| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC H NO 19 6 243 1 NGO S COLONY SHIVNAGAR NORTH BIDAR 585 401 | BIDAR | BIDAR | KARNATAKA | 585401 | L1 | Accepted-AOC Due to L1 | |
| 2 | L2₹15.6 L+₹89,876 (6.13%)Rejected-Finance | L2 | Rejected-Finance Due to L2 | |
| 3 | L3₹16.8 L+₹2.2 L (14.8%)Rejected-Finance 19 1 69 3 PLOT NO 17 NEW ADARSH COLONY BIDAR 585 401 | BIDAR | KARNATAKA | 585401 | L3 | Rejected-Finance Due to L3 |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
16 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bidar
GE AF Bidar, Naubad road, Bidar, Karnataka 585401
ADDN AND ALTN TO DESK ROOM AT DSS, HOTS A AND CERTAIN REVENUE WORK AT AF STN BIDAR
2020_MES_370082_1
8229/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Bidar
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) Bidar
₹39,000
Yes
1 Oct 2020
18 Aug 2020
17 Sept 2020
18 Aug 2020
16 Sept 2020
2 Sept 2020
60 days
Amount
Surface excavation not exc. 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil all as specified.
Excavating in trenches, in hard/desne soil n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick each, in soil, complete all as specified.
Removing excavated soil to a distance not exceeding 50m and depositing where directed, at a level n.exc 1.5m above the starting point, complete all as specified.
Hard core with broken stone boulders of guage n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
Plain cement concrete 1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate) as in foundation, filling, etc complete all as specified.
Plain cement concrete 1:3:6 type C-2 (using 40 mm graded mechanically crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified.
40mm thick damp proof course to horizontal surface in cement concrete 1:2:4, type B0, (using 12.5 mm graded mechanically crushed stone aggregate) mixed with WPC @ 3% by weight of cement or as per manufacturer’s instructions, including form work, complete all as specified. Note: Supply only WPC will be measured and paid separately.
Earth filling under floor incl spreading levelling in layers n.exc 25cm thick well ramming incl watering complete with soil obtained from excavation all as specified and directed.
Cutting openings, through brick walls for door, window and other openings or enlarging existing openings, converting window into door openings, built in cement mortar etc and removing rubbish.
Pre-cast cement concrete block masonry with solid blocks type B-1 (1:2:4) (using 20 mm graded mechanically crushed stone aggregate) exc. 10 cm in width and setting in cement mortar 1:4, complete all as specified
15mm thick cement plaster in cement mortar 1:4 on fair face of wall finished even and smooth without using extra cement all as specified and directed.
15mm thick cement plaster in cement mortar 1:6 on fair face of wall finished even and smooth without using extra cement all as specified and directed.
Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over 1mm thick wall care putty on plastered surface for neat and smooth finishing complete all as specified.
Preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer/white wash complete all as specified.
Complete removal of existing treatment on wall and applying two coats of oil emulsion distemper over 1mm thick wall care putty on plastered surface for neat and smooth finishing complete all as specified and directed.
Complete removal of existing treatment and applying two coats of cement base paint on wall complete all as specified and directed.
Premium quality, vitrified ceramic tiles, light shade of size 600 x 600 x 10 mm thick as in floor, set and jointed in neat cement slurry @ 3.00 kg/Sqm and pointed in white or coloured cement to match the surface over and including cement screed bed 15mm thick in cement mortar (1:4) complete, all as specified.
Premium quality, vitrified ceramic tiles, light shade of size 600 x 150 x 10mm thick on vertical faces of walls over and including 10mm thick rough finished plaster in cement mortar (1:4) set, jointed in neat cement slurry and pointed in coloured cement to match, complete all as specified.
Anodised, powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
Anodised powder coated aluminium door shutters, with aluminium sections weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading, screws etc. complete all as specified.
Anodised powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.), hinges type B-21 100mm long (2 nos.) suitable handle (1 no.) complete all as specified.
Anodised noise proof aluminium window fixed, fixed type without sash bar, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified. Note for item Nos. 21, 22 and 23: Glass and other filling material in panels shall be measured and paid for separately.
6mm thick toughned glass of any size fixed to aluminium/wooden joinery, complete all as specified and directed.
Anodised aluminium grill of 7.00mmx3mm thick section, square / rectangular/ triangular/ circular shape aperture not exc 7 cm in length or width fixed with H or F channel all as specified and directed.
Galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanized wire staple and including fixing with beads supplied with joinery when fixed in panels of joinery complete fixed in repairs all as specified.
Sheet glass 4mm thick, ordinary quality and glazing with oil putty or in wooden beads in square n.exc 0.5 Sqm each pane complete all as specified.
Providing reinforced cement concrete 1:2:4 type B-1, using 20mm graded mechanically crushed stone aggregate, in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves, complete all as specified.
Providing reinforced cement concrete 1:2:4 type B-1, using 20mm graded mechanically crushed stone aggregate, in Beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified.
Reinforcement for concrete with mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
Reinforcement for concrete with mild steel TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
Form work to soffits or suspended slab such as roof slab, floor slab, landings and similar works not exceeding 200mm thick horizontal or sloping all as specified and as directed.
Form work to sides and soffits of floor or roof beams, etc., all as specified and as directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizintal or sloping and similar work exc 10cm but n exc 20cm wide for fair finished surface.
Aluminum snap grid frame work of size 605x605 mm for false ceiling comprising 40x25x2mm aluminum angle weight not less than 0.36kg/Rm, fixed all along the wall at ends and with aluminium main and cross section of size 36.5mmx25mmx 1.4mm weighing not less than 0.24 kg / Rm respectively including aluminium cleats, bolts, nuts and washers as per manufacturer’s instructions, complete all as specified.
12mm thick, Perforated particle board/tiles for insulation and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid as in ceiling complete all as specified.
50mm thick, PCC 1:3:6 type C-1 (using 20 mm graded mechanically crushed stone aggregate) as in plinth protection/PCC path, and paving, finished the surface even and fair, laid in alternate bays, complete all as specified.
Taking down wooden chowkats or frames area not exceeding 1.50 Sqm (w/o taking off shutters from frames), including cutting holes for taking out existing hold fasts and making good in cement mortar (1:3) or PCC 1:2:4 type B1, complete all as specified and as directed.
Taking down wooden chowkats or frames area exceeding 1.50 Sqm and not exceeding 4.00 Sqm (w/o taking off shutters from frames), including cutting holes for taking out existing hold fasts and making good in cement mortar (1:3) or PCC 1:2:4 type B1, complete all as specified and directed.
100 mm thick plain cement concrete 1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate), as in sub base, complete all as specified.
PCC coloured, rubber moulded, interlocking designer paver blocks in any and shape, confirming to IS-15658-2006 of 60mm thickness, M-35 grade in path, hardstanding, etc laid over and including 50mm thickness screed or bedding layer of sand, complete all as specified.
Stainless steel type curtain rod with siutable size of bracket with finacals 22 to 25mm dia as per existing complete fixed in repairs all as specified and directed.
Dismantling of existing roof treatment consisting of screed, tar felts, etc and removal of dismantled materials complete as directed
Spreading/brushing neat cement slurry with 3.00 kg/sqm on concrete surface all as specified.
PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate mixed with WPC as per manufacturers instructions, laid to achieve the slop required, with minimum thickness of 25mm, consolidated and finished even and fair all as specified and as directed.
15mm thick screed bed on concrete surface in cement mortar 1:3 on roof mixed with water proofing compound finished even and smooth without using extra cement all as specified and directed. Note for item Nos. 45 and 46: Supply only water proofing compound will be measured and paid separately.
Water proofing treatment on horizontal or verticle surface with provision with oil bound bitumen primer 0.40Kg/Sqm, APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) all as detailed specification, applying a coat of blown grade hot bitumen 85/25 or 90/15, 1.20 kg/sqm and finished with solar reflective bituminous aluminium paint @ 100gm/sqm all as specified and directed.
Supply only water proofing compound
Excavation in trenches for foundation not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in soft/loose soil, complete all as specified and directed by Engr-in-charge.
Precast cement concrete block masonry walling with solid blocks type C1 1:3:6 (20 mm graded stone aggraegate) setting in CM (1:4) exc 10 cm in width complete all as specified and directed.
Plain cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping including weathering, slightly rounded or chamfered angles and including necessary form work complete all as specified and directed.
Rendering 15mm thick in CM 1:4 finished even and smooth without using extra cement, mixed with WPC on concrete/brick masonry surfaces complete all as specified and directed. Note: Supply only of water proofing compound will be measured and paid separately.
200mm dia bore reinforced concrete pipes with collars, class NP2 laid and jointed complete, all as specified and directed.
75mm dia PVC (SWR) Pipes Single socketed in any length with rubber ring joints fixed in drain walls all as specified and as directed.
50mm thick plain cement concrete type B-1, 1:2:4 (20mm graded stone aggregate), surface finished even and smooth without using extra cement.
Glass dividing strips 3mm thick, 38 mm width inserted in position.
Anodised aluminium door shutters, aluminium section weighing not less than 1.10 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each shutter, hinges, anodised aluminum snap beading screws etc. complete all as specified.
Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing not less than 1.10 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings in each shutter such as peg stays 150mm long (1 no.) hinges type B-21, 100mm long (2 nos.) suitable handle (2nos.) complete all as specified. Note for item Nos. 57 and 58: Glass and other filling material in panels shall be measured and paid for separately.
Sheet glass, 5.5mm thick ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane.
Solar control film 50 micron reflective type sticked to glass panes as per instructions of manufacturers, all as specified and directed.
Mortice lock, vertical type, size 100 mm brass 4 lever.
Aluminium (Die Cast) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 kg and fixed.
12mm thick Prelaminated particle board, one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work for shutters of ward robes, cabinet etc. all as specified and directed.
18/19mm thick Prelaminated particle board, one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work for shutters of ward robes, cabinet etc. all as specified and directed.
Second class hardwood plain solid straight chowkats and frames wrought, framed rebated on the solid rounded or chamfered put together with glue pinned at joints all as specified and as directed.
Point wiring with 2 runs of 1.5 sqmm single core PVC insulated FRLS unsheathed cable 1100 volts grade multistranded copper conductor drawn into and including suitable size of PVC conduit concealed in wall, roof etc. and including provision of one run of PVC insulated 1.5 sqmm copper conductor for earth continuity and connected to common earth dolly and pressed steel terminal box made out of 1.6 mm thick MS sheet concealed in wall and laminated sheet cover of 3 mm thick on top for housing the switches, fan regulator, socket outlets etc complete for One light point controlled by one switch.
All as per item No.66 here in before but using 2.5 sqmm copper conductor with 2.5 sqmm PVC insulated, single core cable for earth continuity conductor.
Switch piano, flush type single pole, one way 5 Amp complete all as specified as directed
Ceiling rose, 3 phase PVC/polycarbonate, isolated body
Switch socket combination 2 in 1, 3 pin 5 amps and 15 amps 230 volts flush type universal complete all as specified as directed
Sub main wiring complete with 2 runs of 6 sqmm single core PVC insulated unsheathed FRLS cable, 1100 volts grade, multi stranded copper conductor drawn through and including suitable size of PVC conduit pipe and accessories concealed to surface / wall roof etc with one run PVC insulated 6sqmm FRLS cable , copper condutor for earth continuity conductor all as specified and as directed. Note: 2 runs 6sqmm single core copper conductor, one run of 6sqmm copper conductor earth wire and PVC conduit and its accesories will be measured as one unit .
Hi wall Split Air Conditioner units complete with 1st fill of ecofriendly refrigerant gas indoor/ outdoor units with cordless remote control unit and within built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 1.5 Ton including suitable anchor bracket factory made, available along with AC unit, scotch screws with nuts and bolts etc for fixing of outdoor unit complete all as directed. Note: Cost of refrigerant pipes from indoor to outdoor unit alongwith burntil rubber insulation, drain pipes of suitable size and length shall be deemed to be included in the quoted rate.
Chemical earthing complete with copper earth plate electrode 90 cm x 60 cm x 5 mm thick buried directly in ground earth pit not less than 5 m deep below normal ground level and complete size of pit 1.6 m x1.6 mx5 m earth plate conneted to copper strip of size 32x6 mm by brazing only earth strip protected with light grade GI pipe 40 mm dia from copper earth plate electrode upto and including the earth test terminal point made up of gunmetal phosphorus bronze of size 75x75x25 mm including 25 mm bore water pipe medium grade GI tubing including GI funnel wire mesh, Alternative 5 layers of charcoal(250 kg) and salt crystal 200 kg and two top inch layers with back filling compond 200 kg including excavation in strata refilling with black cotton soil above the magnesium sulphate and removal of the excavated soil and depositing at the place where directed, PCC pit in PCC (1:3:6) type C1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars including MS angle iron frame of 40 x 40 x 3 mm watering the earth pit to achieve the earth resistance not more than 0 1 Ohm including testing all as specified and directed. Note: 1. Earth conductor from earth plate to equipment upto 7.5 M length deemed to be included in the rate quoted by the contractor and beyond 7.5 M will be measured and paid under the respective item of the schedule. 2. Cost of excavation, returning and filling, earth work required based on the nature of eath pit for satisfactory completion of job deemed to be inclusive in the unit rate.
Single pointed air termination aluminium rod, 12 mm dia, 300 mm long all as specified and as directed
Aluminium strip 25 x 3 .15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground level all as specified and as directed.
Test point terminal block made up of gun metal or phohporous bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia, 25 mm long hexagonal head screw all as specified and as directed.
MCB DB SPN 12 way metallic double door IP42 Protection 240V, AC 50Hz for MCB double pole as incomer and double pole / single pole MCB as outgoing with tinned copper bus bar of rated 200 Amps neutral link earth link complete all as specified and as directed.
MCB SPN 63 Amp 240 V 50Hz,10KA C series including making electrical connection with the help of Lugs/thimbles all as specified and as directed.
MCB SP 6- 32 Amps 240 V 50Hz ,10KA C series including making electrical connection with the help of Lugs/thimbles all as specified and as directed.
2 feet x 2 feet recess mounted square LED panel die cast body with premium diffuser to ensure glare free and even distribution of light white powder coated CRCA with full window acrylic diffuser 34 W with latest LED technology and efficient optics ensuring perfectly uniform illumination and unparallel light distribution voltage 150 - 270V temp range 0-50degree C,Temp -6500 K. Make: Havels Cat No :PLUTONE02X2PLR34WLED857S or its equivalent in Wipro /Bajaj/CG
Single pole and neutral enclosure with a two pin and earth plug socket complete with one single pole MCB20 Amps 240 volts .
Wall mounted fan of size 400mm elegantly designed fan base in round shape and pull cord control for speed and oscillation, all as specified and as directed. Make: Havels Platina HS or its equivalent in Wipro /Bajaj
Porcelain insulators suitable for copper strip 20 x 3.15 mm / Aluminium 25 x 3.15 mm on roof /on wall etc with necessary fixing arrangement all as specified and as directed.
4 feet LED surface and wall mounted 22W LED with latest LED technology and efficient optics ensureing perfectly uniform illumination and unparellel light distribution voltage 150-270 temp range 0-50 degree C Colour Temp -6500K all as specified and as directed.
Siddique constructions
famous construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .