Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹40.6 L+₹2.0 L (5.23%)Rejected-AOC 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹40.8 L+₹2.2 L (5.73%)Rejected-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹41.9 L+₹3.2 L (8.40%)Rejected-AOC 13 THAKKAR PLOT DEEPAK KUNJ PORBANDAR 360575 | PORBANDAR | GUJARAT | 360575 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹43.4 L+₹4.8 L (12.5%)Rejected-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
3 Oct 2022, 6:00 pmClosed
GE I CG Porbandar
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
REPAIR MAINTENANCE REPLACEMENT OF INTERNAL AND EXTERNAL ELECTRIC SUPPLY WATER SUPPLY DG SET AC AND OTHER MISC ITEMS AT ICGS OKHA UNDER GE I CG PORBANDAR
2022_MES_551376_1
8767
Open Tender
Civil Works
Item Rate
Okha
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
Yes
GE I CG PORBANDAR
₹76,000
Yes
25 Oct 2022
12 Sept 2022
4 Oct 2022
12 Sept 2022
3 Oct 2022
28 Sept 2022
Amount
SCHEDULE 'A'
Cutting & removing existing joint and supply, jointing and testing outdoor type Heat hrinkable straight through cable joint including all material and accessories suitable for XLPE cable of 11000 volts grade , complete all as specified and directed. Make:- RPG/RAYCHEM/DENSON.
3 core X 95 Sqmm
3 core X 185 Sqmm
Cutting & removing existing joint and supply, jointing and testing indoor type heat shrinkable end termination cable joint including all material and accessories suitable for 3 core X 95 Sqmm XLPE cable of 11000 volts grade, complete all as specified and directed by Engr-in-Charge. Make:- RPG/RAYCHEM/DENSON/3M
3 core X 95 Sqmm
3 core X 185 Sqmm
M&L for Dehydration/centrifuging of tranformer oil minimum 3 cycles to achieve dielectric strength 50 KV in 2.5mm gap electrode with centrifuging machine at site and testing of transformer oil before and after de hydration complete all as specified and as directed.
S&F Transformer oil having di-electric strength of 60 KV as per IS complete for top up/ replacement all as specified and as directed by Engr-in-Charge. (Oil should be supplied in sealed barrel of Power/Transol brand) Note: oil shall be filled in the transformers/stabilizers to be repaired or installed at site at different locations.
M&L for servicing and renewal/replacement of defective parts of oil type transformer capacity 400 KVA 11/.433 kV Indoor/out door type of any make by disconnecting of HT bus bar connection and providing electric power to user by alternative arrangement, opening of doors etc complete cleaning of the inside compartment,core and coils by vacuum cleaner incl lead supports,tap changer terminal boards,bushing and other insulated surface be wiped clean with dry cloth and all connections must be checked for tightening after cleaning up to the satisfaction of Engr-in- Charge the transformer must be meggred and connecting all connection and necessary testing complete with under mentioned scope of work. defective part measured and paid under respective item howver fixing charges included. (i) Cleaning of transformer from inside/out side. (ii) Testing the transformer for IR values (iii) Checking/servicing/calibration of WTI for healthiness (iv) Magnetic balance test (v) IR Value check before and after the work (vi) Voltage ratio test at 440 V. (vii) DC logic test (viii) Commissioning of transformer after completion of work. Note :- (i) Test results obtained shall be recorded and produced to the Engr-in- Charge. (ii) All measuring equipments and T&P required shall be arranged by the contractor. (iii) Any item/activity not listed/covered here above and required during/completing the overhauling work will have to be arranged by contractor himself. (iv) The rate quoted shall be deemed to include for disconnection of transformer HV/LV terminations for testing work and re-connections after completion of repair work.
Comperehensive maintenance of HT panel/RMU, detection of defective components, replacement of wornout parts and servicing/cleaning of mechanical components through authorised service centre of VCB manufacturer /OEM or skilled VCB repairing agency, re-insertion oftrolly in HT panel, testing for smooth complete all as specified and directed by Engr-in-charge. Note: Worn out parts shall be measured & paid seperately under respective items.
Supply only following parts/items for HT panel/RMU complete all as specified and directed
Motor cut off Limit switch Make: BCH/L&T/C&S
Closing coil 24V DC Assembly
Shunt trip coil 24V DC
Supply and fix in replacement of HT 11 KV outdoor type Air break switch GOD Gang operated device triple pole,with drop out fuse mechanically operated, mounted on insulator (insulators) and steel frame, with operating mechanism and opeating rod of GI pipe 25mm bore medium grade with necessary clamps to be operated from GL 11KV grade worked from ground level, for current rating 200 Amps complete with joints to match complete all as specified and directed.
Material and labour porcelain aerial fuses suitable for line wire, with brass contact bolts and nuts of maximum 3 mm dia in line wire and 30 Amps max all as specified and directed
Comprehensive maintenance and repair of APFC panel by replacement of worn out spare parts and cleaning of the serviceable contactors and tightening/ checking of all internal electrical connections and accessories to maintain PF not less than 0.99 by adjusting/ calibrating the APFC relay of any type, complete all as specified and directed by Engr-in-Charge. Note: Defective parts if any will be measured and paid seprately
Supply only following items/part for APFC Panel
Heavy duty gas filled Capacitor 5 KVAR,440V, 3phase, 50 Hz. Make: L&T Seriest No LTCCN or equivalent in Havells/C&S
Heavy duty gas filled Capacitor 10 KVAR,440V, 3phase, 50 Hz. Make: L&T Series No LTCCN or equivalent in Havells/C&S
Heavy duty gas filled Capacitor 3 KVAR,440V, 3phase, 50 Hz. Make: L&T Seriest No LTCCN or equivalent in Havells/C&S
8 Steps APFC Relay Make: L&T/C&S/Siemens
Servicing of Servo Stabilizer oil cooled automatic type of capacity 100 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel level, supply system, Lubrication system, cooling system, rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge. (a) Lubrication oil. (b) 3 Phase Digital display system (c) Dimmer 40 A rewinding 3 Nos (d) Carbon viper assembly 3 Nos
Material and labour for painting of the tranformer 400 KVA complete by removing old paint by scrapping and providing spray painting with synthetic enamel paint of approved make duly marking/writing MES/SM No. all as directed by Engr-in-Charge
M&L for applying two coat of epoxy paint on LT Panels of any size ,including preparation of rusted surface of poles by means of sand paper/scrubing of dust etc and apply one coat of epoxy based primer before painting complete all as specified and directed, Note: Minor repair/ replacement of hinges suitable for screw fastners and fixed in original position deemed to be included in unit rate.
Supply and fix in replacement of time switches 415 V, three Phase integrated model with max Load 5-8 KW of 20 Amp rating with suitable MCBs and contactor fitted inside enclosure confirming to protection of IP66 with Hinged Lid all as specified and directed.
M&L preparing old rusted surface of steel tubular pole by means of sand paper/scrubing of dust etc and apply one coat of red oxide on surface of Metalic poles and applying two coats of silver paint on Pole and numbering of poles with synthetic enamel paint white in 100 mm high letters over 150x150 mm black base complete all as spd and as directed by Engineer-in-Charge.
M&L preparing old rusted surface of PCC pole by means of sand paper/scrubing of dust etc and apply one coat of primer on surface of poles and applying two coats of OBD paint on Pole and numbering of poles with synthetic enamel paint white in 100 mm high letters over 150x150 mm black base complete all as spd and as directed by Engineer-in-Charge.
Supply and fix in replacement thermoplastic cable junction box for street lights of size 205 x 255 x 112mm including bus bar/terminal for cable connection with IP-66 protection complete all as specified and directed Make : Hensel Cat No.DK 2525 G or its equivalent in Legrand/sintex
M&L for bore Earthing 150 mm bore for earthing with galvanised steel pipe electrode, 40mm bore, medium grade, 3 metres length,top edge of GI pipe 15 cm above GL , connected with earthing lead of 25X4 mm GI strip to the earthing test point and filling of charcol dust , salt etc and testing on completion, complete all as specified and directed by Engr-in-Charge. Note: IR Value should be less than 5 Ohms.
Material & Labour Cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (heat shrinkable) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of following sizes-Make-Denson/Siemen, , complete all as specified and directed by Engr-in-Charge.
25 Sqmm to 50 sq mm
70 Sqmm to 150 sqmm
150 Sqmm to 240 sqmm
Taking out UNSV LT UG cables of any sizes from trenches all as spd.
Supply & Lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross-sectional area. Make: Polycab/ Asian/ Gloster, complete all as specified and directed by Engr-in-Charge.
120 Sqmm 3.5 Core
95 Sqmm 3.5 Core
35 Sqmm 4 Core
16 Sqmm 4 Core
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick , complete all as specified and directed.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point , complete all as specified and directed.
M&L for cutting existing road/hard standing not exc 45 x 45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:2:4; including removal of surplase soil complete all as specified and directed.
Material and Labour for DWC pipe laying in trenches/ under floor/on walls for protection of UG cables of following sizes, complete with coupler and connected accessories all as specified and directed by Engr-in-Charge. Note: (i) Cutting of floor/ road and making good with PCC deemed to be included in item rate Make: Rex/Poly/Geminie
Supply and fix in replacement MCCB 4 pole 100 Amps of Breaking capacity 25KA. Make- Legrand /ABB /L&T, complete all as specified and directed by Engr-in-Charge. Note- Cost of retrofitting of existing panel shall be deemed to be included in the quoted rate.
Supply and fix in replacement MCCB 4 pole 63 Amps of Breaking capacity 16KA. Make- Legrand /ABB /L&T, complete all as specified and directed by Engr-in-Charge. Note- Cost of retrofitting of existing panel shall be deemed to be included in the quoted rate.
Supply and fix in replacement MCCB 4 pole 200 Amps of Breaking capacity 25KA. Make- Legrand /ABB /L&T, complete all as specified and directed by Engr-in-Charge. Note- Cost of retrofitting of existing panel shall be deemed to be included in the quoted rate.
Supply and fix in replacement Alumium lugs long barrel of size 95 sqmm complete all as specified and directed. Make: Dowells or equivalent
Supply and fix in replacement Alumium lugs of size 50 sqmm complete all as specified and directed. Make: Dowells or equivalent
Supply and fix in replacement Alumium lugs of size 16 to 35 sqmm complete all as specified and directed. Make: Dowells or equivalent
Servicing of DG set ('C' Check) of Cap 100/125 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect if any and including replacement of following, complete all as specified and directed. (a) Lub oil filter. (b) Lubrication oil. (c) Fuel filter. (d) Coolent top up. Make of DG set: Ashok Leyland/ Kirloskar Note: Defective parts if any other than listed at (a) to (d) above will be measured and paid separately
Supply only parts/ Items of DG set 100/125 KVA (Make : Ashok Leyland/ Kirloskar)
Oil Filter
Fuel Filter
Air Filter
Fuel Filter Assembly
Coolant
Engine Oil
Battery Terminals
Hose Pipe Set
AVR as per existing Specification
Servicing of DG set ('C' Check) of Cap 20/25/30 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect if any and including replacement of following, complete all as specified and directed . (a) Lub oil filter. (b) Lubrication oil. (c) Fuel filter. (d) Coolent top up. Make of DG set: Ashok Leyland/ Kirloskar Note: Defective parts if any other than listed at (a) to (d) above will be measured and paid separately
Supply only parts/ Items of DG set 20/25/30 KVA (Make : Ashok Leyland/ Kirloskar)
Oil Filter
Fuel Filter
Air Filter
Fuel Filter Assembly
Coolant
Engine Oil
Battery Terminals
Hose Pipe Set
AVR as per existing Specification
Servicing/Calibration of old AMF Panel and rectification of defect if and and including Repair/ Replacement of Unserviceable items all as specified and directed.
AMF controller as per existing Make
Relay Card Start/Stop
Relay Card Contactor
4ST relay
Wiring as per existing specification
Comprehensive maintenance, servicing and testing of AC of any make complete for during contract period by cleaning cooling coil, condenser fins, blowing off dust from machines & air filters, checking and de-carbonizing , oiling, greasing of blower motor, checking and removing any vibration , and testing at site all as directed by Engineer-in-Charge. Note:(a) Cost of any minor nature repair / items such as nuts ,bolts,washers,screws,rubber mounting pads of compressor,top up of gas, etc and labour required for removing / refixing after repair of equipment is deemed to be included in the unit rate of this items. (b) Wornout compressure , blower motor, replacement if required shall be measured and paid seperately.
Split type air conditioners of capacity 1.5 ton
Split type air conditioners of capacity 2.0 ton
M&L for detecting the cause of leakage in any type/capacity of 1.5 tonne AC and ensuring the complete system leak proof and charging of refrigerant gas with appropriate quantity as directed by EIC including testing for smooth functioning complete all as specified and as directed. Notes :- (i) Dismantling of unserviceable compressor , cost of refrigarent gas and re-installation of serviceable compressor after repairing are deeemed to be included in the quoted rates .
All as per item no 87.00 but of capacity 2 tonne .
M&L for refrigerant tubing for Discharge/liquid tube copper pipe of size including 3/8 inches OD with insulation packing all as per site requirement and as directed.
M&L for refrigerant tubing for suction tube copper pipe of size including 5/8 inches OD with insulation packing all as per site requirement and as directed.
Supply only spare part for Split type AC cap 1.5/2.0 TR of make as per AC
Compressor Heremetically sealed Rotary Type for 1.5 TR AC
Compressor Heremetically sealed Rotary Type for 2.0 TR AC
Blower Motor / condensor Motor for 1.5/2.0 TR AC
Outdoor Unit without compressor for 1.5/2.0 TR AC
Indoor Unit with remote 1.5/2.0 TR AC
PCB for Outdoor/Indoor of make as per existing of any capacity
Taking down carefully burnt out aluminium/copper circuit wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, etc to be measured and paid for seprately) making good to the disturbed surfaces of walls ceilings and floors etc , complete all as specified and directed.
Taking down submain wiring of size 2.5 and 4.0 sqmm complete and making good to disturbed surfaces of wall ceiling and floor etc complete all as specified and directed
M&L for point wiring with PVC insulated and unsheathed cable 1.5 Sqmm (Nominal area) ISI marked stranded copper conductor single core in existing conduit including 1.5 Sqmm PVC insulated and unsheathed stranded copper cable to common earth and connecting to earth dolly including colour coding of cable shall be Phase-Red, Neutral- Black and Earth- Green complete all as specified and as directed by Engineer-in-Charge for the following. Make of wire: Finolex/RR Cables/Havells
One light/fan point controlled by one, one way switch
One bell point controlled by push button on the same board with other switch.
One 5 pin socket outlet 5/6 amps on the same board.
One 5 pin socket oulet 5/6 amps on independent board..
M&L for point wiring complete with stranded copper conductor 2.5 sqmm single core (nominal area) PVC insulated and unsheathed cable 1100 volts grade drawn in existing conduit including single core stranded copper conductor connected PVC unsheathed cable 2.5 sqmm as earth wire to the common earth and connecting to earth dolly all as specified for one 6 pin socket outlet two in one 16/6 amps on an independent board , complete all as specified and directed. Make of wire :Finolex/RR Cables/Havells
M&L for submain wiring with two single core 2.5 sq mm stranded copper conductor PVC insulated and unsheathed cable ISI marked in PVC conduit heavy duty of dia 25mm fixed in wall/on surface or ceiling for sub main wiring alongwith including 2.5 Sqmm PVC insulated unsheathed copper conductor ISI marked as earth wire complete including taking down of worn old wiring , complete all as specified and directed by Engr-in-Charge. Make: RR cables/HPL/ Havells/ KEI.
M&L for submain wiring with two single core 4 sqmm stranded copper conductor PVC insulated and unsheathed cable ISI marked in PVC conduit heavy duty of dia 25mm fixed in wall/on surface or ceiling for sub main wiring alongwith including 2.5 Sqmm PVC insulated unsheathed copper conductor ISI marked as earth wire complete including taking down of worn old , complete all as specified and directed by Engr-in-Charge. Make: RR cables/HPL/ Havells/ KEI.
S&F in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 8 way type, complete all as specified and directed by Engr-in-Charge. Make Hager/ L&T/ Legrand.
Dismantling electric/water connection and taking down of storage type water heater, servicing, cleaning of inner tank etc. at site and replacement of burnout parts etc. and refixing in situ , complete all as specified and directed by Engr-in-Charge. Note- worn out parts shall be measured as separately.
Supply only spare parts for Geyser complete all as specified and directed
Heating element 1.5 KW with rubber gasket .
Thermostat as per sample/suitable to 25 Ltrs capacity ISI marked.
Hot/Cold water connection pipe 450 mm length.
S&F in replacement Casing and caping size 25mmX16mm , complete all as specified and directed by Engr-in-Charge.
S&F in replacement uPVC conduit ofsize 25mm, FRLS complete all as specified and directed by Engr-in-Charge.
Taking down ceiling fan 1200mm/1400mm sweep and Exhaust fan upto 250mm sweep complete servicing, repair of fan motor and replacement of worn out parts such as bearing and hanging of ceiling fan/Exhaust fan in situ , complete all as specified and directed by Engr-in-Charge. Note: (i) Rewinding of fan motor will be measured and paid separately.
Dismantling of fan (1200mm sweep) motor, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material and reassembling , complete all as specified and directed by Engr-in-Charge..
Dismantling of Exhaust fan 250mm sweep motor, cutting of burnt winding of rotor and rewinding with same gauge copper winding wire with insulated material and reassembling , complete all as specified and directed.
Dismantling of BLDC fan (1200mm sweep) motor, taking out unserviceable PCB and replace with new PCB as per existing make and reassembling , complete all as specified and directed.
S&F in repair 10 Watt LED batten luminaire suitable for wall mounting of capacity 10 Watt 2 feet long with voltage range 100-240 volts and inbuilt protection,complete all as specified and directed by Engr-in-Charge. Make: Wipro(LL20-111-XXX-65-NE3) or equivalent in Philips/Crompton Greaves.
S&F in repair 20 Watt LED luminaire, nominal lumen output 2000 lm, extruded aluminum housing, IP20,voltage range 140-270 volts PF>0.9, wall mounted, complete all as specified and directed. Make: WIPRO (LL20-281-XXX-65AL1) or equivalent in Philips/Crompton Greaves
S&F in replacement LED Luminaires recessed mounted down lighter 32/36 watt 5700K system efficiency not less than 100lm/watt,thd<10% single phase including connecting cable from ceiling rose to terminal block of luminaires complete all as specified and as directed by Engineer-in-Charge. Make :Wipro (LD06-221-XXX-57-XX) or equivalent in Philips/Crompton Greaves
S&F in replacementr 9 W 3000 colour Lumens LED spot light with multiple beam tilting angles, no UV radiation and dimmable ballast Make : Wipro Cat part No LD98-131-024-40-XX or equivalent in Philips/Crompton Greaves
S&F in Replacement of u/s light any type LED flood light 150 Watt LM6 high pressure die cast aluminium housing, IP 66, Nominal Lumen output 14000 lm, Colour temprature 5700K, THD<10%, PF>0.95, Operating Voltage 140-270V AC, 50HZ , complete all as specified and directed by Engr-in-Charge. Make: Wipro cat part No-LF20-192-060-57-BS or equivalent in Philips/Crompton Greaves
S&F in Replacement of u/s LED street light of capacity 70 Watt, LM6 high pressure die cast aluminium housing, IP 66 protection , THD<20%, PF>0.95, Operating Voltage 140-270V AC, 50HZ, complete all as specified and directed by Engr-in-Charge. Make: Wipro Cat Part No LR02-671-XXX-57-G3 or equivalent in Philips/Crompton Greaves
S&F in Replacement of u/s LED building security light of capacity 30 watt , LM6 high pressure die cast aluminium housing, IP 66 protection , THD<20%, PF>0.95, Operating Voltage 140-270V AC, 50HZ, complete all as specified and directed by Engr-in-Charge. Make: Wipro cat part No-LR02-331-XXX-57-XX or equivalent in Philips/Crompton Greaves
S&F LED Bollard light Cool white 6500 K of wattage 11 watt with integrated mounting base plate and driver complete with including PCC (1:2:4) foundation of suitable size for mounting of light fitting including mounting pole with accessories not less than 1.2m height complete all as specified and directed. Make : Wipro Cat No. LB14-131-XXX-65-08 or equivalent in Philips
S&F in replacement LED Bollard Light Cool White of wattage 11 Watt 6500 K with with integrated mounting base plate and driver complete with housing dark grey RAL 7043 IP 65 protection, Resistant to corrosion and Better optics for uniform distribution including PCC (1:2:4) foundation of suitable size for mounting of light fitting complete all as specified and directed. Make: Wipro Cat No: LB13-131-XXX-65-08 or equivalent in Philips
S&F in repair square shape slim recessed mounted LED down light of capacity 33 Watt (2ft x 2ft) with die cast housing finished in white powder coating complete all accessories as specified and directed . Make : Wipro, Madel: Verge, Cat No: LM29-451-XXX-57-XX or its equivalent in Philips
S&F in repair square shape slim recessed mounted LED down light of capacity 18 Watt with die cast housing finished in white powder coating complete all accessories as specified and directed . Make : Philips, Cat No: DN097B LED10S-6500 PSU WH or its equivalent in Philips
S&F in repair round shape slim recessed mounted LED down light of capacity 18 Watt with die cast housing finished in white powder coating complete all accessories as specified and directed . Make : Philips, Cat No: DN296B LED20S-6500 PSU WH or its equivalent in Philips
S&F in repair Slim 07 Watt round LED panel light luminaire, nominal lumen output 800 lm, extruded aluminum housing, IP20,voltage range 140-270 volts PF>0.9, wall mounted, complete all as specified and directed by Engr-in-Charge. Make: Philips Cat No: SM250C LED7S- 6500 PSU WH or equivalent in Wipro/CG/Syska
Taking down the old and rusted GI bracket and supply fixing GI bracket of 40mm dia duly painted with two coat of supper enamelled paint over a coat of red oxide including suitable clamps nuts bolts and washers etc .
S&F in replacement LED driver for 12/22 watt LED light fittings confirming to rating input 180-270 V AC complete all as specified and directed. Make : as per existing
Supply and fix in replacement following items for maintenance of Internal Electrification , complete all as specified and directed by Engr-in-Charge.
Lamp holder plug for Batten fitting.
Bell push, flush type 5 Amp.
Electric bell Ding Dong type , 230 Volts Single pole.
Socket Outlet 2 in 1, 3 pin, 6A
Switch socket combination, 6 Amps flush type.
Switch socket combination, 16 Amps flush type.
2.5 mfd Capacitor
Stepped type electronic fan regulator
Modular switch 1 way 6 amp 1 module
Modular switch 1 way 16 amp 1 module
Modular socket 6A-2/3 pin combined, 2 module
Modular socket 6A/16A-2/3 pin combined, 2 module
White cover plate with frame,2 module
White cover plate with frame,3 module
White cover plate with frame,4 module
White cover plate with frame,6 module
White cover plate with frame,8 module
Modular Metal/polycarbonate Flush Box, 2 module
Modular Metal/polycarbonate Flush Box, 3 module
Modular Metal/polycarbonate Flush Box, 4 module
Modular Metal/polycarbonate Flush Box, 6 module
Modular Metal/polycarbonate Flush Box, 8 module
S&F top plug 5 Amp complete all as specified and directed.
S&F top plug 15 Amp complete all as specified and directed.
Ceiling rose surface type bakelite / PVC three terminal 65 x 50mm.
Supply and fix in replacment MCB of following rating Make legrand/Siemens/L&T, complete all as specified and directed by Engr-in-Charge.
6-32 Amp SP ,240 volt 'C' series, 10 KA
32 Amp SPN ,240 volt 'C' series, 10 KA
32 Amp TPN,440 volt 'C' series, 10 KA
63 Amp TPN,440 volt 'C' series, 10 KA
’Comprehensive maintenance / servicing and repair of search light system by replacement of worn out parts, and cleaning of the serviceable contactors and tightening/ checking of all internal electrical connections and accessories/ relay/ single phase preventor/ motors etc. all as specified and directed by engineer-in-charge
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of following sizes
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified as per site requirement complete of sizes of nominal dia:-
Supplying and laying of CPVC Schedule 80 pipes & plain CPVC Schedule 80 fittings in trenches complete all as specified as per site requirement complete of sizes of nominal dia:-
S & F CPVC Gate /ball valves as per requirement of the site of the following
Taking down and Supply, lay and joint in replacement in trenches 150mm bore, ductile iron (DI) pipe Class "K-7" , of standard length spigot and socketed end push type joint with rubber gasket as jointing material, internal cement mortar coating and external surface with bituminous paint of size150 mm (6") dia ISI including specials all as spd and directed.
M & L bends (any type, radius and angle) tapers any type (straight bend, increasing, decreasing or double socked etc) tee pieces , single branch, junction, double branch, cross ( all sockets or socket and spigot) collars, caps plugs suitable for the pipe upto 300 mm bore.
Dismantling the centrifugal Pump 15 HP including disconnecting suction and delivery etc and reassembling after replacement of necessary spares including greasing and painting of 2 coats of synthetic enamel paint using spray machine complete all as specified and as directed by Engr in charge. [NOTE: Replacemnt of worn out spares will be measured and paid separately].
Supply and replace following worn out spares of Centrifugal/monoblock pump sets.
Bearing as per existing Size suitable for 15 HP motor
Rubber bush for coupling as per existing size for 15 HP motor
Gland packing for 15 HP motor
Taking down electric motor 3 phase, 415 Volt capacity 15 HP, incoming disconnection electric connections, dismantling slots, taking out burnt windings and rewinding the motor with super enameled copper wire as per existing size including insulating material and varnishing,greasing, painting with super enameled paint as per colour coad assembling the motor after rewinding and mounting at its own position, replacing the old nut, bolts and testing all as directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out Soft/ Loose soil complete all as specified and directed
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick complete all as specified and directed
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
Construction of brick masonry valve pit complete including necessary excavation and earth work complete all as specified with internal dimension 150x150x110cm (type 'B') including MS sheet cover 3mm thick welded with hinges on angle iron frame 50x50x6mm with hold fast grouted in 100mm thick PCC (1:2:4) type B-1 coping on top of brick wall including necessary locking arrangement complete all as specified and directed by Engineer-in-Charge.
Taking out unserviceable foot valve 80/100 mm dia from the UG sump and S & F new foot valve 80 mm dia ball type incl rubber gasket, bolts, buts complete all as directed.
Supply & fix of sluice valves flanged type class PN 1.6 complete all as specified and directed
100 mm dia bore
150 mm dia bore
Supply and fix in replacement Automatic star delta starter for 15/20 Hp centrifugal mono block pump set, 415 V 50 Hz three phase as per existing specification all as specified and directed.
Supply and fix in replacement of following spares for RO water Purifier 50 LPH
Sediment/Carbon Filter
Membrane
Filter box with candle
fakhrie apostrical
K K Construction Co
OM ENGINEERING
JAMNAGAR ELECTRIC AND MACHINERY CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .