| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 CrAccepted-AOC MIG 76 DR NO 39 33 146 2 3 MADHAVADHARA VUDA COLONY VISAKHAPATNAM 530 018 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530018 | ₹6.7 Cr | L1 | Accepted-AOC Being Lowest quoted Bidder |
| 2 | L2₹6.9 Cr+₹16.4 L (2.44%)Rejected-Finance | ₹6.9 Cr+₹16.4 L (2.44%) | L2 | Rejected-Finance Other than lowest Bidder |
| 3 | L3₹7.0 Cr+₹25.2 L (3.74%)Rejected-Finance FLAT NO 304 SN TOWERS JAGANNADHAPURAM JUNCTION AKKAYYAPALEM VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | ₹7.0 Cr+₹25.2 L (3.74%) | L3 | Rejected-Finance Other than lowest Bidder |
| 4 | L4₹7.4 Cr+₹62.2 L (9.24%)Rejected-Finance | ₹7.4 Cr+₹62.2 L (9.24%) | L4 | Rejected-Finance Other than lowest Bidder |
| 5 | L5₹7.4 Cr+₹68.8 L (10.2%)Rejected-Finance | ₹7.4 Cr+₹68.8 L (10.2%) | L5 | Rejected-Finance Other than lowest Bidder |
Tender Value
₹7.3 Cr
EMD Value
₹6.9 L
Closing Date
30 Jun 2020, 6:00 pmClosed
Chief Engineer Navy Visakhapatnam
Chief Engineer Navy Visakhapatnam Station Road Visakhapatnam 530004
PROVISION OF ACCOMMODATION FOR SINGLE IN LIVING INTERNATIONAL UNDER TRAINEES AT INS VISWAKARMA AT VISAKHAPATNAM
2019_MES_303213_3
CE(NAVY)/TOKEN NO 30 OF 2019-2020
Open Tender
Coal Works
Lump-sum
548 days
Visakhapatnam
As per tender details
9 documents required · 9 mandatory
₹3,000
Garrison Engineer(P) (N) Visakhapatnam
₹6.9 L
Yes
28 Aug 2020
5 Feb 2020
1 Jul 2020
5 Feb 2020
30 Jun 2020
25 Jun 2020
Amount
PHASE I Schedule "A" Part – I to Schedule "A" Part – XIV]: NOTE: Schedule "A" Part – I to Part – XIII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "BUILDINGS & STRUCTURES ", as listed in Schedule "A" Part – I on Serial Page No. 31.
Lumpsum price worked out by the contractor for "EARTH WORK SITE CLEARANCE & AREA DEVELOPMENT ", as listed in Schedule "A" Part – II on Serial Page No. 32 ( R)
Lumpsum price worked out by the contractor for " PILE FOUNDATION ", as listed in Schedule "A" Part – III on Serial Page No. 33( R)
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY ", as listed in Schedule "A" Part – IV on Serial Page No. 35 ( R)
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION, WATER COOLER, DEEP FREEZER, PVC CONDUIT & SOLAR HEATER ", as listed in Schedule "A" Part – V on Serial Page No. 37 ( R)
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY ", as listed in Schedule "A" Part – VI on Serial Page No. 38.
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION ", as listed in Schedule "A" Part – VII on Serial Page No. 39
Lumpsum price worked out by the contractor for "AREA DRAINAGE ", as listed in Schedule "A" Part – VIII on Serial Page No. 40
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL ", as listed in Schedule "A" Part – IX on Serial Page No. 42 ( R)
Lumpsum price worked out by the contractor for "ROAD / PATH / CULVERT / HARDSTANDING ", as listed in Schedule "A" Part – X on Serial Page No. 45( R)
Lumpsum price worked out by the contractor for "SECURITY WALL / FENCING / GATE", as listed in Schedule "A" Part – XI on Serial Page No. 47( R)
Lumpsum price worked out by the contractor for "LIGHTING PROTECTION ", as listed in Schedule "A" Part – XII on Serial Page No. 48.
Lumpsum price worked out by the contractor for "ARBORICULTURE", as listed in Schedule "A" Part – XIII on Serial Page No. 49.
Schedule "A" Part - XIV: MISCELLANEOUS ITEMS [PILE FOUNDATION, EXTERNAL WATER SUPPLY, INTERNAL ELECTRIFICATION, WATER COOLERS, DEEP FREEZER, REFRIGERATOR, EXTERNAL WATER SUPPLY,EXTERNAL ELECTRIFICATION, ROAD / PATH / CULVERT / HARDSTANDING, SEWAGE DISPOSAL AND ARBORICULTURE] [Serial Item No. 14 to 75 of BOQ] [To be quoted by the Tenderer in BOQ]
Loop in Loop out thermosplastic cable junction boxes of size 250 x 250 x 100 mm made out of 1.6 mm thick MS Sheet comprising with MCB SP 6 Amp and 4 Porcelain terminals as bus terminals for cable with necessary fixing arrangemets with cable glands, etc preparing the surface and appling two coats of synetic enamel paint over a coat of primer etc all as directed. (for Security Lights) Make: Hensel/Sintex
Supply, fabricate, install, test and commissioning LT Panel board confirming to CPRI approved manufacturer made out of CRCA sheet 3.15 mm thick Outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected on raised PCC platform with PCC 1:2:4 type B1 (20mm graded aggregate) of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material as per IS: 8623 Aluminium bus bar of 400 Amps rating with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 500 A capacity complete with powder coating, necessary internal electric wiring / connection as required and provision of the following : a) FOR INCOMING (i) LT 440 volts 3 phase, 4 wire 50 cycles, 36kA, Adjustable type MCCB of 125 Amp rated complete with overload protection, no volt thermal based release - 01 Nos. b) (FOR OUT GOING) (ii) LT 440 volts 3 phase, 4 wire 50 cycles, 36 kA, Adjustable type MCCB of 100 Amp rated complete with overload protection, no volt thermal based release.- 03 Nos. (iii) LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCB TPN of 32 Amp rated complete with overload protection, no volts thermal based release. - 01 Nos ( for Street Light) (iv) LED Indicating Lamps for ech phase with colour coed Red Yellow Blue for R, Y and B Phases - 01 set of three, (v) Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, power, energy, THD along with connected CTs Make: Schinder / L&T - 1 set of three
M&L for under ground PVC drainage pipe 160mm dia 4KN/Sq.m confirming to IS:15328-2003 single socketed in any length jointed with solvent cement, laid in trenches or floors etc all as specified (Make-SUDHAKAR SEALRING UG DRAINAGE PIPE SN-4/SDR 41 or equivalent
Concrete bed to drain pipes of size 450 mm bore packing under and haunching against the sides of pipes after they are laid and fitted in cement concrete, Type D2, 1:4:8, using 40mm graded stone aggregate complete all as specified and as directed.
Supply & Fix Integral LED street light Luminaire 72 Watts, comprising of epoxy powder coated, Pressure die cast aluminium housing enclosed with glass cover in frame, with suitable size of bracket, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete including installation and testing Make:- Bajaj cat part No. BRTFG 72W LED or eqvellent of Model in Philips/ CG / Havells
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
Supply and fix LT Sheet Metal Enclosure made out of CRCA sheet 3.15 mm thick Outdoor type totally enclosed with front opening, hinged door with projected on raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 with MCCB 125 Amps 4 Ploe Adjustable type for three phase and four wire LT AC, 50 Hz 415 V, LED indicating Lamps with powder coating, as required complete all as specified and directed
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure all as specified and directed.
Supply & planting carpet grass including preparation of ground up to 30cm deep and filling soft soil,cow dung and watering etc complete (loose soil and cow dung will measured separately).
Supply only approved loose soil best quality for plantation
Supply only approved vermi compost of the best quality
Supply only approved manure (cow dung) of the best quality
Supply and planting Gulmohar Plant (height of plant not less than45 cm above ground level) including prepration of ground up to 30cm deep and filling soft soil, cow dung vermi compost and watering etc. all as specified and directed
Supply and planting Royal plam (height of plant not less than45 cm above ground level) including prepration of ground up to 30cm deep and filling soft soil, cow dung vermi compost and watering etc. all as specified and directed
Supply, installation, commissioning of Voltage Stabilizer of capacity 2.0KVA for automatic operation, single phase naturally air colled indoor type & designed for input variation between 170 V to 250V with output voltage stabilized at 230V with accuracy +/- 2.5% complete all as specified and as directed.
Supply, installation, commissioning of Voltage Stabilizer of capacity 3.0KVA for automatic operation, single phase naturally air colled indoor type & designed for input variation between 170 V to 250V with output voltage stabilized at 230V with accuracy +/- 2.5% complete all as specified and as directed.
MCB DB, SPN, 6 Way, 415 Volts, sheet steel phospetised powder coated, Vertical, with DIN Channel, Double Door with 200 Amps rated bus bar 415V nautral link suitable for mounting MCBs, IP:43 protection complete all as specified and as directed.
MCCB DB, Double Door, Vertical Type, TPN, 4 Way, 415 Volts, sheet steel phospetised powder coated, IP:43 protection with DIN Channel, with 200 Amps rated bus bar nautral link suitable for mounting MCCB FP 100 Amp, 16 KA and out going circuit complete, fil empty with blank complete all as specified and as directed.
Time switches digital type, 415 V Single Phase of 20 Amp rating with contactor fitted inside steel enclosure including standard fixing arrangements complete all as specified and as directed (Make :- Legrand, Model No. 412631 or equivallent in Havells/ L&T / MDS /Simens)
MCB TPN 63 amps, 415 volts, 10 KA with all incoming / outgoing connections with proper size of copper lugs complete all as specified as directed
MCB TPN 100 amps, 415 volts, 10 KA with all incoming / outgoing connections with proper size of copper lugs complete all as specified as directed
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694, 1980 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified.
All as per Serial Item No. 36 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
All as per Serial Item No. 36 above but one 3/5 Pin Switch Socket Outlet 15 Amps on independent board, with 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694, 1980 and including 1100 Volts, FRLS grade, 2.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
All as per Serial Item No. 36 above but One Light point controlled by two two way switches complete all as specified.
Supply, installation, commis-sioning of refrigerator, electric driven double door single phase of capacity 324 litre BEE 5 star rated complete all as specified and as directed.
S&F Energy efficient LED T/L fitting 1 x 10 W, 230 volts, surface mounted type with extruded aluminium / CRCA housing with acrylic cover as diffuser and all accessories, mounting bracket, pre wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size and fixing arrangement complete all as specified and directed.
S&F Energy efficient LED T/L fitting 1 x 19/ 20 W , 230 volts, wall / surface mounted type with metalic channel and white reflactor complete with acrylic cover as diffuser and all accessories, mounting bracket, pre wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size and fixing arrangement complete all as specified and directed.
S&F Energy efficient LED mirror light fitting chrome colour metal & synthetic LED 10 W, 230 volts surface / wall mounted type complete with necessary diffuser and all accessories, mounting bracket etc. with pre wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size and fixing arrangement complete all as specified and directed
S&F Exhaust fan 380mm sweep or nearest size, metal body, complete with louvers suitable for operation on 230V AC, 50HZ AC Supply including provision of three core flexiable copper wireof size 23/0.0076from ceiling rose to exhaust fan fixed on wall making opening, fixing and making good the distrubered surfaces etc complete all as specified and as directed. Make:-Havells/Bajaj/CG/Orient.
S&F ceiling fans AC single phase 230 V of size 1200mm sweep with complete set with fixtures. BEE 5 star rating, metallic body including provision of three core flexiable copper wireof size 23/0.0076from ceiling rose to celing fan complete all as specified and directed. Make: Havells/Bajaj/CG/Orient
S&F Exhaust fan 250mm sweep or nearest size, Resign body, complete with louvers suitable for operation on 230V AC, 50HZ AC Supply including provision of three core flexiable copper wireof size 23/0.0076from ceiling rose to exhaust fan fixed on wall making opening, fixing and making good the distrubered surfaces etc complete all as specified and as directed. Make:-Havells/Bajaj/CG/Orient.
MCB single pole 6 to 30 amps, 240 volts, 10 KA, 'B' series with all incoming / outgoing connections with proper size of aluminium lugs complete all as specified as directed Note:(i) Cost of copper lugs shall be included in the unit rate.
MCB single pole & neutral 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of copper lugs complete all as specified as directed
S&F glossy white Co- Axial TV socket outlet complete all as specified and directed
Concealed Sub main wiring with 03 runs of 6.0 sqmm single core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, ISI Marked, drawing through and including PVC rigid conduit of suitable size complete with necessary fittings such as junction boxes couplings, unions bends reducers, inspection elbows, plugs etc complete all as specified and directed . ( Note: 3 runs of 6 Sqmm cable one run of conduit will be measured as one unit i.e RM).
Concealed Sub main wiring with 03 runs of 4.0 sqmm single core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, ISI Marked, drawing through and including PVC rigid conduit of suitable size complete with necessary fittings such as junction boxes couplings, unions bends reducers, inspection elbows, plugs etc complete all as specified and directed . ( Note: 3 runs of 4 Sqmm cable one run of conduit will be measured as one unit i.e RM).
Concealed Sub main wiring with 02 runs of 10.0 sqmm and 02 runs of 6.0 sqmm single core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, ISI Marked, drawing through and including PVC rigid conduit of suitable size complete with necessary fittings such as junction boxes couplings, unions bends reducers, inspection elbows, plugs etc complete all as specified and directed . ( Note: 2 runs of 10 Sqmm cable, 2 runs of 6.0 Sqmm cable and one run of conduit will be measured as one unit i.e RM).
Supply and fix telephone jack with shutter gloosy white RJ45 etc complete all as specified and directeed.
Cutting existing steel tubing of 100 dia for alterations or additions necessarily done in position without taking down, dewatering and inserting Tee 100x100X50 mm dia with collars and required specials complete all as specified and directed.
Supply, fixing, commissioning and testing sprinklers complete all as specified and directed.
Boring for bored cast-in-situ piles 600 mm dia in any type of soil / clay / soft rock except hard rock by Hydraulic system of boring methodand and getting out and disposal of spoil out side MD land complete all as specified and directed.
Boring for bored cast-in-situ piles 450 mm dia in any type of soil / clay / soft rock except hard rock by Hydraulic system of boring methodand and getting out and disposal of spoil out side MD land complete all as specified and directed.
Boring for bored cast-in-situ piles 600 mm dia in hard rock & Factured rock by Hydraulic system of boring methodand and getting out and disposal of spoil out side MD land complete all as specified and directed.
Boring for bored cast-in-situ piles 450 mm dia in hard rock & Factured rock by Hydraulic system of boring methodand and getting out and disposal of spoil to a distance not exc 10KM out side MD land complete all as specified and directed.
Chipping out pile up to cutoff level incl disposal up to distance of 50m all as specified and directed.
Carrying out initial load test on 600 mm dia pile as per IS 2911 Part IV, complete all as specified and directed.
Carrying out initial load test on 450 mm dia pile as per IS 2911 Part IV, complete all as specified and directed.
Carrying out routine load test on 600 mm dia pile as per IS 2911 Part IV, complete all as specified and directed.
Carrying out routine load test on 450 mm dia pile as per IS 2911 Part IV, complete all as specified and directed.
Carrying out lateral test on 600mm dia piles all as per IS-2911 Part - IV complete all as specified and as directed.
Carrying out lateral test on 450mm dia piles all as per IS-2911 Part - IV complete all as specified and as directed.
Carrying out pull out test on 600mm dia piles all as per IS-2911 Part - IV complete all as specified and as directed.
Carrying out pull out test on 450mm dia piles all as per IS-2911 Part - IV complete all as specified and as directed.
Carrying out low strain integrity test on bored cast in situ piles of any dia including analysing the results as per ASTM D 5882 complete all as specified and as directed.
MS Pipe liner fabricated out of 6mm thick plain MS Plate confirming to Fe-410S by welding the joints lengthening wherever required, providing stiffener, lifting hooks including all T&P as required, shifting the same from positions to positions as required, driving in true vertical alignment in position to the reqd level for piles complete all as specified and directed Note : MS Pipe liner shall be casted as mentioned in drawing. How ever for payment purpose, the depth of pile liner shall be measured up to cut off level only irrespective of the depth provide for retaining concrete / Bentonite slurry. The unit rate/lumsum price quoted shall be deemed to include for the same.
Granular Sub base(GSB) with grading V of 150mm thick compacted thickness(laid in two layers of 75mm each, compacted separately) confirming to grading as specified, spread, rolled and consolidated to required gradient and camber complete using necessary mechanical paver / grader and vibratory soil compacter of capacity 8-10 ton all as specified and as directed. (a) Pavement shall be made for solid quantity arrived after consolidation. (b) Compaction of granual sub base filing shall be carried out under optimum moisture condition to achieve 98.50 modified density. (c) Curing shall be carried out as per IRC recommendations. (d) Before execution of this item the approved material obtained fron outside MD land shall be tested/checked for suitability to use. (e) The lead/Royality involved is to be ascertained by the contractor before quoting his tender and no extra payment/Adjustment for increased in lead or rate of royality due to whatever reason shall be admissible on his account. (f) Contractor shall use Vibratory earth compactor in lieu of power roller to achieve 98.00% MDD at OMC without any extra cost and the method of compaction to be adopted as per recommendation of agency reporting MDD at OMC. (g) GSB shall be as per MORTH specification as detailed in Particular Specification.
Wet Mix Macadam of 250mm thick (complacted thickness) laid in three layers compacted separately with coarse aggregate of specified grade spread rolled and consolidated to required gradient and camber complete using mechanical paver / grader and Pandom using modified proctor density determination method as per IS code on prepared GSB surface complete all as specified and as directed. Note: 1. The rate quoted shall be for 250mm compacted thickness. 2. Each layer shall be rolled separately.
S& F 160mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified.
S&F 15 mm bore two way bib taps long body cast copper alloy chromium plated fancy type with capstan heads, screwed down for size complete all as specified.
S&F 15mm bore Health faucet, cast copper alloy, chromium plated fancy type including stainless steel flexible house of 1.2 mtr & wall hook complete all as specified.
PHASE II : SCHEDULE A PART XV. (MAINTENANCE OF ARBORICULTURE)
Material and labour for maintenance including watering and fertilization of all the grass/plants/tress by weeding hosing saucer meldingonce inevery 15 days, planting new plants / grass spices and height with out any extra cost to the department for a period of six months complete all as specified and directed.
S V S ENTERPRISES
MURALI KRISHNA ASSOCIATES
anjaliinfratech
Venkateswara Electricals
VENKATA SAI SRINIVASA CONSTRUCTIONS PRIVATE LIMITED
CH.VEERARAGHAVULU CONSTRUCTION PVT LTD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .