Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC JOYNAGAR MIDDLE ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical NEAR RAMNAGAR ROAD NO 2 TG ROAD AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799002 | - | Rejected-Technical L3 | |
| 3 | Rejected-Technical 31 A K ROAD AGARTALA | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | - | Rejected-Technical L2 |
| Sl No | Description | Qty | Unit | STANDARD ELECTRONICS L2 | Eastern Commerce L3 | R.P.ELECTRONICS L1 |
|---|---|---|---|---|---|---|
| 1.00 | Providing in/c testing and commissioning (except Installation) of Split type Hi-wall 1.50 TR (4,500 Kcal/ hr.) A.C. Machine with Inverter Compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391 (Part-II) specification (Evaporator & Condenser must have copper pipe), suitable for operation on 230 volt +- 10%, not less than 3 (Three) Star rating (2019 Standard), 50Hz, Single Phase AC Supply capable of performing a) Cooling, b) Dehumidifying, c) Air Circulation, d) Filtering, as per direction of the Engineer-in-Charge | 10 | job | 40,000 ₹4,00,000 | 3,87,900 ₹38,79,000 | 38,000 ₹3,80,000 Lowest |
| 2.00 | Providing in/c testing and commissioning (except Installation) of Split type Hi-wall 2.00 TR (6,000 Kcal/ hr.) A.C. Machine with Inverter Compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391 (Part-II) specification (Evaporator & condenser must have copper pipe), suitable for operation on 230 volt +- 10%, not less than 3 (Three) Star rating (2019 Standard), 50Hz, Single Phase AC Supply capable of performing a) Cooling, b) Dehumidifying, c) Air Circulation, d) Filtering, as per direction of the Engineer-in-Charge. | 38 | job | 54,990 ₹20,89,620 | 53,496 ₹20,32,848 | 50,800 ₹19,30,400 Lowest |
| 3.00 | Standard installation of 1.5 TR/2.00 TR capacity Hi-Wall Split type Air Conditioner in/c repairing of drilled wall by cement mortar, painting in/c necessary insulation, clamping and warping by white masking tape of copper pipes, and also providing electrical 3 pin 16 amp Top for connection in socket & necessary scaffolding etc. complete as per direction of the Engineer-in-Charge. | 48 | jobs | 3,000 ₹1,44,000 | 2,500 ₹1,20,000 Lowest | 4,500 ₹2,16,000 |
| 4.00 | Providing and fitting fixing of copper pipe (suction & discharge) for split AC (5/8'',1/4'') suitable size as per direction of the Engineer-in-Charge. | 290 | Mtr. | 500 ₹1,45,000 Lowest | 990 ₹2,87,100 | 510 ₹1,47,900 |
| 5.00 | Providing and connecting Electric Control cables between indoor unit and outdoor unit beyond standard quantity kit. 3C X 2.5 Sq. mm Copper Cable. | 290 | Mtr. | 70 ₹20,300 Lowest | 190 ₹55,100 | 100 ₹29,000 |
| 6.00 | Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge. | 48 | nos | 1,000 ₹48,000 | 996 ₹47,808 Lowest | 2,500 ₹1,20,000 |
| 7.00 | Providing hard PVC pipe of good quality of at least 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-Charge. | 240 | Mtr. | 70 ₹16,800 | 55 ₹13,200 Lowest | 100 ₹24,000 |
Tender Value
₹34.5 L
EMD Value
₹69,064
Closing Date
7 Nov 2024, 3:00 pmClosed
Executive Engineer
Executive Engineer Mechanical Division Agartala
Providing Installation and commissioning of 1.5_2.0 TR capacity Split Type High Wall inverter Compressor Technology Air Conditioning Machines in the newly constructed MCH building of Gomati District Hospital Udaipur
2024_CEPWD_53972_1
08_B_DNIeT_SE_PWD _202425
Open Tender
Electrical Works
Works
90 days
Udaipur
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹69,064
2 Sept 2025
19 Oct 2024
7 Nov 2024
19 Oct 2024
7 Nov 2024
19 Oct 2024
Amount
Providing in/c testing and commissioning (except Installation) of Split type Hi-wall 1.50 TR (4,500 Kcal/ hr.) A.C. Machine with Inverter Compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391 (Part-II) specification (Evaporator & Condenser must have copper pipe), suitable for operation on 230 volt +- 10%, not less than 3 (Three) Star rating (2019 Standard), 50Hz, Single Phase AC Supply capable of performing a) Cooling, b) Dehumidifying, c) Air Circulation, d) Filtering, as per direction of the Engineer-in-Charge
Providing in/c testing and commissioning (except Installation) of Split type Hi-wall 2.00 TR (6,000 Kcal/ hr.) A.C. Machine with Inverter Compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391 (Part-II) specification (Evaporator & condenser must have copper pipe), suitable for operation on 230 volt +- 10%, not less than 3 (Three) Star rating (2019 Standard), 50Hz, Single Phase AC Supply capable of performing a) Cooling, b) Dehumidifying, c) Air Circulation, d) Filtering, as per direction of the Engineer-in-Charge.
Standard installation of 1.5 TR/2.00 TR capacity Hi-Wall Split type Air Conditioner in/c repairing of drilled wall by cement mortar, painting in/c necessary insulation, clamping and warping by white masking tape of copper pipes, and also providing electrical 3 pin 16 amp Top for connection in socket & necessary scaffolding etc. complete as per direction of the Engineer-in-Charge.
Providing and fitting fixing of copper pipe (suction & discharge) for split AC (5/8'',1/4'') suitable size as per direction of the Engineer-in-Charge.
Providing and connecting Electric Control cables between indoor unit and outdoor unit beyond standard quantity kit. 3C X 2.5 Sq. mm Copper Cable.
Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge.
Providing hard PVC pipe of good quality of at least 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-Charge.
STANDARD ELECTRONICS (BID ID -155404)
Eastern Commerce (BID ID -155608)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_54830.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .