Loading…
Loading…
Tender ID
Tender Value
₹93.8 L
EMD Value
₹1.9 L
Closing Date
25 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
WA
16 conditions · 3 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees. N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of Indian Railways Standard General Conditions of Contract, GCC - April 2022, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Similar nature work means Tenderer should have experience on: "Execution of any 1500V DC or 25 kV AC OHE work." (Authority: PCEE- WR/CCG's letter No.EL/90/TRD/W/1 dated 21.01.2009)
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
OHE modification in connection with electrification of direct connectivity from SBI-B to ICD from line no 9 and engineering replacement of existing steel girder by PSC U type slab
TRD-ADI-T-12R3-2025-26
TRD-ADI-T-12R3-2025-26
Open
Works - General
8 Months
Ahmadabad, Gujarat
₹0
₹1.9 L
25 Mar 2026
25 Feb 2026
11 Mar 2026
86 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 57,23,368.5 | ||
| — | Breakup | for details. | — | ||
| 1.Preparation of all drawing and design for overhead equipment including preparation of SED and OHE layout plan | — | — | — | 30,013.5 | |
| — | Breakup | for details. | — | ||
| 2.Preparation of SWR diagram board along with caption diagram | — | — | — | 54,200 | |
| — | Breakup | for details. | — | ||
| 3.Supply and erection of fabricated galvanised steel structure and SPS as per specification | — | — | — | 21,06,000 | |
| — | Breakup | for details. | — | ||
| 4.Concrete for foundation and plinth in all type of soil incl. hard/rocky soil (incl. excavation and supply of all material viz. sand, cement, and ballast, etc.) | — | — | — | 7,59,330 | |
| — | Breakup | for details. | — | ||
| 5.Supply & erection of single cantilever assembly complete with insulators for OHE | — | — | — | 8,83,470 | |
| — | Breakup | for details. | — | ||
| 6.Supply & erection of regulating equipment 3 pulley type complete with all accessories including counter weight assembly and SS wire rope (ATD) | — | — | — | 3,40,700 | |
| — | Breakup | for details. | — | ||
| 7.Supply and erection of material for termination of double conductor (including supply of 9 ton cut in insulator) of overhead equipment. | — | — | — | 83,190 | |
| — | Breakup | for details. | — | ||
| 8.Supply of in-span droppers with dropper clips etc as per explanatory note | — | — | — | 1,81,080 | |
| — | Breakup | for details. | — | ||
| 9.Supply of 160 sqmm different types of jumpers with fittings i. e. PG clamps | — | — | — | 1,12,150 | |
| — | Breakup | for details. | — | ||
| 10.Erection of materials for splicing & extension of anchored OHE. | — | — | — | 20,943 | |
| — | Breakup | for details. | — | ||
| — | Breakup | for details. | — | ||
| — | — | — | 20,940 | ||
| — | Breakup | for details. | — | ||
| Supply of different type of caution boards. | — | — | — | 22,300 | |
| — | Breakup | for details. | — | ||
| Transfer of OHE from one mast to another mast and adjustment of droppers | — | — | — | 1,29,680 | |
| — | Breakup | for details. | — | ||
| Supply & erection of guy rod assembly | — | — | — | 95,688 | |
| — | Breakup | for details. | — | ||
| Supply of Contact wire splice | — | — | — | 11,680 | |
| — | Breakup | for details. | — | ||
| Supply of Catenary wire splice | — | — | — | 7,670 | |
| Supply and erection of 25kV single pole, 1600A isolator complete, with or without earthing heel | — | — | — | 2,01,638 | |
| — | Breakup | for details. | — | ||
| Erection of OHE complete | — | — | — | 73,266 | |
| — | Breakup | for details. | — | ||
| Supply and erection of section insulator assembly including core and cut in insulator. | — | — | — | 1,26,350 | |
| — | Breakup | for details. | — | ||
| Breaking of PCC/foundation | — | — | — | 64,800 | |
| — | Breakup | for details. | — | ||
| Dismantling & removal of guy rod assembly. | — | — | — | 5,336 | |
| — | Breakup | for details. | — | ||
| Dismantling & removal of regulating equipment (ATD) | — | — | — | 21,400 | |
| — | Breakup | for details. | — | ||
| Dismantling & removal of Mast, portal; TTC & other small part steel | — | — | — | 32,424 | |
| — | Breakup | for details. | — | ||
| Dismantling & removal of isolator complete | — | — | — | 3,982 | |
| — | Breakup | for details. | — | ||
| Dismantling of existing OHE | — | — | — | 23,076 | |
| — | Breakup | for details. | — | ||
| Erection under Power Block | — | — | — | 1,65,762 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
1-GCCwithACS10final.pdf
ATTACHMENT
T-12ICDSBIbridgeworkR-3.pdf Tender Document
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .