Loading…
Loading…
Tender Value
₹12.9 L
EMD Value
₹12,900
Closing Date
13 Mar 2026, 6:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
The Chief Officer, Dahod Nagarpalika, Dahod
BID DOCUMENTS FOR PROVIDING, SUPPLYING AND ERECTING SPLIT TYPE INVERTER AIR CONDITIONING SYSTEM WITH REQUIRE ACESSORIES AT DAHOD NAGAR PALIKA, DAHOD.VYAVSAYVERA 50 PERCENTAGE GRANT 2025-26.
283117
Vyavsayvera 50 percentage 2025-26
Open
Electronics Equipment
Dahod
14 documents required · 14 mandatory
₹1,062
The Chief Officer, Dahod Municipality, Dahod
₹12,900
5 Mar 2026
5 Mar 2026
5 Mar 2026
13 Mar 2026
5 Mar 2026
SR NO. QTY ITEM UNIT RATE AMOUNT
Providing and erecting Inverter based approved make split air-
conditioning unit consisting of condensing unit with variable speed fan
motor, inverter type hermetically sealed rotary compressor with
accessories etc. duly connected separately erected evaporating unit and
1.0 1.00 blower motor with its accessories by means of extra supplied proper Nos. 50830.00
insulated copper tubing,drain PVC pipes suitable for ( cost includes 15A
plug top & Remote Control & MS Stand) (1)For 3 Star Rating of current
year (B) for 1.5 ton capacity (CARRIER/VOLTAS)
2.0 8.00 (C) for 1.7 to 2 ton capacity (CARRIER/VOLTAS) Nos. 58780.00
Supply, Installation, testing and commissioning including
vaccumiazation and Nitrogen testing of following nominal sizes of
soft/hard drawn copper refrigerant piping for VRV system, complete
with fittings, with suitable adjustable ring type hanger supports,
jointing/brazing including accessories, insulated with XPLE Class-0
3.0 335.00 tubular insulation/with Class-0 closed cell elastometric nitrile rubber Mtr. 784.00
tubular sleeves sections of specified thickness as given below for
Suction and Liquid lines, all accessories as per specifications etc with
necessary refrigerant joint as required :(B) 9.5 mm dia (OD) (Soft
drawn) with tube thickness 1.2 mm with 19 mm thick insulation
4.0 40.00 Supplying colourless non inflammable refrigerant Gas R-410 Kg 1663.00
carry out RCC Core cutting- up to 100 mm dia./300mm thick
5.0 17.00 Wall/beam/slab with providing PVC pipe of 3 mm thick inside and JOB 2864.00
necessary finishing on both ends of wall .
Providing and erecting ISI marked PVC insulated PVC Sheathed Flat
6.0 350.00 flexible Submersible copper cable approved make of following Size. Mtr. 223.00
(B) 3 Core x 2.5 Sq. mm.
Supplying and installing MS angle , powder coated / Painted standard
type of wall/floor stand mount for outdoor unit of split AC of following
7.0 9.00 capacity, erected with necessary hardware materials as directed.(B) Nos. 1515.00
35mm*35mm*5mm thick M.S angle suitable for above 2 TR to 4 TR
Capacity of ac machine
Installation charges for split type air-conditioning machine by making
modification to the window, if necessary by providing wooden frame made
of solid wood of good quality polished for proper support of the unit
8.0 9.00 blocking the side opening if any, around the unit, but within the window Job 4500.00
frame by asbestos cement sheet or hard wood from inside and outside
placing the unit inside the frame and starting the unit complete with
necessary painting.
Supplying and Installation charges for electrical point wiring with 15A plug
9.0 9.00 and switch with require wire size on existing wall opening with minor civil Job 3150.00
work covering of opening.
SBD SECTION -07 BILL OF QUANTITIES-144
Providing & erecting approved make OVAL CONDUIT with necessary
10.0 150.00 fittings fixed with adhesive solution and suitable clamps erected on Mtr. 35.00
wall / ceiling of following size.(2) 25mm
ADD CONTENGENCY 3%:-
I / We am/are willing to carry out the work at _____________ % above / below (percent should be written in figure
and in words) of the estimated rates mentioned above. Amount of my/our tender works out as under.
( In words ) _________________________ percentage above / below the estimated rate.
Estimated Amount put to tender Rs.
Deduct _______ % below Rs. Rs.
Estimated Amount put to tender Rs.
Add _______ % above Rs. Rs.
Total Amount Rs.
Total Amount Rs.
Note :1 All work shall be carried out as per Public Works Department Hand Book and other specifications of
Division or as directed.
Note :2 Rates quoted include clearance of site (prior commencement of work and its close) in all respects and
hold good for work under.
Note :3 I/ We have read the conditions mentioned in this tender and agree to abide by the same.
Note :4 In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-
10/2017 Cement Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items
where there is a change as per actual mix design the cost of difference of cement consumption have been
deducted from the rate of original item at the rate of input rate mentioned in all the tender.
Signature of Contractor President Chief Officer
Dahod Nagarpalika Dahod Nagarpalika
SBD SECTION -07 BILL OF QUANTITIES-145
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
GENERAL INSTRUCTIONS TO BIDDERS.pdf
Notes.pdf
OTHER IMPORTANT-1.pdf
OTHER IMPORTANT-2.pdf
OTHER IMPORTANT-3.pdf
Required Attachment Form as Per Bid Evaluation Criteria.pdf
SBD SECTION-1 TO 4.pdf
SBD SECTION-5 TECHNICAL SPECIFICATION.pdf
SBD SECTION-6 FORM OF BID.pdf
SBD SECTION-7 BILL OF QUANTITIES.pdf
SBD SECTION-7.1-SCHEDULE-B1-AC ESTIMATE.pdf
SBD SECTION-8 SECURITIES AND OTHER FORMS.pdf
SBD SECTION-9 DRAWING.pdf
SBD SECTION-10 DOCUMENTS FURNISHED BY BIDDER.pdf
Download all tender documents and submit your bid