screwed for iron pipes 15mm bore complete all as specified and directed.
S&F, in repairs, Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and directed for 25mm bores of pipe.
Supply only 32mm, waste fittings, brass chromium plated for glazed ware sink, basins, etc. with long screw shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S&F, in repair, 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight -210 Gms)
S&F, in repairs, Grating, square, 150mm size of PTMT (minimum weight 100gms) complete all as specified and directed.
S&F, in repair, only PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S&F, 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or floor complete all as specified and directed.
S&F, 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or floor complete all as specified and directed.
S&F, 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls including stack clamp complete all as specified and directed.
S&F, 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls including stack clamp complete all as specified and directed.
S&F, 75mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed.
S&F, 110mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed.
S&F, in repair, PVC (SWR) floor trap, with chromium plated grating including jointing with solvent cement, dia of outlet 75mm complete all as specified and directed.
S&F, in repair, vitreous china squatting pan, 'Orissa' pattern of size 580mm x 440mm with integral foot rest (excluding flushing cistern and flush pipe) including joining, filling and provision of cement concrete bedding 1:5:10, type E-1, using 20mm graded aggregate complete all as specified and directed.
S&F in repair, vitreous china bowl urinal flat back, of size 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing flush pipe grating and union for discharge pipe. (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
S&F, in repair, vitreous china wash basin, white, flat back of size 550mm x 400mm including brackets grouted in cement mortar 1:2 in wall complete all as specified and directed. Note :- Supply only pillar taps, waste fittings, PVC connection, PVC waste pipe shall be measured and paid separately.
S&F, in repair, brass chromium plated shower rose with or without swivel joint, 125mm size complete all as specified and directed.
Taking down steel window/ventilator including grills of any description, n. exc 1.5 Sqm each complete all as specified and directed
S&F, in repair, flush cock, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes or for unions of 25mm bore complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exc. 15cm thickness (below or above ground level) all as specified and directed.
Dismantling of cast iron, PVC or reinforced concrete drain pipes jointed in cement mortar for 110mm and 75mm bore of pipe from wall/floors etc complete all as specified and directed.
Taking down carefully unserviceable copper/aluminium point wiring (Light, fan, socket or power) complete including unserviceable fittings and fixtures such as switches, ceiling roses, pendents, regulators, sockets, lamp holders, brackets, except ceiling fittings, bulk head fittings, tube light fittings etc. and making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for wiring with and including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed for the following :-
(a) One light/fan point controlled by one switch
(c) One 3 pin, 5 Amps, socket outlet on the same board controlled by another switch.
(d) One multi pin 5 Amps, socket outlet on Independent board.
(e) One bell/ buzzer point controlled by one push buttons independent
M&L for wiring with and including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. for one 3 pin, 15 Amps socket outlet point on independent board complete all as specified and directed.
S&F, switch piano, flush button, single pole, one way, 5 Amps complete all as specified and directed
S&F, switch piano, flush button, single pole, one way 15 Amps complete all as specified and directed
S&F, socket outlet, 2 in 1, 3 pin, 15 Amps and 5 Amps flush type complete all as specified and directed
S&F, socket outlet, 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and directed
S&F, ceiling rose, 3 terminal , any shade, of PVC/Polycarbonate, isolated body complete all as specified and directed
S&F, ceiling fan regulators, Electronic type, AC, 230 Volts complete all as specified and directed.
M&L for refixing serviceable tube light fitting retrived from item No. 92 above complete all as specified and directed.
M&L for refixing serviceable fan regulators retrived from item No. 92 above complete all as specified and directed.
S&F, LED Tube light fitting, batten type, 20 watt (4 feet) for soft diffuser lighting and connecting up complete with white PVC insulated and PVC sheathed round flexible three core copper conductor cable of suitable size and testing on completion all as specified and directed as per Cat No. D532065 of Wipro or equivalent make as approved by GE from the makes specified under Appx 'C'.
Haritwal traders
Ramdev and Sons
nevi constructions
Choudhary Traders and Engineers
partechengineers
Shree Builders
divyarsh entrprise
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .