Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC | L1 | Accepted-AOC L1 AND REASONABLE | |
| 2 | L2₹5.2 L+₹37,740 (7.82%)Rejected-Finance 108 MARUTI COMPLEX NEAR DIGVIJAY TIN FACTORY MILE STONE BUILDING KV ROAD JAMNAGAR 361001 | JAMNAGAR | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹5.3 L+₹44,910 (9.31%)Rejected-Finance 30 DIGVIJAY PLOT RAVAL NIVAS JAMNAGAR GUJARAT 361 005 | JAMNAGAR | JAMNAGAR | GUJARAT | 361005 | L3 | Rejected-Finance NOT L1 | |
| 4 | L4₹5.7 L+₹87,200 (18.1%)Rejected-Finance 1ST COMPLEX RADHANPUR ROAD NEAR BYPASS CIRCLE OPP 1SQUARE MARKET MAHESANA GUJARAT 384002 | MAHESANA | GUJARAT | 384002 | L4 | Rejected-Finance NOT L1 |
Tender Value
₹4.5 L
EMD Value
₹9,000
Closing Date
17 Feb 2022, 6:00 pmClosed
OFFG GE A Jamnagar
INFANTRY LINES JAMNAGAR
REPAIR REPLACEMENT OF DG SET OF ELECTRIC SUPPLY INSTALLATION AND REPAIR TO LT PANEL AT INF LINE JAMNAGAR.
2021_MES_492958_3
8865
Open Tender
Electrical and Maintenance Works
Item Wise
334 days
Jamnagar
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹300
GE ARMY JAMNAGAR
₹9,000
9 Mar 2022
27 Jan 2022
19 Feb 2022
28 Jan 2022
17 Feb 2022
2 Feb 2022
Amount
Servicing and overhauling DG set by deputing authorised service representative to attend the DG set foillowing capacity carrying out scheduled preventive maintenance checks as specified on diesel generating set of any Make and to carryout the following checks, preventive repairs, all as specified and as directed by Eng-in-charge. 1 : Checking the fan belt and adjusting tension, Checking the fuel and oil filter, Checking the air filter including cleaning and refixing,Checking of FIP oil level,Tightening the base bolts and nuts,Checking the coupling bolts and adjustment checking the self starter and Dynamo,Checking the battery distilled water levels and topping upto the required level,Checking the panels (Manual as well as AMF) attached to the DG set for loose connections, defects if any in the panel Board and replacement of spares all as directed,Checking the anti vibration mounting and adjusting the bolt,checking the radiator and radiator hose and arresting leakage if any,Checking the engine oil level and topping upto the required level. 2:Checking of Control switches , MCCB's, contactors, multi display meters , Engine control unit . 3: Servicing of DG set alongwith connected Alternator and Panel Board of the Engine shall be carried out as directed by the Engineer-in-Charge and the Contractor shall carry out periodical inspections during the maintenenace period and shall be responsible for the smooth functioning of the DG set for Contract period and shall also attend all the maintenence / breakdown repairs as and when required in that period including attending and rectyfy any breakdown within 24 hrs of comunication,Failing to repair the DG set breakdown will attract penalty of Rs 1000/ 12hr. 4: Spare parts required for replacement during the maintenance period shall be measured and paid separately at supply & fix rates. 5: Minor spare parts other than those specified herein after but are mandatory for smoooth functioning of DG set is deemed to be included in the rate quoted for the item.
125 KVA DG set
62.5 KVA DG set
30 KVA DG set
Supply& Fix following filters with rubber 'O' ring suitable for 125 KVA DG Sets :-
(i) Fuel filter
(ii) Lube Oil filter
(v) Air filter (inner and outer)
Supply& Fix following filters with rubber 'O' ring suitable for 62.5 KVA DG Sets :-
(i) Fuel filter
(ii) Lube Oil filter
(v) Air filter (inner and outer)
Supply& Fix following filters with rubber 'O' ring suitable for 30 KVA DG Sets :-
(i) Fuel filter
(ii) Lube Oil filter
(v) Air filter (inner and outer)
Supply& Fix Anti vibration damper (Rubber) suitable for DG set of Capacity 125/62.5/30 KVA complete all as specified and directed by Engr-in-charge.
Supply& Fix fan belt suitable for DG set of Capacity 125/62.5/30 KVA complete all as specified and directed by Engr-in-charge.
S&F replacement of water tempreture gauge incl sensor & cable
S&F replacement of Coolent for radiators
S&F replacement of stop solonoid switch 12 volts as per sample
S&F replacement of automotive lithium grease in 1 kg sealed plastic container
S&F replacement of distilled water for battery
S&F replacement of water pump kit
S&F replacement of hydraulic diesel main pump
S&F replacement of battery lead set PVC insulation multistanded copper condutor 70 Square mm multistanded of 1.25 meter long each a duly fixed with brass clamp, copper lungs.
M&L for servicing of rotary pump for 125 KVA DG set.
Complete repair overhauling and calibration of FIP/PT pump fuel nozzel incl replacement of complete repair kit required for the DG Set of following capacities :-
Supply and Topping up of lubricant oil / engine oil of 15W40 grade for DG sets at various location under GE Army jamnagar complete all as specified and directed by Engr-in-charge.
Disconnecting radiator complete from DG Sets cleaning/ scraping of deposits manually from outside of the radiator, cleaning of all copper tubes of radiator with descaling solution from inside & outside with forced feed method & with water and air compressor (by using separate chemical pump water pump & air compressor ) repairing of all leakage with welding, brazing of copper tubes, cleaning of fins and replacement of gaskets etc for the following capacities of DG sets :-
(a) 62.5 KVA DG set
(b) 30 KVA DG set
Cleaning of fuel tank both internally and externally by removing all the dust / sediments etc.
(a) 125 KVA DG set
(b) 62.5 KVA DG set
(c) 30 KVA DG set
M&L for dismantaling and repairing of alternator engine mounted with replacement of rectifier, voltage regulator, diode plate, carbon brushes, pinion for 12V capacity. complete all as specified and as directed.
M&L for dismantaling and repairing of Self starter 12 volts( other moinor fault) for DG set by replacing thr defective worn out parts such as Armature diode plate, solonoid switch, carbon brushes, incl. testing complete all as specified and as directed.
Supply,install,test, commissioning of outdoor type floor mounted cubical type Main LT Distribution panel board, dust, varmin proof, IP54 made out of 3.15mm thick CRCA sheet powder coated enclosure of with angle iron frame 50 x 50 X 6mm and legs grouted (min 45 cm) in PCC 1:2:4 type B:1 (20 mm graded stone aggregate suitable for operation on 3 ph 4 wire 440 volts 50 Hz system with hinged panel doors on two sides with consisting of sufficient No of cable entry holes at bottom and top standard copper conductor PVC insulated cables of adequate size iincluding connection with LT armoured incoming and outgoing cables and incl required sizes of cables lugs including taking out oldunserviceable panel complete as under, all as specified & directed and consisting of following:-
(i) Aluminium bus bar rating 1.5 times of incomming MCCB rating for phase and neutral both - 04 Nos
(ii) Incomming MCCB of current rating 200 Amps with thermal release 4 pole 415 volts 25 KA repturing capacity - 01 Nos.
(iii) Out going MCCB of current rating 63 Amps with thermal release 4 pole 415 volts 10 KA repturing capacity - 05 Nos.
(vi) Set of phase indicator lamp R,Y,B with control MCB - 01 Set
Supply,install,test, commissioning of outdoor type floor mounted cubical type Main LT Distribution panel board, dust, varmin proof, IP54, made out of 3.15 mm thick CRCA sheet powder coated enclosure of with angle iron frame 50 x 50 X 6mm and legs grouted (min 45 cm) in PCC 1:2:4 type B:1 (20 mm graded stone aggregate iron frame duly powder coated.The LT panel shall be suitable for 3 phase 4 wire system, 440 volts, 50 Hz duly prewired withcopper bus bar for MCCB's and single core PVC insulated multistranded copper conductor 1100 volts grade of suitable size, connecting the cable with necessary cable Glands and cable alley, copper Lugs, proper arrangement of ventilation, including PCC work including taking out old unserviceable panel complete as under, all as specified & directed and consisting of following:-
(i) Aluminium bus bar rating 1.5 times of incomming MCCB rating for phase and neutral both - 04 Nos
(ii) Incomming MCCB of current rating 250 Amps with thermal release 4 pole 415 volts 25 KA repturing capacity - 01 Nos.
(iii) Out going MCCB of current rating 100 Amps with thermal release 4 pole 415 volts 25 KA repturing capacity - 01 Nos.
(vi) Set of phase indicator lamp R,Y,B with control MCB - 01 Set
Rameshwar Enterprise
Ravi enterprise
MADHAV ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .