Superintending Engineer
Office of the Superintending Engineer, MICC, EKM
LI scheme
2020_Irrig_388567_2
11/ET/SEMICC/2020-21/S
Open Tender
Civil Works - Lift Irrigation Schemes
Item Rate
545 days
Parakkadavu Grama Panchayath
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
Yes
₹50,000
Yes
28 Nov 2022
8 Jan 2021
27 Jan 2021
9 Jan 2021
25 Jan 2021
11 Jan 2021
9 Jan 2021 - 18 Jan 2021
60 days
Amount
Appendix A construction of Pump house
Appendix A ; Construction of Pump house 2.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared as per the direction of departmental officers at site.
15.7.4 : Demolishing brick work in cement mortar manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge for parapet, wall etc
15.9.2 : Demolishing stone rubble masonry In cement mortar manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges of steps.
15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter Of area 3 sq. metres and below including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead: as per direction of Engineer -in- Charges.
2.8.1 : Earth work in excavation in all kinds of soil by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m as per direction of Engineer -in- Charges for coulummn, footings etc.
4.1.8 : Providing and laying in position cement concrete of specified grade 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) excluding the cost of centering and shuttering - All work up to plinth level as per direction of Engineer -in- Charge for column, footings and flooring.
4.1.3 : Providing and laying in position cement concrete of specified grade :1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) excluding the cost of centering and shuttering - All work up to plinth level as per direction of Engineer -in- Charge for flooring of pump house.
5.1.3 : Providing and laying in position specified grade of reinforced cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone , excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:aggregate 20 mm nominal size) as per direction of Engineer -in- Charge for fixing hold fast.
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete 1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size , excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: as per direction of Engineer -in- Charge for column, footings, coulmn up to plinth level etc.
5.2.2 : Reinforced cement concrete :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) work in walls (any thickness), up to floor five level excluding cost of centering, shuttering, finishing and reinforcement as per direction of Engineer -in- Charge for column up to first floor , upto roof level etc.
5.3 : Reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, as per direction of Engineer -in- Charge for plinth beam, lintel beams, sunshades, roof slabs etc
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete as per direction of Engineer -in- Charge
5.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform as per direction of Engineer -in- Charge for backside of sunshade roof slab etc.
5.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers as per direction of Engineer -in- Charge
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Strutsas as per direction of Engineer -in- Charge for coulmns up to ground floor slab and above ground floor slab.
5.22.1 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars as per direction of Engineer -in- Charge
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete as per direction of Engineer -in- Charge for walls, parapet etc.
50.13.1 : 9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete as per direction of Engineer -in- Charge for roof slab, deck slab, sunshade etc.
50.9.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood as per direction of Engineer -in- Charge.
14.29 : Providing and fixing M.S. round or squre bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows as per direction of Engineer -in- Charge
50.9.4.1 : Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood as per direction of Engineer -in- Charge for doors.
50.9.6.1 : Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Using Anjili wood / jack wood 30 mm thick shutters as per direction of Engineer -in- Charge for windows.
9.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm as per direction of Engineer -in- Charge for doors.
9.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per direction of Engineer -in- Charge for doors and windows.
50.9.15.1 : Supplying and fixing 200 mm Aluminium aldrop as per direction of Engineer -in- Charge for doors.
50.9.15.5 : Providing and fixing iron hooks and eyes: 100 mm as per direction of Engineer -in- Charge for windows.
9.76 : Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete as per direction of Engineer -in- Charge for doors.
50.18.9.19.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall as per direction of Engineer -in- Charge for soil pipe.
13.85.1 : Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content with ready mixed pink or grey primer on wood work (hard and soft wood ) having VOC content less than 50 grams/ litre as per direction of Engineer -in- Charge for doors and windows.
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work for doors and windows as per direction of Engineer -in- Charge.
13.71 : Lettering with black Japan paint of approved brand and manufacture as per direction of Engineer -in- Charge.
13.85.3 : Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre as per direction of Engineer -in- Charge for columns.
10.1 : Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as per direction of Engineer -in- Charge for I section.
Appendix : B- Laying of pipe.
Appendix : B- Laying of pipe. 15.43.2 : Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
18.31.4.2 : Providing and fixing C.I. sluice valves 200 mm diameterClass II (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately) as per direction of Engineer -in-Charge.
60.9 : MS Pipes 300mm - Manufacturing supplying and fitting 300mm dia MS pipe of various length with shell thickness 6mm including painting with 2 coats of red oxide primer, laying the same to line and level as directed by departmental officers at site for suction and delivery line.
60.10 : MS Flanges for 300mm pipe - Manufacturing supplying and fitting 300mm dia MS Flange having shell thickness 10mm depth 75mm with suitable bolt ,holes,fixing the flange in position with required welding around the flange,pipe joint grinding for smoothing the welded portion,including painting with red oxide primer etc. complete as directed by departments officers.
od28815/2020_2021/IA : Supply, fabrication, conveyance,and fixing 300mm size MS pipe bend, fabricated from 300mm MS pipe having 6mm sheet thickness with length not less than 1 meter , painting two coats of ready mixed red oxide zinc chromate primer of approved brand as per direction of Engineer -in-Charge.
od28816/2020_2021/IA : supply, fabrication, conveyance and fixing 300 X 200mm or nearest size 0.3 meter long MS reducer fabricated from 300mm MS pipe having 6mm sheet thickness painting with two coats of synthetic enamel paint over a coat of red oxide primer as per direction of Engineer -in-Charge.
od26994/2019_2020/IA : Supplying and conveying 200 mm dia PVC pipes (10 kg/ cm2) Laying and jointing to lines and levels in trenches up to a depth 1.50 meters including earth work excuvation in all classes of soil (except hard rock which requires blasting )fencing sides of trenches, keeping danger lights during night, bailing out water from trenches if necessary, lowering the pipes carefully in trenches and laying in position and joining with solvent cement with necessary specials such as bend, tees, elbows and reducers etc as per site condition, refilling the trenches and consolidating in layers, watering, ramming, testing to specified pressure after completion of work , including all labor charges and all other incidental charges etc compete as per standard specification and as directed by the departmental officers at site.
od22580/2020_2021/IA : :Supply , conveyance and errection of 200 mm heavy duty Cast Iron Flanged N R V(Reflex Valve ) with Gun Metal Seat & Flap as required including fitting charges as per direction of Engineer -in-Charge for pump house.
2.10.1.2 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia as per direction of Engineer -in-Charge for laying pipe in main and branch.
od22201/2020_2021/IA : Fencing one side of trenches, 1.50 m height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2 m intervals (KW 8.1) for main and branch as per direction of Engineer -in-Charge.
od28808/2020_2021/IA : Supplying and fixing 200 mm dia end cap (PVC) including fitting charges, solvent cement etc complete as per the directions of departmental officers at site.
od28809/2020_2021/IA : Supplying and fixing 200mmx150mm dia reducer (PVC) including fitting charges, labor etc complete as per the directions of departmental officers at site.
od28810/2020_2021/IA : Providing and fixing 200 mm dia tail piece (PVC) including fitting charges, solvent cement etc complete as per the directions of departmental officers at site
od28811/2020_2021/IA : supplying and fixing 200 mm dia bend (PVC) including fitting charges, solvent cement etc complete as per the directions of departmental officers at site.
od28812/2020_2021/IA : Supplying and fixing 200 mm dia tee (PVC) including fitting charges, solvent cement etc complete as per the directions of departmental officers at site.
od22198/2020_2021/IA : Supplying and laying 150mm dia PVC pipes (6kg/cm2)and specials, solvent cement from the stacking places of work site, lowering in to trenches already made, placing in position aligning the pipe to lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure including hire charges for all tools testing equipments cost and conveyance of water etc complete as per direction of Engineer -in-Charge.
od22206/2020_2021/IA : MS pipes 200mm - Manufacturing supplying and fitting 200mm dia MS pipe of various length with shell thickness 6mm including painting with two coats of red oxide primer, laying the same to lines and levels ad directed by the departmental officers at site.
od22215/2020_2021/IA : Providing and fixing 150 mm dia tail piece (PVC) including fitting charges, solving cement etc complete as per direction of Engineer -in-Charge.
od22338/2020_2021/IA : supplying and fixing 150 mm dia PVC bend including fitting charges, solvent cement etc complete as per direction of Engineer -in-Charge.
od22339/2020_2021/IA : Supplying and fixing 150 mm dia tee (PVC) including fitting charges, solvent cement etc complete as per the directions of departmental officers at site.
od28826/2020_2021/IA : Supplying and fixing 150 mm dia end cap (PVC), including fitting charges, solvent cement etc complete as per the directions of departmental officers at site.
od22216/2020_2021/IA : Providing and fixing 25mm dia double acting air valve including all accessories etc complete as per CPWD specifications and direction of Engineers in charge at site.
od22217/2020_2021/IA : MS flanges for 150 mm dia pipe - manufacturing supplying and fitting 150 mm dia MS flange having shell thickness 10 mm depth 75 mm with sutable bolt holes fixing the flanges in position with required welding around the flange, pipe joint grinding for smoothing the welded portion,including painting with red oxide primer etc. complete as directed by deptl. officers at site .
18.31.3.1 : Providing and fixing C.I. sluice valves 150 mm diameterClass I (with cap) complete with bolts, nuts, rubber insertion etc. (the tail pieces if required will be paid separately) as directed by deptl. officers at site .
od22319/2020_2021/IA : Making connection of PVC distribution 150mm dia branch with PVCmain 200mm dia by providing and fixing MS saddle including cutting and treading the pipe etc.complete as directed by deptl. officers at site .
2.8.1 : Earth work in excavationin all kinds of soil by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m as directed by deptl. officers at site .
4.1.8 : Providing and laying in position cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) of specified grade excluding the cost of centering and shuttering - All work up to plinth level as directed by deptl. officers at site .
4.1.3 : Providing and laying in position cement concrete 1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of specified grade excluding the cost of centering and shuttering - All work up to plinth level: as directed by deptl. officers at site .
13.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) as directed by deptl. officers at site of the chamber
5.22.6 : Steel reinforcement Thermo - Mechanically Treated bars of grade Fe-500D or more for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level as directed by deptl. officers at site
Bidder Name
AVANCE ENGINEERING AND INFRASTURCTURES PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_575974.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .