| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.8 CrAccepted-AOC | ₹1.8 Cr | L-1 | Accepted-AOC Accepted |
| 2 | L-2₹1.9 Cr+₹5.4 L (3.01%)Rejected-AOC | ₹1.9 Cr+₹5.4 L (3.01%) | L-2 | Rejected-AOC Rejected |
| 3 | L-3₹2.1 Cr+₹25.6 L (14.3%)Rejected-AOC SCO 36 SECTOR 7 C MADHYA MARG CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | ₹2.1 Cr+₹25.6 L (14.3%) | L-3 | Rejected-AOC Rejected |
| 4 | L-4₹2.1 Cr+₹27.3 L (15.2%)Rejected-AOC | ₹2.1 Cr+₹27.3 L (15.2%) | L-4 | Rejected-AOC Rejected |
| 5 | L-5₹2.3 Cr+₹54.6 L (30.4%)Rejected-AOC | ₹2.3 Cr+₹54.6 L (30.4%) | L-5 | Rejected-AOC Rejected |
Tender Value
₹99.5 L
EMD Value
₹1.3 L
Closing Date
14 Oct 2020, 5:00 pmClosed
EE Rampur
JSD Rampur
LWSS from Kurpan Khad to Bankhari G/O villages under sub Tehsil Nankhari
2020_HPIPH_41463_1
NoJSD-RMP-E-Ten/20-6448-6498dt 07.10.20
Open Tender
Civil Works
Item Rate
365 days
Rampur
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,500
EE Rampur
₹1.3 L
27 May 2021
8 Oct 2020
15 Oct 2020
8 Oct 2020
14 Oct 2020
8 Oct 2020
Amount
Supply errection, testing and commisioning with automation of horizontal spindle,horizontal split, redial split Single/Multistage centrifugal pumps of standard make such as KSB/Mathar & Platt/Jayoti/Kirloskar and other approved make confirming to BIS 1520-1980 (latest with upto date ammendments) read with BIS 9137-1978 or latest to handle clear water having turbidity up to 50 ppm. with impelleres,casing ring performing funnel & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel/ mild steel to BHEL /Kirlokar/NGEF/Crompton/ Siemen/Jyoti GEC make slip ring/squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below i/c cost of all accessories in all leads an lifts and lifts as per entire satifaction of Engineer- in- charge.
Stage-1 3 Nos. Pump set ( ie 2 Nos. working simultaneously & 1 No. Pump stand by
A) SITE CONDITIONS i) Location of site= At Duttnagar ii) The altitude of place in which the motor is untended to work in ordinary service if it exceeds 1000 Mt= 1058 Mtr. iii) Humidity= Whether generally remains clear during monsoon season. iv) Nature of atmosphere=As normally encountered in Himalyan Range v). Detail of quality of water= Clear cold water. vi) Water free from sand or not= Yes vii). Water corosive or not= Not viii). Turbidity (if any)= Up to 50 PPM ix). NPSH available= Positive suction. x). Any other information or requirement=
B OPERATING CONDITIONS i). Type of current= AC three/ single phase ii). Operating frequency= 50HZ iii). Rated voltage= 400(+/-)10%volts iv). System of earthing if any to to be adopted.= Double loop earthing as per BIS 3043-1987 latest with upto date amemndements v). No. of working hours per day= 16 hours vi). Speed of revolution in RPM= to be quoted by tenderer vii). Direction of rotation= to be quoted by the tenderer viii). The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service.= 35 Degree Centigrade
C) MOTOR i) Ref. to BIS code= BIS 325-1978 read woth 900-1992 (latest) with upto date amendements. ii). Type of enclosure of motor= SPDP (as per BIS 4691-1985 (latest). iii). Type of duty= Continous iv). Mechanical out put in KW= Suitable for driving centifugal pumps re quired for duties specifiation against pumps to avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. v). Class of insulation= Class-B vi). Max.permissible temp.rise of motor reqd. if different from given in B(viii) above = ----- vii). Particulars of test reqd. & where they are to be conducted.= As per terms and conditions viii). Particulars as to whether voltage limiting divice will be employed= At S/star delta starter oil immersed fully automatic to be installe between bus bar & motor shunt capacitor is also proposed to be installed for improving the power factor at site. Note:- Star delta starter upto 37.5 KW ATS between 37.5KW to 50 KW & Starter rotor with sluip ring motor beyond 50 KW ix). Motor whether squirrel cage or slipring= Squirrel cage/slipring Note:-Squiareel cage upto 65HP and slipring above 65 HP x).Details of shaft extension reqd.= Just sufficient to prode diretc drive by flexible coupling to pump. xi). Type of slip ring gear whether continouly rated or for=Continously rated for squirrel cage/slipng starting purposes only & whether to be fitted with brush lifting or short circuting arrangements or both if interlocks are required. xii). Breakway torque in terms of rated l= Breakway torque to be given by the tenderer but the current which may be taken from the supply with the starting current should not exceed 2.5 of time of the starting apparatus in circuit. full load current, xiii). Nature of load & any information regarding the = Sufficient to work the pump offered driven machine which has a bearing upon the torque reqd.during the accelearted period, the kinetic energy of the moving parts to be accelarated & No.of starts during a specified period. xiv).. Where possible fault capacity of the system to which the motor is connected.= The motor should be able to withstand intial current of 2.5 times teh rated current for two minutes without suffering damages or permanent deformation.
D) PUMP (BIS 1520-1980)read with BIS 9137-1978 both latest with upto date ammendments a). Nos of pumps reqd.= 3 Nos pumps Two will act simultaneously and one as standby. b). Spare parts required= For two years normal maintenance as recommended by manufacturer. c). Optional fittings reqd.= Air cock for exhausting air from each stage.
E) PUMP OPERATING CONDITIONS i). Capacity = 15.44 LPS ii). Total head in Mtrs. If total head is not known then following details be provided:- 582.00 i)Static head /Discharde Head = 582.00 Mtr ii)Minimum depth of water= Negative suction 5.00 Mtrs. iii)Variation in water level=- ---Mtrs iv)Ground level to max.level= --Mtrs v)Ground level to delivery point= Mtrs vi)Pressure in the suction tank= Kg. cm/2 vii)Pressure in the delivery tank=Kg cm/2 iii). Length of R/Main= 6250 Mtr iv). Dia of R/Main= 150mm v). Drive arrangement= Direct through flexible coupling on a comman base plate vi). Drive type= Electric driven. vii0. NPSH reqd.= to be quotated by the tender viii). Limits of total head in which the pump is reqd. to operate.= (-)15% to (+)10% of total head ix). Suction/delivery size of pump= To be specified by the tenderer x). Efficiency of pump at= To be specified by the tenderer a) duty head= b) (+)10% head c) (-)15% head Material of construction= To be specified by the tendered (manufacturers certificate to be appended.
Material of construction
Programmable Logic Controller for automatic motor and pump control with text HMI,multiple timingoption setting,Seprate 12 vde SMPS UPS backup meeting the protection and control criteria enclosed in technical specification with data logger capable of generating long run report related to current voltage, energy consumption discharge running hours frequency and other pump/ motor characteristics full bore electromagnetic flow meter may be provided for automation i/c all leads an lifts and lifts as per entire satifaction of engineer in charge.
Providing & fixing suitable soft starter of approporiate rating for motor specified in technical specification for the purpose of controlled starting & stoping of pump with upper and Lower voltage and current limit i/c all leads an lifts and lifts as per entire satifaction of engineer in charge of standard make such as MEI/Kilburn/Jyoti/ Siemens/Larson & Tubro conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling as the case may be with single phase preventor as per IS 1246 (Part-1)-1963 with up to date ammendments.
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.( Each pannel board comprising below mention accessories)
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen / Havells make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with up to date ammendment i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
MCCB of appropriate capacity suitable for above specified capacity of Kilburn/LT/LK/MEI/ GEC/ Havells/ Diamond of standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with internal oil filling whenever required and neutral linked under voltage release i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Indicator for main ON-OFF system standby-overload run sump empty -full RYM phase i/c all leads and lifts as per entire satifaction of Engineer-In- Charge
Earth leakage circuit breaker/relay of recommended make such as Kilburn/L&T/MET/GEC and any other approved make conforming to BIS-2516-1977 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side compatible with automation system i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Hour run meter of reputed make of digit capacity conforming to BIS-722 latest edition / recommendation.
Suitable three phase voltage monitor relay with all protections & usual indicators with electric sirens against single phasing, No/low voltage, high voltage & overloading & phase voltage difference as per IS-3842 with up to date ammendments.
Change over Switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable capacity conforming to IS:1248 (P-V)-1983 with up to date ammendments
Float type two point low/high level monitering system of water supply tank(sump well) integrated with programmable logic controller for dry run protection and automatic pump control i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Easy Fault Diagnostics with led disply for main supply missing or <75% phase loss reversal & other error, i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Automatic phase reversal rectifeir of appropriate capacity suitable for above specified motor i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Frequency meter for AC Supply of appropriate capacity suitable or above specified motor i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Motor protection circuit breaker for 3 phase/3 wire under voltage/over voltage protection , short circuit protection,overload protection,phase loss,phase reversal protection and motor disconnect function/ i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Rust free powder coated control panel suitable for housing all the above listed electric and electronic componnents i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Providing and fixing of Kirloskar/Leader/KSB/fouress/pellicon/ Gled / BHEL make of cast steel double flanged Automated/ self actuated sluice valve having size one size higher dia than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump (including one No for common header) i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
(NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 600 ASA (seat pressure 105 Kg/cm^2) as per BS 1414 (API 200).
Providing and fixing of Kirloskar/Leader/KSB/pelicon/Fouress make of suitable size cast iron/cast steel double flanged Automated/ self actuated swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 600 ASA (seat pressure 105 Kg/cm^2) as per BS-1414 (API200) .
Providing and fixing of Kirloskar/Leader/KSB/Pelocon/Fouress make of suitable size cast iron /Cast Steel double flanged automated / self actuated swing check type reflux valve having bye pass arrangement & size equal to dia of R/main as mentioned in item No.1 (c) for withstanding nominal seat pressure as per Rising main. i/c all leads an lifts and lifts as per entire satifaction of engineer
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 600 ASA (seat pressure 105 Kg/cm^2) as per BS 1414 (API 200) .
Providing and fixing of Kirloskar/Jyoti/Standard/Kilburn make cast iron flanged screwed type Automated / self actuated foot valve with strainer of dia equal to dia of suction pipe conforming to BIS 4038-1986 or latest with up to date ammendments. i/c all leads an lifts and lifts as per entire satifaction of Engineer-in- Charge
Providing and fixing of Kirloskar/Leader/KSB/Pelocon/Fouress make cast iron flanged Automated / self actuatedv Sluice valve for suction pipe having size one or two size larger than suction size of pump such that valocity of flow is not more than 3.00 mtr/sec. with strainer of dia equal three to four times of dia of suction pipe conforming to BIS/API-standards or latest with up to date ammendments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
NOTE:- The C.I sluice valve PN 1.6 as per IS 2906-1998).
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. i/c all leads an lifts and lifts as per entire satifaction of engineer (for 3 Nos. Pump Set. )
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge. (for 3 Nos. Pump Set. )
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,copper wiring & 32x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer) i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Providing and fixing of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Providing and fixing of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Errection of all equipments i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Prov and fixing cast steel double flanged Automated / self actuated non returning valves of approved make makes such as Kirloskar, BHEL, Kilburn, KSB,Leader, GLED as per BIS 1868 including all leads and lifts complete in all respect.
150 mm dia ASA-600
AUTOMATION AT MAIN CONTROL STATION DUTTNAGAR:-
Providing & Fixing Centerlised automation system at main water treatment plant, consisting of fully wired pannel with master PLC system on Internet, Flow meter , Level switch and pump interface within all leads & lifts as per direction of Engineer- In- Charge.
Providing & Fixing PC with printer , licesned operating system windows with latest SCADA system with Web functionality within all leads & lifts as per direction of Engineer- In- Charge.
Providing & Fixing High and Low level switches Float Type for Fresh Water and treated water tanks within all leads & lifts as per direction of Engineer- In- Charge.
Providing & Fixing Raw Water Magnetic Flow meter for water transfer from Natural resources to Raw Water storage Tanks within all leads & lifts as per direction of Engineer- In- Charge.
Stage- IInd
Supply errection, testing and commisioning with automation of horizontal spindle,horizontal split, redial split Single/Multistage centrifugal pumps of standard make such as KSB/Mathar & Platt/Jayoti/Kirloskar and other approved make confirming to BIS 1520-1980 (latest with upto date ammendments) read with BIS 9137-1978 or latest to handle clear water having turbidity up to 50 ppm. with impelleres,casing ring performing funnel & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel/ mild steel to BHEL /Kirlokar/NGEF/Crompton/ Siemen/Jyoti GEC make slip ring/squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below i/c cost of all accessories in all leads an lifts and lifts as per entire satifaction of Engineer- in- charge.
Stage-2 3 Nos. Pump set ( ie 2 Nos. working simultaneously & 1 No. Pump stand by
A) SITE CONDITIONS i) Location of site= At Hallana in IPH Division Nankhari ii) The altitude of place in which the motor is untended to work in ordinary service if it exceeds 1000 Mt= 1640 Mtr. iii) Humidity= Whether generally remains clear during monsoon season. iv) Nature of atmosphere=As normally encountered in Himalyan Range v). Detail of quality of water= Clear cold water. vi) Water free from sand or not= Yes vii). Water corosive or not= Not viii). Turbidity (if any)= Up to 50 PPM ix). NPSH available= Positive suction. x). Any other information or requirement=
B OPERATING CONDITIONS i). Type of current= AC three/ single phase ii). Operating frequency= 50HZ iii). Rated voltage= 400(+/-)10%volts iv). System of earthing if any to to be adopted.= Double loop earthing as per BIS 3043-1987 latest with upto date amemndements v). No. of working hours per day= 16 hours vi). Speed of revolution in RPM= to be quoted by tenderer vii). Direction of rotation= to be quoted by the tenderer viii). The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service.= 35 Degree Centigrade
C) MOTOR i) Ref. to BIS code= BIS 325-1978 read woth 900-1992 (latest) with upto date amendements. ii). Type of enclosure of motor= SPDP (as per BIS 4691-1985 (latest). iii). Type of duty= Continous iv). Mechanical out put in KW= Suitable for driving centifugal pumps re quired for duties specifiation against pumps to avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. v). Class of insulation= Class-B vi). Max.permissible temp.rise of motor reqd. if different from given in B(viii) above = ----- vii). Particulars of test reqd. & where they are to be conducted.= As per terms and conditions viii). Particulars as to whether voltage limiting divice will be employed= At S/star delta starter oil immersed fully automatic to be installe between bus bar & motor shunt capacitor is also proposed to be installed for improving the power factor at site. Note:- Star delta starter upto 37.5 KW ATS between 37.5KW to 50 KW & Starter rotor with sluip ring motor beyond 50 KW ix). Motor whether squirrel cage or slipring= Squirrel cage/slipring Note:-Squiareel cage upto 65HP and slipring above 65 HP x).Details of shaft extension reqd.= Just sufficient to prode diretc drive by flexible coupling to pump. xi). Type of slip ring gear whether continouly rated or for=Continously rated for squirrel cage/slipng starting purposes only & whether to be fitted with brush lifting or short circuting arrangements or both if interlocks are required. xii). Breakway torque in terms of rated l= Breakway torque to be given by the tenderer but the current which may be taken from the supply with the starting current should not exceed 2.5 of time of the starting apparatus in circuit. full load current, xiii). Nature of load & any information regarding the = to work the pump offered driven machine which has a bearing upon the torque reqd.during the accelearted period, the kinetic energy of the moving parts to be accelarated & No.of starts during a specified period. xiv).. Where possible fault capacity of the system to which the motor is connected.= The motor should be able to withstand intial current of 2.5 times teh rated current for two minutes without suffering damages or permanent deformation.
D) PUMP (BIS 1520-1980)read with BIS 9137-1978 both latest with upto date ammendments a). Nos of pumps reqd.= 2 Nos pumps One working & one as standby. b). Spare parts required= For two years normal maintenance as recommended by manufacturer. c). Optional fittings reqd.= Air cock for exhausting air from each stage.
E) PUMP OPERATING CONDITIONS i). Capacity = 15.44 lps ii). Total head in Mtrs. If total head is not known then following details be provided:- 648.00 i)Static head /Discharde Head = 648.00 Mtr ii)Minimum depth of water= Positive suction iii)Variation in water level=- ---Mtrs iv)Ground level to max.level= --Mtrs v)Ground level to delivery point= Mtrs vi)Pressure in the suction tank= Kg. cm/2 vii)Pressure in the delivery tank=Kg cm/2 iii). Length of R/Main= 3300 Mtr iv). Dia of R/Main= 150mm v). Drive arrangement= Direct through flexible coupling on a comman base plate vi). Drive type= Electric driven. vii0. NPSH reqd.= to be quotated by the tender viii). Limits of total head in which the pump is reqd. to operate.= (-)25% to (+)10% of total head ix). Suction/delivery size of pump= To be specified by the tenderer x). Efficiency of pump at= To be specified by the tenderer a) duty head= b) (+)10% head c) (-)15% head Material of construction= To be specified by the tendered (manufacturers certificate tp ne appended
Material of construction
Programmable Logic Controller for automatic motor and pump control with text HMI,multiple timingoption setting,Seprate 12 vde SMPS UPS backup meeting the protection and control criteria enclosed in technical specification with data logger capable of generating long run report related to current voltage, energy consumption discharge running hours frequency and other pump/ motor characteristics full bore electromagnetic flow meter may be provided for automation i/c all leads an lifts and lifts as per entire satifaction of engineer in charge.
Providing & fixing suitable soft starter of approporiate rating for motor specified in technical specification for the purpose of controlled starting 7 stoping of pump with upper and Lower voltage and current limit i/c all leads an lifts and lifts as per entire satifaction of engineer in charge of standard make such as MEI/Kilburn/Jyoti/ Siemens/Larson & Tubro and other approved make conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling as the case may be with single phase preventor as per IS 1246 (Part-1)-1963 with up to date ammendments.
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.( Each pannel board comprising below mention accessories)
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen / Havells and any other approved make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with up to date ammendment i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
MCCB of appropriate capacity suitable for above specified capacity of Kilburn/LT/LK/MEI/ GEC/ Havells/ Diamond of standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with internal oil filling whenever required and neutral linked under voltage release i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Indicator for main ON-OFF system standby-overload run sump empty -full RYM phase i/c all leads and lifts as per entire satifaction of Engineer-In- Charge
Earth leakage circuit breaker/relay of recommended make such as Kilburn/L&T/MET/GEC conforming to BIS-2516-1977 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side compatible with automation system i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Hour run meter of reputed make of digit capacity conforming to BIS-722 latest edition / recommendation.
Suitable three phase voltage monitor relay with all protections & usual indicators with electric sirens against single phasing, No/low voltage, high voltage & overloading & phase voltage difference as per IS-3842 with up to date ammendments.
Change over Switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable capacity conforming to IS:1248 (P-V)-1983 with up to date ammendments
Float type two point low/high level monitering system of water supply tank(sump well) integrated with programmable logic controller for dry run protection and automatic pump control i/c all leads and lifts as per entire satifaction of engineer
Easy Fault Diagnostics with led disply for main supply missing or <75% phase loss reversal 7 other error, i/c all leads and lifts as per entire satifaction of engineer
Automatic phase reversal rectifeir of appropriate capacity suitable for above specified motor i/c all leads and lifts as per entire satifaction of engineer
Frequency meter for AC Supply of appropriate capacity suitable or above specified motor i/c all leads and lifts as per entire satifaction of engineer
Motor protection circuit breaker for 3 phase/3 wire under voltage/over voltage protection , short circuit protection,overload protection,phase loss,phase reversal protection and motor disconnect function/ i/c all leads an lifts and lifts as per entire satifaction of engineer
Rust free powder coated control panel suitable for housing all the above listed electric and electronic componnents i/c all leads an lifts and lifts as per entire satifaction of engineer
Providing and fixing of Kirloskar/Leader/KSB/fouress/pellicon/ Gled / BHEL and other approved make of cast steel double flanged Automated/ self actuated sluice valve having size one size higher dia than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump (including one No for common header) i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
(NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 600 ASA (seat pressure 105 Kg/cm^2) as per BS 1414 (API 200).
Providing and fixing of Kirloskar/Leader/KSB/pelicon/Fouress and other approved make of suitable size cast iron/cast steel double flanged Automated / self actuated swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 600 ASA (seat pressure 105 Kg/cm^2) as per BS-1414 (API200) .
Providing and fixing of Kirloskar/Leader/KSB/Pelocon/Fouress and other approved make of suitable size cast iron /Cast Steel double flanged Automated / self actuated swing check type reflux valve having bye pass arrangement & size equal to dia of R/main as mentioned in item No.1 (c) for withstanding nominal seat pressure as per Rising main.
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 600 ASA (seat pressure 105 Kg/cm^2) as per BS 1414 (API 200) .
Providing and fixing of Kirloskar/Jyoti/Standard/Kilburn and other approved make cast iron flanged screwed type Automated / self actuated foot valve with strainer of dia equal to dia of suction pipe conforming to BIS 4038-1986 or latest with up to date ammendments.
Providing and fixing of Kirloskar/Leader/KSB/Pelocon/Fouress and other approved make cast iron flanged Automated / self actuatedv Sluice valve for suction pipe having size one or two size larger than suction size of pump such that valocity of flow is not more than 3.00 mtr/sec. with strainer of dia equal three to four times of dia of suction pipe conforming to BIS/API-standards or latest with up to date ammendments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
NOTE:- The C.I sluice valve PN 1.6 as per IS 2906-1998).
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC and other approved make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. i/c all leads an lifts and lifts as per entire satifaction of engineer (for 3 Nos. Pump Set. )
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC and other approved make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge. (for 3 Nos. Pump Set. )
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,copper wiring & 32x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T and other approved make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer) i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Providing and fixing of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump.
NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Providing and fixing of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Errection of all equipments i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Prov and fixing cast steel double flanged Automated / self actuated non returning valves such as Kirloskar, BHEL, Kilburn, KSB,Leader, GLED and other approved make as per BIS 1868 including all leads and lifts complete in all respect.
150 mm dia ASA-600
AUTOMATION AT IInd STAGE AT STATION HALLANA:-
Providing & Fixing Remote automation system consisting of fully wired pannel with PLC system and GPRS commuication with centerlised PLC, interface to the proposed magnatic flow meters and existing pumps. within all leads & lifts as per direction of Engineer- In- Charge.
Providing & Fixing High and Low level switches Float Type for Fresh Water and treated water tanks within all leads & lifts as per direction of Engineer- In- Charge.
Providing & Fixing Treated Water Magnatic Flow Meters for water Transfer from Treated Water tank to Distribution Tanks within all leads & lifts as per direction of Engineer- In- Charge.
Stage- 3
Supply errection, testing and commisioning with automation of horizontal spindle,horizontal split, redial split Single/Multistage centrifugal pumps of standard make such as KSB/Mathar & Platt/Jayoti/Kirloskar and other approved make confirming to BIS 1520-1980 (latest with upto date ammendments) read with BIS 9137-1978 or latest to handle clear water having turbidity up to 50 ppm. with impelleres,casing ring performing funnel & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel/ mild steel to BHEL /Kirlokar/NGEF/Crompton/ Siemen/Jyoti GEC make slip ring/squirrel cage screen protected drip proof induction electric motor suitable for operation on the data given below i/c cost of all accessories in all leads an lifts and lifts as per entire satifaction of Engineer- in- charge.
Stage-3 2 Nos. Pump set ( i.e 1 No. working simultaneously & 1 No. Pump stand by
A) SITE CONDITIONS i) Location of site= At Thua in IPH Sub- Division Nankhari ii) The altitude of place in which the motor is untended to work in ordinary service if it exceeds 1000 Mt= 2288 Mtr. iii) Humidity= Whether generally remains clear during monsoon season. iv) Nature of atmosphere=As normally encountered in Himalyan Range v). Detail of quality of water= Clear cold water. vi) Water free from sand or not= Yes vii). Water corosive or not= Not viii). Turbidity (if any)= Up to 50 PPM ix). NPSH available= Positive suction. x). Any other information or requirement=
B OPERATING CONDITIONS i). Type of current= AC three/ single phase ii). Operating frequency= 50HZ iii). Rated voltage= 400(+/-)10%volts iv). System of earthing if any to to be adopted.= Double loop earthing as per BIS 3043-1987 latest with upto date amemndements v). No. of working hours per day= 16 hours vi). Speed of revolution in RPM= to be quoted by tenderer vii). Direction of rotation= to be quoted by the tenderer viii). The max. Temp. of cooling air & water in the place in which the motor is intented to work in ordinary service.= 25 Degree Centigrade
C) MOTOR i) Ref. to BIS code= BIS 325-1978 read woth 900-1992 (latest) with upto date amendements. ii). Type of enclosure of motor= SPDP (as per BIS 4691-1985 (latest). iii). Type of duty= Continous iv). Mechanical out put in KW= Suitable for driving centifugal pumps re quired for duties specifiation against pumps to avoid overloading of motor a margin of about 15-20% may be kept in the rated out put of prime mover. v). Class of insulation= Class-B vi). Max.permissible temp.rise of motor reqd. if different from given in B(viii) above = ----- vii). Particulars of test reqd. & where they are to be conducted.= As per terms and conditions viii). Particulars as to whether voltage limiting divice will be employed= At S/star delta starter oil immersed fully automatic to be installe between bus bar & motor shunt capacitor is also proposed to be installed for improving the power factor at site. Note:- Star delta starter upto 37.5 KW ATS between 37.5KW to 50 KW & Starter rotor with sluip ring motor beyond 50 KW ix). Motor whether squirrel cage or slipring= Squirrel cage/slipring Note:-Squiareel cage upto 65HP and slipring above 65 HP x).Details of shaft extension reqd.= Just sufficient to prode diretc drive by flexible coupling to pump. xi). Type of slip ring gear whether continouly rated or for=Continously rated for squirrel cage/slipng starting purposes only & whether to be fitted with brush lifting or short circuting arrangements or both if interlocks are required. xii). Breakway torque in terms of rated l= Breakway torque to be given by the tenderer but the current which may be taken from the supply with the starting current should not exceed 2.5 of time of the starting apparatus in circuit. full load current, xiii). Nature of load & any information regarding the = to work the pump offered driven machine which has a bearing upon the torque reqd.during the accelearted period, the kinetic energy of the moving parts to be accelarated & No.of starts during a specified period. xiv).. Where possible fault capacity of the system to which the motor is connected.= The motor should be able to withstand intial current of 2.5 times teh rated current for two minutes without suffering damages or permanent deformation.
D) PUMP (BIS 1520-1980)read with BIS 9137-1978 both latest with upto date ammendments a). Nos of pumps reqd.= 2 Nos pumps One Running and one will act as standby. b). Spare parts required= For two years normal maintenance as recommended by manufacturer. c). Optional fittings reqd.= Air cock for exhausting air from each stage.
E) PUMP OPERATING CONDITIONS i). Capacity = 6.17 lps ii). Total head in Mtrs. If total head is not known then following details be provided:- 592.00 i)Static head /Discharde Head = 592.0 Mtr ii)Minimum depth of water= Positive suction 5.00 Mtrs. iii)Variation in water level=- ---Mtrs iv)Ground level to max.level= --Mtrs v)Ground level to delivery point= Mtrs vi)Pressure in the suction tank= Kg. cm/2 vii)Pressure in the delivery tank=Kg cm/2 iii). Length of R/Main= 3570 Mtr iv). Dia of R/Main= 125mm v). Drive arrangement= Direct through flexible coupling on a comman base plate vi). Drive type= Electric driven. vii0. NPSH reqd.= to be quotated by the tender viii). Limits of total head in which the pump is reqd. to operate.= (-)25% to (+)10% of total head ix). Suction/delivery size of pump= To be specified by the tenderer x). Efficiency of pump at= To be specified by the tenderer a) duty head= b) (+)10% head c) (-)15% head Material of construction= To be specified by the tendered (manufacturers certificate to be appended
Material of construction
Programmable Logic Controller for automatic motor and pump control with text HMI,multiple timingoption setting,Seprate 12 vde SMPS UPS backup meeting the protection and control criteria enclosed in technical specification with data logger capable of generating long run report related to current voltage, energy consumption discharge running hours frequency and other pump/ motor characteristics full bore electromagnetic flow meter may be provided for automation i/c all leads an lifts and lifts as per entire satifaction of engineer in charge.
Providing & fixing suitable soft starter of approporiate rating for motor specified in technical specification for the purpose of controlled starting & stoping of pump with upper and Lower voltage and current limit i/c all leads an lifts and lifts as per entire satifaction of engineer in charge of standard make such as MEI/Kilburn/Jyoti/ Siemens/Larson & Tubro conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling as the case may be with single phase preventor as per IS 1246 (Part-1)-1963 with up to date ammendments.
Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer in charge.( Each pannel board comprising below mention accessories)
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen / Havells make and having capacity 30% extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Busbar chamber having 3 copper bars of suitable rating for full length equal to width of board of 3 live phases and one copper bar of half rating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with up to date ammendment i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
MCCB of appropriate capacity suitable for above specified capacity of Kilburn/LT/LK/MEI/ GEC/ Havells/ Diamond of standard make on in coming feeder for motors offered by the tenderer conforming to BIS 2516-1985 latest with upto date ammendments with internal oil filling whenever required and neutral linked under voltage release i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Indicator for main ON-OFF system standby-overload run sump empty -full RYM phase i/c all leads and lifts as per entire satifaction of Engineer-In- Charge
Earth leakage circuit breaker/relay of recommended make such as Kilburn/L&T/MET/GEC conforming to BIS-2516-1977 with upto date ammendments and of suitaible range which should have control box, oprating handel and trip/reset push button, on/ off indicators, re-indicating off spring condition of the circut breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for tripping of breaker on occurance of earth fault on/ of breaker load side compatible with automation system i/c all leads an lifts and lifts as per entire satifaction of engineer in charge
Hour run meter of reputed make of digit capacity conforming to BIS-722 latest edition / recommendation.
Suitable three phase voltage monitor relay with all protections & usual indicators with electric sirens against single phasing, No/low voltage, high voltage & overloading & phase voltage difference as per IS-3842 with up to date ammendments.
Change over Switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable capacity conforming to IS:1248 (P-V)-1983 with up to date ammendments
Float type two point low/high level monitering system of water supply tank(sump well) integrated with programmable logic controller for dry run protection and automatic pump control i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Easy Fault Diagnostics with led disply for main supply missing or <75% phase loss reversal & other error, i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Automatic phase reversal rectifeir of appropriate capacity suitable for above specified motor i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Frequency meter for AC Supply of appropriate capacity suitable or above specified motor i/c all leads and lifts as per entire satifaction of engineer -in- charge.
Motor protection circuit breaker for 3 phase/3 wire under voltage/over voltage protection , short circuit protection,overload protection,phase loss,phase reversal protection and motor disconnect function/ i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Rust free powder coated control panel suitable for housing all the above listed electric and electronic componnents i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Providing and fixing of Kirloskar/Leader/KSB/fouress/pellicon/ Gled / BHEL make of cast steel double flanged Automated/ self actuated sluice valve having size one size higher dia than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump (including one No for common header) i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
(NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments However, if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 600 ASA (seat pressure 105 Kg/cm^2) as per BS 1414 (API 200).
Providing and fixing of Kirloskar/Leader/KSB/pelicon/Fouress make of suitable size cast iron/cast steel double flanged Automated/ self actuated swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure as mentionmed in item No. 1(a) & conforming to BIS/API-standards with up to date ammendments for delivery line of pump i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 600 ASA (seat pressure 105 Kg/cm^2) as per BS-1414 (API200) .
Providing and fixing of Kirloskar/Leader/KSB/Pelocon/Fouress make of suitable size cast iron /Cast Steel double flanged automated / self actuated swing check type reflux valve having bye pass arrangement & size equal to dia of R/main as mentioned in item No.1 (c) for withstanding nominal seat pressure as per Rising main. i/c all leads an lifts and lifts as per entire satifaction of engineer
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 600 ASA (seat pressure 105 Kg/cm^2) as per BS 1414 (API 200) .
Providing and fixing of Kirloskar/Jyoti/Standard/Kilburn make cast iron flanged screwed type Automated / self actuated foot valve with strainer of dia equal to dia of suction pipe conforming to BIS 4038-1986 or latest with up to date ammendments. i/c all leads an lifts and lifts as per entire satifaction of Engineer-in- Charge
Providing and fixing of Kirloskar/Leader/KSB/Pelocon/Fouress make cast iron flanged Automated / self actuatedv Sluice valve for suction pipe having size one or two size larger than suction size of pump such that valocity of flow is not more than 3.00 mtr/sec. with strainer of dia equal three to four times of dia of suction pipe conforming to BIS/API-standards or latest with up to date ammendments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
NOTE:- The C.I sluice valve PN 1.6 as per IS 2906-1998).
P/L suitable size copper PVC insulated armoured power three & half core cable conforming to BIS 1554 (Part I) -1988 or latest with up to date ammendments of Siemen/Gloster/ ICC/EICO /National /IEC make from meter of HPSEB to circuit breaker & from circuit breaker to bus bar switch & starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles,flexible pipe,solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. i/c all leads an lifts and lifts as per entire satifaction of engineer (for 3 Nos. Pump Set. )
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (part I)-1988 or latest with up to date ammendments of Siemen/ Gloster /ICC/ EICO/National / IEC make from switch to starter & starter to motor (one cable carrying all three phases) including all other electrical equipment /accesories such as thimbles,flexible pipes, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge. (for 3 Nos. Pump Set. )
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt ,GI pipes,thimbles,nuts & bolts,digging of pits,copper wiring & 32x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendments suitable for above motors & other electrical equipments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Supply & errection of floor/wall mounted power factor shunt capacitor conforming to BIS 2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually,of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T//Kilburn/Standard/Siemen/Havells make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer) i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
Providing and fixing of 100mm dia circular dial pressure gauge of suitable range & standard make such as Fiebeg/Bourden/ Precision/PREGA with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 or latest with up to date ammendments i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
P/F double flanged suction, delivery pipe & common header considering site requirements, NPSH required & available & common header having area equal to two times the area of delivery branch of pump including tapers,flanges,rubber gaskets 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. away from the outer wall of pump house as per layout drawings approved by Engineer-in-Charge. The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. 1 (E)-(ii). The size of suction pipe shall be one or two sizes larger than the suction size of pump such that valocity of flow in suction pipe is not more than 3.00 mtr/sec & delivery pipe shall be of size one size larger than nominal delivery size of pump i/c all leads an lifts and lifts as per entire satifaction of engineer -in- charge.
NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Providing and fixing of antivibration pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Errection of all equipments i/c cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Prov and fixing cast steel double flanged Automated / self actuated non returning valves of approved make makes such as Kirloskar, BHEL, Kilburn, KSB,Leader, GLED as per BIS 1868 including all leads and lifts complete in all respect.
125 mm dia ASA-600
AUTOMATION AT IIIrd STAGE AT UPPER THUA & VARIOUS DISTRIBUTION SYSTEM :-
Providing & Fixing Remote automation system consisting of fully wired pannel with PLC system and GPRS commuication with centerlised PLC, interface to the proposed magnatic flow meters and existing pumps. within all leads & lifts as per direction of Engineer- In- Charge.
Providing & Fixing High and Low level switches Float Type for Fresh Water and treated water tanks within all leads & lifts as per direction of Engineer- In- Charge.
Providing & Fixing Treated water Flow Control Motorised Valve for Water Transfer from Treated Water Tank to Downstream i.e Distribution system within all leads & lifts as per direction of Engineer- In- Charge.
Oasis Enterprises
Unipro Techno Infrastructure Pvt Ltd
HYDRAULIC ENGINEERING COMPANY
competent associates
Gaurav Thakur
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .