Loading…
Loading…
Tender Value
₹85.7 L
EMD Value
₹1.7 L
Closing Date
13 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
W5
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where: V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case the balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of Part I of GCC, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following c ategories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited:(i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or(ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or(iii) One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Definition of Similar work means :-"Any Signaling work involving Outdoor work and/or addition and/or alteration in existing Indoor signaling system. OR Any CLS or RI or EI or TPWS or IBS or ABS or BPAC work involving and/or Outdoor. Similar work to include Indoor if the tendered work involves addition and/or alteration in existing Indoor signaling system and Outdoor if the tendered work involves Outdoor work OR Any such work involving activities as given in the name of the tendered work.)."
15 conditions · 4 needing a document upload
As per "CHECK LIST" document attached.
Following documents dully filled & signed to be uploaded. Standard formats are provided in (Annexure provided with tender document. Tenders are required for furnish details in thhese format).
"Tender Form" As per 'TENDER FORM" (Ref Standard format provided in Annexures).
Deviation Statement:- The tender shall submit a statement indicating any deviations against any clause of this tender including all the technical specication concerned to this work, duly signed and stamped on each page. If there are no deviation whatsoever, a Nil deviation statement should be submitted. (Ref Standard format provided in Annexures) In case firm has not submitted deviation or blank deviation statement it will be treated as NIL deviation.
List of works completed: list of works completed in the last seven financial years giving description of work, organization for whom executed, approximate value of contract at the time of award, date of award and date of schedule completion of work. Date of actual start, actual completion and final value of contract should also be given. (Ref Standard format provided in Annexures).
List of works on hand:- List of works on hand indicating description of work, contract value, and approximate value of balance, work yet to be done and date of award (Ref Standard format provided in Annexures).
Details of payment through NEFT/RTGS. (Ref Standard format provided in Annexures).
List of Personnel, organization:- List of Personnel, organization/technical staff available on hand and proposed to be engaged for the subject work, with their designation and experience.
Document for technical skill:- Documentary evidence necessary to establish that they possess the requisite skill, technical expertise, technical and skilled manpower and necessary equipment's to execute complete work covered in the schedule with stipulated specification/details.
Special instruction regarding payment of Bid Security: Excerpt of GCC April -2022 read as (i)Any firm recognized by Department of Industrial Policy and Promotion (DIPP) as 'Startups' shall be exempted from payment of Bid Security. (ii)Labour Cooperative Societies shall deposit only 50% of above Bid Security. (Refer para 7.0 of CHAPTER-II {INSTRUCTIONS TO TENDERERS} of Tender document) for clarification see GCC April-2022. Mandatory submission of relvent document if applicable.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Part supply of signaling material, installation, testing & commissioning in connection with Gandhidham Jn Goods shed- Extension of goods line no. 5 & TY line for full length for loading and unloading goods of Ahmedabad Division.
DRM-SnT-ADI-Sig24of25-26
DRM-SnT-ADI-Sig24of25-26
Open
Works - General
12 Months
Ahmadabad, Gujarat
₹0
₹1.7 L
13 Mar 2026
13 Feb 2026
27 Feb 2026
134 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 22,52,305.76 | ||
| — | 9.00 | — | — | ||
| Universal AC ECR of Q series, type "QECX61" suitable for AC LED all signal aspect, Front & back contact Metal to Carbon type complete with plug board retaining clip & connectors conforming to Spec STS/E/Relays/AC Lit LED Signal/09/2002, BRS: 941A, IRS S-34 and S-23 (as applicable) | — | — | — | 52,850.88 | |
| — | 50.00 | — | — | ||
| Miniature, Plug-in Type, DC Neutral Line AC Immunized Relay, Style QNA1, 24 V DC, 8F-8B/12F-4BContact, Code ABDGH/ABDFH Spec: BRS: 931A; IRS S 34; IRS S 23; IRS S 60-78. | — | — | — | 2,66,039 | |
| — | 3.00 | — | — | ||
| Miniature, Plug-in Type, DC Neutral Line Magnetically Latched Relay, Style QL1, 24 V DC, 11F-4B Contact, Code ABDEG Spec: BRS:935A ; IRSS 34 ; IRS S 23. | — | — | — | 22,710.57 | |
| — | 10.00 | — | — | ||
| Plug in Type, Tractive Armature, AC Immunized, DC Biased Contactor Relay, Style QBCA1,2HF-4B Contact,24 V DC, Code BCEJK Spec:BRS:943 ; IRS S 34 ; IRS S 23 ;IRSS 60-78. | — | — | — | 64,370 | |
| — | 2.00 | — | — | ||
| Key Lock Relay working on 24V DC, AC immunize with different ward combinations (Three ward plates to be supplied with each relay). Key ward shall be specified by engineer incharge as per requirement. | — | — | — | 16,469.18 | |
| — | 4.00 | — | — | ||
| Miniature, Plug in Type, M to C,DC Neutral ,Track relay, ACI, Style QTA2, 9 Ohm, 2F- 1B contact, Code - FGHKX Spec : BRS :939-A & 966 (Appx-F2) & IRS : S-23, S-23,S-34 & 60. | — | — | — | 23,293.84 | |
| — | 4.00 | — | — | ||
| Miniature, Plug in Type, DC Neutral ,Line Relay QSPA1, 24V DC, Slow to Pick up AC Immunized, 12F-4B/8F-4B Contact, Code ABDEJ Spec:BRS:933A ; IRS S 34 ; IRS S 23;IRS S 60-78. | — | — | — | 19,676 | |
| — | 2.00 | — | — | ||
| Desk type Electronic Mageneto Telephone as per spec No IRS/TC-79/2000 or with latest amendments. | — | — | — | 7,246.2 | |
| — | 500.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments Disconnect Terminal Block, Screw less type, 4- wire front entry (Two in-put & Two out-put) The color will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3). as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. Note: Make to be approved by Railway before supply. | — | — | — | 30,525 | |
| — | 30.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments Supply of End plate 2.5mm/0.091 in thick as per site requirement. | — | — | — | 346.5 | |
| — | 30.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments Supply of End Stopper 10mm/0.0394 in width as per site requirement. | — | — | — | 339.9 | |
| — | 5.00 | — | — | ||
| Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement. | — | — | — | 593.4 | |
| — | 50.00 | — | — | ||
| Indicative type fuse base/holder with cap, suitable to G type of capacity 0.63 A - 3.0 A. (System, Rapid, Malnad or RBCO make or similar). | — | — | — | 3,000.5 | |
| — | 50.00 | — | — | ||
| D type fuse link non indicating type low voltage non detonating, capacity 2A/6A/10A as per specification IRS: S-80/92 or latest. Quantity break up of each type of fuse block will be specified by Engineer in-charge | — | — | — | 1,615 | |
| — | 18.00 | — | — | ||
| Cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4 & Spec No IRS S 75/2006 with the latest amendment. The fuse block shall be suitable for round- head type voltage fuses. This also includes the supply of equivalent no of ND type Fuses of 2A capacity as per specification IRS S-78/92. | — | — | — | 2,520.18 | |
| — | 1.00 | — | — | ||
| Fuse auto changeover system for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover unit comprises 32 nos. of external Non -Deteriorating Type or 'G' type fuses from 0.6Amp to 4Amp capacities which are used in signaling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. | — | — | — | 32,562.2 | |
| — | 1.00 | — | — | ||
| Fuse auto changeover system for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover unit comprise 24 nos. of external Non -Deteriorating Type or 'G' type fuses from 4Amp to 10Amp capacities which are used in signaling circuits. System shall have 6 cards with monitoring arrangement of 4 fuses in one card. | — | — | — | 54,218.46 | |
| — | 10.00 | — | — | ||
| SS Location box made of Spl. Grade SS 304 of size as per drg. No. DRM/SG/948 dt. 26.04.2011 (Signale app. Case). Manufactur's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. | — | — | — | 8,83,481.6 | |
| — | 5.00 | — | — | ||
| SS Location box made of Spl. Grade SS 304 of size as per drg. No. DRM/SG/945 dt. 03.03.2011 (Half app. Case). Manufactur's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply. | — | — | — | 3,30,275 | |
| — | 2000.00 | — | — | ||
| ARA Terminal blocks with links made of PBT Spec No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4. | — | — | — | 1,46,940 | |
| — | 25.00 | — | — | ||
| Supply of Double Walled Corrugated (DWC) pipe with associated collars etc.as per RDSO specification No. RDSO/SPN/204/2011 Ver. 1.0 and IS 14930 Part I & II or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size120mm outer dia,& 103.5mm inner dia. The required coupling arrangement should also be supplied. | — | — | — | 50,453.5 | |
| — | 50.00 | — | — | ||
| Supply of Medium class G.I. Pipes as per specification IS: 1239 (Pt.I)-1990 or latest 100mm dia. ( int. dia) 3.65 mm+/- 10% thick with coupling G.I. Pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. Pipes. Make- Tata, Jindal, Surya or Asian. | — | — | — | 31,701 | |
| — | 20.00 | — | — | ||
| — | 4.00 | — | — | ||
| — | — | — | 14,309.44 | ||
| — | 8.00 | — | — | ||
| — | 20.00 | — | — | ||
| — | 8.00 | — | — | ||
| — | 1.00 | — | — | ||
| — | 15.00 | — | — | ||
| — | 3.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
2FinalTNo24of2025-26.pdf
ATTACHMENT
TENDER ANNEXURES
ATTACHMENT
3TNo24of2025-26Annexure.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .