| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAdmitted-Finance | ₹27.1 L | L1 | Admitted-Finance |
| 2 | L2₹29.3 LAdmitted-Finance | ₹29.3 L | L2 | Admitted-Finance |
| 3 | L3₹30.0 LAdmitted-Finance | ₹30.0 L | L3 | Admitted-Finance |
| 4 | L4₹38.9 LAdmitted-Finance FATEHPORA POSH BAGH BARAMULLA JAMMU KASHMIR 193101 UDYAM JK 03 0027297 | BARAMULLA | JAMMU AND KASHMIR | 193101 | ₹38.9 L | L4 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | Rejected-Technical Invalid/ Insufficient work experience |
| Sl No | Description | Qty | Unit | HARMUKH INFRASTRUCTURE PRIVATE LIMITED L2 | AL-AWAAL BUILDERS AND DESIGN PVT LTD L3 | ALIF INFRAPROJECTS PVT LTD L4 | TESLA ENGINEERING WORKS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply, Carriage upto site (including Loading/Unloading),Testing and Erection of Steel Tubular Pole, 13 Mtr. Long Pole (ST-410 SP 69) with planting depth of 1/6 th of the height of the pole, (13 mtr. Long ) as per approved drawings/standards | 55 | No. | 34,000 ₹18.7 L | 40,000 ₹22 L | 35,000 ₹19.3 L | 35,000 ₹19.3 L |
| 2.00 | Supply, Carriage upto site (including Loading/Unloading), Laying ,Stringing, Tensioning & Binding of ACSR Conductor, (50 Sqmm ACSR Conductor-Rabbit) as per approved drawings/standards | 4 | Km | 60,000 ₹2.4 L | 25,000 ₹1 L | 60,000 ₹2.4 L | 55,000 ₹2.2 L |
| 3.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of GI Channel/ GI V X Arms/Extension Top/Angle Iron/Flat/Belting Angle/Anti Skidding Clamps/Fuse plates of various sizes including clamps as per approved drawings/standards | 2,000 | Kg. | 130 ₹2.6 L | 140 ₹2.8 L | 200 ₹4 L | 120 ₹2.4 L |
| 4.00 | Supply, Carriage upto site (including Loading/Unloading),Testing, Fixing & Commissioning of33 kV Lightening Arrestors (33 kV, 10kA, Station class, ZnO, Polymer) gap less (1 No. per Φ) (1 Set=03 Pieces) | 1 | Set | 21,000 ₹21,000 | 20,000 ₹20,000 | 20,000 ₹20,000 | 10,000 ₹10,000 |
| 5.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of PG/T Clamps suitable for 200 Sqmm ACSR as per approved drawings/standards | 24 | No. | 200 ₹4,800 | 100 ₹2,400 | 1,000 ₹24,000 | 340 ₹8,160 |
| 6.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm (reputed make) as per approved drawings/standards | 180 | No. | 190 ₹34,200 | 150 ₹27,000 | 950 ₹1.7 L | 190 ₹34,200 |
| 7.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting (reputed make) as per approved drawings/standards | 18 | No. | 500 ₹9,000 | 300 ₹5,400 | 1,500 ₹27,000 | 400 ₹7,200 |
| 8.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of Galvinized Nuts and Bolts as per approved drawings/standards | 50 | Kg. | 130 ₹6,500 | 150 ₹7,500 | 160 ₹8,000 | 130 ₹6,500 |
| 9.00 | Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of Spike Earthing Rod 20mm 2,5 Mtr long with GI strip (25x3)mm as per approved drawings/standards | 55 | No. | 999 ₹54,945 | 1,000 ₹55,000 | 1,500 ₹82,500 | 400 ₹22,000 |
| 10.00 | Supply & Laying of Cement bottoming for 13 Mtr ST Pole in 1:2:4 mix as per Standards 0.78 cum/pole including the Loading/Carriage/Unloading of required material. | 55 | No | 4,000 ₹2.2 L | 4,000 ₹2.2 L | 6,000 ₹3.3 L | 2,000 ₹1.1 L |
Tender Value
₹33.0 L
EMD Value
₹66,060
Closing Date
17 Mar 2026, 4:00 pmClosed
Executive Engineer STD Sopore
Sub Transmission Division Sopore Amargarh
Erection of 13 Mt Poles on 33 KV Wanigam Tapline and Shifting of Existing 11 KV Wanigam Feeder on Proposed 13 Mtr Poles
2026_PDD_302248_2
STDS/ 32 of 2025-26
Open Tender
Electrical Works
90 days
Pattan
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,005
Yes
Executive Engineer STD Sopore
₹66,060
Yes
8 Apr 2026
7 Mar 2026
18 Mar 2026
7 Mar 2026
17 Mar 2026
7 Mar 2026
Supply, Carriage upto site (including Loading/Unloading),Testing and Erection of Steel Tubular Pole, 13 Mtr. Long Pole (ST-410 SP 69) with planting depth of 1/6 th of the height of the pole, (13 mtr. Long ) as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading), Laying ,Stringing, Tensioning & Binding of ACSR Conductor, (50 Sqmm ACSR Conductor-Rabbit) as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of GI Channel/ GI V X Arms/Extension Top/Angle Iron/Flat/Belting Angle/Anti Skidding Clamps/Fuse plates of various sizes including clamps as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing, Fixing & Commissioning of33 kV Lightening Arrestors (33 kV, 10kA, Station class, ZnO, Polymer) gap less (1 No. per Φ) (1 Set=03 Pieces)
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of PG/T Clamps suitable for 200 Sqmm ACSR as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm (reputed make) as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting (reputed make) as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of Galvinized Nuts and Bolts as per approved drawings/standards
Supply, Carriage upto site (including Loading/Unloading),Testing & Fixing of Spike Earthing Rod 20mm 2,5 Mtr long with GI strip (25x3)mm as per approved drawings/standards
Supply & Laying of Cement bottoming for 13 Mtr ST Pole in 1:2:4 mix as per Standards 0.78 cum/pole including the Loading/Carriage/Unloading of required material.
Supply,Testing,Loading,Carriage,Unloading and fixing of Danger Plates with Clamps as per approved drawings/standards
Supply,Testing,Loading,Carriage,Unloading and fixing of Anti-Climbing Device with Clamps as per approved drawings/standards
Providing & Painting of Poles (13 Mtr Long) with one coat of Red Oxide and two coats of aluminium paint and as per approved drawings/standards
Shifting of existing ACSR of 11 KV Wanigam Feeder on new 13/11 MT ST Poles
Dismantalling of Existing ST Poles 8/9/11 Mtr along with allied material (Cross Arms/Insulators) and subsequent carriage of dismantled material to divsional Stores Sopore
Dismantalling of Existing ACSR and subsequent carriage of dismantled material to divisional Stores Sopore
Engagement of skilled labour along with necessary machinery(power saw) for cutting and clearance of tree branches interfering with electrical lines (whereever required), including proper disposal/stacking of cut material, complete with all tools, tackles, machinery, and safety equipment, as per directions of the Engineer-in-Charge
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
techsummary_992349.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.41 MB
Retender.pdf
Additional Documents • 0.16 MB
BOQ_992349.xls
BOQ • 0.30 MB
SBD32.pdf
Tender Documents • 1.69 MB
ilovepdf_merged_compressed.pdf
Additional Documents • 8.95 MB
Download all tender documents and submit your bid