| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder, Hence accepted | |
| 2 | L2₹17.5 L+₹2.8 L (19.1%)Rejected-Finance 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLEGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 3 | L3₹18.3 L+₹3.6 L (24.3%)Rejected-Finance 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L3 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 4 | L4₹19.6 L+₹4.9 L (33.4%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L4 | Rejected-Finance Not Lowest Bidder, Hence Rejected | |
| 5 | L5₹20.7 L+₹5.9 L (40.3%)Rejected-Finance VILLAGE SATOJ TEHSIL SUNAM DISTT SANGRUR | SANGRUR | PUNJAB | 148001 | L5 | Rejected-Finance Not Lowest Bidder, Hence Rejected |
Tender Value
Refer Docs
EMD Value
₹46,340
Closing Date
18 Feb 2021, 6:00 pmClosed
GE (AF) PHALODI
Military Engineer Services Garrison Engineer (AF) Near Kundal Village, Phalodi (Rajasthan)-342 301
PROVN OF STORAGE ACCN (B/R-II) AND CHEMICAL EARTHINGS AT VARIOUS LOCATIONS (E/M) AT AF STN PHALODI
2021_MES_415296_1
8269/A/E8
Open Tender
Civil Works
Item Rate
180 days
PHALODI
All contractors enlisted with MES in Class E and above and category a (i)/b(i) subject to the remarks wrt performance in respect of Wks in hand reflected in Workload return (WLR) Circulated by competent engineer authority.
7 documents required · 7 mandatory
₹500
GE (AF) PHALODI
₹46,340
Yes
19 Apr 2021
22 Jan 2021
22 Feb 2021
22 Jan 2021
18 Feb 2021
6 Feb 2021
22 Jan 2021 - 1 Feb 2021
Amount
B/R Works :- Surface dressing n.exc 15 cm deep and getting out in soft/ loose soil complete all as specified and directed. Note :- Watering and removing surplus soil to a distance n exc 50m and making good surface deemed to be included in quoted rate.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes or for laying underground cable, pipe lines etc. in soft/loose soil, complete all as specified & directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes or for laying underground cable, pipe lines etc. in any type of soil, complete all as specified & directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in any type of soil complete all as specified and directed.
Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M & L for broken stone or boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified and directed.
M & L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in pathway or sub base of floors, finished the surfaces even and fair complete all as specified and directed.
M & L for 40mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) as in flooring laid adopting panel dimension not exceeding 1200mm x 1200mm, finished even and smooth without using extra cement and including making impressions of expanded metal, whilst the concrete is green complete all as specified and directed. Note:- Glass dividing strips shall be measured and paid for separately as "Supply only” under serial item No. 10 (here-in-below) of this BOQ.
Supply only glass dividing strips 38mm wide, 3mm thick and inserted in position complete all as specified and directed.
M & L for setting coat 5mm thick, CM 1:2, as in skirting, trowelled to even and smooth finish complete all as specified and directed.
M & L for 75mm thick PCC 1:2:4, type B-2 using 40 mm graded stone aggregate as in plinth protection laid in slope in 1:30 in alternative bays not exceeding 2 mtr in length. Exposed surfaces finished even and smooth without using extra cement including raking out joints between panel to panel and panel to wall and plugging the same with bitumen mastic using bitumen and sand mixture in 1:3 complete all as specified and directed.
M & L for providing cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating & including use and waste of formwork (straight or curved) all exposed surface of concrete finished fair complete all as specified and directed.
M & L for providing cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating & including use and waste of formwork (straight or curved) all exposed surface of concrete finished fair complete all as specified and directed.
M & L for providing precast cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in louvres and jallies, 25mm thick (measured solid), including all mouldings but excluding frame set in cement mortar 1:4, complete all as specified and directed.
M & L for soft/loose earth filling under floors and including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick each and consolidation complete all as directed. Note:- Earth obtained from item Nos. 02 & 03 (here-in-before) shall be used.
M & L for anti-termite treatment to the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
M & L for anti-termite treatment to the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M & L for anti-termite treatment to the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
M & L for 40mm thick cement concrete 1:2:4 Type B-0 (12.5 mm graded crushed stone aggregate) as in Damp proof course to horizontal or vertical surfaces & including necessary formwork complete all as specified and directed.
M & L for PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate as in padding and levelling course on roof and terrace laid to a consolidated thickness of 25mm, finished even & fair, laid and compacted in slope complete all as specified & directed.
Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.5 Kg/Sqm of make super thermolay manufactured by STP Ltd or ‘Hyper Plas’ (Polyster) manufactured by M/S IWL Ltd or ‘Shaliplas’ (polyester) manufactured by M/S Capital Steels and chemicals Pvt Ltd or Hydrostop water proofing memdrane manufactured by M/S TIKIDAN as approved by GE, black finish reinforced with non-woven polyester matt (weighing not less than 150 gm/Sqm), with a thermo fusable finish laid over compatible bitumen primer (Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd} at the rate of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing with a coat of cold emulsion bituminous primer all as per manufacturer’s instructions, over and including screed bed or bedding layer of mortar, 10 mm thick, in cement mortar 1:3, for laying floor finishes complete all as specified and as directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, applied @1.20 Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40 Kg/Sqm. (ii) Polymeric membrane shall be taken to a height of 60cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimuim) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimny/other vertical surfaces and polimeric membrane insterted in groove and sealed with paving bitumen. (v) Exposed surfaces of APP membrane shall be applied with one coat of bituminous aluminium paint @ 150 ml/Sqm. (vi) Above aspects are deemed to be included in quoted rate.
M & L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
M & L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shapes required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S & F for 1.25mm thick steel rolling shutters, without ball bearing & incluidng top cover, anchrong rod, hasp and staple and one shop coat of primer; erected in position as indicated, gear operated type with bevel gear box and crank handle complete all as specified and directed.
M & L for safety lever locks mild steel with 4 leavers for rolling shutters of approved make complete all as specified and directed.
M & L for reinforced cement concrete Design Mix M-25 as in foundations, including rafts, footings, foundations beams, plinth beams, bases for columns etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
M & L for reinforced cement concrete Design Mix M-25 as in columns, pillars piers, posts & struts etc complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
M & L for reinforced cement concrete Design Mix M-25 as in beams, cantilevers, bressummers and lintels over 1.5m span complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
M & L for reinforced cement concrete Design Mix M-25 as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
M & L for reinforced cement concrete Design Mix M-25 as in Chajjas complete all as specified and directed. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of the BOQ.
Use and waste of flat formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished surfaces of concrete complete all as specified and directed.
Use and waste of flat formwork to sides of pillars (square, rectangular or polygonal), posts, struts, piers, columns and stanchions for fair finished surfaces of concrete complete all as specified and directed.
Use and waste of flat formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished surfaces of concrete complete all as specified and directed.
Use and waste of flat formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) for fair finished surfaces of concrete complete all as specified and directed.
Use and waste of flat formwork to chullah hoods, chajjas, troughs and similar items including edges for fair finished surfaces of concrete complete all as specified and directed.
Use and waste of flat formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for fair finished surfaces of concrete complete all as specified and directed.
M & L for precast cement concrete 1:5:8 (using crushed stone aggregate) block masonry with solid blocks exc 10cm in width and setting in cement and sand mortar 1:6 complete all as specified and directed.
M & L for precast cement concrete 1:5:8 using 20mm crushed stone aggregate solid block, building blocks or slabs not exc 10cm thick (with plain or interlocking joint) and setting in cement and sand mortar 1:4 complete all as specified and directed.
M & L for plastering 5mm thick on concrete surface of ceiling in CM 1:3, finished even and smooth with using extra cement complete all as specified and directed.
M & L for rendering 10mm thick in cement mortar 1:4 on fair faces of brick work, PCC block masonary or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified.
M & L for rendering 15 mm thick in two layers on fair faces of brick/PCC block masonry of walls, first layer 10mm thick in cement mortar 1:6 and second layer 5mm thick in CM 1:4 mixed with WPC 3% by wt of cement and finished even and smooth without using extra cement complete all as specified and directed. Note :- Supply only WPC shall be measured and paid separately under respective item of the BOQ.
Supply only integral water proofing compound ISI marked as approved complete all as specified and directed.
M & L for preparing newly plastered surfaces of wall and applying three coats of white wash on walls complete all as specified and directed.
M & L for preparing newly plastered surfaces and applying three coats of white wash on ceiling/soffits of chajjas complete all as specified and directed.
M & L for preparing newly plastered walls surfaces and applying two coats of cement base paint over and including one coat of alkali-resistant priming paint complete all as specified and directed.
M & L for preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of 1st grade quality over and including a coat of red oxide primer complete all as specified and directed.
E/M ITEMS :- M & L for point wiring for one light point / bell point controlled by one, 1 way switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FR-LSH in and including non metallic rigid PVC heavy duty concealed conduit not less than 20 mm dia, ISI marked, including new steel terminal sunken pressed type boxes with 3mm thick plastic laminated bakelite (Hylam) sheet top cover for mounting switches, sockets, regulators, bell push etc, for one light point, fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm multi stranded copper conductor cable FR-LSH connected to common earth dolly complete including cutting, chasing the surface and then making good the same in CM (1:3) and finishing the surface to match with existing surface etc complete all as specified and directed. Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items here-in-after of BOQ (Sch 'A' ). Make of wire :- Anchor/Havells/Polycab/Finolex. Make of conduit :-Polycab/Plaza/kalinga/precision.
All as per srl item No. 48.00 (here-in-before) but for one 3 pin socket out let 5 Amp on same board complete all as specified and directed.
All as per srl item No. 48.00 (here-in-before) but for 3 pin 15 Amp socket out let by using 2.5 Sqmm PVC insulated unsheathed copper conductor cable FR-LSH multi strand on independent board & including provn of 1.5 Sqmm unsheathed, multi stranded copper conductor cable FR-LSH continues as earth wire connected to earth dolly etc complete all as specified and directed.
S & F switch piano, flush type, one way, 5/6 Amps, 240 volts, AC (ISI marked) complete all as specified & directed.
S & F socket outlet, 5 pin, 5/6 Amps, flush type, 240 volts, AC (ISI marked) complete all as specified & directed.
S & F Switch socket combination 2 in 1, 3 pin, 5 and 15/16 Amps, flush type, universal, 230 volts, ISI marked complete all as specified & directed. Note:- Switch and socket shall be of same make.
S & F ceiling rose surface bakelite 65 x 50mm size, two to three phase terminals with back plate, ISI marked complete all as specified and directed.
S & F of LED batten light fitting 1 x18/20 Watt, 6000K, 4"" with polycarbonate environment friendly, energy efficient with all light fitting connection with 2 core flexible cable 23/0.00076 from ceiling rose to light fitting connection etc complete all as specified and directed.
S & F of LED light fitting, 1X25 Watt, 5700 K, with tuff net glass, IP:66 protection, fixed to walls with & including GI bracket made out of light grade GI pipe 32 mm dia upto 1.2 mtr length bent to shape with 02 sets of MS clamps made out of 25x3 mm MS flat iron with suitable bolt and nuts and testing etc and including connecting with twin core copper conductor FR-LSH cable size as per existing etc complete all as specified and directed. Make:-Cat part No LHETAXU7PA6S025 of Havells or equivalent Make/Model to Crompton/Bajaj.
S & F of factory made sheet metal enclosure made out of CRCA sheet for double door distribution board with epoxy powder coated concealed surface mounted SPN 4 way, protection class IP-43 suitable for mounting MCBs, isolator etc. conforming to IS-8623, BS-5484 with 200 Amps rated copper bus bar stove enameled dust and vermin proof suitable for working on 240 volts, AC supply complete all as specified & directed.
S & F of MCB SPN 32 Amp, 'C' curve having rupturing capacity 10 KA confirming to IS-8828-1996, IEC-60898, complete all as specified & directed.
S & F of MCB single pole 6 to 32 Amp, 'C' curve having rupturing capacity 10 KA confirming to IS-8828-1996, IEC-60898, complete all as specified & directed.
Supplying, laying, jointing, testing and commisioning of cross sectional area 10 Sqmm, 4 core, LT under ground cable, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 1100 Volt grade, laid in trenches / ducts / encased in GI pipe / fixed to pole/wall complete all as specified and directed Note :- Exacavation and earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid seprately under respective items of the BOQ.
M & L for dry tibba sand free from clay for cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover to cable all as per standard schedule rates Part-I (2009) complete all as specified and directed. Note:- Thickness after punning shall be considered for payment.
Supplying and laying of un-reinforced precast cement concrete cable cover, Class LV, Type-I, flat, size 250 mm x 150mm x 40mm laid dry and abuting each other with gap between adjecent cover not exceeding 10mm over UG cable for protection complete all as specified and directed.
Supply, laying, jointing and testing 15mm bore dia GI steel water tubing, galvanized, medium grade and including with all fittings such as bends, tees, union etc.(ISI marked), fixed to walls and ceilings or laid in floors complete all as specified and directed.
S & F of Gun metal bib tap suitable for 15mm bore dia of pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked complete all as specified and directed.
S & F of Copper strip of size 20mm x 3.15mm with saddels and fixing screws for roof conductors and down conductors above ground and earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/ pipe or fixed to poles or fixed to wall on insulators or any other indicated situation for loop earthing etc as required complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to galvanized earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 40mm bore for protection of GI earth wire and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 3 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point including testing complete all as specified and directed. Note : (i) The cost of earth lead /strip and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate. (ii) The cost of excavation, earth work & PCC etc are included in the quoted rate. (iii) On testing after completion, if the earth resistance less than 0.5 Ohms is not obtained earthing will be regenerated at no extra cost till the desired earth resistance is obtained.
M & L for chemical earthing with copper earth plate electrode 90 cm X 60 cm X 5 mm thick buried directly (vertically) in ground (earth pit not less than 3.0m deep below ground level), with top edge of earth plate not less than 2.25 m below ground level, connected to and including copper strip of size 32mm x 6 mm as earthing strip by means of bolts, nuts, check nuts and washers etc., made of copper and connected to test point and earth dolly including all joints as shown in drawing and including provision of supplying and laying charcoal dust 400 Kg, common salt 400 Kg, and Magnesium Sulphate 80 Kg and all around the plate upto 15cm depth, length & width upto 650mm in continous layers, balance portion of the pit will be filled with vegetable soil upto ground level and including excavation and earth work in any type of soil, RCC 50mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, Set in CM 1:4 and PCC 1:3:6 type C1 in chamber, Precast concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Sqm) with cast iron frame, PGI funnel with wire mesh, 40mm dia GI pipe medium grade for watering, lugs, 40 mm bore light grade GI protection pipe upto 7.5 m all as shown in electrical plate No 3 on Srl Page No 497 of SSR Part I (2009) drawing and connection to earth test point including testing, writing of details on the surface of the pit with paint complete all as specified and directed. Note : (i) Outer edge of earth pit shall be 1 metre away from the outer edge of PCC chamber. (ii) The cost of 7.5m earth lead /copper strip and GI pipe for protection of earth lead & watering/strip upto 7.5m are included in the quoted rate. (iii) The cost of excavation, earth work, RCC & PCC etc are included in the quoted rate. (iv) The approved vegetable soft soil filled in the pit deemed to be included in the quoted rate. (v) On testing after completion, if the earth resistance less than 1 Ohms is not achieved earthing will be reconstructed at no extra cost till the desired earth resistance is obtained.
M & L for earthing complete using with copper plate electrode 60cmx60cm x3.15mm thick buried directly (vertically) in ground (earth pit not less than 3.0m deep below ground level), with top edge of earth plate not less than 1.5 m below ground level, connected to and including copper strip 20mmx3mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints as shown in drawing and including excavation and earth work, GI pipe light grade 40mm bore for protection of strip and connected to continous earth lead on pole/test point, including supplying and laying charcoal dust, common salt, PCC 1:2:4 type B1, chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6mm dia round bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh, 20mm dia GI pipe medium grade for watering all as shown in electrical plate No 3 on srl page No 497 of SSR Part I (2009) drawing and connection to earth test point including testing, writing of details on the surface of the pit with paint complete all as specified and directed. Note : (i) Outer edge of earth pit shall be 1 metre away from the outer edge of PCC chamber. (ii) The cost of 7.5m earth lead /copper strip and GI pipe for protection of earth lead & watering/strip upto 7.5m are included in the quoted rate. (iii) The cost of excavation, earth work, RCC & PCC etc are included in the quoted rate. (iv) The approved vegetable soft soil filled in the pit deemed to be included in the quoted rate. (v) On testing after completion, if the earth resistance less than 1 Ohms is not achieved earthing will be reconstructed at no extra cost till the desired earth resistance is obtained.
Supplying and laying/fixing GI tubing light grade 40 mm bore dia for encasing cables /strip for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or along poles or as street light poles or as mounting bracket bend to shape with complete accessories such as bends/sockets/reducers/saddles & incl necessary threading/drilling works complete all as specified and directed.
M/S HARIOM CONSTRUCTION COMPANY
M/S SOLANKI GENERAL SUPPLIERS
KRISHNA CONSTRUCTION COMPANY
M/S SIDHU CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .