Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 CrAccepted-Finance AT PLOT NO 373 LANE NO 7 JAGANNATH VIHAR BARAMUNDA BHUBANESWAR 751003 | BHUBANESWAR | KHORDHA | ODISHA | 751003 | ₹5.0 Cr | L1 | Accepted-Finance L1 Bidder through opening of Price Bid (Cover-II). |
| 2 | L2₹5.3 CrRejected-Finance | ₹5.3 Cr | L2 | Rejected-Finance L2 Bidder through opening of Price Bid (Cover-II). |
| 3 | L3₹5.3 CrRejected-Finance | ₹5.3 Cr | L3 | Rejected-Finance L3 Bidder through opening of Price Bid (Cover-II). |
| 4 | Rejected-Technical AT SANABARANGAM GP WARD NIMINA BLOCK POLASARA PIN 761105 DIST GANJAM ODISHA | GANJAM | ODISHA | 761105 | - | - | Rejected-Technical As per DTCN |
| 5 | Rejected-Technical AT P O PANIKOILI DIST JAJPUR 750001 | 750001 | - | - | Rejected-Technical As per DTCN |
Tender Value
₹5.9 Cr
EMD Value
₹5.9 L
Closing Date
3 Dec 2025, 5:00 pmClosed
CCE, Easter (R and B) Circle, Balasore
O/o CCE, Easter (R and B) Circle, Balasore
Building Work
2025_EICCL_121509_10
CCEEC-10/2025-26
National Competitive Bid
Civil Works - Buildings
270 days
Bhadrak
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
₹5.9 L
Yes
30 Apr 2026
19 Nov 2025
4 Dec 2025
19 Nov 2025
3 Dec 2025
19 Nov 2025
19 Nov 2025 - 3 Dec 2025
(a)Second Floor
(b)Terrace Floor
Flyash brick masonary in cement mortar (1:4) in superstructure using flyash bricks of 10" size having a crushing strenght of not less than 75 kg/cm2 including splays cutting circular moulding chamfering & cobelling watering & curing after immersing the bricks in water for six hours before use etc. complete including cost & conveyance of all materials & labour required for the work with all taxes & royalties etc. with all T&P complete in all respect as per specification & direction of the Engineer-in-charge.
(a)Second Floor
Providing Reinforced cement concrete M25 Grade with 20mm & downgrade size clean crusher broken granite chips aggregate of approved quality from approved quarry including hoisting, lowering & levelling in position to required level in each layer not exceeding 15cm thick including frame work where necessary ramming using vibrator to proper slope and levelling curing dewatering if necessary with cost, conveyance taxes royalty labour of all materials and including hire and running charges of machinaries T&P required for the work including supplying and working of pumps and cess as per the specification and direction of Engineer-in-charge.
R.C.C. Roof Beams, Columns, Grider and Bressmer etc.
(a)Second Floor
(b)Terrace Floor
R.C.C. Lintel
(a)Second Floor
(b)Terrace Floor
Chajja, loft, kitchen platform , fins, coping & sill slab
(a)Second Floor
(b)Terrace Floor
R.C.C. Floor and Roof Slab, Landing, Balconies, Projecting Sun Shades and Chajjas up to 4.3 Mtr. Height.
(a)Second Floor
(b)Terrace Floor
R.C.C. Stair Case
(a)Second Floor
Straighting bent up or coiled rods cutting,bending,cranking,hooking,welding or jointing(if required) the M.S. rods or tor steel & binding wires & tying the grills hoisting,lowering & placing in proper position as required for RCC works with cost,conveyance & taxes of MS rods or tor steel & binding wires of 18 to 20 gauge & labour withy all T&P required for the work etc.
(a)Second Floor
(b)Terrace Floor
complete in all respect as per specification & direction of the Engineer-in-charge. (Weight of binding wires will not be considered for payment & payment will be made on weight of M.S. rods or tor steel only).
(a)Second Floor
(b)Terrace Floor
16 mm(5/8") thick cement plaster (1:6) finished smooth to inside surface of brick walls after raking out the joint including watering & curing with cost & conveyance of all materials & labour with T&P required for the work with all taxes & royalties etc. complete in all respect as per specification & direction of the Engineer-in-charge.
(a)Second Floor
(b)Terrace Floor
6 mm thick cement plaster (1 : 4) finished smooth per 1 Sqm. Sand ( Screened & Washed). with all taxes royalties & cess etc, complete as per direction of Engineer-in-charge.
(a)Second Floor
(b)Terrace Floor
Providing 12 mm. thick cement plaster (1:6) finished smooth to inside brick walls after racking out the joints including watering and curing with cost, conveyance, loading, unloading, royalties of all materials, cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer in charge.
(a)Second Floor
Fixing Kota tiles in floors,treads and landings on 25mm thick bed of cement mortar (1:1) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing including cost of tile. complete in all respect as per the direction of Engineer in Charge.
(a)Second Floor
Fixing Kota tiles in dados,skirting and in rises of steps on 12mm thick bed of cement plaster (1:3) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing including cost of tile. complete in all respect as per the direction of Engineer in Charge.
(a)Second Floor
Fixing vitrified tiles in floors treads or steps and landing on 20mm thick bed of cement mortar 1:4 (1cement : 4sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete including cost of precast tiles complete in all respect as per the direction of Engineer in Charge.
(a)Second Floor
Fixing Vitrified tiles in dados,skirting and in rises of steps on 12mm thick bed of cement plaster (1:3) joined with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing including cost of tile. complete in all respect as per the direction of Engineer in Charge.
(a)Second Floor
(b)Terrace Floor
Finishing surface of wall with cement based wall putty ( water Based ) of approved make and finished smooth and even surface to receive painting including cost of scaffolding ,staging including cost of all materials , labour etc.complete and direction ofthe Engineer-in-Charge.
(a)Second Floor
(b)Terrace Floor
Distempering two coats with approved quality of distemper over the interior surface of the walls including all labour charges cost, conveyance & taxes of all materials,labour,T&P required for the work etc. cmplete in all respect as per specification and direction ofthe Engineer-in-Charge.
(a)Second Floor
(b)Terrace Floor
Providing Wall painting with cement primer(oil bound )one coat to the internal wall surface including cost of all materials, labour, Tools & Plant, Brushes etc. complete in all respects as per the direction of engineer incharge.
(a)Second Floor
(b)Terrace Floor
Finishing wall with weather coat to outer plaster surface including cost,conveyance of all materials,labour,T&P required for the work etc. complete asd per specification & direction of the Engineer-in-charge.
(a)Second Floor
(b)Terrace Floor
Providing Wall painting with cement primer(water bound) one coat to the external wall surface including cost of all materials, labour, Tools & Plant, Brushes etc. complete in all respects.
(a)Second Floor
(b)Terrace Floor
Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sumica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete
(a)Second Floor
(b)Terrace Floor
Providing & fitting,fixing dressed seasoned sal wood work framed and fixed (wrought and put up) frames of doors, windows, ventilabours etc complete with cost,conveyance & taxes of all materials & labour with T&P required for the work etc. complete in all respect as per specification & direction of the Engineer-in-charge.
(a)Second Floor
(b)Terrace Floor
Supplying, fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fittings and fixtures.
(a)Second Floor
(b)Terrace Floor
Supplying,fitting & fixing approved quality of fabricated iron door & window shutter & collapsible gate with top & bottom rails in proper position including making holes in walls in proper position including all cost,conveyance,royalty & taxes of all materials,labour,T&P required for the work etc. complete as per specification & direction of the Engineer-in-charge.
(a)Second Floor
(b)Terrace Floor
Painting two coats of enamel over a coat of priming paint to new M.S. iron work including cost primer,sand papering,polishing the surface with cost,conveyance & taxes of all materials & labour with T&P required for the work etc. complete in all respect as per specification & direction of the Engineer-in-charge.
(a)Second Floor
Supplying , fitting and Fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr C/C and stainless steel square pipe bracing of size 32mm x 32mm x 2mm in three rows in staircase as per approved design and specification , buffing, polishing etc. with cost, conveyance, ,es of all materials, labour, T&P, etc. required for the complete in all respects.
(a)Second Floor
Supplying, fitting and fixing of grid mineral fibre ceiling board having size 600 mm x 600 mm x 16 mm of approved design and quality complete with frame and all fitting and fixtures.
(a)Second Floor
(b)Terrace Floor
20mm thick grading plaster (1:4) on roof slab with all taxes royalties & cess etc, complete as per direction of Engineer-in-charge.
25mm dia C-PVC pipes
Supplying all materials, labour,T&Pand providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/04 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge(Supreme/Ashirvad/Oriplast) In Ground Floor 32mm UPVC ASTM Pipe
In 2nd Floor- 32mm dia UPVC ASTM Pipe
In 3rd Floor- 32mm dia UPVC ASTM Pipe
40mm dia UPVC ASTM Pipe
50mm dia UPVC ASTM Pipe
Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge. In 2nd. floor - 250mm thick wall
Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of the Engineer in charge. In 2nd. floor
Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge. 250mm to 375mm thick wall.
Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. In 2nd. floor
Supplying all materials, labour, T&P and fitting and fixing Brass/CP/CPVC/PVC fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge
15mm dia CP Pillar cock (Jaquar) FLR-CHR-5015
15mm dia CP Angle stop cock (Jaquar) FLR-CHR-5053N
15mm dia CP Health Faucet (Jaquar) ALD-CHR-573
15mm dia CP Two way Bib cock (Jaquar) FLR-CHR-5041N
25mm dia brass or gun metal full way valve(shakti make)
32mm dia brass or gun metal full way valve(shakti make)
40mm dia brass or gun metal full way valve(shakti make)
50mm dia brass or gun metal full way valve(shakti make)
15mm dia CP Flange
15mm dia CP Extension Piece
125mm dia CP Gratting
Full Thread Waste Coupl. (Jaquar) ALD-CHR-705
Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. Fixing 2000 Ltr Roto-moulded water storage tank (Syntax Make) 3 layer on the roof of Second floor
Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. European water closet with ‘S’ trap plain (Parryware/Hendware/Cera/Somany/Kerovit)
Supplying all materials , labour, T&P and fixing Vitreous china water closet ,squatting pan ( Indian type W.C. pan / Orissa pattern squatting pan ) duly embedded in cement concrete 1:5:10 using hard granite metal 4cm nominal size including fixing a pair of vitreous china 250mmx130mmx30mm foot rest, fixing 100mm dia hci 'P' or 'S' trap for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge. 580mmx440mm size Orissa pan ((Parryware/Hendware/Cera/Somany/Kerovit)
Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge. 10 litres capacity pvc low level cistern with 32mm dia CP long flush bend Slimline white (Parryware/Hendware/Cera/Somany/Kerovit)
Supplying all materials, labour, T&P and fixing bowl pattern urinal including connecting the urinal with waste pipe by means of white lead mixed with chopped hemp etc all complete as per specification and direction of the Engineer in charge. Half stall urinal DYNA with BI (Hindware) Cat No-60010
15mm dia urinal spreader
32mm dia C.P. dome waste
Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Jaquar Florentine Elbow Action make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste (Jaquar make-Allied), etc all complete as per specification and direction of the Engineer in charge
Integrated Pedestal Basin KYLIS (Hindware) Cat No-91053
Supplying all materials, labour, T&P and fitting & fixing stainless steel AISI 304 (18/8) Library/Kitchen sink with drain board as per IS 13983 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge. 600x450x250 mm stainless steel kitchen sink(Nirali/ Prayag)
Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge(Supreme/Ashirvad/Oriplast) 110mm dia U-PVC SWR pipe
110mm U-PVC Door Tee
110mm U-PVC Plain Tee
110mm U-PVC Y Bend
110mm U-PVC Plain Bend
110mm U-PVC Door Bend
110mm dia U-PVC 'P' trap
110mm U-PVC Cowl.
75mm dia U-PVC SWR pipe
75mm U-PVC Plain Bend
75mm U-PVC Door Bend
Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge
Design Mirror (jaquar /cera)
Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge
600mm Glass Shelf (Jaquar) ACN-CHR-1171N
Supplying all materials, labour, T&P an
d fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge
600mm long CP Towel Rail (Jaquar) ACN-CHR-1111NM
CP Towel Ring (Jaquar) ACN-CHR-1121N
Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP Soap Holder (Jaquar) ACN-CHR-1131N
CP double coat hook (Jaquar) ACN-CHR-1161N
Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter.
Factory made Solid WPC door frame of size 95mmx55mm fabricated. The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royality, taxes etc all complete as aper specification and direction of the E.I.C.
Second Floor
Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1'-6" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge.
Second Floor
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge .
Second Floor :
Supplying all materials, labour, T&P and fixing Granite tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge In Ground floor
Second Floor
Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany / Johnson to be pre-approved 300 x 300mm of size In Ground Floor
Second Floor Floor Area Gents Toilet = 2X4.05x2.45=
Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. Kajaria / Somany 30cm x 45 cm size of
Supplying and fitting-fixing of UPVC Louvers fixed window/ventilator made of (small series) frame 47x50mm & mullion 47x68 mm both having wall thickness of 1.9± 0.2mm and single glazing bead of appropriate dimension (Area upto 0.75sqm) etc.all complete as per direction of the Engineer-in-charge.
In 2nd. Floor = 10x0.60x0.60
Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) pure chill 80 PSS UV of size 750 x 570 x 1350mm hight with water storage capacity 80 liter's along with 2 noa of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in charge Aqua guard pure Chill 80 PSS UV
Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, K.B brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge
Gully trap chamber of size 250mmx250mm with R.C.C cover slab
Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge
Inspection chamber Inside size 760mmx760mmx460mm
RCPC Cover (18" round)
Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge
Man hole chamber Inside size 910mmx910mmx910mm
RCPC Cover (24" round)
Supplying all materials, labour, T&P and constructing soakway pit of the following size with precast RCC rings joined loose, gravel backing in the rear of well steining, precast RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including cutting hole in the rings for inlet pipe,earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge
RCC rings soakway pit 1.22m dia x 2.10m deep
Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) i
ncluding jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.
110mm dia u-pvc pipe alround concrete
160mm dia U-PVC Alround Concrete
Construction of 50 users RCC septic tank- 2 No
Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge.
Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. 2x6.10x2.70x0.30
Excavation of foundation in laterite rock or any hard rock (other than granite or disintegrated rock) removed by chiselling including dressing and levelling the bed not exceeding 1.50 mtr. in depth and depositing the soil within initial lead of 50 mtr. and as per specification approved by the Department.
Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge.
Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
R.C.C floor and roof slabs up to 4.30m height
R.C.C beams,columns,girder and bressmer etc.
Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
R.C.C beams,columns,girder and bressmer etc.
Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
In ground floor
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge
Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge.
Dewatering with 5 H.P diesel engine pump during excavation
Supplying all materials, labour, T&P and fitting and fixing S.W.Tee of size 150mx150mx150m as per P.H.D. specification and direction of the E.I.C.
Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete.
Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. (Supreme/Ashirvad/Oriplast)
110mm diameter U-PVC SWR pipes(Supreme/Ashirvad)
110mm U-PVC cowl
Sinking of 150mm size tube well through hand boring( water jet) method)
(Sinking of 150mm size tube well through hand boring( water jet) method) Suplying all materials, labour, T&P and setting up boring equipments including erection of suitable staging for installation of the required size of tube well, dismantling and removing the same after complection of the work, including transportation of the boring equipments, cleaning and levelling the site, excavation of mud pit, channels etc, levelling of site all complete as per direction of Engineer in charge
Supplying all labour, T&P and transporting the boring pipes, top casing, grouting pipes, PVC pipes and fittings, PVC well screens, cement, bentinite and gravels etc to the worksite including loading and unloading etc all complete as per direction of the Engineer in charge.
Supplying all labours, T&P and drilling pilot bore not less than 102mm dia, without casing pipes in all kind of soils and rocks for the following depths excluding supply of necessary boring pipes including supply of necessary cutting equipments, extra sockets ( whenever required) etc and withdrawing the boring pipes, washing and keeping the bore logging if required all complete as per direction of Engineer in charge Drilling pilot bore from 0 to 360 metres
Supplying all labour, T&P and reaming the pilot bore to the following sizes and depth without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc all complete as per direction off Engineer in charge. Reaming 100mm to 150mm dia from 0-360 mtr
Reaming 150mm to 200mm dia from 0-360 mtr
Reaming 200mm to 300mm dia from 0-360 mtr
Supplyimg all labour, T&P and jointing materials & lowering the 300mm d
ia top casing pipes into the position and removing the same after all complete as per direction of Engineer in charge From 0-360 mtr
Supplying all labour, T&P and jointing materials and lowering the pvc casing pipes, fittings and well screens in position, including fitting and fixing of centraliser, cutter plug and washing the bore all complete as per direction of Engineer in charge 150mm dia PVC casing pipe from 0 to 360 metres
Cost of 150 mm dia PVC ASTM pipe(sch-80)
Cost of 150mm dia Slott Cutting
150 mm dia C.I.end/top cutter plug
Cost & Conveyance of bentonite powder
Supplying all materials, labour, T&P and packing the bore with washed gravel of river shingles of required size and specification around the well screen and pipe etc all complete as per the direction off the Engineer in charge. Labour charges
Cost and Conveyance of gravel
Supplying all materials, labour, T&P and packing the bore with river sand over the gravel pack all complete as per the direction of the Engineer in charge. Labour charges
Cost and Conveyance of sand
Supplying all labour, T&P including developing the tube well with compressor ( supplied by contractor ) continuiously worked till clear & adequate discharge is obtained from the tube well including supply and use of necessary equipments and labour as per direction of the Engineer in charge. Labour charges
Supplying all materials , labour, T&P and providing & fixing to wall or ceiling and floor pvc pipes confirming to HDPE pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction. 32mm dia HDPE Pipe
Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submerisble electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trail running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge 1.50 three phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.P.M with outlet dia of 32mm
DOL Control panel
32mm dia steel short piece
Well cap
50mm size CI bracket
2.50 sqmm flat cable
Steel rope with cover
20mm dia rigid UPVC pipes
Supplying all materials, labour, T&P and providing & electrification to submerssible pump sets and service connection including fitting fixing of electric board & Switch etc all complete as per direction of the Engineer in charge.
Supplying all materials, labour, T & P and constructing Bore well protection chamber of the inside size 650x650x1000 hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g. chips, 12mm thick cement plaster (1:4) inside and outside, RCC cover slab in (1:1.5:3) using 12 mm size h.g. chips, earthwork in excavation in all kind of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction pof the engineer in charge.
Group A
Group B
Group C
Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/Schnider(Zencelo)//PANASONIC(VISION)
Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C. on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision)
Supply, delivery and laying of following sizes of 2 mm Wall thickness rigid PVC Conduit Concealed in Wall/ Column/ Roof Slab of the Building or mounted on surface along with other accessories and 18 SWG GI Fish Wire complete for Telephone / TV / Computer / Circuit or Sub main wiring as required & as per Direction of Engineer-In-Charge.
20 mm dia.
25 mm dia.
computer Lab
Supply ,laying & installation GI raceways 300 mm x 38 mm GI Race way with fixing bracet coupler made of pre-galvanished sheet (DX51D Z120 MAC) with thickness of 1.5mm for distributing LV and ELV cabling in screed floors installations. Can be combined with junction boxes, backboxes (floorboxes) for wiring devices, fixing and coupler accessories. Consist of body & cover. Cover fitted on to the body with screws & can be opened easily if required. Particularly suitable for applications requiring EMC screening. Protection level should be IP 20 & IK 08. Standard length should be 2.44 mtrs. Confirms to standard EN 60-670, EN 50 085 - 2 - 2 & IEC 61534-22. Resistance to vertical load applied through small surface area should be 1500 N & Resistance to vertical load applied through large surface area should be 3000 N. Linear impedance in mili ohm /m of metal raceways length 5 mili ohm/m.Race ways should be supplied with complete accessories i.e. fixing brackets & couplers for joining raceways from the same manufacturer. Make:Legrand/MK/penduit .(computer Lab).
Supply and laying of 4 pair Cat6 U/UTP Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs
separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance ≤ 9.38 Ω/100m Max., Cable support Delay Skew: < 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 Ω @100 MHz. and Propagation Delay @250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Make: Systimax, Legrand, Panduit
SITC of Cat 6, 24-port loaded, 1U Modular Jack Panel Should accommodate Cat6 with Rear Cable Management and Front removable Tooless Information outlet. Should have easy clip management with labels and clear label covers, Made with of Dicast Aluminium Alloy Material and Non Corrosive with Cat6 toolless RJ45 x 24 ports with color code front panel with patch cord locking. Make: Systimax, Legrand, Panduit
Supply and Installation of Cat6 I/O single port with Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Tyco / Legrand / Penduit
SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 @ 250Mhz & CAT6A @ 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold > 0.8 μm. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit
SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP
SITC of Cat6 UTP 24 AWG Patch Cord Patch cord: 6 UTP Patch Cords are Factory Tested for Better Quality and Suitable for the High Speed Data Transmission. Complies to the Standard ANSI/TIA/EIA-568-C.2 Standard. Supports Data Networks Speeds Up to 10/100-Base-T and 1000-Base-T. Available In LSZH Jacket- Reduced Toxic Gasses Emitted During Combustion , RJ45, 8P8C, 2 FORK 50μ’’ Gold Plated Contacts , 100% Factory Tested , Transparent Boot Cable Assemblies. Make: Systimax, Legrand, Panduit(1 mtr length)
1mtr Lenghth
2mtrs Length
SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit
SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : <= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PC>= 45db, UPC>=50db, APC>=60db. Make: Systimax, Legrand, Panduit
SITC of 24U 600/650D UL Listed Floor mount Rack with Front perforated door with 3 point lock, Rear mesh door with Cam lock and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray - Ventilation - 495W - 375D and H/W screw920sets). Make:Valrack, Rittal, Legrand
SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand
Supply, installation, testing & commissioning of one no. 10KVA 3 phase UPS System with inbuilt isolation transformer to work in parallel redundant configuration with SMF Battery for 30 minutes back up along with all accessories with each UPS. The UPS should be IGBT based with 0.99 input power factor, 5% input THDi, unity output power factor, > 91% overall efficiency, with inbuilt static and m
aintenance bypass switch, operating temperature 0 to 50 deg C, altitude 3000 mtr , with Transient Voltage Surge Suppressor - 25KA, 3 phase TVSS having all ten Mode Protection (L-L / L-G / L-N / N-G), response time < 0.5 nano sec., EMI/ RFI attenuation: 40 dB Certification - Listed with UL1449 should be provided with each UPS. TVSS should be of same make as UPS. UPS should have inbuilt switch gear for input, output, Maintenance bypass, auto static bypass & Battery. UPS should have Self-capacity test feature – UPS should have the provision to test run in its full capacity without external load. Make: Schneider / Vertiv / ABB
Submains:Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2nos single core 10 sq. mm copper wire for phase and neutral and 01 nos of single core 4 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6)
Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.
Supplying and fixing following way, Three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way, TPN DB Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
Supplying and fixing following rating, 40 amp double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 300 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, 63 amp 4pole MCB , (Three phase and neutral), 415 V having a sensitivity current 10 KA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
MAIN PANEL BOARD
Supplying, Installing, Testing and Energizing MS Cubical type Panel Board made of 2 mm thick CRCA Sheet with Hinged Door duly Fabricated with required MS Angle and Channels of adequate size, duly treated and Powder Coated (shall have Hinged Door at the Front and Detachable Plates at Back if requirement and at Top / Bottom for Cable / Wire Entry / Exit as per the Direction of Engineer-In-Charge and approved GA Drawing with following provisions. MAKE-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS) Incoming: 200 Amp. 4P MCCB 50 KA with TMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS) - 1No 250 AMP Motorized 4 WAY CHANGEOVER SWITCH 1 NO Equiments: 4 Nos. 200 Amp. AL Bus Bar coated with PVC Heat Shrunk Sleeve (Colour Code). 1 No. VAF Digital Meter.3 Nos. RYB LED Indicator. 3 Nos.250 / 5 Amp. C.T. Operated. Outgoing: 3 Nos 125 AMP 4P MCCB 36 KA FOR UPS /floor PANEL,2 Nos 100 AMP 4P MCCB 36 KA with TMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS) , ,3 Nos 32 AMP DP MCB 10 KA,2 NOS 63 AMP 4P MCB 10 KA ,.With spreadentinle & cable alloy. 1 nos. Multifunction meter & SPD 4 POLE TYPE 1+2 50 KA .All MCCB should have Ics = 100% of Icu Complete duly factory wired as per SLD and panel should have proper earth by suitable rated copper flat.
including all accessories and connectionas per specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge.Make: L&T,ABB,SIEMNS
FLOOR ups Panel:
Supply, delivery, installation, testing & commissioning of Incoming: 125Amp. MCCB 36 KA 1 No., R Y B LED Indicator- 3 Nos., 125Amp. Electrolytic Copper Bus Bar - 4 Nos. 1no. Digital multi function meter Outgoing: 40 AMP DP MCB 10 KA 7 NOS, including all accessories and connectionas per specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge.Make: L&T,ABB,SIEMNS
Floor light panelSupply, delivery, installation, testing & commissioning of Incoming: 125 Amp. 4P MCCB- 25 KA with TMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS) 1 No., R Y B LED Indicator- 3 Nos., 100 Amp. Electrolytic Copper Bus Bar - 4 Nos. 1no. Digital multi function meterOutgoing: ,40/63 Amp. 4P MCB 10 KA -7 Nos. ll MCCB should have Ics = 100% of Icu Complete duly factory wired as per SLD and panel should have proper earth by suitable rated copper flat. including all accessories and connectionas per specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete as per the direction of Engineer-in-charge.Make: ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS)
FITTINGS & FIXTURES:
SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /halonix/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Halonix/Bajaj).The luminaire should be Replacement Warranty will be 2 years
Supplying and fixing of Energy efficient recessed mounted LED luminaire made up of CRCA powder coated housing, bottom opening clean room LED luminaire of 600 X 600 x 65 mm size with of 36 W and system lumens output not less than 3600 lumens , IP65 ,dust free & zero maintenance , anti glare high transmittance PMMA diffuser , operating volatge range 150-265 V, high performance potentiometric electronic driver for zero maintenance , 2.5 KV internal urge protection, L70 B 50: 50,000 hrs., CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,,IP 65 protection complete with all other accessories suitable for operation on 230 V, 50 Hz supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2years. .Each CLEAN ROOM FITTING .
SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
SITC installation of 10 W Bulkhead light complete assembly With supply of required T&P and making connection from the suitable point outlet as per the Direction of Engineer-In-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(With fan Regulator)
Supply, delivery, installation & testing of following 300 mm EXHAUST FAN 1400 RPM. Sweep & Speed Exhaust Fan on Existing Sheet Metal Switch Board including loop connections and making good the damages caused complete as required and as per direction of Engineer-in-charge(Make-Khaitan/ Halonix/USHA/Pansonic/Bajaj/Eq make)
EARTHING:
Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
Extra for using salt and charcoal for G.I or copper plate earth as required and making good the damages caused complete as required and as per direction of Engineer-in-charge
Providing and fixing 8 SWG COPPER wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required and making good the damages caused complete as required and as per direction of Engineer-in-charge
Supplying,installation,testing & commissioning Of Earthing with GI earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge. The entire earthing system should be Replacement Warranty will be 2 years
CABLE
Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 120 sq.mm but not exceeding 400 sq.mm direct in ground in the same trench in one , sand cushioning, protective covering and refilling the trench etc. as required.
Supplying, laying & testing of following size of PVC insulated XLPE shethed / strip armoured aluminium / Copper conductor power cables of 1100 volt grade laid directly unground with sand cushioning, brick protection, clamped on surface of the walss / columns / existing RCC / inside masonry cable trenches / on the cable tray /throuth G.I Pipes / hume pipes / PVC pipes as the case may be, including cost of shaddles/ clamps/ markers etc but excluding the cost of G.I. Pipes / Hume pipes cpmplete with making good to the damages as required and as per direction of Engineer-in-charge. MAKE: FINOLEX/ KEI/ POLYCAB/HAVELLS/RR CABLE
150 mm2 3 1⁄2 Core , Al Arm
oured , XLPE Cable FOR PANEL
50 mm2 3 1⁄2 Core , Al Armoured , XLPE Cable FOR PANEL
Supply of all materials like cable lugs, gland etc as required & terminal of below mentioned cable complete as per required technical specifications & direction of EIC
150 mm2 3 1⁄2 Core , Al Armoured , XLPE Cable
50 mm2 3 1⁄2 Core , Al Armoured , XLPE Cable
Supplying of following Materials
First Aid Box.
Shock Treatment Chart (Odia / Hindi & English).
Supply installation of 33kV 3mm thick Class-C Rubber Mat as per IS-15652 and complete as per direction of Eng-in-charge.(Size-10mx1m)
Supplying, installation, testing and commissioning of ABC type fire extinguishers of 6 kg capacity including cost of all material & labour etc complete.(Make: SUPREMEX / CEASEFIRE/MINIMAX)
Danger Board.
Supplying, installing, testing and commissioning of MS Pipes, ERW confirming to IS 1239 Pt - I HEAVY grade up to 150mm dia and pipes 200mm dia and above shall be M.S as per IS: 3589 with painting, suitable type of supports, anchor fasteners, bolts nuts, clamps, "U" bolts, malleable specials such as Reducers,Tees, elbows, flanges. Including cutting, Welding, fixing in / on walls, ceiling by using suitable supports etc, complete.Make-TATA/SAIL/JINDAL
100 mm dia
80 mm dia
Supply,Installation,Testing & Commissioning of Stainless steel Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single headed , oblique type, as per IS :5290/93 and as per direction of Engineer-in-charge.Make: KIRLOSKAR/WILO/LUBI/EQ
Supplying and fixing 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with Gl wire,rivets etc. conforming to lS 636 (type-A) as required.Make: KIRLOSKAR/WILO/LUBI/EQ
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.19 MB
DTCN10.pdf
Tender Documents • 1.53 MB
BOQ_565399.xls
BOQ • 0.48 MB
Download all tender documents and submit your bid