| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC THIRIYA NIZAWAT KHAN JAMAMASZID WARD NO 07 BAREILLY 2430021 UP | BAREILLY | UTTAR PRADESH | 243002 | L1 | Accepted-AOC Being reasonable | |
| 2 | L2₹21.8 L+₹39,410 (1.84%)Rejected-Finance VIKRAM COACHING GALI SUDAMA NAGARI MADI NATH BAREILLY 243001 | BAREILLY | UTTAR PRADESH | 243001 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹26.8 L+₹5.4 L (25.3%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹28.4 L+₹7.1 L (33.1%)Rejected-Finance 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹30.0 L+₹8.6 L (40.2%)Rejected-Finance 232 1 D SHIVLOK KANKARKHERA DISTT MEERUT UP PIN 250001 | MEERUT | MEERUT | UP | 250001 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
11 Jun 2024, 6:00 pmClosed
Lt Col Shilpam Bharali
Garrison Engineer (AF) Military Engineer Services, Bareilly 243002 (UP)
8806 MISCELLANEOUS REPAIR, REPLACEMENT OF UNSERVICEABLE, BURNT LT CABLES ALONG WITH SPARE PARTS OF LT PANELS WITH ACCESSORIES AT AF STATION, BAREILLY
2024_MES_654382_1
8806/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bareilly
Class D
Category b(i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (AF) Bareilly
₹70,000
Yes
1 Jul 2024
16 May 2024
13 Jun 2024
16 May 2024
11 Jun 2024
30 May 2024
Amount
Taking out of existing LT UG cable of size 3½/4 core, 25 to 240sq.mm including taking out protection bricks complete all as specified and directed. [Note: Earth work & excavation will be measured and paid separately].
Supply, lay, connect, test and commissioning of LT XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade of size 4 core 25 sq.mm complete all as specified and directed. [Note: (i) Necessary test results like continuity test, megger tests shall be submitted to Engineer-in-Charge before the cable is laid. (ii) Excavation & earth work will be measured and paid separately].
All as per Item No. 2 herein before but cable of size 4 core 10 sq.mm
All as per Item No. 2 herein before but cable of size 4 core 16 sq.mm
All as per Item No. 2 herein before but cable of size 3½ core 35 sq.mm
All as per Item No. 2 herein before but cable of size 3½ core 50 sq.mm
All as per Item No. 2 herein before but cable of size 3½ core 70 sq.mm
All as per Item No. 2 herein before but cable of size 3½ core 95 sq.mm
All as per Item No. 2 herein before but cable of size 3½ core 120 sq.mm
All as per Item No. 2 herein before but cable of size 3½ core 150 sq.mm
All as per Item No. 2 herein before but cable of size 3½ core 185 sq.mm
All as per Item No. 2 herein before but cable of size 3½ core 240 sq.mm
All as per Item No. 2 herein before but cable of size 3½ core 300 sq.mm
M&L for LT cable straight through jointing kit heat shrinkable type suitable for XLPE/ PVC insulated cable of size 4C x 10-16sq.mm complete including testing the cable joint for healthiness, cutting & removing unserviceable joint, preparation of both ends of cable to be joined with necessary stretching, aligning, making joint all as specified and as required at site.
All as per Item No. 14 herein before but for cable of size 3½/ 4 core 25 to 50 sq.mm
All as per Item No. 14 herein before but for cable of size 3½ core 70 to 150 sq.mm
All as per Item No. 14 herein before but for cable of size 3½ core 185 to 240 sq.mm
Horizontal Boring under hard standing/ pavements or roads manually using suitable auger for insertion of GI pipes up to 100mm bore and making good the disturbed surface complete all as specified and as directed. [Note: GI pipe will be measured and paid separately]
S&F GI tubes 50mm bore dia light grade with all fittings laid in trenches or inserting in horizontal boring complete all as specified and as directed.
S&F GI tubes 80mm bore dia light grade with all fittings laid in trenches or inserting in horizontal boring complete all as specified and as directed.
S&F GI tubes 100mm bore dia light grade with all fittings laid in trenches or inserting in horizontal boring complete all as specified and as directed.
S&F in repairs pin type porcelain, vitreous, white/ brown/ green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and as directed.
S&F in repairs Shackle type vitreous porcelain, white/ brown/ green insulator including galvanized mild steel straps of 31x3mm section, washers, insulator bolts of 12mm dia, washers and nuts for working pressure 1100 Volts grade, 75mm height, 90mm maximum dia all as specified and as directed
Re-stretching of existing loose overhead LT ACSR conductor wire along with GI wire (4/5 wires) for sagging within the permissible limit, including winding/ rewinding/ joining with aluminium winding wire of not less than 2 sq.mm size in case of breakage of conductor, complete all as specified and as directed by the Engineer-in-Charge. [Note: Nothing extra is admissible on account of jointing material and labour in case the conductor breaks during stretching].
Disconnecting and taking down aluminum conductor steel reinforcement (ACSR) of any size from existing over head line all as directed.
M&L for Aluminium conductor steel reinforced (ACSR) as in over head conductor fixed to insulators mounted on LT poles with aluminium tapes for binding complete all as specified & as directed Note:- (i) Weight of ACSR conductors shall be determined by measuring the horizontal distance between center of two adjacent poles and compounding the weight of conductors of size and length provided and 3% extra added for sag, jointing, jumpers etc. (ii) The weight of aluminium tapes shall not be added in the weight of the conductors for payment purpose.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete including dismantling existing rusted sections all as directed.
S&F PVC line separator for LT overhead lines complete all as specified and as directed.
S&F in repairs MCCB 4 Pole, 400 Amps, 36 KA, 415 V with adjustable magnetic setting, with 02 Nos spreader links for both incoming side and out going side complete all as specified and directed.
S&F in repairs MCCB 4 Pole, 320 Amps, 36 KA, 415 V with adjustable magnetic setting, with 02 Nos spreader links for both incoming side and out going side complete all as specified and directed.
S&F in repairs MCCB 4 Pole, 250 Amps, 25 KA, 415 V with adjustable magnetic setting, with 02 Nos spreader links for both incoming side and out going side complete all as specified and directed.
S&F in repairs MCCB 4 Pole, 200 Amps, 25 KA, 415 V with adjustable magnetic setting, with 02 Nos spreader links for both incoming side and out going side complete all as specified and directed.
S&F in repairs MCCB 4 Pole, 160 Amps, 25 KA, 415 V with adjustable magnetic setting, with 02 Nos spreader links for both incoming side and out going side complete all as specified and directed.
S&F in repairs MCCB 4 Pole, 125 Amps, 25 KA, 415 V with adjustable magnetic setting, with 02 Nos spreader links for both incoming side and out going side complete all as specified and directed.
S&F in repairs MCCB 4 Pole, 100 Amps, 25 KA, 415 V with adjustable magnetic setting, with 02 Nos spreader links for both incoming side and out going side complete all as specified and directed.
S&F in repairs MCCB 4 Pole, 63 Amps, 16 KA, 415 V with adjustable magnetic setting, with 02 Nos spreader links for both incoming side and out going side complete all as specified and directed.
Supply & erecting in true vertical position, steel tubular swaged pole 410-SP-31, 9 meter long complete with mild steel base plate, pole cap, finial taper plug, bolts, nuts, washers etc. including painting the exposed outer surfaces with two coats of aluminium paint over a coat of red oxide primer including 3 Nos of bands/straps painted with signal red and white colour (300mm each) in alternate layers from plinth block, marking of pole number with black synthetic enamel paint 2.5 cm height including applying one coat of black bituminous paint on portion embedded in concrete foundation complete all as specified including taking down existing unserviceable pole after disconnecting and demolition of PCC coping, foundation etc. all as directed. [Note: Earth work and excavation, PCC foundation & coping shall be measured and paid separately]
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized earth strip of 32X6mm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel and connected from earth plate electrode to main switch board/ earthing test point including watering arrangement with PCC 1:3:6 type C1 chamber, MS funnel, wire gauge, 50mm thick precast RCC cover in Type B1, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n.exc 50m, charcoal and salt complete all as shown in electrical plate No. 3 of SSR Part-I 2009 and connected to earthing test point all as specified or indicated and testing on completion
S&F in repairs Off Load changeover switch 415 V, 4 pole, 400 Amps capacity with sheet steel enclosure complete all as specified and as directed.
S&F in repairs Off Load changeover switch 415 V, 4 pole, 250 Amps capacity with sheet steel enclosure complete all as specified and as directed.
M&L for Preparation of surfaces of steel electric poles/ masts of height up to 7.5m (exposed) by scraping with emery paper and making free from rust, dust and any foreign material and applying one coat of aluminium paint including lettering on poles such as Pole No and source point of electric supply with white enamel paint on black back ground, zebra painting up to 1.2 m height from ground level with two coats of synthetic enamel paint in 30cm height of alternate bands all as specified and as directed.
M&L for carrying out repairs to existing LT panels by cutting, welding of hanging doors on all sides, replacement of hinges as required, repairs/ making good of PCC pedestals, painting with two coats of synthetic enamel paint including labeling of panel complete all as specified and directed.
Disconnecting and taking down existing LT air circuit breakers of capacities ranging 400 Amps to 1250 Amps from panels, carrying out servicing comprising checking/ repair of mechanical system of ACB, checking/ repair of the manual closing/ tripping of breaker, lubricating the moving parts and refixing the same, re-orientation and connecting up complete all as directed.
M&L for plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete all as specified and as directed.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping of pole all as directed including use & waste of necessary form work all as specified and as directed.
Excavating manually in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n. exc. 10sq.m. on plan and n. exc. 1.5m in depth and getting out in soft/ loose soil.
Supply and spread river sand as in cushioning for UG cable all as specified in clause 19.75 of SSR Part I. [Note: Punned down thickness shall be considered for payment]
Supply and laying well burnt sub class ‘B’ bricks (old size brick) laid in trenches above sand cushioning for cable protection complete all as specified and as directed.
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in any type of soil all as specified and as directed.
Removing excavated materials to a distance not exc. 50m and depositing where directed at a level n.exc 1.50m above the starting point all as specified and as directed.
Deduct: Amount of Schedule of Credit b/f from Sl. Page No. 16 of tender document i.e. Rs. 1,30,060/-
M/s. S.S. Refrigeration, Bareilly
M/S BABA ENTERPRISES
Shikha Enterprises
Shikhar ji Enterprises
Vishal Traders
M/S HINA ELECTRICALS
M/s Agarwal Builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .