Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹14.6 LAccepted-AOC 110B CIVIL LINES BAREILLY 243001 UP | BAREILLY | UTTAR PRADESH | 243001 | L-1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L-2₹17.1 L+₹22,140 (1.31%)Rejected-Finance | L-2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L-3₹17.3 L+₹38,080 (2.25%)Rejected-Finance C O MODERN FURNITURE B I BAZAR BAREILLY CANTT BAREILLY 243001 UP | BAREILLY | BAREILLY | UP | 243001 | L-3 | Rejected-Finance Over all rates are higher than L-1. | |
| 4 | L-4₹18.1 L+₹1.2 L (7.33%)Rejected-Finance | L-4 | Rejected-Finance Over all rates are higher than L-1. | |
| 5 | L-5₹21.8 L+₹4.9 L (29.2%)Rejected-Finance | L-5 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
24 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST BAREILLY
GE WEST BAREILLY, 243001
REPAIR / REPLACEMENT OF SECURITY LIGHTS, ALLIED WORKS INCLUDING DAILY MAINTENANCE OF SECURITY LIGHTS AT WEST AREA UNDER GE (WEST) BAREILLY.
2023_MES_599391_1
8122/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE WEST BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE WEST BAREILLY
₹76,000
Yes
16 Aug 2023
29 May 2023
26 Jun 2023
29 May 2023
24 Jun 2023
12 Jun 2023
Amount
Dismantling of Street light, Security light, Flood light, tube light fitting any type and capacity from existing pole, building at any height and re-fixing the same after repair, replacment of unserviceable parts such as tube lamp, lamp, ballast, ignitor, holder, starter, bipin holder etc. and making the light fitting functional by replacing minor parts such as nut-bolts, PVC connector etc. as required at site complete all as specified and directed. NOTE- Spares shall be measured and paid separately in respective items of this schedule. Contractor shall provide sufficient Electricians and helpers as per daily requirement subject to minimum 1 Electrician and 1 helper to carry out the repair / Maint work of security lights in day shift (900 Hours-1700 Hours) and they have to report AGE E/M yard for daily assingment / task. Contractor shall provide all necessary tools & plants, minor spares such as Ladder, nut-bolts, jumper wire, insulation tape etc. which are required for doing the job related with electric supply including mobile phone facility to all workmen and will be fully responsible for safety and security of their workmen. In case non reporting of required staff in AGE E/M yard, recovery shall be made @ Rs. 500.00 per day from the contractor.
Supply only following spare parts of LED street light fitting complete all as specified and directed: - NOTE- Fixing charges are included in the unit rate of item No. 1.00 of this schedule.
(a) Integral LED street light driver, enclosed with glass cover frame suitable for 30 to 50 watt capacity LED light fitting.
(b) Integral LED street light driver, enclosed with glass cover frame suitable for 60 to 72 watt capacity LED light fitting.
(c) Integral LED street light driver, enclosed with glass cover frame suitable for 90 watt and above capacity LED light fitting.
(d) Integral LED street light module with complete PCB and LED suitable for 30 to 50 watt capacity LED street light fitting.
(f) Integral LED street light module with complete PCB and LED suitable for 60 to 72 watt capacity LED street light fitting.
(f) Integral LED street light module with complete PCB and LED suitable for 90 watt and above capacity LED street light fitting.
S & F in replacement 2.50 Sqmm size two core PVC insulated and unsheathed multistranded aluminium conductor cable complete all as specified and directed.
S & F in replacement MCBs TPN 63 Ampere,415 volts, 16 KA complete all as specified and directed.
S & F in replacement MCBs SPN 32 to 40 Ampere, 220 volts, 10 KA complete all as specified and directed.
S & F in replacement MCBs SPN 6 to 32 Ampere, 220 volts, 10 KA complete all as specified and directed.
S & F as in replacement LED street light fitting with powder coated pressure die cast aluminium compact heat resistance toughened glass with lens and surface mounting diode (SMD) LED as light source and electronic driver, having IP-65/66 protection and making electric connection with 2.5 sqmm aluminum wire complete all as specified and directed for the following capacities: -
(a) 35/36 Watt capacity.
(b) 60 Watt capacity.
(c) 70/72 Watt capacity.
(d) 90 Watt capacity.
S & F as in replacement LED flood light 230 volts, AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection, with impact and corrosion resistant complete with driver and lamp surface mounting diode (SMD) complete all as specified and directed for the following capacities: -
(a) 50/60 Watt capacity.
(b) 100 Watt capacity.
(c) 120 Watt capacity.
(c) 170 Watt capacity.
S & F in replacement loop-in-loop out box of size 30 x 20 x 20 cm made out from 1.6 mm thick PVC sheet weather proof, dust and vermin proof with hinged door and locking arrangements with slanting cover on top and provision of 4 Nos. aluminium bus bar of size 25 mm x 2 mm duly fixed on insulator and one MCB of capacity 6 Ampere, fixed on pole with and including suitable size mild steel flat iron clamps, nut-bolts and washers etc. complete all as specified and directed.
S & F as in replacement street light bracket made out of GI pipe light grade 40 mm dia of length upto 1.20 metre, bent to shape required with and including 2 Nos. 50 x 6 mm mild steel flat iron clamps with suitable nut-bolts, washers etc and applying one coat of aluminium paint to clamps complete all as specified and directed.
Supply, fixing, commisioning and testing of Nature timer switch control Street Lights alongwith MCBs, Power and Panel duly pre-wired as per Model-SWADEEP-02EC 05KW1P, single phase, maximum load 5 KW complete all as specified and directed. MAKE- Swadeep, Indo Asian, Chime Electronics Delhi (Brand - Sinetrac) NOTE- CA No. and date of installation shall be painted / marked on all timer switches by the contractor at the time of installation.
Supply, fixing, commisioning and testing of Nature timer switch control Street Lights alongwith MCBs, Power and Panel duly pre-wired as per Model-SWADEEP-02EC 12KW3P, three phase, maximum load 12 KW complete all as specified and directed. MAKE- Swadeep, Indo Asian, Chime Electronics Delhi (Brand - Sinetrac) NOTE- CA No. and date of installation shall be painted / marked on all timer switches by the contractor at the time of installation.
S & F as in replacement 4 Sqmm twin core 1100 Volts grade heavy duty flat or circular PVC insulated aluminium stranded conductor cable served with inner sheathing of PVC tape and overall PVC sheathed as in service connection from electric pole to Main Switch complete all as specified and directed.
S & F as in replacement 6 Sqmm twin core 1100 Volts grade heavy duty flat or circular PVC insulated aluminium stranded conductor cable served with inner sheathing of PVC tape and overall PVC sheathed as in service connection from electric pole to Main Switch complete all as specified and directed.
S & F as in replacement 10 Sqmm twin core 1100 Volts grade heavy duty flat or circular PVC insulated aluminium stranded conductor cable served with inner sheathing of PVC tape and overall PVC sheathed as in service connection from electric pole to Main Switch complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for laying cables and getting out in soft / loose soil including trimming sides and forming bottom surface to the required level / slope etc complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in each layer as in soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
M & L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after laying of cable in trenches, punning complete all as specified and directed. NOTE- Punned thickness of 18 cm shall be considered for measurement and payment.
M & L for laying brick as in protection covers over cables using sub class 'B' old size bricks laid flat, length wise perpendicular to the axis of cable complete all as specified and directed.
Laying only old serviceable bricks obtained from taking out old cables complete all as specified and directed.
S & F in repairs 40 mm bore GI pipe light grade for cable protection, fixed to pole, along wall, under floor, under road, across the drain or nallah and the like complete all as specified and directed.
S & F in repairs 50 mm bore GI pipe light grade for cable protection, fixed to pole, along wall, under floor, under road, across the drain or nallah and the like complete all as specified and directed.
Supply, laying, jointing and testing of 1100 volts grade LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor laid in trenches / ducts, fixed to wall / inside panel, drawn through pipe with and including taking up old unserviceable one complete all as specified and directed for the following sizes: -
(a) 25 Sqmm 4 core.
(b) 16 Sqmm 4 core.
(c) 10 Sqmm 4 core.
(d) 10 Sqmm 2 core.
Dismantling of electrical connections including timer and old unserviceable lights of High Mast light from pole including all asseccories and repairing of internal wiring, cable of high mast light, up-down mechanism of high mast light mounting system, replacemnt of unserviceable lights and repair of Timer switches complete all as specified and directed. NOTE- Lights as required will be measured and paid separately under respective items of this schedule.
M & L for repairing to Nature timer switch control system of Street Lights including repair of power control Panel, replecement of contactor switches, relay and timer switch, MCBs and any other minor accesories as required at site for three / single phase timer complete all as specified and directed. NOTE- Contactor switch relay and timer controller as required will be measured and paid separately under respective items of this schedule.
S & F of contactor switch relay as per existing model and capacity suitable for existing nature timer switch of street lights complete all as specified and directed.
S & F of PVC MCB Enclosure box suitable for DP and SP MCB complete all as specified and directed.
Lopping / prooning of tree branches upto the extend to obtain clearance all around the LT over head lines conductor upto 3 meters from furthest conductor on pole including removing of cut branches and cleaning of site complete all as specified and directed. NOTE- The tree branches etc. will be left as it is on ground and will not be carried away by the contractor / DEL as the same belongs to CEO / DEO and they will be responsible to lift the same from site. Prooning of all branches in one tree shall be measured as one Job. Contractor shall employ sufficient labour to complete the job with in time as directed. Contractor shall be held responsible for any type of mis-happening, accident while prooning the trees. Tools & plants including safety measure equipments like belt, ladder, ropes etc. shall be arranged by the contractor at his own cost. Contractor or his representative will take proper shut down before starting the work and clear it before resuming power supply.
Opening the binding wire from pin / shackle insulator on steel pole of any height for re-stretching the ACSR conductor, after re-stretching without kinks & bends, binding the pin / shackle insulator with appropriate size of aluminium binding wire complete all specified and directed. NOTE- Cost of binding wire deemed to be included in the quoted rate, No extra amount will be paid. One RM length will be measured for 03 phase and one neutral one street light and one earth wire.
Dismantling of LT PCC, steel tubular pole including demolition of pole coping, foundation etc. complete all as specified and directed.
Supply and erection, in truly vertical position, LT Steel tublar swaged pole complete with cast iron base plate, finial taper plug, bolt , nut and screwed type 410-SP-31 (9 meters long ) Class -10 including painting of poles with two coats of synthatic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles as directed. NOTE- PCC, Earth work and MS work as cross arms clamps etc. shall be measured and paid separately.
M & L for PCC 1:4:8 type D-C2 (using 40 mm graded aggregate) in foundation, filling and mass concrete complete all as specified and directed.
M & L for PCC type C-2, 1:3:6 (using 20 mm graded aggregate) as in coping to the poles with and including necessary form work as required complete all as specified and directed.
M & L fabrication of mild steel busbar chamber of nominal dimension 900 mm x 600 mm x 400 mm duly provided with aluminimum busbar of size 50 mm x 6 mm fixed on porcelain insulators TPN type, out door, weather proof, vermin proof, with both way opening duly provided with neoprene rubber gasket along the doors openings, pedestal type, duly painted, powder coated CRCA steel sheet enclosere with one No. incommer MCCB 250 Ampere 35 KA and making all electric connections including thimbles as required complete all as sepcified and directed.
All as per item No. 35.00 hereinbefore but bus bar chamber of size 600 mm x 600 mm x 300 mm, bus bar rating 400 Ampere and without MCCB complete all as specified and directed.
M & L for cleaning and preparation of old painted surface of LT steel tubular pole and painting with one coat of aluminium paint including channels, brackets, street light brackets, cross arms and making Black, Red, Yellow and white strips as directed of 30 cm high with synthetic enamelled paint, each alternative strip upto 1.5 metre height of pole and writing pole number with yellow synthetic enamel paint after making circular base with black synthetic enamel paint and applying two coat of white wash on exposed PCC coping complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground vertically (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to galvanised earth lead 4 mm dia with necessary nut-bolts, check nuts, washers etc., all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including ......
...... all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 75 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel TMT bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:2:4 type B-1, GI protection pipe light grade 15 mm bore including testing on completion of job complete all as specified and directed.
NOTES- (i) Day to Day Complaints pertaining to Street Light shall be resolved by the contractor within 24 hrs of getting complaints. In case of failure on the part of contractor to resolve to the complaints within stipulated time, a penalty of Rs. 500.00 per complaint per day shall be imposed from the contractor. (ii) The contractor or his authorised representative shall report to the concerned JE E/M at 0900 hours daily on all working days to receive order, instructions of the work. A register shall be maintained to record all orders, instructions and their complaints and is to be signed by the contractor / his representative and the Engineer-in-charge / JE E/M concerned. (iii) Work done register to be maintained by the contrator. A separate Docket complaints slip book shall maintained by the contractor to note the complaints, jobs and get it signed by the user after completion of work and submits to the JE-in-Charge. (iv) Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.
sunder and company
D K THUKRAL AND SONS
LEEJA ENTERPRISES
NOORI ENTERPRISSES
N S ELECTRICALS
Shri Siddhi Vinayak Constructions
VINYAK TRADERS
Ishtiaq and Sons
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .