Loading…
Loading…
Tender ID
Tender Value
₹30 L
EMD Value
₹40,000
Closing Date
27 Jan 2026, 6:10 pmClosed
The E.E.(O&M), Sachin Division
Tenderization for ARC Work of Laying testing & commissioning of 11/22 KV UG XLPE CABLE with 11/22 KV Cable End Termination & ST joint Kits (to be Supplies by Agency) along with Erection of HT,LT & TC , Maintenance works under Sachin 2 Sdn and if required any other Sdn under jurisdiction of Sachin Division under ND and if Required Any other Scheme.
262991
SD/O&M/EXP/26/653 Date:07.01.2026
Open
Electrical Works
Works
Surat
6 documents required · 6 mandatory
₹1,180
Online Payment in DGVCL Sachin Division Account
₹40,000
8 Jan 2026
8 Jan 2026
8 Jan 2026
27 Jan 2026
8 Jan 2026
Name of Work :- Rate contract for erection of HT/LT line & T/C , UG work for various scheme work for SDN office
under Sachin Division Office.
ITEM CODE Details of Works Qty Unit Amount
HT TAPPING FROM THE EXISTING POLE
INCLUDING FIXING OF CROSS ARMS, CLAMPS
ANTI-CLIMBING DEVICES, DANGER BOARD,
INSULATORS ETC. COMPLETE AND PAINTING
OF FABRICATED MATERIALS AND NUMBERING
COMPLETE WITH COST OF PAINTS AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
ERECTION OF PSC POLES OF 8 *200 KG
INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH, FIXING OFCROSS ARMS,
TOP FITTING CLAMPS ANTI-CLIMBING
DEVICES, INSULATORS ETC. COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COST
OF PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUY SET AND
ERECTION OF STEEL POLES OF 9 TO
METERS INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH, FIXING OFCROSS ARMS,
TOP FITTING CLAMPS ANTI-CLIMBING
DEVICES, DANGER BOARD, INSULATORS ETC.
3 9926000003 COMPLETE AND PAINTING OF STEEL POLE, No. 1949
FABRICATED MATERIALS USED ON THE
POLEAND NUMBERING WITH COST OF PAINT
AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND
ERECTION OF STEEL POLE OF 13 METERS FOR
RAILWAY CROSSING ON BG/MG/NG LINE FOR
0.400/11/22KV OVERHEAD LINES I.E INCLUDING
EXCAVATION OF PIT & REFILLING OF EARTH,
FIXING CROSS ARMS, TOP FITTING
CLAMPS,ANTI-CLIMBING DEVICES DANGER
4 9926000004 BOARD, INSULATORS ETC. COMPLETE AND No. 2325
PAINTING OF STEEL POLES, FABRICATED
MATERIALS USED ON THE POLES AND
NUMBERING WITH COSTOF PAINT AS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SETS AND EARTHING.
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0064/01/2026 Approved Date: 08-01-2026
ERECTION OF DOUBLE POLE STRUCTURE OF
METERS 200 KG PSC POLES INCLUDING
EXCAVATION OF PITS & REFILLING OF
EARTHING, FIXING OF CHANNELS,
SUPPORTING ANGLES,CLAMPS, ANTI-
CLIMBING DEVICES DANGER
BOARDS,INSULATORS ETC.COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COST
OF PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUY SETS AND
EARTHING.(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE OF
TO 11 METERS.STEEL POLE INCLUDING
EXCAVATION OF PITS & REFILLING OFEARTH,
FIXING OF CHANNELS, SUPPORTING ANGLES,
CLAMPS,ANTI-CLIMBING DEVICES DANGER
BOARDS, INSULATORS ETC.COMPLETE &
PAINTING OF POLES,FABRICATED
MATERIALSUSED ON THE POLES AND
NUMBERING WITH COST OF PAINTSAS PER
STANDARD SPECIFICATION BUT EXCLUDING
ERECTION OF GUY SET AND EARTHING.
(WITHOUT AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE
WITH MOUNTING OF AB SWITCH, HG FUSES OF
8 MTRS 200 KG PSC POLES INCLUDING
EXCAVATION OF PITS AND REFILLING OF
EARTH,FIXING OF CHANNELS SUPPORTING
ANGLES, CLAMPS, ANTI-CLIMBING DEVICES,
7 9926000007 DANGER BOARDS, INSULATORS,DOFUSES No. 3179
ETC. COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLES
AND NUMBERING WITH COSTOF PAINT AS PER
STANDARD SPECIFICATION BUT
EXCLUDINGOF ERECTION OF GUY SET AND
EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE
WITH MOUNTING OF AB SWITCH,HG FUSES,
TO 11 METERS STEEL POLES INCLUDING
EXCAVATION OF PITS AND REFILLING OF
EARTH, FIXING OFCHANNEL, SUPPORTING
ANGLES, CLAMPS, ANTI-CLIMBING DEVICES
8 9926000008 DANGER BOARDS, INSULATORS, ETC. No. 4171
COMPLETE AND PAINTING OF POLES
FABRICATED MATERIALS USED ON THE POLES
AND NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND
EARTHING.(WITH AB SWITCH)
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0064/01/2026 Approved Date: 08-01-2026
ERECTION OF DOUBLE POLE STRUCTURES
WITH MOUNTING OFAB SWITCH, HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX. OF 8 METERS 200 KG PSC
POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROMSTORES TO SITE,
FIXING OF CHANNELS, SUPPORTING
9 9926000009 ANGLES,BRACINGS CROSS ARMS CLAMPS, No. 9074
ANTICLIMBING DEVICES DANGER BOARDS,
CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USEDON THE POLES
AND NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND
ERECTION OF DOUBLE POLE STRUCTURE
WITH MOUNTING OF AB SWITCH,HG FUSES
TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX 9 TO 11 METERS STEEL
POLES INCLUDING EXCAVATION OF PITS &
REFILLING OF EARTH CARTING OF
TRANSFORMERS FROM STORE TO SITE,
FIXINGOF CHANNELS SUPPORTING ANGLES,
BRACING, CROSS ARMS,CLAMPS,
ANTICLIMBING DEVICES, DANGER
BOARDS,CONDUCTOR AND CABLE WIRING
ETC. COMPLETE AND PAINTING OF POLES
FABRICATED MATERIALS USED ON THE POLES
AND NUMBERING AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTIONS
OF GUY SETS AND EARTHING.
ERECTION OF GUY SET INCLUDING
EXCAVATION OF PITS & REFILLING OF EARTH
AS PER STANDARD SPECIFICATION WITH STAY
11 9926000011 CLAMPS, STAY WIRE, ANCHOR ROD, TURN No. 561
BUCKLE, EYEBOLT, GUY INSULATOR, CEMENT
CONCRETE BLOCK ETC. BUT EXCLUDING
CONCRETING OF POLES, GUYS, ETC.
INCLUDING COST OF CEMENT SAND METAL
(1:2:4) AND WATER ETC. AS PER STANDARD
ERECTION OF COIL TYPE EARTHING
INCLUDING COST OF COAL,SALT ETC. BUT
WITHOUT COST OF GI WIRE AS PER
STANDARD SPECIFICATION(20kg solt+20kg coal)
ERECTION OF GI PIPE/CI PLATE TYPE
EARTHING INCLUDINGCOST OF COAL SALT
14 9926000014 ETC. BUT WITHOUT COST OF PIPE/GIPLATE GI No. 781
WIRE AS PER STANDARD SPECIFICATION.(20kg
solt+20kg coal)
ERECTION OF STREET LIGHT FIXTURE
COMPLETE WITH CLAMPS, BRASS NIPPLE,
BRASS HOLDER TECK WOOD
BUSH,REFLECTORS FUSE, WIRING ETC. AS
PER STANDARD SPECIFICATION BUT
EXCLUDING COST OF MATERIALS.
STRINGING OF ALL TYPE OF CONDUCTOR
(EXCEPT DOG CONDUCTOR) FOR 11/22KV & LT ONE COND
LINES INCLUDING FIXING OF INSULATORS, PER KM
BINDING JUMPERING ETC.
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0064/01/2026 Approved Date: 08-01-2026
STRINGING OF GI WIRE 8 SWG INCLUDING
BINDING JUMPERING ETC.
PROVIDING SINGLE PHASE SERVICE
CONNECTION WITH PVC 4MM TWIN CORE
CABLE FROM TERMINAL POLE TO METERING
18 9926000018 POINT INCLUDING FIXING OF METER WITH No. 397
METER EARTHING COMPLETE WORK AS PER
STANDARD SPECIFICATION BUT EXCLUDING
COST OF MATERIALS.
PROVIDING THREE PHASE 4 WIRE SERVICE
CONNECTION WITH PVC 4MM2/10MM2 FOUR
CORE CABLE FROM TERMINAL POLE TO
19 9926000019 METERING POINT INCLUDING FIXING OF No. 546
METER WITH METER EARTHING COMPLETE
WORK AS PER STANDARD SPECIFICATION BUT
EXCLUDING COST OF MATERIALS.
ADDITIONAL COST FOR EXCAVATION OF PIT IN
HARD ROCK AREA FOR ERECTION OF POLE/
GUY ETC. AS PER STANDARD SPECIFICATION
OVER & ABOVE NORMAL COST COVERED
AGAINST EXCAVATION OF PIT UNDER NORMAL
SOIL FOR ERECTION OF POLE,GUY, DOUBLE
POLE STRUCTURE EARTHING WITH THE
APPROVAL OF SUPDT.ENGINEER.
PROVIDING GUARDING TO HT LINE ON ROAD/
PROVIDING GUARDING OF LT LINES ON
ROAD/RAIL CROSSING.
23 9926000023 LT LINE TAPPING- SINGLE PHASE No. 51
24 9926000024 LT LINE TAPPING- THREE PHASE No. 93
LAYING OF OVER HEAD LT CABLE FOR ROAD
25 9926000025 CROSSING,HT LINE CROSSING AND No. 263
TELEPHONE LINE CROSSING ETC.(PER SPAN)
ERECTION OF SINGLE POLE STRUCTURES
WITH , HG FUSES,TRANSFORMERS,
LIGHTENING ARRESTOR, DISTRIBUTION BOX.
ON 8 METERS 200 KGAND PSC POLE
INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROM STORES TO SITE,
FIXING OF CHANNELS, SUPPORTING
26 9926000026 ANGLES,BRACINGS CROSS ARMS CLAMPS, No. 4537
ANTICLIMBING DEVICES DANGER BOARDS,
CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLE
AND NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OFGUY SETS AND
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0064/01/2026 Approved Date: 08-01-2026
ERECTION OF SINGLE POLE STRUCTURES
WITH , HG FUSES,TRANSFORMERS,
LIGHTENINGARRESTOR, DISTRIBUTION BOX.
ON 9 to 11 METERS RSJ POLE INCLUDING
EXCAVATION OF PITS AND REFILLING OF
EARTH, CARTING OF TRANSFORMERS FROM
STORES TO SITE, FIXING OF CHANNELS,
SUPPORTING ANGLES,BRACINGS CROSS
ARMS CLAMPS, ANTICLIMBING DEVICES
DANGER BOARDS, CONDUCTOR AND CABLE
WIRING ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLE
AND NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OFGUY SETS AND
ERECTION OF PSC POLES OF 10 *270 KG
INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH, FIXING OF CROSS
ARMS, TOP FITTING CLAMPS ANTI-CLIMBING
DEVICES, INSULATORS ETC. COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COST
OF PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUY SET AND
ERECTION OF DOUBLE POLE STRUCTURE OF
10 METERS 270 KG PSC POLES INCLUDING
EXCAVATION OF PITS & REFILLING OF
EARTHING, FIXING OF CHANNELS,
SUPPORTING ANGLES,CLAMPS, ANTI-
CLIMBING DEVICES DANGER
BOARDS,INSULATORS ETC.COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED
ON THE POLES AND NUMBERING WITH COST
OF PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUY SETS AND
EARTHING.(WITHOUT AB SWITCH)
STRINGING OF 100MM2 ACSR/100MM2 AAAC
30 9926000030 CONDUCTOR FOR LT LINES INCLUDING FIXING 4861
OFINSULATORS, BINDING JUMPERING ETC.
STRINGING OF DOG CONDUCTOR FOR 11/22KV
31 9926000031 HT LINES INCLUDING FIXING OF INSULATORS, 4378
BINDING JUMPERING ETC.
ERECTION OF DOUBLE POLE STRUCTURES
WITH MOUNTING OF AB SWITCH, HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTORS,
DISTRIBUTION BOX. OF 10 METERS 270 KGAND
PSC POLES INCLUDING EXCAVATION OF PITS
AND REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROMSTORES TO SITE,
FIXING OF CHANNELS, SUPPORTING
32 9926000032 ANGLES,BRACINGS CROSS ARMS CLAMPS, No. 10662
ANTI-CLIMBING DEVICES,DANGER BOARDS,
CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLES
AND NUMBERING WITH COST OF PAINT AS
PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0064/01/2026 Approved Date: 08-01-2026
DISMENTALLING OF 8 MTR PSC POLE WITH
CREDITING OF FABRICATION AT STORE &
STACKING OF POLE SAFELY ON ROAD SIDE
OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF 10 MTR PSC POLE WITH
CREDITING OF FABRICATION AT STORE &
STACKING OF POLE SAFELY ON ROAD SIDE
OR CREDITING TO DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE
(8 MTR PSC POLE) (WITH TRANSFORMER)
WITH CREDITING OF FABRICATION &
TRANSFORMER AT STORE & STACKING OF
POLE SAFELY ON ROAD SIDE OR CREDITING
TO DEPARTMENTAL STORE
DISMENTALLING OF TRANSFORMER CENTRE
(8 MTR PSC POLE) (WITHOUT TRANSFORMER)
36 9926000036 WITH CREDITING OF FABRICATION AT STORE No. 2701
& STACKING OF POLE SAFELY ON ROAD SIDE
OR CREDITING TO DEPARTMENTAL STORE
STRINGING OF LT ABC OF 1*35 SQ MM + 1*25
SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, LT SHACKLE INSULATOR ETC.
37 9926000037 FOR FIXING OF MESSENGER WIRE AND TO KM 7046
PROVIDE SERVICE CONNECTION ON AERIAL
BUNCH CABLE BY INSULATED PIERCEING
CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE.
STRINGING OF LT ABC OF 3*50 SQ MM +1*25
SQ MM+1*35 SQ MM INCLUDING FITTING OF
ALL ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, LT SHACKLE INSULATOR ETC.
FOR FIXING OF MESSENGER WIRE AND TO
PROVIDE SERVICE CONNECTION ON AERIAL
BUNCH CABLE BY INSULATED PIERCEING
CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE.
STRINGING OF 11KV ABC OF 3*95 SQ MM +80
SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, BINDING TO PIN
INSULATOR,PREPARING SHACKLE
POINT,JUMPERS ETC. AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE
STRINGING OF 22 KV ABC OF 3*70 SQ MM +95
SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, BINDING TO PIN
INSULATOR,PREPARING SHACKLE
POINT,JUMPERS ETC. AS REQUIRED AND
DIRECTED BY ENGINEER IN CHARGE
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0064/01/2026 Approved Date: 08-01-2026
STRINGING OF LT ABC OF 2*50 SQ MM +1*25
SQ MM+ 35 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN
SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, LT SHACKLE INSULATOR ETC.
41 9926000041 FOR FIXING OF MESSENGER WIRE AND TO KM 9863
PROVIDE SERVICE CONNECTION ON AERIAL
BUNCH CABLE BY INSULATED PIERCEING
CONNECTORS THROUGH SERVICE
CONNECTION BOX COMPLETE AS REQUIRED &
DIRECTED BY ENGINEER IN CHARGE.
DISMENTALING OF RSJ (9/11 METER) POLE
AND CREDITING THE OLD MATERIAL TO STORE
DISMENTALING OF TRANSFORMER CENTER
ON 10MTR,270KG PSC POLE(WITHOUT
TRANSFORMER) WITH CREDITING OF
FABRICATION AT STORE AND STACKING OF
POLE SAFELY ON ROAD SIDE OR CREDITING
TO DEPARTMENTAL STORE
DISMENTALING OF TRANSFORMER CENTER
ON 10MTR,270KG PSC POLE(WITH
TRANSFORMER) WITH CREDITING OF
FABRICATION AT STORE AND STACKING OF
POLE SAFELY ON ROAD SIDE OR CREDITING
TO DEPARTMENTAL STORE
DISMENTLING OF 11KV ABC OF 3*95 SQ MM
+80 SQ MM AND CREDITING FITTING OF ALL
ACESSARIES AND FABRICATION TO
DEPARTMENTAL STORE
DISMENTLING OF 22 KV ABC OF 3*70 SQ MM
+95 SQ MM AND CREDITING FITTING OF ALL
ACESSARIES AND FABRICATION TO
DEPARTMENTAL STORE
DISMENTALING OF LT ABC OF 1*35 SQ MM +
1*25 SQ MM AND CREDITING FITTING OF ALL
ACESSARIES TO DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 3*50 SQ MM
48 9926000048 +1*25 SQ MM+1*35 SQ MM AND CREDITING KM 6166
FITTING OF ALL ACESSARIES TO
DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 2*50 SQ MM
49 9926000049 +1*25 SQ MM+ 35 SQ MM AND CREDITING KM 4930
FITTING OF ALL ACESSARIES TO
DEPARTMENTAL STORE.
RESTRINGING OF ALL TYPE OF CONDUCTOR
(EXCEPT DOG CONDUCTOR) FOR 11/22KV & LT ONE COND
LINES INCLUDING FIXING OF INSULATORS, PER KM
BINDING JUMPERING ETC.
RESTRINGING OF DOG CONDUCTOR FOR
51 9926000051 11/22KV HT LINES INCLUDING , BINDING 3129
LABOUR CHARGE FOR THE INSTALLATION OF
52 9926000052 NEW DTR METER. (METER WILL BE PROVIDED No. 355
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0064/01/2026 Approved Date: 08-01-2026
LABOUR CHARGE FOR THE REPLACEMENT OF
DTR METER AND OLD METER SHOULD BE
CREDITED TO SDN STORE. (METER WILL BE
PROVIDED BY DGVCL)
LABOUR CHARGE FOR PROVIDING CT COIL
54 9926000054 FOR DTR METER CONNECTION. (CT COIL WILL PER CT 85
BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR REPLACEMENT OF CT
COIL FOR DTR METER CONNECTION AND OLD
CT SHOULD BE CREDITED TO SDN STORE. (CT
COIL WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR FIXING OF MMB FOR
56 9926000056 DTR METER (MMB WILL BE PROVIDED BY No. 128
LABOUR CHARGE FOR REPLACEMENT OF DTR
57 9926000057 METER BOX. (METER WILL BE PROVIDED BY No. 1820
PROVIDING / REPLACEMENT OF 1.5 SQ MM
58 9926000058 CORE COPPER CABLE 3.5 METER (CABLE TO No. 1840
BE PROVIDED BY AGENCY)
LABOUR CHARGE FOR
PROVIDING/RECONNECTION OF TERMINAL PER
CONNECTION WITH PROPER SIZE OF LUGS. TERMINATION
(LUGS COST IS BORNE BY AGENCY)
LABOUR CHARGE FOR THE SPOT READING OF
DTR METER WITH DETAIL SURVEY OF DEFECT
IF ANY. A DULY SIGN COPY BY SURVEYOR
PERSON OF AGENCY IN PRO-FORMA REPORT
60 9926000060 SHOULD BE SUBMITTED TO SDN OFFICE.(* PER DTR 60
ONLY IF ALL PARAMETER OF VOLTAGE,
CURRENT & LOAD AS SHOWN IN PER-FORMA
IS FILLED) AS PER THE INSTRUCTION OF
ENGINEER IN-CHARGE.
LABOUR CHARGE FOR THE SPOT READING OF
DTR METER WITH DETAIL SURVEY OF DEFECT
IF ANY. A DULY SIGN COPY BY SURVEYOR
PERSON OF AGENCY IN PRO-FORMA REPORT
SHOULD BE SUBMITTED TO SDN OFFICE.
(DULY FILL PER-FORMA IN FAULT CONDITION
IN WHICH READING PARAMETER IS NOT
SHOWN IN METER)
INSTALLATION OF DTR METER INCLUDING
METER BOX, PROVIDING & FIXING OF 1.5SQ
MM SINGLE STRAND 10 CORE ARMOURED
COPPER CABLE (3.5METER), TERMINATION IN
METER & COIL ETC.(METER, METER BOX,
C.T./P.T. COIL WILL BE PROVIDED BY DGVCL)
INSTALLATION OF DTR METER INCLUDING
METER BOX, TERMINATION IN METER & COIL
63 9926000063 ETC. (WITHOUT 10CORE COPPER CABLE) No. 886
(METER, METER BOX, C.T./P.T. COIL WILL BE
PROVIDED BY DGVCL)
Binding of messanger Conductorat with a distance
not more than 0.75 mtr with 6 turns minimum on
XLPE Cable with single strand binding wire
(including cost of binding wire)
Supply and Installation of 11/22 kV Distribution
Transformers HT Terminal protector (UV
Resistance) with using 95/120/150 sq.mm long
barrel aluminum lug. (1Set = 3 Nos i.e. on R, Y, B)
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0064/01/2026 Approved Date: 08-01-2026
Supply & Installation of HT EPR Tap on 11/22 kV
Distribution Transformer with replacement of bare
conductor by HT ABC conductor (DO bottom side to
transformer) after removal of semi conductor by HT
ABC (6 inch both side). HT ABC to be supplied by
DGVCL. (1Set = 3 Nos i.e. on R, Y, B)
Supply, Installation, Testing and Commissioning of
Maintenance Free, Ready Capsule, Pipe-In-Cage
(Pic) Type, Earth Electrodes for HT Feeder Pole
Having 2000 mm Electrode Length as per the
Tender Specifications and Drawing. (All Materials
Will Be Supplied By Agency)
Supply, Installation, Testing and Commissioning of
Maintenance Free, Ready Capsule, Pipe-In-Cage
(Pic) Type, Earth Electrodes for HT Feeder Pole
Having 3000 mm Electrode Length as per the
Tender Specifications And Drawing. (All Materials
Will Be Supplied By Agency)
Supply and Installation of 25 X 3 mm GI Strip having
hot dip- galvanized-zinc coating of 80-100 microns
without any joints or welding. Both the end of the GI
strip should be connected with GI nut bolts and
required fabrication work for giving separate
69 9926000090 earthing connections to(1) Neutral of the Meter
transformer(2) MS structures of the transformer
center (Approximately 25 meter GI strip per
transformer centre- as per requirement and
instruction of Engineer in- charge) (All Materials will
be supplied by Agency)
Supply and Installation of uPVC standard make
Pipe of 1.25" diameter for covering GI strip with UV
protected Cable Ties of 550 X 7.6 mm size to bind
with pole face(Approximately 25 meter uPVC pipe
for GI strip covering per transformer centre -as per
requirement and instruction of Engineer in-charge.
Supply & fixing of upto 33 kV Conducotr sleev for
Busbar to Drop out Fuse and Drop out fuse to
71 9926000093 Transformer H.T. including Busbar (12 mm sleev) Meter
as per technical specification. (All Materials will be
supplied by Agency)
Supply & fixing of upto 33 kV Conducotr sleev for
Busbar to Drop out Fuse and Drop out fuse to
72 9926000094 Transformer H.T. including Busbar(15 mm sleev) as Meter
per technical specification. (All Materials will be
supplied by Agency)
Supply & fixing of Disc type Red Color FRP(Non-
flammable) material with Weather resistant, Non-
73 9926000095 conductive bird guard OD=300 MM, ID=33 MM, No
Width =1.25 MM, one side cut from ID to OD. (All
Materials will be supplied by Agency)
Providing and fixing of LT Terminal protectors i.e.
Re-useable boot (LT Side 1.1 kV) including LT (1.1
kV) insulating taps. All live part at LT side shall be
covered with fixing of LT insulating taps.
75 Nylon Net around Transformer Center
75.1 9926000097 Nylon Net (12 * 15 ft) Per Net
75.2 9926000098 Nylon Dori Per TC
Labour charge for fitting Nylon Net (All fabricated
75.3 9926000099 material for fitting nylon net shall be provided by Per TC
TOTAL ESTIMATED AMOUNT OF SCHEDULE B1
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0064/01/2026 Approved Date: 08-01-2026
1 9924000001 Cutting of Tree branches surounding HT/LT line Per Tree 57
Replacement of old jumpers & providing new double
2 9924000002 jumpers with 8" binding & capsuling with PVC pipe No. 90
3 9924000005 Support pole for Stay PSC/STP/RSJ No. 633
4 9924000006 Pin binding of conductor 11/22kv Pin insulator No. 18
Pin binding of conductor 11/22kv Pin insulator per
pole in costle area with cleaning .
6 9924000008 Pin binding of conductor LT shakel insulator No. 14
Replacement of one/both disc.insulator at strain
8 9924000010 Replacement of LT shackle insulator at cut point No. 31
9 9924000011 Refixing of V cross Arm No. 61
10 9924000012 Replacement of V cross Arm No. 210
11 9924000013 Refixing of Top fitting in proper position No. 41
12 9924000014 Replacement of Top fitting No. 51
13 9924000015 Replacement of LT cross Arm No. 105
Providing DO fuse on DP with carting &
jumpuring(ONE DO FUSE)
Numburing of pole with paint by preparing back
15 9924000017 ground of one colour and have lettering(height 3" * No. 46
width 0.5") using stensil
16 9924000018 Fixing of MMB(1PH.) at consumer end No. 86
17 9924000019 Fixing of MMB(3PH.) at consumer end No. 128
18 9924000020 Replacement of (1ph.) meter for Urban area No. 51
19 9924000021 Replacement of (1ph.) meter for Rural area No. 74
painting consumer no. on MMB (Urban) (with letter
size height 40mm* width 8mm)
painting consumer no. on MMB (Rural) (with letter
size height 40mm* width 8mm)
Replacement of deteriorated Single phase Service
Fixing of new dist. Box with complete wiring
including clamps,nut bolts etc.
Reparing of guarding involving reshaping of bearer
wire cross lacing binding etc.
Painting of steel fabricated material of RSJ DO DP
structure with paint
Painting of steel fabricated material of RSJ pole
26 9924000028 mounted transformer double pole structure with No. 3748
Painting of steel fabricated material of RSJ single
pole with paint
painting of steel fabricated material of PSC Single
pole (HT line) with paint
painting of steel fabricated material of PSC DO DP
double pole with paint
painting of steel fabricated material of PSC double
pole at pole mounted transformer with paint
31 9924000033 Providing line seperater single phase No. 11
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0064/01/2026 Approved Date: 08-01-2026
32 9924000034 Providing line seperater three phase No. 31
Replacement / Providing of stay insulator along with
adjustment of tension in stay wire
Replacement of deteriorated /providing LT dist. Box
34 9924000036 with new up to 100KVA capacity & crediting it to No. 1061
Replacement of deteriorated /providing LT dist. Box
35 9924000037 with new above 100KVA capacity & crediting it to No. 2084
36 9924000038 Adjustment of tension in stay wire No. 158
37 9924000039 Refitting of LA No. 31
Converting pin point to Shackle point including
dismentaling & restringing etc.
replacement of 11KV Pin insulator with providing
new double pin binding
replacement of 22KV Pin insulator by new 11kv pin
40 9924000042 insulator with spares & providing new double pin No. 81
Providing 11kv double disc insulators with binding &
Replacement of existing 11kv conductor (all size)
with new double pin binding
43 9924000046 Plumbing of PSC Pole with straightening at pin point No. 287
Plumbing of PSC Pole with straightening at tension
Plumbing of tilted DP structure (PSC/RSJ/STP) with
refilling of stone Murrum etc.
Providing new 11kv AB /GO switch with fabrication
and insulated colour code jumper, binding, lugs etc
Replacement of old 11kv AB /GO switch with
providing new insulated jumper, binding, lugs etc
Providing cage type loop guard in verticle LT line
with using PVC reel insulators etc
Labour charges for replacement /providing of MMB
49 9924000053 & service with all accessories for three phase No. 644
Labour charges for replacement /providing of MMB
50 9924000054 & service with all accessories for single phase No. 554
Dismentalling of existing Dist.X'mer center(RSJ
51 9924000055 /STP POLE) 25/63/100/200 KVA with all fabrication No. 5528
& creditig the old material to store
52 9924000056 Disconnection from LT pole 1 phase No. 46
Reconnection from LT pole 1 phase
( payment after receipt of R/C charges)
54 9924000058 Disconnection from LT pole 3 phase No. 66
Reconnection from LT pole 3 phase
( payment after receipt of R/C charges)
Dismentaling & removing of service line from pole &
crediting to S/dn (1 ph.)
Dismentaling & removing of service line from pole &
crediting to S/dn (3 ph.)
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0064/01/2026 Approved Date: 08-01-2026
Reconnection of service line complete with PVC
Reconnection of service line complete with PVC
Providing spiral type earthing by G.I. NO 8(weight
2kg -5mtr in length) with salt and coal 10kg each,
including pvc rigid pipe 20mm dia( 1.5mtr length) to
pass exposed part of G.I. wire at consumer end with
all materials, earth resistance should be less than
Providing and fixing of signle core 1.5 sq mm single
strand copper insulated cable with cable nail clip for
spiral type earthing at consumer end. The end of
G.I. no 8 is to be connected by connector with
61 9924000070 copper cable of which other end shall be connected per meter 30
to the earth terminal of meter box. This item shall be
used in location where there is more distance
between earth terminal and earthing terminal of
meter. (All materials supplied by contractor)
Stringing of LT ABC of 1*35 SQ MM + 1*25 SQ MM
including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, LT
shackle insulator etc. for fixing of messenger wire
and inclusive of dismantling charge of existing bare
conductor and crediting in to store & dismentaling of
service line from LT bare conductor and to provide
service connection on Aerial Bunch Cable by
insulated pierceing connectors through service
connection box complete as required & directed by
Engineer in Charge.
Stringing of LT ABC of 3*50 SQ MM +1*25 SQ
MM+1*35 SQ MM including fitting of all acessaries
i.e. special design suspension / tension clamp,
fixing of cross arm, LT shackle insulator etc. for
fixing of messenger wire and inclusive of
dismantling charge of existing bare conductor and
crediting in to store & dismentaling of service line
from LT bare conductor and to provide service
connection on Aerial Bunch Cable by insulated
pierceing connectors through service connection
box complete as required & directed by Engineer in
Stringing of 11KV ABC of 3*95 SQ MM +80 SQ MM
including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm,
binding to pin insulator,preparing shackle
point,jumpers etc. and inclusive of dismantling
charge of existing bare conductor and crediting in to
store complete as required & directed by Engineer
Stringing of 22 KV ABC OF 3*70 SQ MM +95 SQ
MM including fitting of all acessaries i.e. special
design suspension / tension clamp, fixing of cross
arm, binding to pin insulator,preparing shackle
point,jumpers etc. and inclusive of dismantling
charge of existing bare conductor and crediting in to
store complete as required & directed by Engineer
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0064/01/2026 Approved Date: 08-01-2026
Stringing of LT ABC of 2*50 SQ MM +1*25 SQ MM+
35 SQ MM including fitting of all acessaries i.e.
special design suspension / tension clamp, fixing of
cross arm, LT shackle insulator etc. for fixing of
messenger wire and inclusive of dismantling charge
66 9924000069 of existing bare conductor and crediting in to store & KM 15613
dismentaling of service line from LT bare conductor
and to provide service connection on Aerial Bunch
Cable by insulated pierceing connectors through
service connection box complete as required &
directed by Engineer in Charge.
TOTAL ESTIMATED AMOUNT OF SCHEDULE B2
Labour charge for excavation of cable trench of
400mm width x 1200mm depth, in any type of soil
for laying of cable of size up to 240 mm2 (For
1 9925000001 additional cable 200 mm additional width shall be Meter 72
considered i.e. half trench length is to be
Labour charge for excavation of cable trench of
600mm width x 1200mm depth, in any type of soil
for laying of cable of size up to 240 mm2 (For
additional cable 200 mm additional width shall be
considered i.e. half trench length is to be
Labour charge for excavation of cable trench of
400mm width x 1500mm depth, in any type of soil
for laying of cable of size up to 240 mm2 (For
additional cable 200 mm additional width shall be
considered i.e. half trench length is to be
Labour charge for laying of 11kV / 22 kV XLPE
Cable of size up to 240 mm2 & preparation of sand
layer 100mm thick, in the cable trench & covering
the cable with 150 mm dia (Inner), thickness
mm, 1.0 meter long RCC half round muffs and
providing and fixing of 4inch width yellow colour
4 9925000004 polyethylene tape with printing "CAUTION Meter 171
ELECTRIC CABLE BELOW" at 0.75 m depth from
ground surface after laying cable in trench. This will
provide indication that electric cable is passing
underground so as to protect cable from mechnical
injuries, refilling the same, as per Instruction of
Engineer in Charge (EIC).
Labour charge for horizontal drilling using Auger
machine without damage to surface road at max
mtrs depth & putting of 6.11 kg/cm2 , class-4,Green
color, 110mm O.D. , 8.5mm thickness H.D.P.E. pipe
confirms to IS 4984-1987(3rd revision) and BIS
certification and laying of 11KV/22KV XLPE cable of
size up to 240 mm2 in HDPE pipe, as per Site
Condition (excluding cost of pipe). The detail map
obtained from HDD machine and excell sheet(hard
and soft copy) indicating the respective depth and
distance from adjacent landmark for each segment
for HDD is must required to be submitted. HDD to
be carried out at depth 1.5 mtrs to 2.0 mtrs as per
site conditions and as per instruction of EIC.
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0064/01/2026 Approved Date: 08-01-2026
Labour charge for horizontal drilling manually
without damage to surface road at max 2.0 mtrs
depth & putting of 6.11 kg/cm2 , class-4,Green
color, 110mm O.D. , 8.5mm thickness H.D.P.E. pipe
confirms to IS 4984-1987(3rd revision) and BIS
certification and laying of 11KV/22KV XLPE cable of
6 9925000006 size up to 240 mm2 size, as per Site Condition Meter 615
(excluding cost of pipe). The detail map and excell
sheet(hard and soft copy) indicating the respective
depth and distance from adjacent landmark for each
segment of cable to be submitted. Drilling to be
carried out at depth Minimum 1.2 mtrs to 2.0 mtrs
as per site conditions as per instruction of EIC.
Supply of 6.11kg/cm2 , class-4,Green color, 110mm
O.D. , 8.5 mm thickness H.D.P.E. pipe confirms to
7 9925000007 IS 4984 and BIS certification for laying of Meter 430
underground 11KV / 22KV XLPE cable up to
Labour work for RCC concreting on disputed
location and repairing of damage portion of road
8 9925000008 crossing for the work carried out for roads crossing CMT 3189
as well as concreting & muffing of ploes including all
materials (1:2:4)
Providing & fixing concrete stone route marker of
300 mm width x 150 mm thick x 650 mm height
embedded in earth at least 300 mm below &
mm above ground level respectively at distance
approx 50 meters along the length of cable. The
RCC concreting (1:2:4)(all necessary maeterials will
be in bidder's scope) of route marker is to be carried
out 300 mm width x 150 mm thick x 300 mm below
ground level as per instruction of EIC. The route
marker should be with name of company with
approved yellow colour-DGVCL. The distance from
marker to cable and cable depth with feeder name
etc., marked with arrow sign is to be painted on
it.The route marker is to be fixed at location near to
any fixed permanent location (not necessary to fix
exact on top of cable) as per instruction of EIC.
Erection of D.P. (double pole) structure using 9 /
Mtr. RSJ pole with cable connection arrangement
along with fitting of necessary fabrication for 11KV
cable including excavation of pit & refilling of earth
as per instruction of EIC. (Exclusive of concreting &
muffing of poles)
Erection of Single pole structure using 9 / 11 Mtr
RSJ pole with cable connection arrangement along
with fitting ofnecessary fabrication for 11KV/22 KV
cable including excavation of pit & refilling of earth
as per instruction of EIC. (Exclusive of concreting &
muffing of poles)
Erection of D.P. (double pole) structure using
Mtr. PSC pole with cable connection arrangement
along with fitting of necessary fabrication for 11KV
cable including excavation of pit & refilling of earth
as per instruction of EIC. (Exclusive of concreting &
muffing of poles)
Erection of Single pole structure using 8.0 Mtr PSC
pole with cable connection arrangement along with
fitting ofnecessary fabrication for 11KV/22 KV cable
including excavation of pit & refilling of earth as per
instruction of EIC. (Exclusive of concreting &
muffing of poles)
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0064/01/2026 Approved Date: 08-01-2026
Labour charge for erecting of 11kV / 22 kV XLPE
cable of size up to 240 mm2 on DP Structure with
14 9925000014 fixing of 02 Nos polymer cleats on top and middle per Job 591
part.Polymer cleats, nut bolts etc. fixing material to
be provided by contractor.
Providing & fixing of 6.11kg/cm2 , class-4,Green
color, 110mm O.D. , 8.5mm thickness H.D.P.E. pipe
confirms to IS 4984 and BIS certification on the
erected DP structure for the mechanical protection
of cable by inserting the cable inside HDPE pipe.
15 9925000015 The HDPE pipe shall be erected in such a way that Per Job 1461
300mm shall be below the ground level and the rest
2700 mm shall be supported on the DP Structure
with 01 No Polymer cleat.All materials including
polymer cleat and Nut bolt to be provided by
Providing and fixing of pipe type earthing from
mm dia class-B GI pipe with pit to be filled with salt
& coke and construction of chamber as per DGVCL
16 9925000016 Drg. No. dg /100 for DP and cable. The earthing pit No. 3635
should be joined with cable by G.I. strip of size 1”
width & 2 mm thick. All material GI pipe, Coke, Salt
etc will be supplied by bidder.
Supply & fixing of heat shrink type end
terminations (outdoor) for upto 11kV 3C x
mm2 size XLPE cable as per DGVCL technical
Supply & fixing of heat & shrinkable end
terminations (outdoor) for upto 22 kV 3C x 185 mm2
size XLPE cable as per DGVCL technical
Supply & fixing of heat shrink type end terminations
19 9925000019 (indoor) for upto 11kV 3C x 185 mm2 size XLPE No. 3635
cable as per DGVCL technical specification)
Supply & fixing of heat & shrinkable end
terminations (indoor) for upto 22 kV 3C x 185 mm2
size XLPE cable as per DGVCL technical
Supply & fixing of heat shrinkable straight through
21 9925000021 joint for upto 11kV 3C x 185 mm2 size XLPE No. 6774
cableas per DGVCL technical specification.
Supply & fixing of heat shrinkable straight through
22 9925000022 joint type for upto 22kV 3C x 185 mm2 size XLPE No. 11590
cable as per DGVCL technical specification
Labour charge for excavation of 2100mm long x
1200mm wide x 1200 mm deep joint pits for
installation of 11kV / 22kV Straight through joints as
23 9925000023 per instruction of engineer-in-charge & covering the No. 399
cable with 150 mm dia (Outer), thickness 25 mm,
1.0 meter long RCC half round muffs & refilling
same as per instruction of EIC .
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0064/01/2026 Approved Date: 08-01-2026
Providing and fixing of insulating bus bar, made
from 11KV/22KV XLPE cable after removal of semi
conducting layer and applying of PVC heat
shrinkable anti-tracking core insulating tubing
(1.1KV), on both end terminal using Aluminium long
barrel heavy duty up to 240 sq mm lugs, Aluminium
bus connector. Taping with PG- clamp for bus
conductor as per drawing and as per instruction of
EIC. The Alluminium lugs and PG clamp shall be
covered with 11KV/22KV HT insulating tapes.
(11KV/22KV XLPE cable will be in scope of DGVCL
while all other materials will be in bidder's scope)
Testing of cable at various points and
commissioning the feeder as per instruction of
engineer-in-charge.Test result shall be submitted by
contractor with bill.
Preparation and submission of 6 (six) copies, of
complete layout drawings with GIS mapping as per
actual cable routing showing road crossing, HDPE
pipe sleeving, jointing locations, markers etc.
Providing and fixing of Sign Board at junction point
Made out of 2 mm aluminium sheet size 750x300
mm (2.5 x 1ft) rectangle, as per design, pre treated
with phosphate process and acid etching coated
with one coat of epoxy primer and two coats of best
quality paints, refloctrorised with Hi-Intensity retro –
reflective sheeting as per the latest and frame
27 9925000027 fabricated from suitable size iron angle. The Sign No. 10023
Board is to be fixed on the base prepared from
channel and bracing angles which is grouted by
means of cement concreting of 1:2:4 for size of
mm dia x 800 mm height (500 mm to be grouted in
ground). The details to be displayed on sign board
will be given by In-charge Engineer.
(a) Hi intensity Micro prismatic Grade
Providing and fixing of Sign Board (Danger Board)
on Distribution Transformer Centers
Made out of 2mm aluminium sheet size
300x300mm (1x1ft) as per design, pre treated with
phosphate process and acid etching coated with
one coat of epoxy primer and two coats of best
quality paints, refloctrorised with Hi-Intensity retro-
reflective sheeting as per the latest and frame
fabricated from suitable size iron angle. The Sign
Board (Danger Board is to be fixed at the location
as per instruction of In-charge Engineer.
(a) Hi intensity Micro prismatic Grade
Providing & fixing of aluminium tag of size 250 mm
(L) x 75 mm (W) from 3 mm aluminium sheet along
with 1.0 mm dia aluminium binding wire for fixing of
aluminium tag near end termination joint at DP
structure for identifyng the cable. The details of
feeder i.e. 11 / 22 KV with feeder name shound be
punched on the tag by letter punch of size 16 mm
as per instruction of In-charge Engineer.
Supply & fixing of heat shrink type end terminations
30 9925000030 (outdoor) for 11kV 3C x 240 mm2 size XLPE cable No. 4427
as per DGVCL technical specification
Supply & fixing of heat & shrinkable end
31 9925000031 terminations (outdoor) for 22 kV 3C x 240 mm2 size No. 6231
XLPE cable as per DGVCL technical specification)
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0064/01/2026 Approved Date: 08-01-2026
Supply & fixing of heat shrink type end terminations
32 9925000032 (indoor) for 11kV 3C x 240 mm2 size XLPE cable as No. 4338
per DGVCL technical specification)
Supply & fixing of heat & shrinkable end
33 9925000033 terminations (indoor) for 22 kV 3C x 240 mm2 size No. 6231
XLPE cable as per DGVCL technical specification
Supply & fixing of heat shrinkable straight through
34 9925000034 joint for 11kV 3C x 240 mm2 size XLPE cableas per No. 6829
DGVCL technical specification.
Supply & fixing of heat shrinkable straight through
35 9925000035 joint type for 22kV 3C x 240 mm2 size XLPE cable No. 11590
as per DGVCL technical specification
Installation, Testing and commissioning of
KV,630 A SCADA Compatible, RRL type- 3 Way
36 9925000038 RMU including Two numbers of earthings as per No. 42000
Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
Installation, Testing and commissioning of
KV,630 A SCADA Compatible, RRLL type- 4 Way
37 9925000039 RMU including Two numbers of earthings as per No. 42000
Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
Installation, Testing and commissioning of
22KV,630 A SCADA Compatible, RRL type-3 Way,
38 9925000040 RMU including Two numbers of earthings as per No. 53000
Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
Installation, Testing and commissioning of
22KV,630 A SCADA Compatible, RRLL type-4 Way,
39 9925000041 RMU including Two numbers of earthings as per No. 54500
Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
Construction of plinth for 11KV, RRL type- 3 Way
(i.e Two numbers of Isolator & One number of
Breaker) Ring Main Unit as per DGVCL's technical
specification mentioned in drawing no: Drg. 11kv-
01. All required material will be supplied by
Construction of plinth for 11KV, RRLL type- 4 Way
(i.e Two numbers of Isolator & Two number of
Breaker)Ring Main Unit as per DGVCL's technical
specification mentioned in drawing no:Drg. 11kv-
02.All required material will be supplied by
Construction of plinth for 22KV, RRL type- 3 Way
(i.e Two numbers of Isolator & One number of
Breaker) Ring Main Unit as per DGVCL's technical
specification mentioned in drawing no: Drg. 22kv-
01. All required material will be supplied by
Construction of plinth for 22KV, RRLL type- 4 Way
(i.e Two numbers of Isolator & Two number of
Breaker)Ring Main Unit as per DGVCL's technical
specification mentioned in drawing no:Drg. 22kv-
02.All required material will be supplied by
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0064/01/2026 Approved Date: 08-01-2026
Modifications e.g.Providing and fixing of Terminal
protectors i.e. Re-use able boot (HT Side 11/22KV,
LT Side 1.1KV) including 11/22 KV insulating taps
and L.T.(1.1 KV) insulating taps ,Busbar, Tapping
from Bus Bar (11/22 KV XLPE cable) through P.G.
Clamp for H.T. Jumper to D.O. Fuse to bushings of
Transformer Center, providing & Fixing of jumper
and providing & fixing of Heat Shrinkable Anti
Tracking Core Insulating Tubing (Insulation Level
44 9925000046 11/22 KV) in H.T. jumper , Clamping arrangement of No. 10152
cable support frame on both side of existing Over
Head type Distribution Transformer to utilize in
Under Ground cable network as per drawing & as
per instruction of Engineer incharge. All live parts
i.e. PG-Clamp, connections of D.O.fuses, HT
bushings etc . shall be covered with fixinng of 11/22
KV HT insulating tapes. ( 11/22 KV XLPE cable will
be in scope of DGVCL while all other materials will
be in bidder's scope ) .
Laying of any size of 11/ 22 KV XLPE /PILC Cable per cable per
in redaymade trench or in open space mtr
Labour charges for Lying of O/H XLPE cable pole to
Supply of 150 mm dia (Inner), thickness 25 mm,
meter long RCC half round pipe
Total of Schedule B1 + B2 + B3 is Rs. TOTAL
1.DGVCL will provide key material like M.S.
materials,ABC/Bare conductors,PSC/RSJ
Poles,Insulators,Fabricated materials etc. to the
2.All fabricated items shall be fabricated as per
DGVCL approved drawing and by welding rods
confirming to the relevent ISI specification and as
directed by Engineer in charge.
3.Necessary electricity connection for fabrication
items shall be provided by DGVCL on payment of
required charge for connection & electricity bill of
the same shall be paid by the agency.
4.All the rates are inclusive of PF & Exclusive of
GST applicable time to time.
5.All steel material are to be painted as below:
(a) Scrubbing of rusted surface properly before
applying the paints on to the RSJ poles & steel
fabricated materials of RSJ/PSC poles is must
(b) Two coats of approved ISI mark red oxide
(primer) is to be properly painted for the RSJ poles
& steel fabricated materials of RSJ/PSC poles.
(c) Two coats of approved ISI mark silver paint (i.e.
triple mangoes or equivalent quality silver paint) is
to be properly painted on to the RSJ poles & steel
fabricated materials of RSJ/PSC poles.
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0064/01/2026 Approved Date: 08-01-2026
1. Excavation, Drilling and Cable laying should be
done with all road safety measures such as hard
barricading, displaying “DANGER” sign and
“DGVCL - Work in Progress” on it with light
reflective strips or paint. Proof of all barricading and
safety equipment need to submit.
2. Cable laying should be done through roller (not
through tractor or pulling by any other vehicles).
3. Ownership document regarding roller/pulling
machine and HDD machine need to submit or
agreement with agency of above narrated machine
regarding work for this tender required to submit.
4. Trail pit excavation and De-excavation should
be done simultaneously so that any chance of road
accident can be prevented.
5. Three no of Polymer cleat should be provided
on rising cable for proper fitting and if it is not
feasible to provide third polymer cleat at the bottom
than two nos of polymer cleat on upper side and
strap strip on bottom end required to install for
proper fitting of rising cable.
6. 100% videography of cable laying along with
landmark location of cable laying required to be
Executive Engineer
Technical done and submit Pen drive to the concern engineer
Terms for their verification.
Sachin Division
7. Aluminum strip required to use to connect end
of cable at cable rising location as per instruction of
Engineer in charge. Also no joints will be allowed in
GI strip for cable Earthing and strip will be
connected through GI bolts only.
8. Issues regarding ROW on field should be
resolved by contractor itself.
9. Testing & measuring equipment: - 5 KV Digital
insulation testers, Digital Earth clamp meter for
measurement of Earthing and leakage current,
Digital Rodometer with NABL accredited agency
valid test certification.
10.Earthing value & Insulation Resistance (IR)
value of all location along with Geo tagged
(longitude & latitude) wise testing and measured
value photograph need to submit with Bill.
11.Depth chart should be provided at every
meter with mentioning landmark.
12. Partial Discharge test to be carried out on
sample part of cable before charging as decided by
in charge engineer.
13. Qualified cable jointer with Minimum five years
of experience required with necessary certification
regarding qualification and specific experience.
14. Performance Bank Guaranty required to submit
5% of tender value for two years against cable joint
failure. Moreover, cable joint failure or end
termination failure will have to repair within 24 Hrs
for 2 years of guaranty period.
15. Fixing of mechanical protection HDPE pipe at
rising should be properly buried as per specification.
16. Fixing of Route marker strictly as per
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Letter No: DGVCLSDUR/0064/01/2026 Approved Date: 08-01-2026
17. Minimum annual Turnover should be at least
tender estimated value and in addition to CVC
guideline narrated in tender for UG cable laying
18. Marking of feeder name, direction and location
on cable is compulsory during final scrutiny to
declare work completion.
19. End termination and straight joint kit should be
of premium quality as specified in Annexure-2.
Technical specifications for the same to be
submitted along with bid.
20. Cable straight joint should be done with mid
span joint instead of long barrel Lug.
21. Agreement with vendor of cable joint kit and End
termination kit to supply for this tender for concern
bidder should be submit at the time of bidding.
File No: DGVCLSDUR/MSC/e-file/4523/2026/0057/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTU
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
NOTICE INVITING TENDER 653.pdf
Tender 653.pdf
Technical Specifications.pdf
Schedule B.pdf
SCHEDULE B1 and B2 ARC HT LT TC with UG Cable and Maintenance.pdf
SCHEDULE B3 ARC HT LT TC with UG Cable and Maintenance.pdf
SCHEDULE B4 XLPE Cable 300 mm2 cable rate.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .