Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.3 LAccepted-AOC 116 SARAT BOSE LANE P O RAJBARI COLONY KOLKATA 700081 | 24 PARAGANAS NORTH | WEST BENGAL | 700081 | L1 | Accepted-AOC The agency quoted lowest amount | |
| 2 | L2₹46.3 L+₹7,650 (0.17%)Rejected-Finance | L2 | Rejected-Finance The bidder is L2 | |
| 3 | L3₹47.5 L+₹1.3 L (2.71%)Rejected-Finance | L3 | Rejected-Finance The bidder is L3 | |
| 4 | L4₹50.0 L+₹3.7 L (8.02%)Rejected-Finance 111 YADAV ELECRIC MARKET GB MARG LUCKNOW LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | L4 | Rejected-Finance The bidder is L4 | |
| 5 | L5₹50.2 L+₹4.0 L (8.56%)Rejected-Finance P 27 1 RASHTRAGURU AVENUE DUM DUM KOLKATA 700028 | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L5 | Rejected-Finance The bidder is L5 |
Tender Value
₹59.4 L
Closing Date
27 Sept 2021, 5:00 pmClosed
AGME E
NSCBI Airport Kolkata
Renovation minor rectification of feeder panels LT panels and distribution panel at various location like AAI residential Colony IRP Plant and Lagoons at Kolkata Airport
2021_AAI_88047_1
AAI/EMD_IV/Reno_panel/2021
Open Tender
Electrical Works
Works
180 days
NSCBI Airport Kolkata
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,120
Exempted
3 Jun 2022
13 Sept 2021
1 Oct 2021
14 Sept 2021
27 Sept 2021
14 Sept 2021
14 Sept 2021 - 16 Sept 2021
Amount
Fabrication, treatment & painting of damaged portion of cabinet Box in the existing LT panel as per the site requirement upto the satisfaction of Engg-in- charge etc. complete as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
Supplying and fixing 63 A rating, 240/415 V, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Double pole
Dismantling of existing Fedder/ LT panel of various sizes with all end terminations and shifting the same to AAI store as per the instruction and complete satisfaction of Engg-in-charge etc. complete as required.
Supply of 20 watt LED tube light fixtures ( 6500 K) with integral LED driver suitable to be operated with 230 V AC, diffuser / reflectors, connecting terminal, internal wiring etc. complete with all fixing accessories as required. (Similar to LHEXBLP7PN1W020 or equivalent model of approved make.)
Supply of 1200mm sweep ceiling fan with energy rating not less than 5 star. (Make:Orient, Model: IS-5 or equivalent model of approved makes)
Supply of 300mm dia, 900 RPM Metal Blade heavy duty exhaust fan suitable for single phase 230v.50Hz A/C supply complete with all accessories ertc. Complete as required
Supply of following electrical components with all accessories suitable for fixing in feeder panel meant for borewell pumps etc. complete as required
3P MNX-40 Power Contactor as suitable to site requirement.
3P MNX-50 Power Contactor as suitable to site requirement.
4P MCX-32 Power Contactor as suitable to site requirement.
3P ML-2 Power Contactor as suitable to site requirement.
3P ML-3 Power Contactor as suitable to site requirement.
3P ML-1.5 Power Contactor as suitable to site requirement.
ML-2/ML-3 relay as suitable to site requirement.
MN-5 relay as suitable to site requirement.
MN-2 relay as suitable to site requirement.
ML- 1 relay as suitable to site requirement.
ML-2 spare kits as suitable to site requirement.
ML-3 spare kits as suitable to site requirement.
MNX-40 spare kits as suitable to site requirement.
MNX-50 spare kits as suitable to site requirement.
VPG-D1 Single Phase Preventor as suitable to site requirement.
VSP-2 Single Phase Preventor as suitable to site requirement.
Add On Block for Power Contactor like MNX-40/MNX-50/MNX-32 as suitable to site requirement.
Analog Timer switch as suitable to site requirement. as suitable to site requirement.
Rotary Switch as suitable to site requirement
3 Phase Analog ammeter( 0-250A ) Ammeter as suitable to site requirement.
3 Phase Analog Voltmeter ( 0-500 Volts) as suitable to site requirement.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 300 sq. mm (70mm)
3½ X 150 sq. mm (50mm)
3½ X 95 sq. mm (45mm)
3½ X 70 sq. mm (38mm)
4 X 50 sq. mm (35mm)
4 X 25 sq. mm /4 X 16 sq. mm (28mm)
Supply of 12 V, 180 AH Battery ( Make: Exide,Model -Xpress ) or equivalent make as per AAI approved makelist suitable for cranking of 38HP Kirloskar Make diesel Engine set complete with all accessories as required.
Supply of 1.1KV, Power Cable with Stranded compact Sector shaped Aluminium Condector, XLPE Insulated, Colour Coded, Cores Laid up, Thermoplastic tape Inner Sheathed, Singel layer of Galvanized Flat sheet Strip Armoured and overall FRLS PVC Type (ST-2)Outer Sheathed conforming to IS: 7098 (Part-1) - 1988 as amended up to date
3.5 C X 120 Sq.mm.
3.5 C X 50 Sq.mm.
4 C x 16 Sq.mm.
STAR ENTERPRISE
Rekha Enterprises
Industrial Traders
Youngmen Traders
Mukherjee Commercial Enterprise
SHREE GOURI ELECTRIC ENTERPRISE
BR Power Control and Automation Services
SAHA COMMERCIAL CONSTRUCTION
M/s J.K. Electric Engineering Works
RN Electro Power Pvt. Ltd.
stage.html
html • 0.08 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .