Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC 25 RAHUTA ROAD SHYAMNAGAR 24 PGS N | SHYAMNAGAR | 24 PGS | WEST BENGAL | 743127 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.8 L+₹1.3 L (19.5%)Rejected-Finance DHARSHA NEAR MATH P O GIP COLONY DIST HOWRAH PIN 711112 | HOWRAH | HOWRAH | WEST BENGAL | 711112 | L2 | Rejected-Finance 781431.00 | |
| 3 | L3₹8.5 L+₹2.0 L (29.8%)Rejected-Finance 133 GARFA MAIN ROAD KASBA KOLKATA 700078 | KOLKATA | KOLKATA | WEST BENGAL | 700078 | L3 | Rejected-Finance 848783.80 | |
| 4 | L4₹9.8 L+₹3.3 L (50.3%)Rejected-Finance 22 GROUND FLOOR POTTERY ROAD TANGRA KOLKATA WEST BENGAL 700015 | KOLKATA | WEST BENGAL | 700015 | L4 | Rejected-Finance 982427.00 |
Tender Value
₹12.0 L
EMD Value
₹23,996
Closing Date
18 Feb 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer PWD BDN ELEC DIVN
Room no 1081st fl purta bhawan salt lake kolkata
E I work of compound light arrangement of Open Campus cum Regional Centre of NSOU at New Town Kolkata
2021_WBPWD_320655_1
WBPWD/EE/BED/29/e-IT of 2020_21
Open Tender
ELECTRICAL WORKS M/R
Item Rate
14 days
NSOU new town
Please refer Tender documents.
5 documents required · 5 mandatory
₹23,996
Yes
31 Mar 2021
28 Jan 2021
22 Feb 2021
3 Feb 2021
18 Feb 2021
3 Feb 2021
120 days
Amount
Supply & installation of 3" dia 2 mtr long ISI medium GI Pole at the roof top of the Sub Station room.(make- Bansal/Jindal/Utkarsh)
Making RCC foundation (4:2:1) having dimension 1500 mm x 600 mm x 600 mm with Pakur varaity Stone chips including S&F 8 mm MS rod reinfoecement with necessary wooden shuttering and S&F 4 nos. 500 mm long 16 mm dia long thread galvanized foundation bolt with double nut and washers etc. for errection of above /bolted pole as per approval of EIC.
S & F CMDA type detouchable single arm header assembly of 1.5 mtr length, 40 mm dia & having a top cap of dia 100 mm & 6" length with suitable screw and nuts by connecting and welding the top caps
S & F CMDA type detouchable single arm header assembly of 1.5 mtr lengthwith 180 deg between two arm, 40 mm dia & having a top cap of dia 100 mm & 6" length with suitable screw and nuts by connecting and welding the top caps.
Supply & fixing of 180 watt 5700K LED, luminious efficiency not less than 10 Lm/Watt and system efficacy of > 110 LPW Flood Light Luminaries should be fixed at the GI poles with special angle iron frame ( Make: Crompton, Model Pluto Neo, Cat no- LFLN-180-CDL/60-M / Philips/ Wipro)
Supply & installation of 40 watt LED post top Lantens at the four nos entry and exit gates (Havells, Victoria / Philips / Wipro)
Supply & installation of 150 watt LED Flood Light Fittings with all accesssories as required for illuminating the vacant field of the site. (Make- Crompton, Pluto, Cat-LFLN-150-CDL/60-M/Philips/Wipro)
S & Laying of 4 core 16 sq mm XLPE/PVC Al conducter armoured cable through GI pipe with all jointing accessories (Make :- Havells/Finolex/polycab/RR kabel)
S & Laying of 4 core 16 sq mm XLPE/PVC Al conducter armoured cable on wall as per GS (Make :- Havells/Finolex/polycab/RR kabel)
Supply and fixing of smc junction box size 140 x 140 x 95. (Make :- Syntex/Similar make)
Distribution wiring in 1.1 KV single concrew standard FR PVC insulated & unsheated copper wire (brand approved E.I.C.) 2 x 36/0.3 (2.5 sq mm)+1 x 22/0.3 (1.5 sqmm) .
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. i)2.5 sq mm
ii) 1.5 sq mm
Earthing by 50 mm dia by ISI medium GI pipe of 3.64 mm thick & 1.8 mtr with 6 swg Hot Dip wire soft soil including 13 mm dia 80 mm long GI bolts as pole for st pole earthing with addition for charcol & salt for st pole, deco pole & garden lighting
Supplying & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing metarials as required. 50 mm dia ISI-M GI Pipe
Supply & fixing of Timer control panel on wall comprising of :- i) 230V AC 3 phase MNX 40 Mini power contactor - 1 nos ii) Digital timer / Dial type Analogue Timer 24 hours capacity, 230V, AC supply. iii ) 230V, 40A FP MCB, C type. iv) 230V AC toggle switch, single pole Double throw, 40 A, 230V. v) 230V, 40A, 3 way terminal. vi) 15A, 8way nutral bar, to be mount on DIN rail with necy interconnection with 1.5 sqmm cu flexible wire ( Finolex / Havells )including ferrule marking & socketing within the 13inch x 41 inch x 8 inch enclosure box. (Make: L&T/ABB/Hagar/Crabtree)
Supplying and fixing 240/415 V 63amp. 4P MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection in 4 way MCB encloser (Make- Legrand/ L & T/ Siemens)
Supplying and fixing 240/415 V, 32 Amp 3P MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make- Legrand/ L & T/ Siemens)
L.W.C. must be quoted manually @1% on the total quoted value else the total quoted rate shall be treated incl. LWC as per rule. N.B. Rate should be quoted inclusive of GST.
ULTRA ELECTRICALS AND ELECTRONICS
Prava Enterprise
A.B. ENGINEERING CO
stage.html
html • 0.05 MB
technical_608164.pdf
PDF • 0.09 MB
techsummary_608164.pdf
PDF • 0.09 MB
finance_608164.pdf
PDF • 0.08 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_608164.pdf
PDF • 0.09 MB
AOC.pdf
PDF • 0.29 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .