| 1 | l-1₹14.3 LAccepted-AOC | l-1 | Accepted-AOC Tender accepted due to lowest and quoted reasonable rates | |
| 2 | l-2₹14.6 L+₹34,743 (2.43%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | l-2 | Rejected-Finance Higher side quoted amount | |
| 3 | l-3₹16.4 L+₹2.1 L (14.6%)Rejected-Finance R O 218 05 OPP J D A COMPLEX TRIKUTA NAGAR JAMMU J K PIN 180020 | JAMMU | JAMMU AND KASHMIR | 180020 | l-3 | Rejected-Finance Higher side quoted amount | |
| 4 | l-4₹21.9 L+₹7.6 L (53.2%)Rejected-Finance AWANTA BHAWAN SOURA SRINAGAR 190011 J K | SRINAGAR | JAMMU AND KASHMIR | 190011 | l-4 | Rejected-Finance Higher side quoted amount | |
| 5 | Rejected-Technical SAIDAKADAL SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | - | Rejected-Technical Due to not enlisted in appropriate category. |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
4 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Khumbathang
CWE Khumbathang
REPAIR/ MAINT OF HT UG/OH ELECTRIC LINE AND CONNECTED ITEMS OF VARIOUS UNIT AT KARGIL, KAKSAR, HINSKUT, BUDHKHARBU, APATI, CHHANIGUND AND HARDAS UNDER GE KARGIL
2023_MES_585123_1
80051/149/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Kargil
As per tender and NIT doc
8 documents required · 8 mandatory
₹500
GE Kargil
₹50,000
3 May 2023
10 Mar 2023
5 Apr 2023
10 Mar 2023
4 Apr 2023
22 Mar 2023
Amount
Supply and fix in repair change over switch 100 Amps, 415 Volts, 4 pole on load with side handle .complete all as specified and directed by Engr-in-Charge.
All as per item no. 1.00 here-in-before but 200 Amps, 415 Volts, 4 pole complete all as specified and directed by Engr-in-Charge.
All as per item no. 1.00 here-in-before but 320 Amps, 415 Volts, 4 pole complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair for MCCB 250 Amps,415 volts,25 ka,microprocessor released based 4 pole 415 Volts, 25 KA breaking capacity complete all as specified and directed by the Engr-in-Charge.
All as per item no. 4.00 here-in-before but 200 Amps, 415 Volts, 25 KA complete all as specified and directed by Engr-in-Charge.
All as per item no. 4.00 here-in-before but 125 Amps, 415 Volts, 25 KA complete all as specified and directed by Engr-in-Charge.
All as per item no. 4.00 here-in-before but 100 Amps, 415 Volts, 25 KA complete all as specified and directed by Engr-in-Charge.
S&F in replacement of lightening arrester for outdoor use, non liner resister type,horn gap and choking coil, maximum working pressure 11000 Volts, discharge capacity 65 kilo amp complete all as specified and directed by the Engr-in-Charge
Straining and re-stretching of existing over head aluminium conductor steel reinforced (ACSR) of any size on HT poles including binding and jointing the conductor with and including 14 SWG binding wire and jumpers connections with PG clamps complete all as specified and directed by Engr-in-Charge.
Straining and re-stretching of existing over head aluminium conductor steel reinforced (ACSR) of any size on LT poles including binding and jointing the conductor with and including 14 SWG binding wire and jumpers connections with PG clamps complete all as specified and directed by Engr-in-Charge.
Dismantling of ACSR conductor any type any size complete all as specified and directed by Engr-in-Charge.
S&F ACSR conductor of (weasel) 6/1/2.59 for LT line (0.433 KV), straching properly on insulators and binding with aluminium binding wires,jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between span etc complete all as specified and as directed by Engineer-in-charge.
S&F ACSR conductor or service feeder distribution span and S&F ACSR conductor of (Rabbit) 6/1/3.35 for HT line (11 kv), straching properly on insulators and binding with aluminium binding wires,jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between span etc complete all as specified and as directed by Engineer-in-charge.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m complete all as specified and as directed by Engr-in-Charge.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed by Engr-in-Charge.
Dismantling of Stay assembly complete all as specified and as directed by Engr-in-Charge.
S&F Stay assembly complete with GI stay rod 20 mm dia 1800 mm long, MS plate 230x2306 mm, stay bow,loop insulator, PCC 1:3:6, connecting bracket of suitable MS flat and nut bolt washers etc complete all as specified in electrical plate No 1 of SSR Part-1 including taking out old stay assembly complete all as specified and as directed by Engr-in-Charge. (Note:- Excavation and PCC measured and paid separately)
Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc. or carrying to MES store complete all as specified and directed by Engr-in-Charge.
S&F gang operated air break switches 12 insulators mounted on MS Channel with operating mechanism worked from ground level suitable for 11000 volts, 400 Amps including GI pipe handle clamps bolts, nuts, jumper wire connecting with stranded conductors complete with locking arrangements complete all as specified and directed by Engr-in-Charge.
Excavation in trenches hard/ dense soil, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, not exceeding 10 sqm on plan and not exceeding 1.5Mtr in depth & getting out of hard and danse soil for taking out pipe & laying of pipe & getting out for diverting of CI pipe line complete all as specified and directed by Engr-in-Charge.
Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering of Hard/ dense soil and well ramming in layers not exc 25 cm. complete all as specified and directed by Engr-in-Charge.
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I complete all as specified and as directed by Engr-in-Charge. (Note:- Punned thickness will be measured and Paid)
Supplying and laying reinforced precast concrete cable cover in repair, class HV, Type I, flat, size 300 mm x 180mm x 40mm laid dry over electric cable for protection,complete all as specified and directed by the Engr-in-Charge.
Demolition of Plain cement concrete for pole complete all as specified and directed by Engr-in-Charge.
M&L for Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete,complete all as specified and directed by the Engr-in-Charge.
M&L for Plain cement concrete 1:3:6 type C-1 (using 20mm grade aggregate) as in coping including all necessary form works complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engr-in-Charge.
Taking out of XLPE cable of any type any size from trenches/pole including PCC precast cable cover complete all as specified and directed by Engr-in-charge.
Supply, laying and testing, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 95 sq. mm 3 core complete all as specified and directed by Engr-in-charge.
Supply, laying and testing, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 240 sq. mm 3.5 core complete all as specified and directed by Engr-in-charge.
All as per item no. 31.00 here-in-before but 185 Sqmm, 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per item no. 31.00 here-in-before but 95 Sqmm, 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per item no. 31.00 here-in-before but 70 Sqmm, 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per item no. 31.00 here-in-before but 50 Sqmm, 3.5 core complete all as specified and directed by Engr-in-Charge.
All as per item no. 31.00 here-in-before but 25 Sqmm, 4 core complete all as specified and directed by Engr-in-Charge.
All as per item no. 31.00 here-in-before but 16 Sqmm, 4 core complete all as specified and directed by Engr-in-Charge.
Supply and laying or fixing or passing in replacement through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sqmm, 2 core nominal cross section in service connections complete all as specified and as directed by Engr-in-Charge.
All as per item no. 38.00 here-in-before but 16 Sqmm, 2 core complete all as specified and directed by Engr-in-Charge.
Supply fixing Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6.3 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI strip size 32X6mm as earthling lead by means blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel, wire gauge. CI cover with frame , 15 MM dia GI pipe light grade for protection of wire etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 5 of MES Sch Part I , connected to Earthing test point on completion complete all as specified and directed by Engr-in-Charge.
S&F in repair LT spacer 4 ways made out of PVC material complete all as specified and directed by Engr-in-Charge.
Dismantling of steel tubular swaged poles of any length complete with cast iron base platecomplete all as specified and directed by Engr-in-Charge.
Supplying, transporting, erecting and fixing steel tubular swaged poles type 410 SP-55 (11.00 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws including necessary excavation and earth work, PCC 1:4:8 type D-2 in foundations below pole, PCC 1:3:6 type C-2 around poles and PCC 1:3:6 type C-1 as in plinth block, disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surfaces with aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/straps with synthetic enamel paint and 2 bands with black bituminous paint) from plinth block and numbering of poles, painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed by Engr-in-Charge. Note:-PCC work will be measured and paid separately.
Supplying, transporting, erecting and fixing steel tubular swaged poles type 410 SP-31 (9.00 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws including necessary excavation and earth work, PCC 1:4:8 type D-2 in foundations below pole, PCC 1:3:6 type C-2 around poles and PCC 1:3:6 type C-1 as in plinth block, disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surfaces with aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/straps with synthetic enamel paint and 2 bands with black bituminous paint) from plinth block and numbering of poles, painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed by Engr-in-Charge. Note:-PCC work will be measured and paid separately.
M&L in replacement of pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 11000 volts grade complete all as specified and directed by Engr-in-Charge.
Cleaning the extend exposed surfaces of steel tubular pole of 9 Mtr long including with cross arms, brackets clamps etc and painting complete ( Except embedded portion) including all MS work mounted on pole, earth potection & water pipe (if exists) with two coat of aluminium paint complete all as specified and directed by Engr-in-charge
All as per item no. 46.00 above, but steel tubular pole of 11 mtr long complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and directed by Engr-in-Charge.
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv (size 2x1m) for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed by Engr-in-charge.
Supplying and laying guard wire (cradle line ) rectangular fabricated with 3.15 mm GI wire complete all as specified and directed by the Engr-in-Charge.
M&L for Anti-climbing device spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed by Engr-in-Charge.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed by Engr-in-charge
Credit Note:- The accepted amount will arrived after deducting the sch of credit i.e. 52,315.00 as tender page number 32.
SUMEET TRADING CORPORATION
M/S ZTECH
EVERGREEN GROUP OF INDUSTRIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .