Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L3₹26.9 L+₹3.4 L (14.4%)Accepted-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L3 | Accepted-AOC L1 Bidder amongst bonafide bidder | |
| 2 | L1₹23.8 LRejected-Finance FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L1 | Rejected-Finance NON BONAFIDE. QUOTED BELOW MINIMUM WAGES. APPROVAL OBTAINED FROM PCDA | |
| 3 | L2₹24.1 L+₹34,144.68 (1.44%)Rejected-Finance | L2 | Rejected-Finance NON BONAFIDE. QUOTED BELOW MINIMUM WAGES. APPROVAL OBTAINED FROM PCDA | |
| 4 | L4₹28.2 L+₹4.4 L (18.6%)Rejected-AOC | L4 | Rejected-AOC L2 Bidder amongst bonafide bidder | |
| 5 | L5₹37.1 L+₹13.3 L (56.0%)Rejected-AOC | L5 | Rejected-AOC L3 Bidder amongst bonafide bidder |
Tender Value
Refer Docs
EMD Value
₹83,500
Closing Date
20 Oct 2020, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICES, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
OUTSOURCING OF SERVICES FOR LIFTS AT DESIDOC A BLOCK, SAG AND ELECTRICAL SUBSTATION AT DESIDOC B BLOCK , 180 KVA DG SET INSTALLATION AT DTRL AND CENTRAL AC PLANT 3X50TR ANIMAL HOUSE BUILDING DIPAS AND REPAIR/MAINTENANCE LT CABLE WORK AND ALLIED WOR
2020_MES_379892_1
GE/RND-36/DLI/2020-2021
Open Tender
Civil Works
Item Rate
330 days
DELHI
Class D, Cat d(v) and b(i)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹83,500
Yes
18 Dec 2020
22 Sept 2020
22 Oct 2020
22 Sept 2020
20 Oct 2020
8 Oct 2020
Amount
PART-1 OUTSOURCING SERVICES Outsourcing of services for manning and operation of electrically operated lift of capacity 05 passengers-01 No., suitable for G+5 (Ground+5 floors) installed at DESIDOC 'A' Block Make- THYSSEN KRUP to be operated in one shift per day (0830hrs to 1730hrs) and five days in a week (Monday to Friday, except holidays as declared by Lab) by deploying one skilled Operator cum Mechanic per shift per day complete all as specified and as directed.
Outsourcing of services for manning & operation of electrically operated lift of capacity 20 passengers - 01No, (1500 Kg) Passanger cum Freight lift suitable for G+6 (Ground+6 floors) installed at SAG Building Make- Sky Larc oF JOHNSONS to be operated in one shift per day (0830hrs to 1730 hrs) and five days in a week (Monday to Friday, except holidays as declared by Lab) by deploying one skilled Operator cum Mechanic per shift complete all as specified and as directed.
Outsourcing of services for manning & operation and routine maintenance of DESIDOC 'B' Block Sub Stn at M’House area in two shift per day (0600hrs to 1400 hrs Ist Shift and 1400hrs to 2200hrs 2nd Shift ) in all working days including Sunday & Holiday by deploying one skilled operator cum mechanic per shift per days complete all as specified and as directed. The installation mainly comprises of the following:- (a) Incoming VCB 11 KV800Amps, 50Hz, 3Phase, compete-02 Nos Make- CG. (b) HT Panel - 01 floor mounting consisting of the following :- (i) ACB 1000 Amps – 01 No, Make:-CG. (ii) MCCB 400 Amps – 02 Nos, Make:- Havells. (iii) MCCB 630 Amps – 01 No, Make:- Havells. (iv) MCCB 315 Amps – 01 No, Make:- Standard. (v) MCCB 250 Amps – 02 Nos, Make:- Havells. (vi) MCCB 200 Amps – 01 No, Make:- L&T. xxsa (vii) MCCB 100 Amps – 01 No, Make:- Yendrew Yule. (c) LT Panel - 02 floor mounting consisting of the following :- (i) MCCB 400 Amps – 01 No, Make:-Havells (ii) MCCB 400 Amps – 0 No, Make:- L&T. (iii) MCCB 225 Amps – 01 No, Make:- CG. (iv) MCCB 200 Amps – 01 No, Make:- Havells.. (v) MCCB 160 Amps – 01 No, Make:- ABB (vi) MCCB 100 Amps – 02 Nos, Make:- ABB. (d) Bus coupler 800 Amps - 01 No, Make:- CG (e) Change over of DG Set 400Amps - 01 No (f) Earthing complete for transformer, HT Panels & LT Panels.
Outsourcing of services for manning & operation of DG Set 180KVA at DTRL Sub Stn at M’House area to be operated in one shift per day (0830 hrs to 1730 hrs) in all working days including Sunday & Holidays by deploying one skilled operator cum mechanic per shift per days complete all as specified and as directed . The installation mainly comprises of the following :- (a) DG Set 180 KVA- 01 No. (b) AMF Panel- 01 No. (c) Batteries and Earthing complete (i) Diesel oil and engine oil will be supplied by department free of cost for running of DG set. The contractor is responsible to collect/transport the same from MES MT store yard at AGE E/M Office to requisite installation and topping up the same in DG sets.
Outsourcing of services for manning & operation of central AC plant 3x50TR capacity (02 Nos working at a time and 01 No. standby or in any combination) installed at ANIMAL HOUSE Building of DIPAS area to maintain inside ambient temperature conditions throughout running period by cooling or heating, in THREE SHIFTS of 8 hours each per day to be operated in the three shift per day (0600hrs to 1400 hrs Ist Shift, 1400hrs to 2200 hrs 2nd Shift, 2200hrs hrs to 0600 hrs 3rd Shift) from Monday to sunday including holidays by providing and deployment of one skilled mechnic cum operator per shift per day, including routine and periodical check ups and attending minor repair for proper functioning of plant, components such as compressor, condenser electric motors, pumpsets, AHU, blower motor, water suctions and discharge pipelines, refrigeration piping system alongwith functioning of interlocking system LP/HP outlet etc, including upkeep of the installation in clean and tidy condition internally and surrounding areas externally by cutting of grass and bushes /wild plants complete all as specified & directed . The plant/installation mainly comprises the following:- (i) Water cooled scroll chilling machine with Micro-processor based control panel. Condenser CDW IN : 32.22˚ C/90.00˚ F, CDW OUT : 36.39˚ C/ 97.50˚ F. Chiller CHW IN : 12.22˚ C/54.00˚F.CHW OUT˚:6.66˚C/44.00˚F. Pumps (ii) Condenser Water Pumps. (iii) FRP induced draft Cooling Tower of capacity 60 TR 2 Working + 1 Standby).
(iv) Hot Water Generator of capacity 30 KW in four banks complete. (One as standby). (v) Hot water Pumps. (vi) Non-Chemical Water Treatment Scale Preventor System : "Scale Guard" (vii) AHU (Ground/First Floor) 2400 CFM Supply Blower. (viii) AHU (Second floor) 3500 CFM Supply Blower. (ix) Closed Loop expansion tank. (x) Electric Panel cubical type. (xi) INCOMER 02 No. - 250 A 4 pole MCCB. (xii) Bus Coupler 01 No.-250A, 4 pole MCCB. OUTGOINGS. (i) For 03 Nos 50 TR Scroll water Cooled Chilling Machine. 03 Nos - 100Amp, 4 Pole MCCB. (ii) For 03 Nos 5.5 KW Condenser Water Pumps. 03 Nos - 40Amp TP MCB. (iii) For 3 Nos 3.7 KW Chilled Water Pumps. 03 Nos - 40Amp TP MCB. (iv) For 3 Nos 1.5 KW Cooling Tower, 03 Nos - 40Amp TP MCB. (v) For 01 No. 30 KW Hot Water Generator. 02 Nos - 100 Amp TP MCCB. (vi) For 2 Nos. 1.5 KW Chilled Water Pumps. 02 No. - 100 Amp TP MCCB. (vii) For 2 Nos 1.5 KW Chilled Water Pumps. 02 Nos - 40 Amp TP MCB. Note for ser item No 5.00:- (a) The AC plant shall be operated to maintain the specified inside design.
Rate required to be quoted for executing the work as described in Ser item No 1.00 to 5.00 above
Workers wage per person as per existing rules
ESIC (Employees state insurance contribution) as mentioned in tender document
Bonus as mentioned in tender documents
Overhead & Profit on Ser No 6.01 to 6.03
LWC as mentioned in tender documents.
GST as mentioned in tender documents.
Notes : Rate quoted by the contractor shall deemed to be included the following :- (i) Operator cum mechanic (skilled) shall be of Diploma/ITI passed with having training certificate in relevent trade not less than three year shall be employed for each shift.. (ii) It is an express condition of the contract that tenderers are required to quote their rates duly considered minimum applicable as per policy wages of the tradesmen intended in the tender, as in force on the end date of bid submission. It shall be deemed that quoted rates are based on minimum wages notified by the concerned authority for the station i.e Govt of India/State Govt/Union Teritory, whichever is higher including all statutory provisions such as EPF, GST, ESIC , Bonus, labour welfare cess (LWC) and contractor's overhead & profits etc as applicable. (iii) In case the rates quoted by tenderer are less than the notified minimum wages as on bid submission end date including all statutory provisions such as EPF, GST, ESIC, Bonus, labour welfare cess (LWC) and contractor's overhead & profits etc as applicable, his tender will be treated as non-bonafide and will not be considered for Acceptance. In such case, the lowest tender shall be determined amongst valid/bonafide bids only. (iv) The firm/contractor shall be solely and fully responsible to his reprsentative/personal for any accident/damage during maintenance/operation/health related liabilities/compensation, penelty etc on this account. (v) T&P required such as spanner set, wrench, screw driver set, testing lamp, drilling machine and multimeter, tong tester, megger etc as well as protective devices (shoes, helmet etc) shall be provided by the contractor at no extra cost.
(vi) Contractor shall be responsible to maintain log books, duty roster attendance register and spare for repair/renewal of parts register, earth register, serviceability register of lifts and as directed by Engr-in-charge. (vii) Shift Operator (reliever) shall neither leave the installations without prior permission of JE/Engineer-in-Charge. Proper handing/taking over to the next operator will be made. (viii) Two pairs of uniform with name plate of operator & firm and shoes shall be provided to each operator by the contractor. (ix) Cleaning of complete lift, machine room of lift, greasing, tightening of nuts , bolts will be carried out by the operator employed by the contractor. (x) First Aid box will be provided by contractor at each installation. (xi) Any increase in minimum wages of labour as fixed by the Govt of India/state Govt/ union Territory, whichever is higher shall be paid to the contractor in accordance with the provision made vide condition 63 of IAFW-2249. Increased wages including all other benefits in compliance of statutory provisions shall be paid to workers by the contractor. no other claim whatsoever shall be addmissible on this account and the bidders shall consider this aspect while quoting their rates. It must be noted that in compliance of the statutory provisions, the increased will be passed over to the workers. (xii) Any consumble item shall be issued by department free for fixing/filling. The contractor shall collect and transport the same from E/M store yard to the requisite installations within 24 Hours at his own cost and arrangement. Proper record for issue & receipt for this shall be maintained by the Engineer-in-Charge & contractor.
(xiii) The Contractor shall not pay wages lower than the latest notified minimum wages in force to their workmen/ tradesmen including all other benefits in compliance of statutory provisions. Bidders shall consider this aspect while quoting their rates. (xiv) Duty roster for detailement of operators shall be approved by Engr-in-charge within first three days of every month and the same shall be kept on record and properly displayed at each installation. (xv) The contractor will arrange the earth tester, Megger & clamp meter for installation and will check all the earthings of lifts for its serviceability in presence of JE E/M, Engr-in-Charge and test report shall be submitted to the office of AGE E/M duly signed by the contractor on commencement of work for record. (xvi) For any damage to the installations due to negligence of operator such as loose connections, improper routine check up/maintenance etc. the contractor shall be held fully responsible to replace the same damage at his own cost all as directed by Engr-in-charge. (xvii) Original certificates regarding qualifications of operators engaged in the work, police verification and identity proof shall be produced by the contractor to the Engineer-in-Charge for verification and approval.
PART-II : REPAIR/MAINT WORK S&F in repair 3 Pole MCCB, 100 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and directed.
S&F in repair of 3 Pole MCCB, 125 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and directed.
S&F in repair of 3 Pole MCCB, 160 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and directed.
S&F in repair of 3 Pole MCCB, 250 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and directed.
S&F in repair of 3 Pole MCCB, 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and directed.
S&F in repair of 4 Pole MCCB, 160 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and directed.
S&F in repair 4 Pole MCCB, 250 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and directed.
S&F in repair of 4 Pole MCCB, 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and directed.
S&F voltmeter digital type for voltage range of (0-500V) including all accessories and wiring complete all as specified and as directed.
S&F ammeter digital type for current range of (0-1000Amps) as per matching to existing including all accessories and wiring complete all as specified and as directed.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25x4 mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 25x4 mm galvanised iron strip including taking down old unserviceable complete all as specified and directed.
Supply, laying connecting and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core including taking out old unserviceable cable complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5m depth & not exceeding 1.5m in width for taking out and laying of LT Cables etc complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick as in soft/loose soil complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level and not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
Supply & laying dry fine sand for cushioning of underground cable laid in trenches/duct complete all as specified and as directed.
Supply & laying sub class 'B' burnt brick flat across the cable, for protection of cable laid in trenches complete all as specified and directed.
Disconnecting & Taking out old unserviceable joints & Supplying, Fixing, Jointing & testing for provision of straight through heat shrinkable joints, epoxy tube with epoxy jointing materials suitable for XLPE, LT Cable 1100 Volts grade, for size 50 Sqmm to 300 Sqmm 3.5 Core all as specified and directed.
Supply and laying GI pipe medium grade in replecement of old unserviceable 100mm dia laid in trenches for protection of UG cable complete all as specifed and directed.
S&F in repair ARD Battery for lifts 12 Volts 7AH complete all as specified and directed.
S&F in repair cabin light LED as per existing make and type or as per OEM specification for lift complete all as specified and directed.
S&F in repair lift cabin fan as per existing make & type or as per OEM specefication for the lift complete all as specified and directed.
S&F in repair Steel Wire Rope for lift of size 13mm and as per OEM specification for the lifts complete all as specified and directed.
S&F in repair Lift Door sensor as per OEM specification or as per existing Model and make complete all as specified and directed.
M&L in repair of control wiring for Lift Panel with 2.5 Sqmm 3 core multistranded FRLSH copper conductor cable as per existing complete all as specified and directed.
S&F in repair of push button with indicator as per OEM specification for the lifts complete all as specified and directed.
GEMINI ENTERPRISES
Pradeep Bros
RUHI ASSOCIATES
Choice india
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .