CHIEF ENGINEER NAVY VISAKHAPATNAM
CHIEF ENGINEER (NAVY) MILITARY ENGINEER SERVICES STATION ROAD VISAKHAPATNAM 530004
PROVISION OF DEFICIENT SINGLE LIVING ACCOMMODATION (APPROX 300 MEN) FOR SAILORS AT VISAKHAPATNAM
2023_MES_575002_1
85416
Open Tender
Civil Works
760 days
VISAKHAPATNAM
AS PER NIT
8 documents required · 8 mandatory
₹3,000
Garrison Engineer Project Navy No 2 Visakhapatnam
₹12.6 L
Yes
22 Mar 2023
14 Jan 2023
11 Mar 2023
14 Jan 2023
9 Mar 2023
25 Feb 2023
14 Jan 2023 - 11 Feb 2023
Amount
SCHEDULE 'A' PART-I to SCHEDULE 'A' PART-XIV: Note: Schedule 'A' Part-I to Part-XIV are prepriced by MES. Bidders shall insert their lump sum amount in green coloured field under Column 6 only.
Lump Sum price worked out by the contractor for 'Buildings & Structures' as listed in Schedule 'A' Part-I.
Lump Sum price worked out by the contractor for 'Site Clearance/Area Development/Earth Work/Excavation as listed in Schedule 'A' Part-II.
Lump Sum price worked out by the contractor for 'Pile Foundation' as listed in Schedule 'A' Part-III.
Lump Sum price worked out by the contractor for 'Internal Water Supply' as listed in Schedule 'A' Part-IV.
Lump Sum price worked out by the contractor for 'Internal Electrification' as listed in Schedule 'A' Part-V.
Lump Sum price worked out by the contractor for 'External Water Supply' as listed in Schedule 'A' Part-VI.
Lump Sum price worked out by the contractor for 'External Electrification' as listed in Schedule 'A' Part-VII.
Lump Sum price worked out by the contractor for 'Area Drainage' as listed in Schedule 'A' Part-VIII.
Lump Sum price worked out by the contractor for 'Sewage Disposal' as listed in Schedule 'A' Part-IX.
Lump Sum price worked out by the contractor for 'Lightening Protection' as listed in Schedule 'A' Part-X.
Lump Sum price worked out by the contractor for 'Road/Path/Culvert', as listed in Schedule 'A' Part-XI.
Lump Sum price worked out by the contractor for 'Fire Fighting System' as listed in Schedule 'A' Part-XII.
Lump Sum price worked out by the contractor for 'Fire Alarm' as listed in Schedule 'A' Part-XIII.
Lump Sum price worked out by the contractor for 'Hot Water Supply' as listed in Schedule 'A' Part-XIV.
SCHEDULE 'A' PART-XV (MISCELLANEOUS ITEMS): (PILE FOUNDATION, SOLAR POWER INVERTER, ROAD/HARD STANDING/CULVERT, AREA DRAINAGE, SEWAGE DISPOSAL, INTERNAL ELECTRIFICATION, INTERNAL WATER SUPPLY,AVIATION LIGHT, LIGHTING PROTECTION, , FIRE FIGHTING SYSTEM, FIRE ALARM, HOT WATER,COOLING APPLIANCES, EXTERNAL WATER SUPPLY, EXTERNAL ELECTRIFICATION, DG SET, LIFTS, :
PILE FOUNDATION
Boring for bored cast in situ piles 500 mm dia in any type of soil/clay/soft rock except hard rock/fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and as directed.
Boring for bored cast in situ piles 500mm dia in hard rock / fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and as directed.
Carrying out routine load compression test on 500mm dia pile as per IS 2911 part-IV complete all as specified and as directed
Carrying out routine load Lateral test on 500mm dia pile as per IS 2911 part-IV complete all as specified and as directed
Carrying out initial Compression load test on cat in situ piles 500mm dia pile complete all as specified and as directed
Carrying out initial Lateral load test on cat in situ piles 500mm dia pile complete all as specified and as directed
Carrying out low strain integrity test on bored cast in situ piles 500mm including analysing the result as per ASTM D 5882 complete all as specified and as directed.
SOLAR POWER INVERTER
Supply, fixing, testing and commissioning of Solar Panel powered Inverter (Sine wave) with Battery backup for 8 Hours of capacity 03 KW (single phase 230 Volt, 50Hz, AC supply) complete (off grid Type) with and inclusive of electrical and mechanical accessories & stand for Inverter and Batteries. Note: (i) Solar panel of specification 320 Wp(minimum) polycrystalline type to be provided. (ii) Invertor and battery backup shall be placed near stair case. (iii) Tubular battery of 12 Volt, 150 AH of sufficient quantity to be provided to achieve 8 hours backup and rate quoted shall deemed to be included the cost of battery. (iv) Solar inverter supply will feed the supply to light fittings of ground floor parking area, building security lights, passage lights of each floor, stair case lights of each floor and security lights provided on roof top of the building. (v) Point wiring for parking area lights, security lights fitted in bldg, light fittings in passage of each floor and stair cases shall be measured under relevant items of internal electrification schedule. (vi) Before carrying out the work, contractor shall submit wiring diagram for approval by Engr-in-Charge.
Supply and Fixing of Change over switch, single phase 240 Volt, 32 Amps two pole, side handle operated type with and inclusive of making necessary connections for incoming and out going from change over switch complete all as specified and as directed.
Supply and fixing concealed in wall MCB DB. double door type, Single pole and neutral 16 way sheet steel factory fabricated, powder painted with 200 amps rated bus bar 240 Volts natural link, IP : 43 protection, complete all as specified and as directed.
Supply and fixing concealed in wall MCB DB. double door type, Single pole and neutral 4 way sheet steel ,factory fabricated, powder painted with 200 amps rated bus bar 240 Volts natural link, IP : 43 protection, complete all as specified and as directed.
Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 2 x 4sqmm for phase and neutral duly colour coded and 1 x 4 sqmm for earth continuity conductor green in colour complete all as specified and as directed.
Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 2 x 2.5 sqmm for phase and neutral duly colour coded and 1 x 2.5 sqmm for earth continuity conductor green in colour complete all as specified and as directed.
Supply and Fix MCB SP, 6 to 32 Amps 240 Volts , 10KA, 'C' curve complete all as specified and as directed.
Supply and Fix MCB SPN, 6 to 32 Amps 240 Volts , 10KA, 'C' curve complete all as specified and as directed.
ROAD/HARD STANDING/CULVERT
Material and Labour for Granular sub base (GSB) with grading V of 200mm thick compacted thickness (laid in two layers of 100mm each, compacted separately) confirming to grading as specified, spread, rolled and consolidated to required gradient and camber complete using necessary mechanical paver/grader and vibratory soil compactor of capacity 8-10 tonne all as specified and as directed. (a) Pavement shall be made for solid quantity arrived after consolidation. (b) Compaction of granular sub base filling shall be carried out under optimum moisture condition to achieve 98.50 modified density. (c) Curing shall be carried out as per IRC recommendations. (d) Before execution of this item the approved material obtained from outside MD land shall be tested/checked for suitability to use. (e) The lead/Royalty involved is to be ascertained by the contractor before quoting his tender and no extra payment/Adjustment for increased in lead or rate of royalty due to whatever reason shall be admissible on his account. (f) Contractor shall use vibratory earth compactor in lieu of power roller to achieve 98.00% MDD at OMC without any extra cost and the method of compaction to be adopted as per recommendation of agency reporting MDD at OMC. (g) GSB shall be as per MORTH specification as detailed in particular specification.
AREA DRAINAGE
M&L for PCC solid block masonry with C(5.0) grade solid units having density not less than 18000 kg/sqm as per IS 2185 Part-I, exceeding 10 cm in width and setting in cement mortar CM (1:4), complete all as specified and as directed.
M&L for Precast RCC slabs factory made (SFRC) as in manhole covers in 1:2:4 Type B1 using 20mm graded stone aggregate, set in cement mortar (1:4) use of form work complete all as specified and as directed.
Removal of excavated surplus soil outside MD land complete all as specified and as directed.
SEWAGE DISPOSAL
M&L for Precast RCC slabs factory made (SFRC) as in manhole covers in 1:2:4 Type b1 using 20mm graded stone aggregate, set in cement mortar (1:4) including use and waste of form work complete all as specified and as directed.
M&L for PCC solid block masonry with C(5.0) grade solid units having density not less than 18000 kg/sqm as per IS 2185 Part-I, exceeding 10 cm in width and setting in cement mortar CM (1:4), complete all as specified and directed.
Removal of excavated surplus soil outside MD land complete all as specified and as directed.
INTERNAL ELECTRIFICATION
Material and Labour for Point wiring with 1.5 sqmm PVC insulated and unsheathed copper conductor cable Multistranded 1100 volts grade, FRLS, ISI marked drawn through and including non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed to wall including provision of pre fabricated pressed steel terminal box of suitable size made out of 1.2 mm thick sheets, for mounting modular brackets, with and including modular brackets and switch plates as required at site for fixing modular type switches, sockets etc. including one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly one light point controlled by one switch complete all as specified and directed.
Material and labour for Point wiring with 1.5 sqmm PVC insulated and unsheathed copper conductor cable Multistranded 1100 volts grade, FRLS, ISI marked drawn through and including non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed to wall including provision of pre fabricated pressed steel terminal box of suitable size made out of 1.2 mm thick sheets, for mounting modular brackets, with and including modular brackets and switch plates as required at site for fixing modular type switches, sockets etc. including one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly one ceiling fan/Exhaust fan point controlled by one switch complete all as specified and directed.
Material and Labour for Point wiring with 2.5 sqmm PVC insulated and unsheathed copper conductor cable Multistranded 1100 volts grade, FRLS, ISI marked drawn through and including non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed to wall including provision of pre fabricated pressed steel terminal box of suitable size made out of 1.2 mm thick sheets, for mounting modular brackets, with and including modular brackets and switch plates as required at site for fixing modular type switches, sockets etc. including one run of 2.5 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly one 3 pin socket outlet 06 Amps socket on independent board complete all as specified and directed.
Material and albour for Point wiring with 4 sqmm PVC insulated and unsheathed copper conductor cable Multistranded 1100 volts grade, FRLS, ISI marked drawn through and including non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed to wall including provision of pre fabricated pressed steel terminal box of suitable size made out of 1.2 mm thick sheets, for mounting modular brackets, with and including modular brackets and switch plates as required at site for fixing modular type switches, sockets etc. including one run of 4 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly one 3 pin socket outlet 15 Amps socket on independent board complete all as specified and directed.
Material and Labour for Point wiring with 1.5 sqmm PVC insulated and unsheathed copper conductor cable Multistranded 1100 volts grade, FRLS, ISI marked drawn through and including non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed to wall including provision of pre fabricated pressed steel terminal box of suitable size made out of 1.2 mm thick sheets, for mounting modular brackets, with and including modular brackets and switch plates as required at site for fixing modular type switches, sockets etc. including one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly one light point controlled by two Nos two way switch complete all as specified and directed.
Supply and fixing ceiling fan complete with blades, down rods, electronic regulator modular type, and accessories, 230 V, 1200 mm sweep, minimum air delivery 210 CFM with service value 6.0 BEE five star rated with brushless direct current motor (BLDC) with and including flexible copper wire 1 sqmm form ceiling rose to connector of ceiling fan complete all as specified and as directed.
Supply and fixing Exhaust fan made out of sturdy engineering plastic complete with louvers shutter, 230 Volt, 50 Hz, RPM 1200 copper winding of sweep 250 mm . fixed on wall making opening, fixing and making good the disturbed surfaces etc. complete with and inclusive of making necessary electric connection from ceiling rose to fan through 1 sqmm twin core flexible wire complete all as specified and as directed.
Supply and fixing exhaust fan, steel body AC single phase 230 Volt of size 300 mm sweep with blades, and frame and louvers fixed on wall making opening, fixing and making good the disturbed surfaces etc. complete with and inclusive of making necessary electric connection from ceiling rose to fan through 1 sqmm twin core flexible wire complete all as specified and as directed.
Supply and fixing exhaust fan, steel body AC single phase 230 Volt of size 380 mm sweep with blades, and frame and louvers fixed on wall making opening, fixing and making good the disturbed surfaces etc. complete with and inclusive of making necessary electric connection from ceiling rose to fan through 1 sqmm twin core flexible wire complete all as specified and as directed.
Supply and fixing Energy efficient LED tube light fitting with tube 5 watts or nearest size ,240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and as directed.
Supply and fixing Energy efficient LED tube light fitting with tube 10 watts, 240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 sqmm 3 core flexible copper conductor cable complete all as specified and as directed
Supply and fixing Energy efficient LED tube light fitting with tube 20 watts or nearest size ,240V, 50hz surface mounted, decorative ultra slim round profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc. including connecting up with 1.0 sqmm 3 core flexible copper conductor cable complete all as specified and as directed
Supply and fixing LED Security light fitting with tube 30W New generation Energy saving &environmental friendly long life made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre wired with 1.0 Sqmm copper conductor cable upto connector including 1.5 m long GI Tubing light grade of 32mm dia bend to shape for fixing on wall/pole with suitable MS brackets nuts and bolts etc. complete all as specified and as directed.
Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 4 x 16 sqmm for phase and neutral duly colour coded and 1 x 16 sqmm for earth continuity conductor green in colour complete all as specified and as directed.
Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 4 x 10 sqmm for phase and neutral duly colour coded and 1 x 10 sqmm for earth continuity conductor green in colour complete all as specified and as directed.
Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 4 x 6 sqmm for phase and neutral duly colour coded and 1 x 6 sqmm for earth continuity conductor green in colour complete all as specified and as directed.
Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 2 x 6 sqmm for phase and neutral duly colour coded and 1 x 6 sqmm for earth continuity conductor green in colour complete all as specified and as directed.
Material and labour for submain wiring complete with earth wire of PVC insulated Multistranded copper conductor FRLS cable, ISI marked with and inclusive of suitable size PVC rigid conduit concealed to wall, and PVC wire of size 2 x 4 sqmm for phase and neutral duly colour coded and 1 x 4 sqmm for earth continuity conductor green in colour complete all as specified and as directed.
Supply and fixing concealed in wall Vertical MCB DB double door type, TPN 6 way 415V, 50Hz , IP 43 protection with 200A rated bus bar , including provision for fixing MCCB FP 125 amp as incomer and outgoing circuits MCB SP/TP complete, fill empty way with blanking plates complete all as specified and as directed. Note: MCCB and MCBs shall be measured and paid separately.
Supply and fixing concealed in wall Vertical MCB DB double door type, TPN 4 way 415V, 50Hz , IP 43 protection with 200A rated bus bar , including provision for fixing MCCB FP 125 amp as incomer and outgoing circuits MCB SP/TP complete, fill empty way with blanking plates complete all as specified and directed. Note: MCCB and MCBs shall be measured and paid separately.
M&L for earthing complete with galvanised steel plate electrode 600 x 600 x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI strip of 25mm x 4mm by means of bolts, nuts, check nuts and washers of GI all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe light grade for watering pipe and 32 mm bore GI light grade for earth lead protection pipe connected upto DBs, and suitable CI top cover with handle, funnel, strainer, charcoal, salt and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC work complete all as specified and as directed.
Supply and fixing TV socket with and inclusive of prefabricated terminal box and switch plate for fixing TV socket complete all as specified and as directed.
Supply and fixing PVC junction box with top cover of approx. size 10cm x 7.5 cm rectangular type concealed to wall to for end termination/jointing for optical fibre cable complete all as specified and as directed.
Supply and drawing Internal jelly filled multi mode optical fibre cable suitable for internet services, tele communications, data transfer and cable TV net work complete all as specified and as directed.
Supply and fixing Sheet metal enclosures with socket plug top and MCB of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps 240 volts complete all as specified and as directed.
Supply and fixing double stiff pendants, comprising of galvanised steel or chromium plated brass bell mouth connectors 2 Nos with back plated and 2 x 1 m long parallel 20mm dia galvanised or stove enamelled screwed steel conduit with two check nuts for fixing tube light fittings metre long twin core 1 sqmm conductor flexible wire complete all as specified and as directed.
Supply and fixing Energy efficient LED wall mounted table lamp fitting 03 watts or nearest size ,240V, 50Hz of 360 degree adjustable type, white body including making necessary electric connection complete all as specified and as directed.
INTERNAL WATER SUPPLY
S&F Bib taps long body ,cast copper alloy, with capstan head, fancy type, chromium plated screwed down for size of 15 mm dia complete all as specified and as directed.
S&F Bib taps two way, fancy type screwed down for size of 15 mm inner dia, suitable for 16 mm outer dia CPVC pipes complete all as specified and as directed.
S&F health faucet chromium plated , fancy type with steel flexible complete of size of 15 mm dia suitable for 16 mm dia outer dia CPVC pipes complete all as specified and as directed.
S&F Stop valves(15mm bore) concealed cast copper alloy, chromium plated fancy type, screwed down high pressure with crutch or butterfly handle screwed both ends suitable for CPVC pipes complete all as specified and as directed.
S & F Angle stop valve, chromium plated , fancy type , high pressure screwed and fixed 15 mm inner dia suitable for 16 mm dia outer dia CPVC pipes with and including chromium plated urinal water dropper complete all as specified and as directed.
S&F Bib taps long body ,cast copper alloy, with capstan head, fancy type, chromium plated screwed down for size of 20 mm dia, suitable for CPVC pipes complete all as specified and as directed.
S&F Bib taps long body ,cast copper alloy, with capstan head, fancy type, chromium plated screwed down for size of 15 mm dia complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
S&F Bib taps two way, fancy type screwed down for size of 15 mm inner dia, suitable for CPVC pipes complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
S & F Angle stop valve, chromium plated , fancy type , high pressure screwed and fixed 15 mm inner dia suitable for 16 mm outer dia CPVC pipe complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
S&F PVC connections 15mm size with PTMT nuts of length 450 mm complete all as specified and as directed.
S&F health faucet chromium plated , fancy type with steel flexible complete of size of 15 mm dia suitable for CPVC pipes complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
S&F Stop valves(15mm bore) concealed cast copper alloy, chromium plated fancy type, screwed down high pressure with crutch or butterfly handle screwed both ends suitable for CPVC pipes complete all as specified and as directed. Note: The maximum flow rate will be 03LPM
S&F swivel shower of PTMT any colour for fixing with 15mm inner dia of CPVC pipe complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
S&F shower arm 15mm size 195mm long with bend of 45 degree with flange of PTMT any colour complete all as specified and as directed.
S & F Angle stop valve, chromium plated , fancy type , high pressure screwed and fixed 15 mm inner dia suitable for 16 mm dia outer dia CPVC pipes with and including chromium plated urinal water dropper complete all as specified and as directed.
AVIATION LIGHT
Supply and fix aviation obstruction light LED type 10 Watt including standard fixing arrangements complete all as specified and as directed.
Supply and fix cable PVC insulated PVC sheathed LT 1100 V grade with copper conductor of size 3 core 2.5 sqmm multi stranded conductor laid in ground fixed to wall roof etc. with suitable clamps spacers bolts nuts etc. complete all as specified and as directed
Supply and fix time switches 250 V single Phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and as directed.
LIGHTENING PROTECTION
Material and Labour for Earthing complete with galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32x 6 mm (up to 7.5m in length from earth plate) by means of brass bolts and nuts check nuts and washers of brass all as specified and shown in electrical plate no 3 of SSR part 1 including Charcoal and salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with CI Cover 10mm thick Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel, 50 mm dia light grade pipe for protection of earth electrode and 20mm dia pipe medium grade for watering and tested on completion complete all as specified and as directed.
FIRE FIGHTING SYSTEM
Supply, installation, testing and commissioning of booster pumps for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 36 m head, 900 LPM discharge with minimum pressure of 3.5 kg/sqcm along with starter complete all as specified and directed.
Material and Labour for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead strip of 32 x 6 mm cross-sectional area by means of bolts, nuts, check nuts and washers of galvanised iron earthing lead all as shown electrical plate, watering funnel, 15 mm dia light grade pipe for protection of earth electrode and 20mm dia medium grade pipe for watering and testing on completion complete all as specified and as directed.
Supply and fix water pressure gauge 100 mm dia at the delivery side of pump set complete tubing fitted with the stop cock etc. of pressure 25 kg/sqcm, all as per standard practice complete all as specified and as directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following size 4 core 16 sqmm for booster pump complete all as specified and as directed.
Supply and fix single sided LED signage with built in battery back-up for 2 hrs of single "EXIT" of colour green suitable for operating voltage of 230 Volts, 50Hz complete all as specified and as directed.
Supply and install galvanised mild steel fire buckets with fire stand containing dry sand conforming to IS: 2546 complete all as specified and as directed.
FIRE ALARM SYSTEM
Supply and fix 2 core 1.5 sqmm FRLS armoured copper cable as per IS:1554 to wall/ roof/ false ceiling/ floors with necessary clamps/ saddles complete all as specified and as directed.
Supply, install and commissioning integrated public address and talk back facility for G+9 buildings consisting of following:- (A) Loudspeaker System of highly adaptable surface-mount design, a 2-way bass-reflex type, 4''(10 cm) cone driver for low frequency and 1''(2.5 cm) balance dome tweeter for high frequency, with internal transformer that allow both high-impedance and low-impedance drive of rating 15W/100. The nominal coverage angle shall be 110⁰ horizontal and 110⁰ vertical. The measured sensitivity shall be 88 dB SPL and maximum SPL shall be 106 dB SPL. The Bracket shall allow the loudspeaker to be mounted on both walls and ceilings. The loudspeaker shall comply with dust and water resistance rating of IPX3. The grille shall be constructed of 0.6 mm- thick powder coated perforated steel, with an aperture ratio of 51% inclusive of all accessories and should be installed minimum 03 Nos on each floor.
Two RJ45 connectors with the YDIF format shall be provided for digital input/output that allow the amplifier to be connected via an Ethernet cable to another YDIF-equipped device. Two 3-pin Euro block connectors shall be provided for a REMOTE connector and a FAULT OUTPUT connector. The Rotary switch shall be provided for specify the UNIT ID that identifies each unit individually when multiple devices such as amplifiers and processors are connected. The built-in protection circuitry shall monitor heat, voltage and current levels to minimize potential damage from overloads. The speaker output shall be muted if the heat sink of the amplifier section exceeds 90°C or the impedance falls below rated, which restored automatically. The analogue circuits shall be shut down if the power supply section exceeds 100°C. The amplifier shall be cooled by two temperature-controlled, 3-step speed fans for minimum acoustic noise, with air flow from front-to-back. The amplifier shall conform to the latest EU RoHS hazardous substances and WEEE directives. The amplifier shall be 480mm wide, 88mm high, and 422mm deep.
(C) Mixing Console shall be versatile 6-channel mixer and have 6 line output (2 mono, 2 stereo) and 2 microphone inputs, two stereo output and one headphone output shall be provided. One stereo bus shall be provided and have discrete class - A "D-PRE" types of high sound quality. It shall be robust and built into an impact-resistant powder coated metal chassis. Dimension shall be 149 (W) x 202(D) 62(H) mm. Note: The rate quoted shall inclusive of all material like suitable size copper wire etc. for interconnection of the system.
HOT WATER SUPPLY
Supply, install, test, and commissioning of Solar water heating system complete unit Flat plate collector type based on indirect transfer of heat, with heat exchanger of 300 litre per day capacity, with electrical heating back up including features are advanced solar glass gives better performance in cloudy weather, jacketed type heat exchanger model offering strongest protection against corrosion, full plate absorber provides greater area for absorption of sunlight resulting in faster heating of water collectors and light weight with better aesthetic looking complete all as specified and as directed.
Supply and fix 50 mm bore hot water pipe duly insulated with glass wool and aluminium cladding complete all as specified and as directed.
Supply and fix 32 mm bore hot water pipe duly insulated with glass wool and aluminium cladding complete all as specified and as directed.
Supply and fix 25 mm bore hot water pipe duly insulated with glass wool and aluminium cladding complete all as specified and as directed.
COOLING APPLIANCES
Supply, installation, and commissioning of Water cooler fully stainless steel, electric driven single phase having nominal cooling capacity 40 litres/hour and storage capacity 80 ltr complete all as specified and as directed.
Supply and fix water cooler electric driven (single phase), fully stainless steel having approx storage capacity of 120 litre and nominal cooling capacity of 60 Litres per hour complete all as specified and as directed.
Supply and fix and testing refrigerator, electric driven (single phase), capacity 400 Litres BEE 4 star rated, double door, frost free, complete all as specified and as directed.
Supply and fix and testing refrigerator, electric driven (single phase), capacity 200 Litres BEE 4 star rated, double door, frost free, complete all as specified and as directed.
Supply and installation, and commissioning of hard top deep freezer single phase 240 volt, 50 Hz of 405 litre capacity having single door, complet all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volt to 250 Volt with output voltage stabilized at 230 Volt with accuracy of ± 2.5% and of capacity 2.0 kVA complete all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.0 kVA complete all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 0.5 kVA complete all as specified and as directed.
EXTERNAL WATER SUPPLY
Material and labour for 100 mm bore Ductile Iron Pressure Pipes, Centrifugally Cast [Spun], Class "K-9" with Spigot Socket ends confirming to IS -8329 in standard lengths suitable for Push-On-Rubber Gasket Jointing with inside Cement Mortar Lining and Black Bitumen external coating and including necessary DI Specials as required, complete all as specifies and as directed. Note:- Earth work and excavation will be measured and paid separately.
Supply and install electric driven monoblock pump set of 10 HP, head 40 mtr, 468 LPM suitable for 415 Volt 3 phase, conforming to IS-12469:1988 with CI casing bronze impeller and stainless steel shaft mounted on heavy duty bearing of suitable capacity with suitable foundation and electric connection complete all as specified and as directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.
Material and Labour for Construction of Valve Chamber of size 900 x 900 x 900 mm (internal dimenson) suitable for 100mm bore sluice valve including excavation and earth work in any type of soil and 100mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate foundation, brick work in Cm(1:6) plastering internal surface 15mm thick in CM(1:4) PCC 1:3:6 Type C1 coping 50 x 50 x 6 mm angle iron 6mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of sinc chrome primer all as shown on drawing complete all as specified and as directed.
Supply and Fixing CI of Sluice valve of 100 mm dia, confirming to IS -14846, Class PN -1.0, Stainless Steel Spindle, Gun Metal Rings including Wheel for operation, Flanged and Drilled, Non Rising Type , Long Body type including all Joints with Rubber Gasket and Jointing Materials, Bolts, Nuts, Washer including taking down existing Sluice valve of any description complete all as specified and as directed.
Supply and Fixing CI Sluice valve of 80 mm dia, confirming to IS -14846, Class PN -1.0, Stainless Steel Spindle, Gun Metal Rings including Wheel for operation, Flanged and Drilled, Non Rising Type , Long Body type including all Joints with Rubber Gasket and Jointing Materials, Bolts, Nuts, Washer including taking down existing Sluice valve of any description complete all as specified and as directed.
Supply and fix Foot Valve conforming to IS 4038, but 100 mm dia complete all as specified and as directed.
Supply and install non return butterfly valve of size 80mm dia complete all as specified and as directed.
Excavation in trenches & Cutting existing steel tubing of 150 x 150 x 100 mm dia for alterations or additions necessarily done in position without taking down, dewatering for inserting flanged sockets, 'Tee' with reducer to 100 mm, etc for tapping including returning filling complete all as specified and as directed.
Supply and install LT Panel board made out of CRCA sheet 2 mm thick Indoor Pedestal type, CPRI approved, totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, danger notice plate, snickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material including as per IS: 8623 Aluminium bus bar with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 200 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: (Pump house panel) INCOMING: (a) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 kA - 01 No OUTGOING: (a) MCCB 4 Pole, 415 V, Adjustable type, 32 Amps with breaking capacity 16 kA - 04 Nos ( 01 for fire pump, 02 fresh water pump, 01 spare) (b) MCB TPN 32 A, 'C' curve - 04 Nos ( 01 utility services, 01 spare) (c) Automatic Star delta starter of capacity 10 HP for fresh water pump- 02 Nos (d) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases (e) Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, power, energy, THD along with connected CTs - 05 set.
Supply and Fix digital type water meter (Electro-magnetic type) flanged type, MS body, for smart metering, of high accuracy, robust design, IP-67 enclosure, max flow 1500 LPM for residential water supply scheme for fixing of 100 mm dia GI/DI pipe line, fixing, necessary excavation/ return filling in, and connecting FRLS PVC insulated 3 Core, PVC sheathed unarmoured copper wire drawn through GI pipe light grade 20 mm as required at site and making connection complete all as specified and as directed. Note: (i) FRLS cable and GI pipe light grade 20 mm shall be measured separately.
Supply and Fix, digital type water meter (Electromagnetic type) flanged type, MS body, for smart metering, of high accuracy, robust design, IP-67 enclosure, max flow 1500 LPM for residential water supply scheme for fixing of 80 mm dia GI/DI pipe line, fixing, necessary excavation/ return filling in, and connecting FRLS PVC insulated 3 Core, PVC sheathed unarmoured copper wire drawn through GI pipe light grade 20 mm as required at site and making connection complete all as specified and as directed. Note: (i) FRLS cable and GI pipe light grade 20 mm shall be measured separately.
Supply and fix PVC insulated FRLS cable copper conductor 3 core 2.5 sqmm PVC sheathed unarmoured drawn through GI pipe light grade complete all as specified and as directed. Note: (i) GI pipe shall be measured and paid for separately (ii) Rate quoted shall be deemed to inclusive necessary excavation and return filling in cable laying.
EXTERNAL ELECTRIC SUPPLY
Supply and Installation , testing and commissioning distribution Transformer step down, outdoor type, 11//0.433 KV with HT 3 phase and LT 3 phase 4 wire system copper wound with off load tap changing arrangement on HT side for a variation of secondary voltage +/- 7.5% insteps of 2.5% continuous rating of 160 KVA outdoor type confirming to (IS 1180, level-II) with and including the following: (a) Lifting lugs/ hooks for transformer and tank. (b) Earthing terminal rating and diagram plate. (c) Air release device. (d) Oil filling inlet pipe with plug. (e) Drain outlet pipe with brass gate valve with dummy plug. (f) Conservator with level gauge. (g) Silica gel breather (h) First oil fill up upto the recommended level by manufacturer with new oil conforming to IS 335. (j) Type of connection : Delta/Star. (k) Type of cooling : ONAN. (l) Vector Group : DYN 11. (m) Type of connecting arrangement : Cable termination boxes on both HT and LT side. (n) Temperature rise over an ambient of 50 degree centigrade maximum. (o) All necessary arrangements with devices for measuring the temperature of core, winding and oil. (p) In addition to the above all standard fittings shall be provided as per IS norms.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 95 sqmm 3 core complete all as specified and as directed.
Supply and fix Cable jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm each complete all as specified and as directed.
Supply and fix Cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm each complete all as specified and as directed.
Supply and fix Cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm each complete all as specified and as directed.
Supply and fix XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 240 sqmm 3.5 core complete all as specified and as directed.
Supply and fix XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 120 sqmm 3.5 core complete all as specified and as directed.
Supply and fix XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 35 sqmm 3.5 core complete all as specified and as directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 16 sqmm 4 core complete all as specified and as directed.
Material and Labour for earthing complete with galvanised steel earth plate electrode 600 × 600 × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead strip of 32 x 6 mm cross-sectional area by means of bolts, nuts, check nuts and washers of galvanised iron earthing lead all as shown electrical plate, watering funnel, 15 mm dia light grade pipe for protection of earth electrode and 20mm dia medium grade pipe for watering and testing on completion complete all as specified and directed.
Material and Labour for LT Panel board (Distribution Panel) made out of CRCA sheet 3.15 mm thick outdoor Pedestal type, CPRI approved totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, snickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switcher gear, and the nuts/ bolts etc used are to be made of rust proof material including aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V, 500 A capacity complete with powder coating, necessary internal electric connection as required, with and inclusive of the following items: INCOMING: a) MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 50 kA - 01 No OUTGOING: a) MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 kA -02 Nos ( 01 for Building, 01 spare) b) MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 25 kA -02 Nos (01 for DG standby panel, 01 spare) c) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases d) Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, power, energy, THD along with connected CTs
Material and Labour for LT Panel board (Distribution Panel) made out of CRCA sheet 2 mm thick indoor Pedestal type, CPRI approved totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, snickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switcher gear, and the nuts/ bolts etc used are to be made of rust proof material including aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V, 300 A capacity complete with powder coating, necessary internal electric connection as required, with and inclusive of the following items: INCOMING: (a) MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 kA - 01 No OUTGOING: (a) MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 25 kA -02 Nos (01 for first floor, 01 spare) (b) MCCB 4 Pole, 415 V, Adjustable type, 40 Amps with breaking capacity 25 kA - 09 Nos (08 for each floor, 01 spare) (c) MCB SPN 32 Amps, 'C' curve -02 Nos (for change over switch at ground floor, inverter) (d) MCB TPN 20 Amps, 'C' curve - 01 Nos (e) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases (f) Multifunctional Intelligent Panel Meter digital type for measuring Volts,Current, Hz,pf, power, energy,THD along with connected CTs
Material and Labour for LT Panel board made out of CRCA sheet 3.15 mm thick outdoor Pedestal type, CPRI approved, totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material including as per IS: 8623 Aluminium bus bar with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 200 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: (DG Standby Panel) INCOMING: a) MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 25 kA - 01 No OUTGOING: a) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 kA - 02 Nos (01 for Pump house Panel, 01 spare) b) MCCB 4 Pole, 415 V, Adjustable type, 32 Amps with breaking capacity 16 kA - 02 Nos (01 Lift, 01 spare) c)MCB TPN 20 A , 'C' curve - 02 Nos ( 01 for street light, 01 Spare ) d) Time switch with contactor - 01 Nos e) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases f) Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, power, energy, THD along with connected CTs
Supply and installation of Steel tubular swaged pole complete with cast iron base plate, final and single swan neck, bolts, nuts and screws all as specified type 410 SP-31 (9m long) as per IS-2713 (Part-I to III) of 1980 and applying three coats of black bituminous paint through out internally and two coats externally on the portion embedded in concrete and applying two coats of aluminium paint over a coat of zinc chrome primer to the exposed surfaces all as directed including foundation complete all as specified and directed.
Material & Labour for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.
Supply and fixing LED street light fitting 35/36 W 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with impact and corrosion resistant including thermal management in multiple optices complete with IP 65/66 protection complete all as specified and as directed.
Supply and fix Loop in loop out box (minimum size 200mm x 160mm x 98mm) of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 kA, C Curve Overload and Short Circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands, etc complete all as specified and as directed.
Material and Labour for PVC insulated copper conductor of size 2.5 sqmm 3 core drawn through PVC pipe with clamping materials complete all as specified and as directed.
Material and Labour for earthing complete with galvanised steel earth plate electrode 600 × 600 × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point indicated including testing on completion complete all as specified and as directed.
Supply and fix danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. Clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size complete all as specified and as directed.
Supply and fix chain link fencing of mesh 50 x 50 mm made out of 10 gauge dia mild steel wire over PVC coating to make overall dia as 6 gauge including GI binding wire and fixing MS round bar 10 mm dia as line wire holding chain link mesh complete all as specified and as directed.
Supply and fix HT cable route indicator complete all as specified and as directed.
DG SET
(iv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% (v) Frequency regulation +/- 1% (B) Diesel Engine: - Adequate capacity of Diesel engine as accosted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under (i) Fly wheel with housing (ii) Cooling system :- Moulded radiator with fan & belts (iii) Cooling Water pump : - Centrifugal type belt driven (iv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer : Residual type Bellows iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses.
(vi) Lub oil System : Lubricating oil filter Lubricating oil pump (vii) Air Intake System : Air intake Manifold Air cleaner dry type (viii) Governor :- Electronic Governor (ix) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator. (x) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel (xi) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or asper standard practice ignition key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display. (xii) Safety Controls : - Engine low lube oil pressure high water temperature and over speeding of engine.
(xiii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling. (xiv) Accessories :- AVM Pads built in enclosure and for entire unit on platform. (xv) Base Frame : - Should be provided as OEM norms (xvi) MS pipe line to and from the fuel tank to the DG Set (C) AMF Panel :- Factory made inbuilt type control cubical type made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 volts 3 -phase 4 - wire AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 45 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 volts grade of suitable capacity, fuses, name plates consisting of 4 pole MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etc. (a) Annunciation with indication lamps for : (i) Low lub oil pressure. (ii) High Water Temperature. (iii) Engine over speed. (iv) Battery low voltage Controls :- (a) Load on Indication (b) Load off indication (c) Engine start push button (d) Engine stop push button
(iii) The generating set batteries and control panel should be inside the enclosure. (iv) Construction Details/specification are as follows: (a) Outer body :- CRCA Sheet of 1.6mm thick (b) Doors :- CRCA sheet of 1.6 mm thick c) Sound Insulation :- As per OEM Norms (v) The acoustic should be composite in construction and fully assembled integral unit. (vi) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated plat form. (vii) The DG Set should be provided with external Emergency stop push button (viii) The enclosure should be suitably illuminated by CFL/FTL Lamp fittings. (ix) The noise level should be 75 dba at 1m under free field conditions. (x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade. (E) The coated rate includes excavation, removing of soft soil and PCC, Cement Concrete foundation, filling and mass concrete type B2 (1:2:4) using 40 mm graded aggregate of size not less than 4.6 x 3.0 x 0.8 m for placing of DG Set complete all as specified.
Material and Labour for earthing complete with galvanised steel earth plate electrode 600 × 600 × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead strip of 32 x 6 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel using galvanised iron strip 32 x 6mm and 50 mm dia light grade GI pipe upto test point or 7.5 mtr and GI pipe 20 mm medium grade for watering pipe as earthing lead all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion. all as specified and as directed.
(a) Fire man switch (b) Automatic rescue divide (ARD) during power failure including manual operation provision with suitable capacity of battery designed for funning the lift with full load. (c) Battery operated emergency light (LED ceiling fitting), alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeable arrangement for battery. (d) Four sleek circular LED light fitting in false ceiling . (e) One Sleek circular PVC heavy duty fan in false ceiling. Make for(c) & (d) : Philips / Bajaj / Havells / Crompton Greaves. (f) Aluminium chequered plate (3 mm thick) as flooring joint in chequered plate should not more than one and top covering with Granite flooring complete. (g) Non stop button / independent operation with braille script. (h) Over load warning indicator both audio and visual type with tripping system having relays etc (overload protecting / tripping system). (j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. (k) Car size shall be conformity with IS-3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail 38 mm hairline finish.
(l) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. (m) Mirror of 4 mm thickness of suitable size as specified. (n) Specification plate with complete details. (o) Continuous earthing for machine and equipments, 2 Nos of GI plate earthing per lift as shown in electrode plate No 3 of SSR Part -I. (p) Steel wire rope of adequate size as per relevant IS and as per manufacturer specifications. (q) Other standard fixtures and fitting like guide rails, sheaves, counter weights with guards, buffers, gear unit breaks, control panel, locks, governor, car operational panel, power, control and trailing cables complete. (r) Full length display indicator panel. (s) Main drives and control shall be of latest, high effective and low power consumption. (t) Suitable phase reversal relay shall be provided on the controller to protect lift / equipment against phase reversal, phase failure and low voltage. (u) Stainless steel front opening type landing door & car door with small opening for vision of size 200 mm x 800 mm with toughened glass not likes than 8mm thick. Make of Toughened Glass : Safe / Saint Goblin Glass / Mudguard float glass / kesar / Asshi Indian / Atul Tuf / Hindustan pilkington glass works / Trivenin float glass. (v) Three way Intercom connectivity i.e. Ground Floor security post, car cabin and machine room.
SCHEDULE 'A' PART-XVI OUTSOURCING OF LIFTS DURING FIRST YEAR DEFECTS LIABILITY PERIOD
Outsourcing of services for operation of electrically operated lift (8 Passengers-02) to serve (G+9 floors) by providing services of one lift operator [Semi Skilled] in each sjift of 8 hours duration per each lift, on all the days in two shifts a day including sunday & holidays, including taking care of from any pilferage, theft or damage etc., during first year defects liability period complete all as specified and as directed.
SCHEDULE 'A' PART-XVII: OUTSOURCING OF LIFTS DURING SECOND YEAR DEFECTS LIABILITY PERIOD
Outsourcing of services for operation of electrically operated lift (8 Passengers-02) to serve (G+9 floors) by providing services of one lift operator [Semi Skilled] in each sjift of 8 hours duration per each lift, on all the days in two shifts a day including sunday & holidays, including taking care of from any pilferage, theft or damage etc., during second year defects liability period complete all as specified and as directed.
Notes for (OUTSOURCING SERVICES FOR LIFT) : (i) The lift shall be operated daily in two shifts as directed by the Engineer-in-Charge. (ii) The timings for two shifts of 8 hours each daily i.e. First shift be from 0630 hours to 1430 Hours and Second Shift shall be from 1430 Hours to 2230 Hours. (iii) In case of non function of passenger lift, the Goods Lift installed in the same building shall be operated as directed. (iv) The work shall be supervised by adequately qualified supervisor with relevant experience of minimum 5 years items under BoQ shall be deemed to be including the same. (v) The unit rate is deemed to include for maintaining log books, record of repair /replacement of perished/unserviceable, minor adjustments, minor repairs of all accessories, cleaning/up keeping of lift and surrounding area as directed by the Engineer-in-Charge. (vi) One emergency light and necessary tools shall be available in a tool box with the operator in the shift for smooth functioning of lifts. (vii) Conveyance and communication system like mobile phone etc. shall be provided by the Bidders/Service providers to all Lift Attendants/Supervisors. (viii) The Bidders shall ensure housekeeping, environmental cleanliness of area all round the lift and the area shall be kept absolutely neat and clean. The lift attendant shall clean the Lift car cabin, all landing floors and tiles all round lift doors with necessary cleaning material such as cotton cloth and cleaning solution etc.
(ix) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wages paid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. The Bidders shall also insure the workmen employed on the job. (x) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same. (xi) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. "Name of the firm and designation" on front and on the back of the T-shirt along with protective clothing/ gear. The bidders shall also provide shoes to the workers and the persons shall not be allowed to enter the work site without wearing shoes. (xii) INSURANCE: The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations.
(xiii) The rate quoted by the bidders shall be deemed to be including basic rate [Minimum wages by Government of India/ State Government/ local body, whichever is higher], employers contribution towards Employees Provident Fund [EPF] liability , contribution towards Employees state insurance corporation [EISC], contribution towards Bonus, Overhead and profit and Labour welfare Cess [LWC] as applicable depending upon the manpower requirement. This will create onus on the bidders to ascertain in the relevant rates and quote accordingly. The rates quoted shall be inclusive of all Taxes, Cess, levies as applicable including GST. (xiv) The prevailing Rate/wage/Contribution shall be as applicable on the bid submission end date. (xv) DRESS Code: The bidders shall providers shall provide the workmen with dark Blue colour uniform (Formal Pant & T-Shirt) wth labels showing printed i.e. " Name of the firm and Designation" on front and on the back of the T-shirt along with protective clothing/gear. The bidders/Service providers shall also provide shoes to the workers and the persons shall not be allowed to enter the work sie without wearing shoes. (xvi) INSURANCE: The bidders shall be responsible for all Accidents/injuries happening to the workmen.
Any aaccident causing minor/fatal injury, partial disability due to any untoward incident or non- adherence to safety and IE regulations or fault in maintaining of internal Electric supply system or on account of any mishandling/wrong operation/ lack of knowledge of safety precautions or on account of any mishandling/ wrong operation/lack of knowledge of safety precautions or on account of any circumstances beyond his/their control, bidders/sevice providers shall be solely responsible fo rsettling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by labour commissioner/court authorities. No claim whatsoever will be enterained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boses to meet any emergency situations (xvii) The rate quoted by the bidders shall be deemed to be including Basic rate [Minimum Wages as notified by Government of India/ State Government/ Local body, which ever is higher], employers contribution towardsEmployees Provident Fund (EPF) liability, contribution towards Employees State Insurance Corporation (ESIC), contribution towards Employees state insurance corporation (ESIC), contribution towards Bonus. Overhead and profit and labour welfare cess (LWC) as applicable depending upon the manpower requirement. This will create onus on the Bidders to applicable depending upon the manpowwer requirement. This will create onus on the bidders to ascertain the relevant rates and quote accordingly. The rates quoted shall be inclusive of all taxes, cess, levies are applicable including GST.
SCHEDULE 'A' PART-XVIII Comprehensive Maintenance of Electrically Operated Lifts for the First Year after Defect Liability Period
Outsourcing of services for operation of electrically operated lift (8 Passengers-02) to serve (G+9 floors) by providing services of one lift operator [Semi Skilled] in each sjift of 8 hours duration per each lift, on all the days in two shifts a day including sunday & holidays, including taking care of from any pilferage, theft or damage etc., First year after defects liability period complete all as specified and as directed.
Comprehensive maintenance of electrically operated Passenger lifts 8 passengers (544 KG) of (G+9 floors) (02 Nos) complete including ARD and all connected components of lift 1st year after expiry of Defect liability period all as specified and directed.
SCHEDULE 'A' PART-XIX: Comprehensive Maintenance of Electrically Operated Lifts for the Second Year after Defect Liability Period
Outsourcing of services for operation of electrically operated lift (8 Passengers-02) to serve (G+9 floors) by providing services of one lift operator [Semi Skilled] in each sjift of 8 hours duration per each lift, on all the days in two shifts a day including sunday & holidays, including taking care of from any pilferage, theft or damage etc., Second year after defects liability period complete all as specified and as directed.
Comprehensive maintenance of electrically operated Passenger lifts 8 passengers (544 KG) of (G+9 floors) (02 Nos) complete including ARD and all connected components of lift 2nd year after expiry of Defect liability period all as specified and directed.
SCHEDULE 'A' PART-XX: Comprehensive Maintenance of Electrically Operated Lifts for the Third Year after Defect Liability Period
Outsourcing of services for operation of electrically operated lift (8 Passengers-02) to serve (G+9 floors) by providing services of one lift operator [Semi Skilled] in each sjift of 8 hours duration per each lift, on all the days in two shifts a day including sunday & holidays, including taking care of from any pilferage, theft or damage etc., Third year after defects liability period complete all as specified and as directed.
Comprehensive maintenance of electrically operated Passenger lifts 8 passengers (544 KG) of (G+9 floors) (02 Nos) complete including ARD and all connected components of lift 3rd year after expiry of Defect liability period all as specified and directed.
NOTES (COMPREHENSIVE MAINTENANCE OF LIFT) : (i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of Oils/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes for the above Lifts. (ii) Preventive maintenance consists of carrying out routine check by skilled personnel as specified in Particular specifications and as directed by Engineer-in-Charge and lubricating to all moving parts, topping parts, topping up of oils as per Lubrication Chart including Material and labour for all consumable and major/minor spare parts. (iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation. (iv) Fortnightly, quarterly maintenance registers shall be maintained and signed by the site engineer and contractor. (v) Load testing shall be arranged by the contractor to the Lift for which repairs were carried out as and when directed by Engineer-in-Charge. (vi) All maintenance works shall be carried out by well qualified tradesmen and supervisor of OEM.
Komal Buildcon Pvt. Ltd.
SVS PROJECTS
SOOD ASSOCIATES PVT LTD
Indus Projects Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid