Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST REASONABLE BID | |
| 2 | L2₹30.1 L+₹2.1 L (7.52%)Rejected-Finance 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L2 | Rejected-Finance NOT LOWEST |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
20 Mar 2025, 6:00 pmClosed
CWE ARMY JODHPUR
CWE ARMY MULTAN LINE ARMY AREA JODHPUR-342010
REPAIR TO CEILING FAN, EXHAUST FAN, WALL MOUNTING FAN, PEDESTAL FAN AND AIR CIRCULATING FAN AND DESERT COOLERS AT ARMY AREA JODHPUR UNDER GE (ARMY) NO.01
2025_MES_697969_1
82425/111/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (ARMY) NO. 01 JODHPUR
₹60,000
Yes
30 Apr 2025
14 Feb 2025
27 Mar 2025
14 Feb 2025
20 Mar 2025
1 Mar 2025
15 Feb 2025 - 28 Feb 2025
Amount
Material and labour for (in existing location and position) taking out and refixing after repairs, including rewinding of Desert Cooler fan motor of, 3 speed,1400 RPM of capacity 1/5 HP with super enameled copper winding wire of appropriate size ( as per existing ) incl Bush/Shaft/Ball bearing as per existing model complete all as specified and directed by Engineer-in Charge.
Supply and replacement of oil filled capacitor 4.00 MFD for desert cooler fan motor complete all as specified and directed by Engineer-in Charge.
Material and labour for replacement of bottom tank and top ( in existing location and position) of approx size - 750 X 750 X 200 mm ( as per existing ) for Desert Cooler of 18 gauge PGI sheet with and including two coats of synthetic enamel painting over one coat of red oxide primer on the new surfaces to match with existing surface outside and inside surface with approved quality paint including leakage testing complete all as specified and directed by Engineer-in Charge.
Material and labour for ( in existing location and position ) replacement of front grill ( as per existing )( horizontal and vertical members moveable) of the Desert Cooler of 20 gauge PGI sheet with Name plate complete all as specified and directed by Engineer-in Charge.
Material and labour for replacement of side supporting columns to be fabricated out of 18 gauge PGI sheet of size 80x80x800 mm with and including necessary nut, bolts etc. complete all as specified and directed by Engineer-in Charge.
Material and labour for replacement of side/rear panel of 20 gauge PGI Sheet with suitable handles with and including two coats of synthetic enamel paint over one coat of red oxide primer to match with the existing desert cooler complete all as specified and directed by Engineer-in Charge.
Material and labour for painting to old steel surfaces of Desert cooler capacity up to 5000 Cft with one coat of synthetic enamel spray paint hammer tone paint of approved colour over one coat of red oxide primer on external surface and one coat of anti corrosive black paint inside the Body tank and side grills over a coat of red oxide primer complete including scraping/rubbing with wire brush on old surface of Desert cooler and writing of MES No etc complete at site or at E/M store yard complete all as specified and directed by Engineer-in Charge.
Material and labour for replacement of Desert Cooler fan motor capacity 1/5 HP three speed, 1400 RPM single phase with aluminium fan blade, bracket supporting stand complete all as specified and directed by Engineer-in Charge.
Material and labour for replacement of submersible pump of discharge head 2.5 Mtr 220-240 Volts AC Supply single phase 40 watt complete all as specified and directed by Engineer-in Charge.
Material and labour for replacement of Wood wool pad for Desert Cooler of size 500 x 550 x30 mm (set of three pads) superior quality including binding properly with GI wire of 16 SWG complete all as specified and directed by Engineer-in Charge.
Material and labour for replacement of MS weld wire mesh having apparture size 25 mm and fitted in side grills/rear complete all as specified and directed by Engineer-in Charge.
Material and labour for replacement of Wood wool pad Heavy duty for Desert Cooler of suitable size (set of three pads) superior quality including binding properly with GI wire of 16 SWG with grill complete all as specified and directed by Engineer-in Charge.
Material and labour for replacement of PVC insulated and PVC sheathed cable copper conductor 3 core 1.0 Sqmm cross sectional area superior quality complete all as specified and directed by Engineer-in Charge.
Material and labour for replacement of PVC water distribution cup of one inlet and 3 outlets fixed with MS nuts and bolts complete all as specified and directed by Engineer-in Charge.
Material and labour for replacement of PVC elbow suitable for desert cooler (as per sample) complete all as specified and directed by Engineer-in Charge.
Material and labour for replacement of PVC pipe 15 mm dia heavy duty for Desert Cooler Pump complete all as specified and directed by Engineer-in Charge.
Material and labour for painting to desert cooler stand with two coats of synthetic enameled paint of approved colour over a coat of red oxide primer including preparation of old surfaces complete all as specified and directed by Engineer-in Charge.
Material and labour for replacement of motor fixing ring (not less than 25 mm width ) for desert cooler eight screw / clip type(asper sample) complete all as specified and directed by Engineer-in Charge.
M&L for taking down desert cooler installed at ground floor safely , including cleaning inside , outside , motor oilng sevicing and pump servicing including putting up in same location and position complete all as specified and directed by Engineer-in Charge. NOTE: Any replacement of spare shall be measured and paid separately under respective item of schedule 'A'.
M&L for taking down desert cooler installed at first floor safely , including cleaning inside , outside , motor oilng sevicing and pump servicing including putting up in same location and position complete all as specified and directed by Engineer-in Charge. NOTE: Any replacement of spare shall be measured and paid separately under respective item of schedule 'A'.
M&L for taking down desert cooler installed at second floor safely , including cleaning inside , outside , motor oilng sevicing and pump servicing including putting up in same location and position complete all as specified and directed by Engineer-in Charge. NOTE: Any replacement of spare shall be measured and paid separately under respective item of schedule 'A'.
M & L for stand flush to wall for desert cooler fabricated out of MS angle iron 40 x 40 x 6 mm , 1.2 meter long bend to shape as top size 600 x 600 mm duly welded with two members to tie vertical support , including painting two coats of synthetic enamelled paint over a coat of red oxide primer including M&L for steel rack bolt / fastner 100 mm long 12 mm dia - 4 Nos for fixing stand complete all as specified and directed by Engineer-in Charge.
Supply and fix in existing location and position PTMT stop cock 15 mm dia high pressure screwed for iron pipe complete all as specified and directed by Engineer-in Charge.
Supply and fix in existing location and position PTMT Ball valves 15 mm dia high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and directed by Engineer-in Charge.
M & L for wiring for circuit / sub main wiring alongwith earth wire with the following sizes of FR LSH PVC insulated , multistranded copper conductor cable ,( 2 X 1.5 Sq mm + 1X 1.5 Sqmm ), single core drawn in and including PVC casing capping 25 mm width , to be fixed on surface/ ceiling complete all as specified and directed by Engineer-in Charge.
Supply and replacement of 3 Pin Plug Top 06Amps ISI Marked 230 Volts complete all as specified and directed by Engineer-in Charge.
Material and labour for replacement of PVC Connection pipe ISI Marked 300mm long heavy duty complete all as specified and directed by Engineer-in Charge.
Material and labour for replacement of PVC stop cock ISI Marked heavy duty complete all as specified and directed by Engineer-in Charge.
Supply and replace PVC moulded box of switch socket combination of cap - 6 Amp complete all as specified and directed by Engineer-in Charge.
M&L for dismantling and removing old burnt out copper winding wire of ceiling fans of size - 1200 mm (48” ) sweep and rewinding with New super enameled copper winding wire of existing gauge as per old copper winding pattern and design to give same performance as per original fan providing insulating media , varnishing (Golden), Cleaning, Oiling, Greasing etc, including replacement of u/s ball bearing/ bush & model and refixing all the parts complete all as specified and directed by Engineer-in Charge.
All as per item No 31.00 here in before but Exhaust Fans of size 9" ( 225 mm ) Sweep – ditto- complete all as specified and directed by Engineer-in Charge.
All as per item No 31.00 here in before but Exhaust Fans of size 12" ( 300 mm ) Sweep – ditto- complete all as specified and directed by Engineer-in Charge.
All as per item No 31.00 here in before but Exhaust Fans of size 15”/16” ( 375 /400 mm ) Sweep complete all as specified and directed by Engineer-in Charge.
All as per Item No 31.00 above but Exhaust Fans of Size 18” ( 450 mm ) Sweep –ditto- complete all as specified and directed by Engineer-in Charge.
All as per item No. 31.00 here in before , but for WALL MOUNTED fan alongwith replacement of osscilating mechanism and regulator complete suitable for wall mounting fan and support hud assembly of size - 16"/18" complete all as specified and directed by Engineer-in Charge.
All as per item No.31.00 here inabove , but for heavy duty AIR CIRCULATING/Pedestal fan of size - 600 mm ( 24" ) , 1400 RPM, including replacement of bush / bearing of approved, alongwith replacement of osscilating mechanism and regulator and refixing at location in unit line A/A complete all as specified and directed by Engineer-in Charge. NOTE:-(i) For Ser Item No 31.00 to 37.00. The super enamelled winding wire is to provided of appropriate gauge as approved by EIC. (ii) Any un-serviceable part required for replacement shall be measured and paid separately under respective item of schule 'A'..
Hanging only ceiling fan repaired or new any size and connecting up to the ceiling rose including taking down old u/s fan complete all as specified and directed by Engineer-in Charge. (Note:- 1. if ceiling fan fel down any cause contractor will responsibal for this accident
Fixing only exhaust fan of any size at MD/OTM Accn in unit lines of Army Area and connecting up to the ceiling rose including taking down old u/s fan complete all as specified and directed by Engineer-in Charge.
S&F capacitor of 2.5 MFD oil filled insulated with aluminium body after removing unserviceable condenser complete all as specified and directed by Engineer-in Charge.
All as per Item No 40.0 above but of 4.00 MFD complete all as specified and directed by Engineer-in Charge.
Supply and replacement of ' Ú' clamp with rubber reel of standard quality including nut/bolt , lock nut and pin suitable for ceiling fans (any type/sweep) complete all as specified and directed by Engineer-in Charge.
Supply and replacement of PVC canopy upper/lower side of standard/ good quality including bolt with nut , lock nut and pin suitable for ceiling fans (any type/ any sweep) complete all as specified and directed by Engineer-in Charge.
Supply and replacement of down rod 60 cm long of 15 mm dia " heavy duty " thread type GI pipe complete with rubber bush, centre bolt , nut , lock nut ,"U" clamp suitable for thread ends connection with cotter pin complete all as specified and directed by Engineer-in Charge.
Supply and replacement of down rod 60 cm long of 12 mm dia of high density mild steee including drilling hole for split pin complete all as specified and directed by Engineer-in Charge.
Supply and replacement of down rod 90 cm long of 12 mm dia of high density mild steee including drilling hole for split pin complete all as specified and directed by Engineer-in Charge.
Supply and replacement of down rod 30 cm long of 12 mm dia of high density mild steee including drilling hole for split pin complete all as specified and directed by Engineer-in Charge.
S&F MS U-type Hook hanger with M10x 75mm Fastners(double fastners) complete with nuts, bolts and washers for hanging Ceiling fans complete all as specified and directed by Engineer-in Charge.
S&F GI pipe medium grade 40mm dia for hanging Ceiling fan any size including cutting as per site requirement and grouting with cement concrete in both ends on existing brick/stone wall complete all as specified and directed by Engineer-in Charge.
M&L for hole in existing brick / stone wall for fixing exhaust/ ventilation fan complete all as specified and directed by Engineer-in Charge.
Supply and replacement of fan blade as per existing including fixing screws suitable for ceiling fans 1200 mm sweep complete all as specified and directed by Engineer-in Charge.
Supply and replacement of fan blade as per existing including fixing screws suitable up to 300 mm sweep exhaust fans complete all as specified and directed by Engineer-in Charge.
Supply and replacement of fan blade as per existing including fixing screws suitable for exhaust fans 375/400 mm sweep complete all as specified and directed by Engineer-in Charge.
Supply and replacement of fan blade as per existing including fixing screws suitable for exhaust fans 450 mm sweep complete all as specified and directed by Engineer-in Charge.
Supply and replacement of bracket with frame as per existing including fixing screws suitable up to300 mm sweep exhaust fans complete all as specified and directed by Engineer-in Charge.
Supply and replacement of bracket with frame as per existing including fixing screws suitable for exhaust fans 375/400 mm sweep complete all as specified and directed by Engineer-in Charge.
Supply and replacement of bracket with frame as per existing including fixing screws suitable for exhaust fans 450 mm sweep complete all as specified and directed by Engineer-in Charge.
M & L for painting of ceiling fan size - 1200 mm sweep complete with down rod and blades , cleaning , removing dirt / dust , scrapping out old paint , applying putty and painting with synthetic enamel paint first quality of approved including writing MES No. in figure & words 25 mm wide with synthetic enamel paint of black colour on ceiling fans complete all as specified and directed by Engineer-in Charge.
All as per item No 58.00 here in before but Exhaust Fans off any size/ Sweep – ditto- complete all as specified and directed by Engineer-in Charge.
M & L for pvc stand for capacitor including connection etc. complete all as specified and directed by Engineer-in Charge.
M&L for louver of MS sheet 3 mm thick for e/fan off sizes complete all as specified complete all as specified and directed by Engineer-in Charge.
Supply and fixing connecting PVC insulated copper conductor multistranded,unsheated cable of size 23/0.0076 up to the ceiling rose,lenth of cable 0.60 RM for each job complete all as specified and directed by Engineer-in Charge.
Note for all items :- MES No. of cooler and fans with exact location for which repair work is carried out shall to be mentioned in MB while recording the measurement.
M/s Shiv Builder and Suppliers (BID ID -3263376)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .