Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAdmitted-Finance THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | L1 | Admitted-Finance | |
| 2 | L2₹7.2 L+₹71,865 (11.1%)Admitted-Finance D S ELECTRICALS D S MANDIRAM SREEVARAHAM VALLAKADAVU P O TRIVANDRUM | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | D SURESH L2 | DIVIN SAM D S L1 |
|---|---|---|---|---|---|
| 1.00Urgent Replacement | |||||
| 1.00 | OD181694/2026-2027:Dismantling and safely removing old, damaged streeighs Mounted on Existing poles etc; Engaged Wireman | 5 | Day | 1,215 ₹6,075 | 1,000 ₹5,000 Lowest |
| 1.00 | OD181693/2026-2027:Dismantling and safely removing old, damaged streetlights Mounted on Existing poles etc; Engaged Khalasi | 10 | Day | 1,000 ₹10,000 | 900 ₹9,000 Lowest |
| 1.00 | 90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 65 | each | 10,100 ₹6,56,500 | 9,000 ₹5,85,000 Lowest |
| 1.00 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm | 420 | metre | 83 ₹34,860 Lowest | 86 ₹36,120 |
| 1.00 | 2.10.5:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Triple pole and neutral | 10 | each | 1,400 ₹14,000 Lowest | 1,445 ₹14,450 |
Tender Value
₹7.5 L
EMD Value
₹18,800
Closing Date
10 Nov 2026, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER, ELECTRICAL DIVISION
EXECUTIVE ENGINEER OFFICE, ELECTRICAL DIVISION, TRAVANCORE DEVASWOM BOARD, CHENGANNUR
Nilackal Devaswom in Sabarimala Urgent Replacements of damaged Street Light in and around the Nilackal Base Camp-M M festival 2026 27 RETENDER
2026_TDB_883931_2
TDB/EEE/ET-130/2026-27
Open Tender
Electrical Works
Item Rate
10 days
Nilackal
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,953
₹18,800
10 Nov 2026
6 Nov 2026
10 Nov 2026
6 Nov 2026
10 Nov 2026
6 Nov 2026
270 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Urgent Replacement | |||||
| 1.001 | OD181694/2026-2027:Dismantling and safely removing old, damaged streeighs Mounted on Existing poles etc; Engaged Wireman | 5 | Day | - | - |
| 1.002 | OD181693/2026-2027:Dismantling and safely removing old, damaged streetlights Mounted on Existing poles etc; Engaged Khalasi | 10 | Day | - | - |
| 1.003 | 90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 65 | each | - | - |
| 1.004 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm | 420 | metre | - | - |
| 1.005 | 2.10.5:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Triple pole and neutral | 10 | each | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.07 MB
sbd130.pdf
Tender Documents • 0.34 MB
documentformat130.pdf
Tender Documents • 0.07 MB
APPROVEDMATERIALLIST.pdf
Tender Documents • 0.51 MB
BOQ_1512355.xls
BOQ • 0.30 MB
SPECIALCONDITIONSetender.pdf
Tender Documents • 0.08 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .